forked from zellneralex/klipper_config
-
Notifications
You must be signed in to change notification settings - Fork 0
/
z_calibration.cfg
80 lines (80 loc) · 3.93 KB
/
z_calibration.cfg
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
#####################################################################
# Z Calibration
#####################################################################
[z_calibration]
# The X and Y coordinates (in mm) for clicking the nozzle on the
# Z endstop.
probe_nozzle_x: 123
probe_nozzle_y: 355
# The X and Y coordinates (in mm) for clicking the probe's switch
# on the Z endstop.
probe_switch_x: 123
probe_switch_y: 350
# The X and Y coordinates (in mm) for probing on the print surface
# (e.g. the center point) These coordinates will be adapted by the
# probe's X and Y offsets. The default is the relative_reference_index
# of the configured bed_mesh. It will raise an error if there is no
# probe_bed site and no bed_mesh with a relative_reference_index
# configured.
probe_bed_x: 175
probe_bed_y: 175
# The trigger point offset of the used mag-probe switch.
# This needs to be fined out manually.
# A smaller value is more away from bed
switch_offset: 0.475
# The maximum allowed deviation of the calculated offset.
# If the offset exceeds this value, it will stop!
# The default is 1.0 mm.
max_deviation: 2.0
# The number of times to probe each point. The probed z-values
# will be averaged. The default is from the probe's configuration.
#samples: default from "probe:samples" section
# The maximum Z distance (in mm) that a sample may differ from other
# samples. The default is from the probe's configuration.
#samples_tolerance: default from "probe:samples_tolerance" section
# The number of times to retry if a sample is found that exceeds
# samples_tolerance. The default is from the probe's configuration.
#samples_tolerance_retries: default from "probe:samples_tolerance_retries" section
# The calculation method when sampling more than once - either
# "median" or "average". The default is from the probe's configuration.
#samples_result: default from "probe:samples_result" section
# The distance in mm to move up before moving to the next
# position. The default is two times the z_offset from the probe's
# configuration.
clearance: 2
#position_min: default from "stepper_z:position_min" section.
# The moving speed in X and Y. The default is 50 mm/s.
speed: 300
# Speed (in mm/s) of the Z axis when lifting the probe between
# samples and clearance moves. The default is from the probe's
# configuration.
#lift_speed: default from "probe:lift_speed" section
# The fast probing speed (in mm/s) used, when probing_first_fast
# is activated. The default is from the Z rail configuration.
#probing_speed: default from "stepper_z:homing_speed" section.
# The slower speed (in mm/s) for probing the recorded samples.
# The default is second_homing_speed of the Z rail configuration.
#probing_second_speed: default from "stepper_z:second_homing_speed" section.
# Distance to backoff (in mm) before probing the next sample.
# The default is homing_retract_dist from the Z rail configuration.
#probing_retract_dist: default from "stepper_z:homing_retract_dist" section.
# If true, the first probing is done faster by the probing speed.
# This is to get faster down and the result is not recorded as a
# probing sample. The default is false.
probing_first_fast: true
# A list of G-Code commands to execute prior to each calibration command.
# See docs/Command_Templates.md for G-Code format. This can be used to
# attach the probe.
start_gcode: _SET_Z_CURRENT VAL=HOME
DETACH_PROBE
# A list of G-Code commands to execute prior to each probing on the
# mag-probe. See docs/Command_Templates.md for G-Code format. This can be
# used to attach the probe after probing on the nozzle and before probing
# on the mag-probe.
before_switch_gcode: ATTACH_PROBE
G0 Z20
# A list of G-Code commands to execute after each calibration command.
# See docs/Command_Templates.md for G-Code format. This can be used to
# detach the probe afterwards.
end_gcode: _SET_Z_CURRENT
DETACH_PROBE