temperature #6

Open
BaxiaAza opened this issue Sep 3, 2021 · 3 comments
Open

temperature #6

BaxiaAza opened this issue Sep 3, 2021 · 3 comments

Comments

@BaxiaAza
Copy link

BaxiaAza commented Sep 3, 2021

I really appreciate your OpenMPIData, but i want to know the absolute temperature of the scanner tube during the data acquisition, and which type of perimag did you adopt, plain, NH2, COOH or streptavidin? Looking forward to your reply!

@tknopp
Copy link
Member

tknopp commented Sep 3, 2021

That is hard to know since we did not measure the temperature. Certainly it was room temperature (20-22 degree). Perimag was plain.

@BaxiaAza
Copy link
Author

BaxiaAza commented Sep 3, 2021

Thanks for your explain. I have another question, was the perimag solution in the delta sample diluted to 100mmol(Fe)/L or not?diluted by water?

@mgraeser
Copy link

mgraeser commented Sep 3, 2021

All dilutions were made with water. The original concentration from micromod was higher, so yes they were diluted.