Notifications
You must be signed in to change notification settings - Fork 9
/
calibration.tex
879 lines (784 loc) · 46.4 KB
/
calibration.tex
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
%auto-ignore
\section{\label{sec:dom_calibration}Calibration and Stability}
Regular calibration of each individual DOM allows translation of the
recorded signals into a measurement of incident Cherenkov light at a
particular time, the basis of particle event reconstructions. The
primary DOM calibration routine is DOMCal (section~\ref{sec:domcal}), a
calibration procedure run yearly on in-ice DOMs and monthly on IceTop
DOMs that provides the constants used to convert DOM waveforms into
physical units (section~\ref{sec:waveformcal}). Global time calibration across the array of DOMs is
provided by the RAPCal procedure (section~\ref{sect:dom:rapcal}) that runs during
data-taking. The relative and absolute optical efficiency of the DOMs is
determined both by laboratory and \emph{in situ} measurements
(section~\ref{sec:domeff}). The stability of these calibrations is also
relevant, as not every calibration parameter can be tracked continuously during
data-taking (sections~\ref{sec:baselines} to \ref{sec:optical_stability}).
Understanding the statistical properties and time-dependence of the background ``dark
noise'' is also important for low-energy neutrino analyses, supernova
searches, and detector simulation (section~\ref{sect:darknoise}).
The determination of the optical properties of the ice is crucial to
the understanding of IceCube data but is beyond the scope of this work.
Further details can be found in refs.~\cite{Aartsen:2013rt,IC3:spice_lea}.
\subsection{\label{sec:domcal}DOMCal}
The calibration of the PMT waveforms recorded by the DOMs, i.e. translation
of digitized samples into voltage and time, as well as accounting for the
gain of the PMT itself, is achieved via DOM-by-DOM calibration constants
determined by the DOMs themselves. The primary reference inputs to
the DOM calibration software (DOMCal) are a precision electronic
pulser circuit providing known charges; a circuit providing a reference DC
bias voltage level; the 20 MHz oscillator on the Main
Board, used as the timing reference; and single photoelectrons, either from
background ``dark noise'' photons or a low-luminosity LED on the Main
Board. The Main Board oscillator is manufactured by Vectron
International (model C2560A-0009 TCXO) and has a certified stability
of roughly $1 \times 10^{-11}$ for a sample interval of 5 seconds~\cite{ICECUBE:DAQ}.
The Main Board LED is used to illuminate the PMT on the same DOM, as opposed
to the LED flashers described in
section~\ref{sec:flasher} which stimulate other DOMs. This LED produces
zero to a few tens of photoelectrons at the PMT~\cite{ICECUBE:DAQ}. Analysis and fitting of the
calibration results is done by the DOMCal software, with the results being
transmitted from each DOM to the surface as an XML file of fit parameters.
Because the operating conditions for
the in-ice DOMs are so stable, DOMCal is only run once a year on the full
detector. IceTop DOMs are calibrated once per month in order to track
temperature-dependent changes. Calibration is
typically performed on half the detector at a time, the other half
remaining in data-taking mode in case of a transient event (such as a
supernova) during calibration. The total calibration run length is a
little under three hours. Because the calibration procedure produces
light, these runs are excluded from normal analyses.
First, the discriminator circuits used to launch the DOM are calibrated
using the electronic pulser circuit, which is capacitively coupled into the
analog front-end before the Delay Board~\cite{ICECUBE:DAQ}. This
calibration is later refined using actual
PMT waveforms, once the PMT gain is known. Next, the ATWD voltage levels
are calibrated by sweeping the input DC bias voltage and recording the
corresponding waveforms at each DC level. Because of the slight variations in the ATWD circuits, this
calibration provides an individual linear relationship between ATWD counts
and voltage for each time sample and gain channel.
