\mainpage Main Page
ADC 20 Click is a compact add-on board with a high-performance data converter. This board features the TLA2518, an SPI-configurable eight-channel 12-bit successive approximation register analog-to-digital converter (SAR ADC) from Texas Instruments. The TLA2518 has an internal oscillator for the ADC conversion and supports averaging multiple data samples with a single conversion start. Also, the built-in programmable averaging filters help reduce noise from the analog inputs and reduce the number of data samples required to be read by the host MCU. All eight channels can be used as analog inputs, with the addition that the four channels can be used as digital inputs or digital outputs.
- Author : Stefan Filipovic
- Date : Oct 2022.
- Type : SPI type
We provide a library for the ADC 20 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
This library contains API for ADC 20 Click driver.
adc20_cfg_setup
Config Object Initialization function.
void adc20_cfg_setup ( adc20_cfg_t *cfg );
adc20_init
Initialization function.
err_t adc20_init ( adc20_t *ctx, adc20_cfg_t *cfg );
adc20_default_cfg
Click Default Configuration function.
err_t adc20_default_cfg ( adc20_t *ctx );
adc20_read_data
This function reads two bytes of data by using SPI serial interface.
err_t adc20_read_data ( adc20_t *ctx, uint16_t *data_out );
adc20_set_gpo_value
This function sets the gpo value for the selected channels.
err_t adc20_set_gpo_value ( adc20_t *ctx, uint8_t ch_mask, uint8_t value );
adc20_read_gpio_value
This function reads the gpio pins value.
err_t adc20_read_gpio_value ( adc20_t *ctx, uint8_t *gpio_value );
This example demonstrates the use of ADC 20 Click board by displaying the state of 8 channels configured as analog inputs (CH2-CH5), digital inputs (CH0-CH1) and digital outputs (CH6-CH7).
The demo application is composed of two sections :
Initializes the driver and performs the Click default configuration.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
adc20_cfg_t adc20_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
adc20_cfg_setup( &adc20_cfg );
ADC20_MAP_MIKROBUS( adc20_cfg, MIKROBUS_1 );
if ( SPI_MASTER_ERROR == adc20_init( &adc20, &adc20_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
if ( ADC20_ERROR == adc20_default_cfg ( &adc20 ) )
{
log_error( &logger, " Default configuration." );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
Starts the auto sequence mode, reads the 12bit ADC value from analog input channels (CH2-CH5) and displays the values converted to voltage on the USB UART. After that, stops auto sequence mode and toggles the state of digital output pins (CH6-CH7), then reads and displays the state of all GPIO pins.
void application_task ( void )
{
adc20_start_auto_sequence ( &adc20 );
for ( uint8_t ch_id = ADC20_CHANNEL_ID_2; ch_id <= ADC20_CHANNEL_ID_5; ch_id++ )
{
uint16_t adc_data = 0;
if ( ADC20_OK == adc20_read_data ( &adc20, &adc_data ) )
{
float voltage = ( float ) ( adc_data >> ADC20_ADC_OFFSET ) / ADC20_RES_12BIT * ADC20_VREF_3V3;
log_printf ( &logger, " AIN%u: %.2f V\r\n", ( adc_data & ADC20_CHANNEL_ID_MASK ), voltage );
}
}
adc20_stop_auto_sequence ( &adc20 );
static uint8_t out_logic_state = ADC20_GPIO_VALUE_LOW;
if ( ADC20_OK == adc20_set_gpo_value ( &adc20, ( ADC20_CHANNEL_6 | ADC20_CHANNEL_7 ), out_logic_state ) )
{
uint8_t gpio_value = 0;
if ( ADC20_OK == adc20_read_gpio_value ( &adc20, &gpio_value ) )
{
log_printf ( &logger, " GPIO state: 0x%.2X\r\n", gpio_value );
}
}
out_logic_state = !out_logic_state;
log_printf ( &logger, "\r\n" );
Delay_ms ( 1000 );
}
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Other Mikroe Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.ADC20
Additional notes and informations
Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.