Skip to content

Latest commit

 

History

History
127 lines (93 loc) · 7.4 KB

07752L.md

File metadata and controls

127 lines (93 loc) · 7.4 KB
title description addedAt pageClass
Immax 07752L control via MQTT
Integrate your Immax 07752L via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2023-09-01 06:40:11 -0700
device-page

Immax 07752L

Model 07752L
Vendor Immax
Description NEO smart internal double socket
Exposes switch (state), power_outage_memory, indicator_mode, power, current, voltage, energy, lock (state), linkquality
Picture Immax 07752L

Options

How to use device type specific configuration

  • power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.

  • power_precision: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • current_calibration: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.

  • current_precision: Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.

  • voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.

  • energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • state_action: State actions will also be published as 'action' when true (default false). The value must be true or false

Exposes

Switch (l1 endpoint)

The current state of this switch is in the published state under the state_l1 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l1": "ON"}, {"state_l1": "OFF"} or {"state_l1": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state_l1": ""}.

On with timed off

When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time and off_wait_time to work Examples : {"state" : "ON", "on_time": 300}, {"state" : "ON", "on_time": 300, "off_wait_time": 120}.

Switch (l2 endpoint)

The current state of this switch is in the published state under the state_l2 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l2": "ON"}, {"state_l2": "OFF"} or {"state_l2": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state_l2": ""}.

On with timed off

When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time and off_wait_time to work Examples : {"state" : "ON", "on_time": 300}, {"state" : "ON", "on_time": 300, "off_wait_time": 120}.

Power outage memory (enum)

Recover state after power outage. Value can be found in the published state on the power_outage_memory property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"power_outage_memory": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_outage_memory": NEW_VALUE}. The possible values are: on, off, restore.

Indicator mode (enum)

LED indicator mode. Value can be found in the published state on the indicator_mode property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"indicator_mode": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"indicator_mode": NEW_VALUE}. The possible values are: off, off/on, on/off, on.

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.

Current (numeric)

Instantaneous measured electrical current. Value can be found in the published state on the current property. It's not possible to read (/get) or write (/set) this value. The unit of this value is A.

Voltage (numeric)

Measured electrical potential value. Value can be found in the published state on the voltage property. It's not possible to read (/get) or write (/set) this value. The unit of this value is V.

Energy (numeric)

Sum of consumed energy. Value can be found in the published state on the energy property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Child lock (lock)

The current state of this lock is in the published state under the child_lock property (value is LOCK or UNLOCK). To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"child_lock": "LOCK"} or {"child_lock": "UNLOCK"}. It's not possible to read (/get) this value.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.