The average ATWD offset at zero input voltage, or baseline, is needed for
charge integration and can in principle be determined using the previous
ATWD calibration. However, in
practice, these baselines are extremely sensitive to the operating
condition of the DOMs, and since data-taking conditions cannot be exactly
replicated while running DOMCal, the baselines used during data-taking are
determined instead by using averaged forced triggers taken during a normal
run (section~\ref{sec:baselines}). DOMCal can still use baselines that it measures
for numerical charge integration during the calibration procedure.
The highest-gain channels of each ATWD are calibrated using the electronic
pulser circuit, and then the gains of the other ATWD channels and the fADC
are determined by varying the pulser output and comparing the charges
simultaneously recorded in multiple gain channels. This relative
calibration is later refined using PMT waveforms stimulated by the Main
Board LED.
The tunable ATWD sampling speed is calibrated by digitizing the Main Board oscillator
waveform and recording the number of clock cycles as a function of ATWD
speed setting; the relationship between configuration setting and sampling
speed is fit with a quadratic polynomial. The fADC sampling speed is
slaved to the 20 MHz oscillator, which is used as a timing reference, and
so is not separately calibrated. The relative timing of
the ATWD and fADC waveforms is determined using the electronic pulser circuit;
non-linear fitting of the digitized waveforms to known pulse templates is
required in order to determine the fADC time offset to the required accuracy.
The transit time of the PMT and Delay Board as a function of PMT high
voltage is determined by calculating the delay between the digitized
current pulse through the Main Board LED and the observed light pulse in
the ATWDs.
The PMT gain as a function of high voltage is calibrated using background
``dark noise'' photons --- the charge $e$ prior to amplification is quantized
and known. At each voltage level, a histogram of many observed charges is
recorded, where the charge is determined by numerical integration of the waveform.
Each histogram is fit with the sum of an exponential and a Gaussian
function (figure~\ref{fig:domcal_hvfit}). The peak of the Gaussian component is used
to
determine the amplification of the PMT at each voltage, and a linear fit
of $\log_{10}(\mathrm{gain})$ versus $\log_{10}(\mathrm{voltage})$ allows
the high voltage of each PMT to be tuned to the desired operating point ($10^7$
for in-ice DOMs; figure~\ref{fig:domcal_hv_settings}). Small
corrections ($3-5\%$) to the gain of each DOM are determined using charge
distributions recorded by the Processing and Filtering system
(section~\ref{sect:online:filter}) during normal data-taking. These
corrections are used to eliminate a systematic difference in the charge as
determined by DOMCal's numerical integration and the waveform pulse
unfolding used in data processing.
\begin{figure}[!h]
\centering
\includegraphics[width=0.6\textwidth]{graphics/dom/domcal/hvfit.pdf}
\caption{Sample SPE charge spectrum at a gain of $10^{7.5}$ as recorded by DOMCal and fit
\textit{in situ} with the sum of an exponential and a Gaussian function.}
\label{fig:domcal_hvfit}
\end{figure}
\begin{figure}[!h]
\centering
\includegraphics[width=0.6\textwidth]{graphics/dom/domcal/inice_hv_2016.pdf}
\caption{Distribution of PMT high voltages at $10^7$ gain for in-ice DOMs.}
\label{fig:domcal_hv_settings}
\end{figure}
\subsection{\label{sec:waveformcal}Waveform Calibration}
The deposited charge is the basis for all energy measurements in IceCube. The
calibration constants needed are 1) the pedestal, the value the digitizer
reads when the input voltage is zero, and 2) the gain, the input voltage change
required to increase the readout value by one count. An ATWD waveform
consists of readouts from 128 effectively independent
digitizers, while an fADC waveform consists of successive outputs of a
pipelined digitizer (256 samples). Two calibration constants per digitizer are needed to turn each of these
raw readout values (an integral number of ADC counts) into a
voltage, from which the deposited charge is calculated.
