\mainpage Main Page
IR Sense 5 Click is a compact add-on board designed for accurate, non-contact surface temperature measurement. This board features the ZTP-148SRC1, a thermopile IR sensor from Amphenol, with a measurement range from -20 to +100°C, an active area of 0.7x0.7mm², and a typical field of view of 85 degrees. The board also integrates an OPA2365AIDR OpAmp for signal amplification and an MCP3221 analog-to-digital converter for digitizing the output. Additional features include output offset selection and test points for signal monitoring.
- Author : Nenad Filipovic
- Date : Feb 2024.
- Type : ADC/I2C type
We provide a library for the IR Sense 5 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
This library contains API for IR Sense 5 Click driver.
irsense5_cfg_setup
Config Object Initialization function.
void irsense5_cfg_setup ( irsense5_cfg_t *cfg );
irsense5_init
Initialization function.
err_t irsense5_init ( irsense5_t *ctx, irsense5_cfg_t *cfg );
irsense5_get_obj_temp
This function reads and calculate object temperature in degree Celsius [degC].
err_t irsense5_get_obj_temp ( irsense5_t *ctx, float *obj_temp );
irsense5_get_amb_temp
This function reads and calculate ambient temperature in degree Celsius [degC].
err_t irsense5_get_amb_temp ( irsense5_t *ctx, float *amb_temp );
irsense5_read_raw_adc_thm
This function reads the thermistor raw ADC value.
err_t irsense5_read_raw_adc_thm ( irsense5_t *ctx, uint16_t *raw_adc );
This library contains API for the IR Sense 5 Click driver for measuring ambient and object temperature.
The demo application is composed of two sections :
The initialization of the I2C and ADC module and log UART.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
irsense5_cfg_t irsense5_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
irsense5_cfg_setup( &irsense5_cfg );
IRSENSE5_MAP_MIKROBUS( irsense5_cfg, MIKROBUS_1 );
err_t init_flag = irsense5_init( &irsense5, &irsense5_cfg );
if ( ( ADC_ERROR == init_flag ) || ( I2C_MASTER_ERROR == init_flag ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
The demo application measures ambient and object temperature in degrees Celsius. Results are being sent to the UART Terminal, where you can track their changes.
void application_task ( void )
{
float temperature = 0;
if ( IRSENSE5_OK == irsense5_get_amb_temp ( &irsense5, &temperature ) )
{
log_printf( &logger, " Ambient Temperature: %.2f [degC]\r\n", temperature );
Delay_ms ( 1000 );
}
if ( IRSENSE5_OK == irsense5_get_obj_temp ( &irsense5, &temperature ) )
{
log_printf( &logger, " Object Temperature: %.2f [degC]\r\n\n", temperature );
Delay_ms ( 1000 );
}
}
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Other Mikroe Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.IRSense5
Additional notes and informations
Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.