diff --git a/src/inputs.jl b/src/inputs.jl index c2401d2..ba64d32 100644 --- a/src/inputs.jl +++ b/src/inputs.jl @@ -58,19 +58,19 @@ Base.@kwdef mutable struct InputsStruct ##### These are the exact /GhpGhx POST names from the API ##### # Parameters heat_pump_configuration::String = "WSHP" # "WSHP" or "WWHP" - borehole_depth_ft::Float64 = 443.0 # old value = 400, ResStock = 152m, ComStock and URBANopt = 135m = 443 ft - ghx_header_depth_ft::Float64 = 6.6 # old value = 4.0 # ResStock, ComStock, and URBANopt value is 2m = 6.56168 ft + borehole_depth_ft::Float64 = 443.0 # ResStock = 152m, ComStock and URBANopt = 135m = 443 ft + ghx_header_depth_ft::Float64 = 6.6 # ResStock, ComStock, and URBANopt value is 2m = 6.56168 ft borehole_spacing_ft::Float64 = 20.0 - borehole_diameter_inch::Float64 = 6.0 # old value = 5 inch, ResStock, ComStock, and URBANopt value is 6 inch + borehole_diameter_inch::Float64 = 6.0 # ResStock, ComStock, and URBANopt value is 6 inch borehole_spacing_type::String = "rectangular" # "rectangular" or "hexagonal" ghx_pipe_outer_diameter_inch::Float64 = 1.66 ghx_pipe_wall_thickness_inch::Float64 = 0.16 - ghx_pipe_thermal_conductivity_btu_per_hr_ft_f::Float64 = 0.23 # Old value = 0.25 = 0.43 W/m-K. ReStock, ComStock and URBANopt value is 0.4 W/m-K which is 0.23127039296 BTU/ft-F - ghx_shank_space_inch::Float64 = 1.27 # old value = 2.5, ResStock = 0.0246m = 0.97 inch, ComStock & URBANopt = 0.0323m = 1.27 inch. Goes with ComStock & URBANopt value + ghx_pipe_thermal_conductivity_btu_per_hr_ft_f::Float64 = 0.23 # ReStock, ComStock and URBANopt value is 0.4 W/m-K which is 0.23127039296 BTU/ft-F + ghx_shank_space_inch::Float64 = 1.27 # ResStock = 0.0246m = 0.97 inch, ComStock & URBANopt = 0.0323m = 1.27 inch. Goes with ComStock & URBANopt value ground_thermal_conductivity_btu_per_hr_ft_f::Float64 = NaN # Default depends on climate zone ground_mass_density_lb_per_ft3::Float64 = 162.3 ground_specific_heat_btu_per_lb_f::Float64 = 0.211 - grout_thermal_conductivity_btu_per_hr_ft_f::Float64 = 0.75 # old value = 1.0, ResStock, ComStock, URBANopt value = 1.3 W/m-K = 0.75 BTU/ft-F + grout_thermal_conductivity_btu_per_hr_ft_f::Float64 = 0.75 # ResStock, ComStock, URBANopt value = 1.3 W/m-K = 0.75 BTU/ft-F ghx_fluid_specific_heat_btu_per_lb_f::Float64 = 1.0 ghx_fluid_mass_density_lb_per_ft3::Float64 = 62.4 ghx_fluid_thermal_conductivity_btu_per_hr_ft_f::Float64 = 0.34