diff --git a/custom_components/luxtronik/manifest.json b/custom_components/luxtronik/manifest.json index 82313a2..3e9bfc5 100755 --- a/custom_components/luxtronik/manifest.json +++ b/custom_components/luxtronik/manifest.json @@ -10,7 +10,6 @@ "codeowners": ["@BenPru"], "iot_class": "local_polling", "version": "2023.10.30", - "homeassistant": "2023.1.0", "dhcp": [ { "macaddress": "000E8C*" }, { "macaddress": "001999*" }, diff --git a/custom_components/luxtronik/translations/en.json b/custom_components/luxtronik/translations/en.json index be37057..87769e5 100644 --- a/custom_components/luxtronik/translations/en.json +++ b/custom_components/luxtronik/translations/en.json @@ -302,13 +302,173 @@ "793": "Major VSS fault", "-1": "Unknown error" }, - "cause": { - "name": "Cause" - }, - "remedy": { - "name": "Remedy" + "state_attributes": { + "timestamp": { + "name": "Timestamp" + }, + "cause": { + "name": "Ursache", + "state": { + "701": "Error low pressure.", + "702": "Low pressure stop\nRESET autom.", + "703": "Antifreeze\nPlease call fitter", + "704": "Error hot gas\nReset in hh:mm", + "705": "Motor protection VEN\nPlease call fitter", + "706": "Motor protection BCP\nPlease call fitter", + "707": "Coding of HP\nPlease call fitter", + "708": "Return sensor\nPlease call fitter", + "709": "Flow sensor\nPlease call fitter", + "710": "Hot gas sensor\nPlease call fitter", + "711": "External temp. sensor\nPlease call fitter", + "712": "Domestic hot water sensor.\nPlease call fitter", + "713": "HS-on sensor\nPlease call fitter", + "714": "Hot gas SW\nReset in hh:mm", + "715": "High-pressure switch-off\nRESET autom.", + "716": "High-pressure fault\nPlease call fitter", + "717": "Flow rate HS\nPlease call fitter", + "718": "Max. outside temp.\nRESET autom. in hh:mm", + "719": "Min. outside temp.\nRESET autom. in hh:mm", + "720": "HS temperature\nRESET autom. in hh:mm", + "721": "Low-pressure switch-off\nRESET autom.", + "722": "Tempdiff HW\nPlease call fitter", + "723": "Tempdiff SW\nPlease call fitter", + "724": "Tempdiff defrosting\nPlease call fitter", + "725": "System error SW\nPlease call fitter", + "726": "Sensor mixing circ 1\nPlease call fitter", + "727": "Brine pressure\nPlease call fitter", + "728": "Sensor HS Off\nPlease call fitter", + "729": "Rotating field error\nPlease call fitter", + "732": "Cooling fault\nPlease call fitter", + "733": "Anode fault\nPlease call fitter", + "734": "Anode fault\nPlease call fitter", + "735": "Error Ext. En\nPlease call fitter", + "736": "Error solar collector\nPlease call fitter", + "737": "Error solar tank\nPlease call fitter", + "738": "Error mixing circle 2\nPlease call fitter", + "750": "Return sensor external\nPlease call fitter", + "751": "Phase monitoring fault", + "752": "Flow error", + "755": "Lost connection to slave\nPlease call fitter", + "756": "Lost connection to master\nPlease call fitter", + "757": "Low-pressure fault in SW-appliance", + "758": "Defrosting malfunction", + "759": "TDI message", + "760": "Defrosting fault", + "761": "LIN timeout/LIN-connection lost", + "762": "sensor (evaporator intake)", + "763": "sensor (compressor intake)", + "764": "Sensor Compressor heater", + "765": "Overheating", + "766": "compressor's functional range", + "767": "STB E-Rod", + "768": "Flow monitoring", + "769": "Pump control", + "770": "Low superheat", + "771": "High superheat", + "776": "limit of application-CP", + "777": "Expansion valve", + "778": "Low pressure sensor", + "779": "High pressure sensor", + "780": "EVI sensor", + "781": "Liquid temp. sensor before EXV", + "782": "Suction gas EVI temp. sensor", + "783": "Communication SEC - Inverter", + "784": "VSS lockdown", + "785": "SEC-Board defective", + "787": "VD alert", + "788": "Major VSS fault", + "789": "LIN/Encoding not found", + "790": "Major VSS fault", + "791": "Lost ModBus communication", + "792": "LIN-connection lost", + "793": "Major VSS fault", + "-1": "Unknown error" + } + }, + "remedy": { + "name": "Abhilfe", + "state": { + "701": "Check HP for leakage, switching point pressure state, defrosting and T-outd.min.", + "702": "Check HP for leakage, switching point pressure state, defrosting and T-outd.min.", + "703": "Check HP power, defrost valve and heating system.", + "704": "Check coolant quantity, evaporation, overheating flow, return and HS-min.", + "705": "Check set value and ventilator / BCP.", + "706": "Check set values, compressor, BOS.", + "707": "Coding resistance in HP, check plug and connection line.", + "708": "Check return sensor, plug and connection line.", + "709": "Check flow sensor, plug and connection line.", + "710": "Check hot gas sensor, plug and connection line.", + "711": "Check external temperature sensor, plug and connection line.", + "712": "Check domestic hot water sensor, plug