Notifications
You must be signed in to change notification settings - Fork 35
/
Copy pathDOS2-FCS.TXT
2624 lines (1895 loc) · 113 KB
/
DOS2-FCS.TXT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
MSX-DOS 2 FUNCTION CODES SPECIFICATION
By ASCII corporation Japan
Supplied with COMPASS v1.0 by COMPJOETANIA
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
This manual describes in detail the MSX-DOS function calls provided by
MSX-DOS version 2.20.
1. INTRODUCTION
This document describes in detail each of the MSX-DOS 2 function calls. It
should be read in conjunction with the "Program Interface specification"
which describes system features such as file handles, fileinfo blocks and
environment strings in general terms.
There are two ways of doing MSX-DOS function calls, reflecting the two
different environments (MSX-DOS and disk BASIC) in which the system can run.
Transient programs running in the MSX-DOS environment must access the func-
tions with a "CALL 00005h" instruction. Disk BASIC and other MSX programs
running in the disk BASIC environment (usually executing from ROM) must ac-
cess the system via a "CALL 0F37Dh" instruction.
There are some limitations when calling the system via 0F37Dh, particu-
larly to do with error handling and abort routines. Also no parameters may be
passed in page-1, unless they are in the master disk ROM (as they will be for
disk BASIC) since the master disk ROM will be paged into page-1 when such a
function call is made. The individual function descriptions mention the dif-
ferences for particular functions.
2. LIST OF FUNCTIONS
Below there is a complete list of the functions calls. "CPM" indicates
that the function is compatible with the equivalent CP/M 2.2 function, "MSX1"
indicates compatibility with MSX-DOS version 1, and "NEW" indicates a func-
tion which is new to the MSX DOS 2.xx system. An asterisk ("*") indicates
that the function may be safely called from a user disk error routine (see
function 64h and function 70h).
List of MSX-DOS 2 Function Calls
CPM MSX1 00h - Program terminate
CPM MSX1* 01h - Console input
CPM MSX1* 02h - Console output
CPM MSX1* 03h - Auxiliary input
CPM MSX1* 04h - Auxiliary output
CPM MSX1* 05h - Printer output
CPM MSX1* 06h - Direct console I/O
MSX1* 07h - Direct console input
MSX1* 08h - Console input without echo
CPM MSX1* 09h - String output
CPM MSX1* 0Ah - Buffered line input
CPM MSX1* 0Bh - Console status
CPM MSX1* 0Ch - Return version number
CPM MSX1 0Dh - Disk reset
CPM MSX1 0Eh - Select disk
CPM MSX1 0Fh - Open file (FCB)
CPM MSX1 10h - Close file (FCB)
CPM MSX1 11h - Search for first entry (FCB)
CPM MSX1 12h - Search for next entry (FCB)
CPM MSX1 13h - Delete file (FCB)
CPM MSX1 14h - Sequential read (FCB)
CPM MSX1 15h - Sequential write FCB)
CPM MSX1 16h - Create file (FCB)
CPM MSX1 17h - Rename file (FCB)
CPM MSX1* 18h - Get login vector
CPM MSX1* 19h - Get current drive
CPM MSX1 1Ah - Set disk transfer address
MSX1 1Bh - Get allocation information
1Ch - Unused
1Dh - Unused
1Eh - Unused
1Fh - Unused
20h - Unused
CPM MSX1 21h - Random read (FCB)
CPM MSX1 22h - Random write(FCB)
CPM MSX1 23h - Get file size (FCB)
CPM MSX1 24h - Set random record (FCB)
25h - Unused
MSX1 26h - Random block write (FCB)
MSX1 27h - Random block read (FCB)
CPM MSX1 28h - Random write with zero fill (FCB)
29h - Unused
MSX1* 2Ah - Get date
MSX1* 2Bh - Set date
MSX1* 2Ch - Get time
MSX1* 2Dh - Set time
MSX1* 2Eh - Set/reset verify flag
MSX1* 2Fh - Absolute sector read
MSX1* 30h - Absolute sector write
NEW * 31h - Get disk parameters
32h - \
. . \ Unused
. . /
3Fh - /
NEW 40h - Find first entry
NEW 41h - Find next entry
NEW 42h - Find new entry
NEW 43h - Open file handle
NEW 44h - Create file handle
NEW 45h - Close file handle
