Skip to content

Latest commit

 

History

History

thermo24

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 
 
 
 
 
 
 

\mainpage Main Page


Thermo 24 Click

Thermo 24 Click is a compact add-on board that contains the 4th generation temperature sensing solution from Sensirion. This board features the STS40, a high-accuracy ultra-low-power temperature sensor. The STS40 integrates a digital temperature sensor with a 16-bit analog-to-digital converter (ADC), a data processing circuit, and serial interface logic functions in one package. Characterized by its high accuracy (up to ±0.2°C typical) and high resolution of 0.01°C, this temperature sensor provides temperature data to the host controller with a configurable I2C interface.

Click Product page


Click library

  • Author : Stefan Filipovic
  • Date : Mar 2022.
  • Type : I2C type

Software Support

We provide a library for the Thermo 24 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Thermo 24 Click driver.

Standard key functions :

  • thermo24_cfg_setup Config Object Initialization function.
void thermo24_cfg_setup ( thermo24_cfg_t *cfg );
  • thermo24_init Initialization function.
err_t thermo24_init ( thermo24_t *ctx, thermo24_cfg_t *cfg );

Example key functions :

  • thermo24_soft_reset This function performs the software reset by sending the soft reset command by using I2C serial interface.
err_t thermo24_soft_reset ( thermo24_t *ctx );
  • thermo24_read_serial This function reads the 4-byte chip serial number by using I2C serial interface.
err_t thermo24_read_serial ( thermo24_t *ctx, uint32_t *serial_num );
  • thermo24_read_temperature This function reads the temperature in Celsius with the specified measurement precision.
err_t thermo24_read_temperature ( thermo24_t *ctx, uint8_t precision, float *temperature );

Example Description

This example demonstrates the use of Thermo 24 Click board by reading and displaying the temperature measurements.

The demo application is composed of two sections :

Application Init

Initializes the driver and logger, then performs the software reset of the Click board and reads and displays its serial number.

void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    thermo24_cfg_t thermo24_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    thermo24_cfg_setup( &thermo24_cfg );
    THERMO24_MAP_MIKROBUS( thermo24_cfg, MIKROBUS_1 );
    if ( I2C_MASTER_ERROR == thermo24_init( &thermo24, &thermo24_cfg ) ) 
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }
    
    if ( THERMO24_ERROR == thermo24_soft_reset ( &thermo24 ) )
    {
        log_error( &logger, " Software reset." );
        for ( ; ; );
    }

    uint32_t serial_num;
    if ( THERMO24_OK == thermo24_read_serial ( &thermo24, &serial_num ) )
    {
        log_printf ( &logger, " Serial Number: 0x%.8LX\r\n", serial_num );
    }
    log_info( &logger, " Application Task " );
}

Application Task

Reads the temperature measurement in Celsius and displays the results on the USB UART approximately once per second.

void application_task ( void )
{
    float temperature;
    if ( THERMO24_OK == thermo24_read_temperature ( &thermo24, THERMO24_MEASURE_PRECISION_HIGH, &temperature ) )
    {
        log_printf ( &logger, " Temperature: %.2f C\r\n\n", temperature );
        Delay_ms ( 1000 );
    }
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Thermo24

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.