forked from meesokim/msx-cartridge
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathrpmpv1.rules
102 lines (101 loc) · 2.35 KB
/
rpmpv1.rules
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
(rules PCB rpmpv1
(snap_angle
fortyfive_degree
)
(autoroute_settings
(fanout off)
(autoroute on)
(postroute on)
(vias on)
(via_costs 50)
(plane_via_costs 5)
(start_ripup_costs 100)
(start_pass_no 6230)
(layer_rule F.Cu
(active on)
(preferred_direction horizontal)
(preferred_direction_trace_costs 1.0)
(against_preferred_direction_trace_costs 2.0)
)
(layer_rule B.Cu
(active on)
(preferred_direction vertical)
(preferred_direction_trace_costs 1.0)
(against_preferred_direction_trace_costs 2.0)
)
)
(rule
(width 250.0)
(clear 200.2)
(clear -0.1 (type smd_to_turn_gap))
(clear 50.0 (type smd_smd))
)
(padstack "Via[0-1]_600:400_um"
(shape
(circle F.Cu 600.0 0.0 0.0)
)
(shape
(circle B.Cu 600.0 0.0 0.0)
)
(attach off)
)
(via
"Via[0-1]_600:400_um" "Via[0-1]_600:400_um" default
)
(via
"Via[0-1]_600:400_um-kicad_default" "Via[0-1]_600:400_um" "kicad_default"
)
(via
"Via[0-1]_600:400_um-5V" "Via[0-1]_600:400_um" 5V
)
(via_rule
default "Via[0-1]_600:400_um"
)
(via_rule
"kicad_default" "Via[0-1]_600:400_um-kicad_default"
)
(via_rule
5V "Via[0-1]_600:400_um-5V"
)
(class default
(clearance_class default)
(via_rule default)
(rule
(width 250.0)
)
(circuit
(use_layer F.Cu B.Cu)
)
)
(class "kicad_default"
GND /RD3 /RD4 /RD6 /RD7 /RD0 /RCLK /RD1
/RD2 /RD5 /WAIT /INT /BUSDIR /IORQ /MREQ /WR
/RD /RESET /A9 /A15 /A11 /A10 /A7 /A6
/A12 /A8 /A14 /A13 /A1 /A0 /A3 /A2
/A5 /A4 /D1 /D0 /D3 /D2 /D5 /D4
/D7 /D6 /CLK +3V3 /RINT /RWAIT "Net-(P1-Pad5)" "Net-(P1-Pad16)"
/RA8 /RA10 /RA11 /RA15 "/LE_A" "/LE_B" /RA12 /RA9
/RA13 /RA14 /RBUSDIR "Net-(J1-Pad13)" "Net-(J1-Pad37)" "Net-(P1-Pad1)" "Net-(P1-Pad2)" "Net-(P1-Pad3)"
/SLTSL "Net-(P1-Pad6)" "Net-(P1-Pad44)" "Net-(P1-Pad48)" "Net-(P1-Pad50)" "Net-(U4-Pad2)" "Net-(U4-Pad18)" /RRESET
/M1 "Net-(J2-Pad13)" "Net-(J2-Pad37)" /SOUNDIN "Net-(C1-Pad1)" /BCK /LRCK /DOUT
(clearance_class "kicad_default")
(via_rule kicad_default)
(rule
(width 250.0)
)
(circuit
(use_layer F.Cu B.Cu)
)
)
(class 5V
+5V
(clearance_class 5V)
(via_rule 5V)
(rule
(width 400.0)
)
(circuit
(use_layer F.Cu B.Cu)
)
)
)