NEW 46h - Ensure file handle
NEW 47h - Duplicate file handle
NEW 48h - Read from file handle
NEW 49h - Write to file handle
NEW 4Ah - Move file handle pointer
NEW 4Bh - I/O control for devices
NEW 4Ch - Test file handle
NEW 4Dh - Delete file or subdirectory
NEW 4Eh - Rename file or subdirectory
NEW 4Fh - Move file or subdirectory
NEW 50h - Get/set file attributes
NEW 51h - Get/set file date and time
NEW 52h - Delete file handle
NEW 53h - Rename file handle
NEW 54h - Move file handle
NEW 55h - Get/set file handle attributes
NEW 56h - Get/set file handle date and time
NEW * 57h - Get disk transfer address
NEW * 58h - Get verify flag setting
NEW 59h - Get current directory
NEW 5Ah - Change current directory
NEW 5Bh - Parse pathname
NEW 5Ch - Parse filename
NEW * 5Dh - Check character
NEW 5Eh - Get whole path string
NEW 5Fh - Flush disk buffers
NEW 60h - Fork a child process
NEW 61h - Rejoin parent process
NEW 62h - Terminate with error code
NEW 63h - Define abort exit routine
NEW 64h - Define disk error handler routine
NEW * 65h - Get previous error code
NEW * 66h - Explain error code
NEW 67h - Format a disk
NEW 68h - Create or destroy RAM disk
NEW 69h - Allocate sector buffers
NEW * 6Ah - Logical drive assignment
NEW * 6Bh - Get environment item
NEW * 6Ch - Set environment item
NEW * 6Dh - Find environment item
NEW * 6Eh - Get/set disk check status
NEW * 6Fh - Get MSX-DOS version number
NEW * 70h - Get/set redirection status
3. FUNCTION BY FUNCTION DEFINITIONS
Below are detailed descriptions of each of the MSX-DOS functions including
both the old and new ones. The names in brackets after the function numbers
are the public labels for the function codes which are defined in
"CODES.MAC". Programs should use these names whenever possible.
Many of the functions below 40h return an error flag rather than an error
code. If the error flag is set then the actual error code indicating the
cause of the error can be obtained by the "get previous error code" function
(function 65h). All of the functions above 40h return an error code in regis-
ter A. The "Program Interface Specification" document describes the general
errors which can be returned from many of the functions. The individual func-
tion specifications here describe the main error conditions which are speci-
fic to particular functions.
Note that many of the function calls which modify the information on a
disk do not automatically flush disk buffers and so the disk is not neces-
sarily correctly updated immediately after the function call is made. Such
calls include all types of "create", "write", "delete", "rename", "change
file attributes" and "change file date and time" function calls. The only
functions which always flush disk buffers are "flush buffers", "close" and
"ensure". After these ope rations the disk will always be correctly updated.
3.1 PROGRAM TERMINATE (00H)
Parameters: C = 00H (_TERM0)
Results: Does not return
This function terminates program with a zero return code. It is provided
for compatibility with MSX-DOS 1 and CP/M, the preferred method of exiting a
program is to use the "terminate with error code" function call (function
62h), passing a zero error code if that is what is desired. See the descrip-
tion of that function call, and also the "Program Interface Specification",
for details of what happens when a program terminates. This function call
never returns to the caller.
3.2 CONSOLE INPUT (01H)
Parameters: C = 01H (_CONIN)
Results: L=A = Character from keyboard
A character will be read from the standard input (file handle 0 - usually
the keyboard) and echoed to the standard output (file handle 1 - usually the
screen). If no character is ready then this function will wait for one.
