From 54fdabe3ec1791e2f4d44865d08c9ddfac83e5ee Mon Sep 17 00:00:00 2001 From: BastianTeufel Date: Thu, 13 Jun 2024 08:47:18 +0200 Subject: [PATCH] Quartz sync: Jun 13, 2024, 8:47 AM --- .../Programming PC Replacement.md | 4 +++ .../ProfDia(F) Fanuc/Fanuc Parameter Setup.md | 26 +++++++++---------- 2 files changed, 17 insertions(+), 13 deletions(-) diff --git a/content/ProfDia(F) DMG LT/Programming PC Replacement.md b/content/ProfDia(F) DMG LT/Programming PC Replacement.md index e40ec3f..2af57a7 100644 --- a/content/ProfDia(F) DMG LT/Programming PC Replacement.md +++ b/content/ProfDia(F) DMG LT/Programming PC Replacement.md @@ -50,3 +50,7 @@ Machine Network: 192.168.0.x, Subnet 255.255.255.0 > [!warning] > When the same IP range is used on two different ethernet interfaces, the license check of ProfDia and the communication will fail! +## Finalization + +After a successful migration of the ProfDia installation to the new PC, make sure to create a full backup or image of the newly installed PC. + diff --git a/content/ProfDia(F) Fanuc/Fanuc Parameter Setup.md b/content/ProfDia(F) Fanuc/Fanuc Parameter Setup.md index c1bab0d..88de77f 100644 --- a/content/ProfDia(F) Fanuc/Fanuc Parameter Setup.md +++ b/content/ProfDia(F) Fanuc/Fanuc Parameter Setup.md @@ -18,19 +18,19 @@ To successfully use the ProfDia Software with the FANUC EDM, the following param ### CNC Parameters -|Param. No| Bit | Value | Function / Purpose | -| --- | --- | ---- | ----- | -|1008[A] | 0 | 1| Rotary Axis Roll over is Valid (1) (ROA) | -|1008[A] | 1 | 0| Move A-Axis the shortest way to programmed position (RAB) | -|1008[A] | 2 | 1| Relative coordinates (RRL) are rounded by the amount of the shift per one rotation (1) | -|1420 | | e.g. 1080 for Hirschmann Rotary | Rotation speed for A-axis, Value probably dependent on brand and type of A-axis | -|3454 | 4 | 1| Enable “bit-setting” with argument “Q” via program | -|15150 | 0 | 1| Disable block ahead reading at M00/M01 (BST) | -|15320 | 0 | 1| Macro variable range > 13000 available (MEX) | -|15820 | 0 | 0| Straightness compensation OFF (WCC) | -|15886 | 0 | 0| Trimm function OFF (OIA) | -|16980 | 7 | 1| Switch on PCD Generator (if available) | -|16981 | 2 | 1| Enables Collision detection (Abnormal probe status) | +| Param. No | Bit | Value | Function / Purpose | +| --------- | --- | ------------------------------- | -------------------------------------------------------------------------------------- | +| 1008[A] | 0 | 1 | Rotary Axis Roll over is Valid (1) (ROA) | +| 1008[A] | 1 | 0 | Move A-Axis the shortest way to programmed position (RAB) | +| 1008[A] | 2 | 1 | Relative coordinates (RRL) are rounded by the amount of the shift per one rotation (1) | +| 1420 | | e.g. 1080 for Hirschmann Rotary | Rotation speed for A-axis, Value probably dependent on brand and type of A-axis | +| 3454 | 4 | 1 | Enable “bit-setting” with argument “Q” via program | +| 15150 | 0 | 1 | Disable block ahead reading at M00/M01 (BST) | +| 15320 | 0 | 1 | Macro variable range > 13000 available (MEX) | +| 15820 | 0 | 0 | Straightness compensation OFF (WCC) | +| 15886 | 0 | 0 | Trimm function OFF (OIA) | +| 16980 | 7 | 1 | Switch on PCD Generator (if available) | +| 16981 | 2 | 1 | Enables Collision detection (Abnormal probe status) | ### Keep Relay Parameters