and connection line.", + "713": "Check heat source sensor, plug and connection line.", + "714": "Check flow of domestic hot water, heat exchanger, domestic hot water temperature and circulation pump.", + "715": "Check flow of HW, overflows, temperature and condensation.", + "716": "Check flow of HW, overflows, temperature and condensation.", + "717": "Check flow, switching point for DFS, filter, air clearance.", + "718": "Check outside temperature and set value.", + "719": "Check outside temperature and set value.", + "720": "Check flow, filter, air clearance, temperature.", + "721": "Check switching point of the pressostat, flow on HS side.", + "722": "Check function and location of the flow and return sensor.", + "723": "Check function and location of the flow and return sensor.", + "724": "Check function and location of the flow and return sensor, HCP capacity, overflows and heating circles.", + "725": "Check circulating pump DHW, tank filling, shutoff move and 3-way valve. Ventilate hot water and SW.", + "726": "Check mixing circle sensor, plug and connection line.", + "727": "Check brine pressure and brine pressure pressostat.", + "728": "Check heat source sensor, plug and connection line.", + "729": "Check rotating field and compressor.", + "730": "The screed heating program could not reach an FL temperature level in the specified time interval. Screed heating program continues running.", + "732": "Check mixer and heating circulation pump.", + "733": "Check connection line between anode and potentio stat. Fill SW tank.", + "734": "Acknowledge error in order to release domestic hot water preparation again. Rectify 733.", + "735": "Check sensor “External energy source”, plug and connection line.", + "736": "Check “solar tank” sensor, plug and connection line.", + "737": "Check “solar tank” sensor, plug and connection line.", + "738": "Check “mixing circle 2” sensor, plug and connection line.", + "739": "Check “mixing circle 3” sensor, plug and connection line.", + "750": "Check external return sensor, plug and connection line.", + "751": "Check rotary field and phase-sequence relay.", + "752": "see errors No. 751 and No. 717.", + "755": "Check network connection, switch, and IP addresses. Perform HP search if necessary.", + "756": "Check network connection, switch, and IP addresses. Perform HP search if necessary.", + "757": "If this malfunction occurs three times, the installation can only be cleared again by authorised service personnel!", + "758": "Check flow rate. Check flow sensor.", + "759": "Check setting of additional heating generator and safety temperature limiter.", + "760": "Protect the fan and evaporator from strong wind.", + "761": "Check cable/contact.", + "762": "Check sensor, replace if necessary.", + "763": "Check sensor, replace if necessary.", + "764": "Check sensor, replace if necessary.", + "765": "If the error occurs several times, the refrigerant circuit is permanently blocked. Please call AS", + "766": "If there is an ZWE, switch on the ZWE for heating.", + "767": "Check the heating element and press the fuse back in.", + "768": "Check hydraulics, check pump, check flow.", + "769": "Check the wiring of the load and control cables of the circulation pump. Check the circulating pump. Remedy fault.", + "770": "Check the temperature sensor, pressure sensor and expansion valve.", + "771": "Check the temperature sensor, pressure sensor, fill quantity and expansion valve.", + "775": "Check the expansion valve, connection cable and if applicable the SEC board", + "776": "Check the thermodynamics.", + "777": "Check the expansion valve, connection cable and if applicable the SEC board.", + "778": "Check the sensor, connector and connection cable.", + "779": "Check the sensor, connector and connection cable.", + "780": "Check the sensor, connector and connection cable.", + "781": "Check the sensor, connector and connection cable.", + "782": "Check the sensor, connector and connection cable.", + "783": "Check the connection cable, interference suppression capacitors and wiring.", + "784": "Disconnect the complete system from the power supply for 2 minutes. If it occurs again, check the inverter and compressor.", + "785": "Replace the SEC board.", + "786": "Check the HZ/IO – SEC board wiring.", + "787": "Acknowledge fault. If an error occurs repeatedly, phone the authorised service personnel (customer service).", + "788": "Check the inverter.", + "789": "Check the connection cable LIN / coding resistor.", + "790": "Check the wiring, inverter and compressor.", + "791": "Check the Modbus wiring of inverter.", + "792": "Check the coding connector on the LIN board(s).", + "793": "Fault acknowledges itself." + } + } } - }, + }, "switchoff_reason": { "name": "Switchoff reason", "state": {