Various control characters, as specified for the "console status" function
(function 0Bh), will be trapped by this function for various control pur-
poses. If one of these characters is detected then it will be processed and
wait for another character. Thus these characters will never be returned to
the user by this function.
3.3 CONSOLE OUTPUT (02H)
Parameters: C = 02H (_CONOUT)
E = Character to be output
Results: None
The character passed in register E is written to the standard output (file
handle 1 - usually the screen). If printer echo is enabled then the character
is also written to the printer. Various control codes and escape sequences
are interpreted as screen control codes. A list of these is included in the
"Program Interface Specification", they are a sub-set of the standard VT-52
control codes. TABs will be expanded to every eighth column.
A console input status check is done, and if any of the special control
characters described for the "console status" function (function 0Bh) is
found then it will be processed as for that function. Any other character
will be saved internally for a later "console input" function call.
3.4 AUXILIARY INPUT (03H)
Parameters: C = 03H (_AUXIN)
Results: L=A = Input character
A character is read from the auxiliary input device (file handle 3) and if
no character is ready then it will wait for one. The auxiliary input device
must have been installed before this function may be used. If no such device
has been installed then this function will always return the end of file
character ("Ctrl-Z").
3.5 AUXILIARY OUTPUT (04H)
Parameters: C = 04H (_AUXOUT)
E = Character to be output
Results: None
The character passed in register E will be written to the auxiliary output
device (file handle 3). The auxiliary output device must have been installed
before this function may be used. If no such device has been installed then
this function will simply throw the character away.
3.6 PRINTER OUTPUT (05H)
Parameters: C = 05H (_LSTOUT)
E = Character to be output
Results: None
The character passed in register E will be sent to the standard printer
device (file handle 4 - usually the parallel printer). The same channel is
used for console output which is echoed to the printer. TABs are not expanded
by thisfunction, although they are expanded when screen output is echoed to
the printer with "Ctrl-P".
3.7 DIRECT CONSOLE I/O (06H)
Parameters: C = 06H (_DIRIO)
E = 00H...FEH - character for output
= FFH - requests input
Results: A=L = input : 00H - no character ready
else input character
undefined for output
If E=FFh on entry then the keyboard will be examined for a character from
the standard input (file handle 0) and 00h returned if no character is ready.
If a character is ready then it will be read from the standard input (file
handle 0) and returned in register A without being echoed and with no check
for control characters.
If E<>FFh on entry then the character in register E will be printed direc-
tly to the standard output (file handle 1) with no TAB expansion or printer
echo. Also no console status check is done by this function. Note that
although this function does not expand TABs, the VT-52 control codes include
TAB expansion so the effect on the screen is the same.
3.8 DIRECT CONSOLE INPUT (07H)
Parameters: C = 07H (_DIRIN)
Results: L=A = Input character
This function is identical to the input option of function 06h, except
that if no character is ready it will wait for one. Like function 06h, no
echo or control characters checks will be done. This function is not compa-
tible with CP/M which uses this function number for "get I/O byte".
3.9 CONSOLE INPUT WITHOUT ECHO (08H)
Parameters: C = 08H (_INNOE)
Results: L=A = Input character
This function is identical to function 01h except that the input character
will not be echoed to the standard output. The same control character checks
will be done. This function is not compatible with CP/M which uses this func-
tion number for "set I/O byte".
3.10 STRING OUTPUT (09H)
Parameters: C = 09H (_STROUT)
DE = Address of string
Results: None
The characters of the string pointed to by register DE will be output
using the normal console output routine (function call 02h). The string is
terminated by "$" (ASCII 24h).
3.11 BUFFERED LINE INPUT (0AH)
Parameters: C = 0AH (_BUFIN)
DE = Address of an input buffer
Results: None
DE must point to a buffer to be used for input. The first byte of this
buffer must contain the number of characters which the buffer can hold
(0...255). A line of input will be read from the standard input device (file
handle 0 - usually the keyboard) and stored in the buffer. The input will be
terminated when a CR is read from the standard input. The number of charac-
ters entered, which does not include the CR itself, will be stored at (DE+1).
