You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This is a consequence of HEP-FCC/FCCDetectors#11 - since the sensitive detectors are there several times in the stack, it depends on the order in the LD_LIBRARY_PATH which one dd4hep picks up. It turns out that the order is wrong (lcgeo comes first) by default, so while the code is not reorganized I have to manually patch the setup script. Should be fixed for the current one.
Full sim example do not run out of the box if we do not comment lines like
https://github.com/HEP-FCC/FCCSW/blob/master/Examples/options/geant_fullsim_fccee_cld_pgun.py#L57
The text was updated successfully, but these errors were encountered: