2024-12-01 foenich
Corrected silkscreen printing on J1 and J8
No extra version released as schematic and function is not affected and nobody ever used V1.1.1 yet
2024-11-16 foenich
Released Version 1.1.1
Updated MOSFETS for power outputs (more current at low UGS)
* changed type of Q25-Q32 (same package, no change in layout)
2024-10-04 foenich
Released Version 1.1.0
Jumpers for RS485 bias and termination. Adjusted bias resistors.
Prevented current from USB to 5V_IN.
+5V no longer at terminal, only internal supply
More terminals for A and B.
Smaller Cap for +5V
* removed F1 (as +5V is no loger at a terminal)
* inserted D16
* changed J8, pin 5 from +5V to GND
* changed J1, pin 4 from GND to A and pin 5 from GND to B
* inserted JP1 to JP3
* changed C25 from 1000µ-throuhole to 100µ-SMD
* changed R3 and R5 form 1k to 620 Ohm (worst case for 16 nodes (Rin=12k) and 120 Ohm at beginning and end)
2023-10-21 foenich
Released Version 1.0.1
Changed default placement for capacitors at IN_2 and IN_3
* set C29 and C30 to mount
2023-10-21 foenich
Released Version 1.0.0
Correct geometry for impedance controlled traces for USB
* changed USB-wire witdh and reduced distance to GND
* changed versioning to x.y.z (major.functional change.bugfix)
2023-03-07 foenich
Correct voltage for addresses 0 to 7
* changed R17 to 5k
2023-02-25 foenich
Released initial Version 0.10