If there is room in the buffer then the CR will be stored after the last
character.
When inputting from the keyboard (which will normally be the case), a
simple line editor is provided, and also a 256 byte circular buffer of pre-
vious lines which can be edited and re-entered. The details of these editing
facilities are described in the separate "Command Specification" document, so
they are not included here. When the input buffer becomes full, the console
bell will be rung for each character typed which cannot be put in the buffer.
Each character entered will be echoed to the standard output and also to the
printer if printer echo is enabled.
3.12 CONSOLE STATUS (0BH)
Parameters: C = 0BH (_CONST)
Results: L=A = 00H if no key was pressed
= FFH if a key was pressed
A flag is returned in register A to indicate whether a character is ready
(that is, a key was pressed) for input from the keyboard. If a character is
ready then it will be read and tested for certain special control characters.
If it is not one of these then it is stored in an internal single byte buffer
and subsequent call to this function will return "character ready" immedia-
tely without checking the keyboard. If this function says that a character is
ready then the character may be read by function 02h or 08h.
If the character is "Ctrl-C" then the program will be terminated with a
".CTRLC" error via the user's abort routine if one is defined. If the charac-
ter is "Ctrl-P" then printer echo will be enabled and it will be disabled if
it is "Ctrl-N". If the character is "Ctrl-S" then the routine will hang up
waiting for another character to be pressed and thenreturn "no character
ready", thus providing a "wait" facility. The character typed to continue
operation will be ignored, except that of it is "Ctrl-C" then the program
will be terminated. These same input checks are also done for functions 01h,
02h, 08h, 09h and 0Ah.
3.13 RETURN VERSION NUMBER (0CH)
Parameters: C = 0CH (_CPMVER)
Results: L=A = 22H
H=B = 00H
This function simply returns the CP/M version number which is being emu-
lated. This is always version 2.2 in current systems.
3.14 DISK RESET (0DH)
Parameters: C = 0DH (_DSKRST)
Results: None
Any data which is waiting in internal buffers is written out to disk. It
is not necessary to call this function in order to allow a disk change as is
the case with CP/M. The disk transfer address is also set back to its default
value of 80h by this function.
3.15 SELECT DISK (0EH)
Parameters: C = 0EH (_SELDSK)
E = Drive number. 0=A: 1=B: etc.
Results: L=A = Number of drives (1...8)
This function simply selects the specified drive as the default drive. The
current drive is also stored at address 0004h for CP/M compatibility. The
number of drives available is returned in register A but this will not in-
clude the RAMdisk.
3.16 OPEN FILE [FCB] (0FH)
Parameters: C = 0FH (_FOPEN)
DE = Pointer to unopened FCB
Results: L=A = 0FFH if file not found
= 0 if file is found
The unopened FCB must contain a drive which may be zero to indicate the
current drive and a filename and extension which may be ambiguous. The cur-
rent directory of the specified drive will be searched for a matching file
and if found it will be opened. Matching entries which are sub-directories or
system files will be ignored, and if the filename is ambiguous then the first
suitable matching entry will be opened.
Device names may be put in the FCB (without a colon) to allow devices to
be accessed as if they were actually disk files. The standard device names
are defined in the "Program Interface Specification".
The low byte of the extent number is not altered by this function, and a
file will only be opened if it is big enough to contain the specified extent.
Normally the transient program will set the extent number to zero before
calling this function. The high byte of the extent number will be set to zero
to ensure compatibility with CP/M.
The filename and extension in the FCB will be replaced by the actual name
of the file opened from the directory entry. This will normally be the same
as what was there before but may be different if an ambiguous filename or one
with lower case letters in was used.
The record count will be set to the number of 128 byte records in the
specified extent, which is calculated from the file size. The file size field
itself, the volume-id and the 8 reserved bytes will also be set up. The cur-
rent record and random record fields will not be altered by this function, it
is the application program's responsibility to initialize them before using
the read or write functions.
If the file cannot be found, then the "APPEND" environment item will be
examined. If this is set then it is interpreted as a drive/path string which
specifies a second directory in which to look for the file. The specified
directory will be searched for the file and if found it will be opened as
above. In this case the drive byte of the FCB will be set to the drive on
which the file was found to ensure correct accessing of the file if the ori-
ginal drive byte was zero (default).
3.17 CLOSE FILE [FCB] (10H)
Parameters: C = 10H (_FCLOSE)
DE = Pointer to opened FCB
Results: L=A = 0FFH if not successful
= 0 if successful
The FCB must have previously been opened with either an OPEN or a CREATE
function call. If the file has only been read then this function does
nothing. If the file has been written to then any buffered data will be writ-
ten to disk and the directory entry updated appropriately. The file may still
be accessed after a close, so the function can be regarded as doing an
"ensure" function.
3.18 SEARCH FOR FIRST [FCB] (11H)
Parameters: C = 11H (_SFIRST)
DE = Pointer to unopened FCB
Results: L=A = 0FFH if file not found
= 0 if file found.
This function searches the current directory of the drive specified in the
FCB (default drive if FCB contains zero) for a file which matches the file-
name and extension in the FCB. The filename may be ambiguous (containing "?"
characters) in which case the first match will be found. The low byte of the
extent field will be used, and a file will only be found if it is big enough
to contain this extent number. Normally the extent field will be set to zero
by the program before calling this function. System file and sub-directory
entries will not be found.
If a suitable match is found (A=0) then the directory entry will be copied
to the DTA address, preceded by the drive number. This can be used directly
as an FCB for an OPEN function call if desired. The extent number will be set
to the low byte of the extent from the search FCB, and the record count will
be initialized appropriately (as for OPEN). The attributes byte from the
directory entry will be stored in the S1 byte position, since its normal
position (immediately after the filename extension field) is used for the
extent byte.
If no match is found (A=0FFh) then the DTA will not be altered. In no case
will the FCB pointed to by DE be modified at all. This function remembers
sufficient information internally to allow it to continue the search with a
SEARCH FOR NEXT function, so it is not necessary for the FCB to be preserved
if doing a SEARCH FOR NEXT function.
In CP/M, if the drive number is set to "?" in this function then all
directory entries, allocated or free will be matched. Also if the extent
field is set to "?" then any extent of a file will be matched. Both of these
features are normally only used by special purpose CP/M programs which are
generally specific to the CP/M filing system (such as "STAT"). Neither fea-
ture is present in MSX-DOS 1/2.
3.19 SEARCH FOR NEXT [FCB] (12H)
Parameters: C = 12H (_SNEXT)
Results: L=A = 0FFH if file not found
= 0 if file found.
It continues the search to look for the next match with the filename. The
results returned from this function are identical to SEARCH FOR FIRST and all
the same comments apply. The information used to continue the search is held
internally within MSX-DOS and so the original FCB used in the SEARCH FOR
FIRST need not still exist.
3.20 DELETE FILE [FCB] (13H)
Parameters: C = 13H (_FDEL)
DE = Pointer to unopened FCB
Results: L=A = 0FFH if no files deleted
= 0 if files deleted OK
All files in the current directory of the disk specified by the FCB, and
which match the ambiguous filename in the FCB, are deleted. Sub-directories,
system files, hidden files and read only files are not deleted. If any files
at all are successfully deleted then this function returns with A=0. A return
with A=FFh indicates that no files were deleted.
3.21 SEQUENTIAL READ [FCB] (14H)
Parameters: C = 14H (_RDSEQ)
DE = Pointer to opened FCB
Results: L=A = 01H if error (end of file)
= 0 if read was successful
This function reads the next sequential 128 byte record from the file into
the current disk transfer address. The record is defined by the current ex-
tent (high and low bytes) and the current record. After successfully reading
the record, this function increments the current record and if it reaches
080h, sets it back to zero and increments the extent number. The record count
field is also kept updated when necessary.
Unlike CP/M it is possible to have partially filled records, since the
file size is not necessarily a multiple of 128 bytes. If this occurs then the
partial record is padded out with zeroes when it is copied to the transient
program's DTA address.
3.22 SEQUENTIAL WRITE [FCB] (15H)
Parameters: C = 15H (_WRSEQ)
DE = Pointer to opened FCB
Results: L=A = 01H if error (disk full)
= 0 if write was successful
This function writes the 128 bytes from the current disk transfer address
to the file at the position defined by the current record and extent, which
are then incremented appropriately. The record count byte is kept updated
correctly if the file is extended or if the write moves into a new extent.
The file size in the FCB is also updated if the file is extended.
3.23 CREATE FILE [FCB] (16H)
Parameters: C = 16H (_FMAKE)
DE = Pointer to unopened FCB
Results: L=A = 0FFH if unsuccessful
= 0 if successful
This function creates a new file in the current directory of the specified
drive and opens it ready for reading and writing. The drive, filename and low
byte of the extent number must be set up in the FCB and the filename must not
be ambiguous. Checks will be done to ensure that invalid filenames are not
created.
If there is already a file of the required name then the action depends on
the value of the extent number byte. Normally this will be zero and in this
case the old file will be deleted and a new one created. However if the ex-
tent number is non-zero then the existing file will be opened without crea-
ting a new file. This ensures compatibility with early versions of CP/M where
each extent had to be explicitly created.
In all cases the resulting file will be opened with the required extent
number exactly as if an OPEN function call had been done.
3.24 RENAME FILE [FCB] (17H)
Parameters: C = 17H (_FREN)
DE = Pointer to unopened FCB
Results: L=A = 0FFH if not successful
= 0 if successful
The unopened FCB has the normal drive and filename, and also a second
filename starting at (DE+17). Every file in the current directory of the
specified drive which matches the first filename, is changed to the second
filename with "?" characters in the second filename leaving the appropriate
character unchanged. Checks are done to prevent duplicate or illegal file-
names from being created. Entries for sub-directories, hidden files and sys-
tem files will not be renamed.
3.25 GET LOGIN VECTOR (18H)
Parameters: C = 18H (_LOGIN)
Results: HL = Login vector
This function returns a bit set in HL for each drive which is available,
bit-0 of L corresponding to drive "A:". Up to eight drives ("A:" to "H:") are
supported by the system currently, so register H will usually be zero on
return.
3.26 GET CURRENT DRIVE (19H)
Parameters: C = 19H (_CURDRV)
Results: L=A = Current drive (0=A: etc)
This function just returns the current drive number.
3.27 SET DISK TRANSFER ADDRESS (1AH)
Parameters: C = 1AH (_SETDTA)
DE = Required Disk Transfer Address
Results: None
This function simply records the address passed in DE as the disk transfer
address. This address will be used for all subsequent FCB read and write
calls, for "search for first" and "search for next" calls to store the direc-
tory entry, and for absolute read and write calls. It is not used by the new
MSX-DOS read and write functions. The address is set back to 80h by a DISK
RESET call.
3.28 GET ALLOCATION INFORMATION (1BH)
Parameters: C = 1BH (_ALLOC)
E = Drive number (0=current, 1=A: etc)
Results: A = Sectors per cluster
BC = Sector size (always 512)
DE = Total clusters on disk
HL = Free clusters on disk
IX = Pointer to DPB
IY = Pointer to first FAT sector
This function returns various information about the disk in the specified
drive. It is not compatible with CP/M which uses this function number to
return the address of an allocation vector. Note that unlike MSX-DOS 1, only
the first sector of the FAT may be accessed from the address in IY, and the
data there will only remain valid until the next MSX-DOS call.
3.29 RANDOM READ [FCB] (21H)
Parameters: C = 21H (_RDRND)
DE = Pointer to opened FCB
Results: L=A = 01H if error (end of file)
= 0 if read was successful
This function reads a 128 byte record from the file to the current disk
transfer address. The file position is defined by the three byte random re-
cord number in the FCB (bytes 21h...23h). Unlike CP/M all three bytes of the
random record number are used. A partial record at the end of the file will
be padded with zeroes before being copied to the user's DTA.
The random record number is not altered so successive calls to this func-
tion will read the same record unless the transient program alters the random
record number. A side effect is that the current record and extent are set up
to refer to the same record as the random record number. This means that
sequential reads (or writes) can follow a random read and will start from the
same record. The record count byte is also set up correctly for the extent.
3.30 RANDOM WRITE [FCB] (22H)
Parameters: C = 22H (_WRRND)
DE = Pointer to opened FCB
Results: L=A = 01H if error (disk full)
= 0 if no error
This function writes a 128 byte record from the current disk transfer
address to the file, at the record position specified by the three byte ran-
dom record number (bytes 21h...23h). All three bytes of the random record
number are used. If the record position is beyond the current end of file
then un-initialized disk space will be allocated to fill the gap.
The random record number field will not be changed, but the current record
and extent fields will be set up to refer to the same record. The record
count byte will be adjusted as necessary if the file is being extended or if
the write goes into a new extent.
3.31 GET FILE SIZE [FCB] (23H)
Parameters: C = 23H (_FSIZE)
DE = Pointer to unopened FCB
Results: L=A = 0FFH if file not found
= 0 if file found OK
This function searches for the first match with the filename in the FCB,
exactly the same as OPEN FILE (function 0FH). The size of the located file is
rounded up to the nearest 128 bytes and the number of records determined. The
three byte random record field of the FCB is set to the number of records, so
it is the number of the first record which does not exist. The fourth byte of
the random record number is not altered.
3.32 SET RANDOM RECORD [FCB] (24H)
Parameters: C = 24H (_SETRND)
DE = Pointer to opened FCB
Results: None
This function simply sets the three byte random record field in the FCB to
the record determined by the current record and extent number. The fourth
byte of the random record number is not altered. No check is done as to whe-
ther the record actually exists in the file.
3.33 RANDOM BLOCK WRITE [FCB] (26H)
Parameters: C = 26H (_WRBLK)
DE = Pointer to opened FCB
HL = Number of records to write
Results: A = 01H if error
= 0 if no error
Data is written from the current disk transfer address to the position in
the file defined by the random record number. The record size is determined
by the record size field in the FCB (bytes 0Eh and 0Fh) which must be set by
the user after opening the file and before calling this function. If the
record size is less than 64 bytes then all four bytes of the random record
number are used, otherwise only the first three are used.
The number of records to be written is specified by HL, and together with
the record size this determines the amount of data to be written. An error
will be returned if the size exceeds 64k, thus limiting the maximum size of a
transfer.
After writing the data, the random record field is adjusted to the next
record number in the file (ie. HL is added on to it). The current record and
extent fields are not used or altered. The file size field is updated if the
file has been extended.
The record size can be any value from 1...0FFFFh. Small record sizes are
no less efficient that large record sizes so if desired the record size can
be set to one and the record count then becomes a byte count. It is desirable
to write as much as possible with one function call since one large transfer
will be quicker than several small ones.
If the number of records to write (HL) is zero then no data will be writ-
ten, but the size of the file will be altered to the value specified by the
random record field. This may be either longer or shorter than the file's
current size and disk space will be allocated or freed as required. Additio-
nal disk space allocated in this way will not be initialized to any particu-
lar value.
3.34 RANDOM BLOCK READ [FCB] (27H)
Parameters: C = 27H (_RDBLK)
DE = Pointer to opened FCB
HL = Number of records to read
Results: A = 01H if error (usually caused by
end-of-file)
= 0 if no error
HL = Number of records actually read
This function is the complement of the BLOCK WRITE function described
above and most of the same comments apply as regards its use. Again if large
blocks are read then it will be much faster than the normal CP/M operation.
For example if it is desired to read 20k from a file, it is better to read
the 20k with one function call rather than 20 separate function calls of 1k
each. However it makes no difference whether the 20k read is done with a
record size of 1 and a record count of 20k, with a record size of 20k and a
record count of 1, or any intermediate combination.
The number of records actually read is returned in HL. This may be smaller
than the number of records requested if the end of the file was encountered.
In this case any partial record will be padded out with zeroes before being
copied to the users DTA. The random record field is adjusted to the first
record not read, ie. the value returned in HL is added on to it.
3.35 RANDOM WRITE WITH ZERO FILL [FCB] (28H)
Parameters: C = 28H (_WRZER)
DE = Pointer to opened FCB
Results: L=A = 01H if error
= 00H if no error
This function is identical to RANDOM WRITE (function 22h) except that if
the file has to be extended, any extra allocated disk clusters will be filled
with zeroes before writing the data.
3.36 GET DATE (2AH)
Parameters: C = 2AH (_GDATE)
Results: HL = Year 1980...2079
D = Month (1=Jan...12=Dec)
E = Date (1...31)
A = Day of week (0=Sun...6=Sat)
This function simply returns the current value of the internal calender in
the format shown.
3.37 SET DATE (2BH)
Parameters: C = 2BH (_SDATE)
HL = Year 1980...2079
D = Month (1=Jan...12=Dec)
E = Date (1...31)
Results: A = 00H if date was valid
FFH if date was invalid
The supplied date is checked for validity and if it is valid then it is
stored as the new date. The validity checks include full checking for the
number of days in each month and leap years. If the date is invalid then the
current date will be left unaltered. The date is stored in the real time
clock chip so it will be remembered when the machine is turned off.
3.38 GET TIME (2CH)
Parameters: C = 2CH (_GTIME)
Results: H = Hours (0...23)
L = Minutes (0...59)
D = Seconds (0...59)
E = Centiseconds (always zero)
This function returns the current value of the system clock in the format
shown.
3.39 SET TIME (2DH)
Parameters: C = 2DH (_STIME)
H = Hours (0...23)
L = Minutes (0...59)
D = Seconds (0...59)
E = Centiseconds (ignored)
Results: A = 00H if time was valid
FFH if time was invalid
This function sets the internal system clock to the specified time value.
If the time is invalid then register A will be returned as 0FFh to indicate
an error and the current time will be left unaltered. The time is stored in
the real time clock chip and so it will be remembered and kept correct when
the machine is turned off.
3.40 SET/RESET VERIFY FLAG (2EH)
Parameters: C = 2EH (_VERIFY)
E = 0 to disable verify
<> 0 to enable verify
Results: None
This function simply enables or disables automatic verification of all
writes. It defaults to off when MSX-DOS is started up. Enabling verify im-
proves system reliability but also slows down write operations. Note that
this function depends on the disk driver and the verification will not be
done if the driver does not support it.
3.41 ABSOLUTE SECTOR READ (2FH)
Parameters: C = 2FH (_RDABS)
DE = Sector number
L = Drive number (0=A: etc.)
H = Number of sectors to read
Results: A = Error code (0=> no error)
This function reads sectors directly from the disk without interpreting
them as files. The disk must be a valid DOS disk in order for the sector
number to be translated into a physical position on the disk. The sectors
will be read to the current disk transfer address. Any disk error will be
reported by the system in the usual way.
3.42 ABSOLUTE SECTOR WRITE (30H)
Parameters: C = 30H (_WRABS)
DE = Sector number
L = Drive number (0=A: etc.)
H = Number of sectors to write
Results: A = Error code
This function writes sectors directly to the disk without interpreting
them as files. The disk must be a valid DOS disk in order for the sector
number to be translated into a physical position on the disk. The sectors
will be written from the current disk transfer address. Any disk errors are
reported by the system in the usual way.
3.43 GET DISK PARAMETERS (31H)