The baseline is the mean of the pedestals of each sample in a waveform, while the pedestal pattern is
the deviation of each sample's pedestal from the common baseline. The fADC
has no additional pedestal pattern, but for the ATWD, it is important to distinguish
between the pedestals of individual samples
and the common baseline of the entire waveform. In order to remove the
sample-dependent offset, the DOM subtracts the pedestal pattern from
the ATWD waveform before sending it to the surface. Thereafter, both ATWD
and fADC waveforms can be calibrated by first subtracting the common
baseline from each sample, then multiplying by the gain. Correct charge
measurement and energy reconstruction depends on correct measurement
of the baseline, as discussed in section~\ref{sec:baselines}.
The pedestal pattern is computed by the DAQ software at the beginning of each
run by averaging 200 forced-readout waveforms. Accidental single photoelectrons in
the individual waveforms are averaged out, but a single coincident bright event can
result in an offset in the pedestal average. In order to avoid such
light contamination, a second average is computed, and the
autocorrelation coefficient of the difference between the two pedestal
averages is computed at two different lags. This autocorrelation test detects averages in which a
single waveform contains at least a 15 PE pulse (approximately 0.1 PE in the
average). If light contamination is detected, the procedure is repeated.
The shift between the baseline of the pairs is also calculated to verify
that the baseline is stable. This procedure ensures that fewer than 1 DOM
in 1000 runs will contain a contaminated baseline.
The baseline is set to about 10\% of the maximum value of the
digitizer counts in
order to capture signals that go below the baseline. Since 2012, the
baseline value for each DOM is configured (section~\ref{sect:online:daqdomconfig}) in order to ensure
stability. The baseline value differs for each digitizer channel in
each DOM, ranging from 112 to 161 counts in the fADC and 109 to 172
counts in the ATWD. The baselines for each digitizer channel in each DOM are measured with
beacon hits, forced triggers that are collected during normal data
acquisition at a rate of 1.2~Hz per DOM
in in-ice DOMs and 4.8~Hz in IceTop DOMs. Beacon waveforms
from the fADC and ATWD of a typical DOM are shown in figure~\ref{fig:raw_baselines}.
\begin{figure}[!h]
\captionsetup[subfigure]{labelformat=empty}
\centering
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/fadc_average_beacon_raw.pdf}}
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/atwd_average_beacon_raw.pdf}}
\caption{Averaged beacon waveforms from the fADC (left) and ATWD (right) of
an IceCube DOM. The waveforms are an average of approximately $1000$ beacon
launches. The baseline, which is the mean value of the
beacon waveform, is shown as a horizontal red line. Typical raw SPE
waveforms are inset.}
\label{fig:raw_baselines}
\end{figure}
The digitizer gain is measured by DOMCal (section~\ref{sec:domcal}), a single
value for the fADC waveform and a sample-dependent value for the ATWD
waveform. The calibrated waveform voltage is then
\begin{equation}
\mathrm{voltage} = \mathrm{(counts - baseline) \times gain}
\end{equation}
The waveform start time is then corrected for the transit time,
the average time it takes a pulse to propagate through the entire
PMT and Delay Board. The transit time correction $t_{\mathrm{transit}}$ is
dependent on the PMT high voltage $V$:
\begin{equation}
t_{\mathrm{transit}} = \frac{m}{\sqrt{V}} + b
\end{equation}
\noindent where $m$ and $b$ are determined by DOMCal. The typical value of $m$
is 2000~ns$\cdot \sqrt{\mathrm{V}}$, and the typical value of $b$ is
80~ns, which includes the 75~ns delay line of the Main Board. The
typical transit time is therefore 130~ns. Waveform start times from the
second ATWD chip and the fADC are further
corrected for the delay $\Delta t$ with respect to the first ATWD
chip as determined by DOMCal, so the total start time correction is
$t_{\mathrm{transit}} + \Delta t$.
Finally, the waveforms are corrected for the effects of droop from the
transformer that couples the Main Board to the PMT output. The toroid
coupling effectively acts as a high-pass filter on the PMT output
that makes the tails of the waveforms ``droop'' and even
undershoot the baseline. This effect is temperature-dependent and is larger
at lower temperatures. The droop correction inverts the effect of the high-pass
filter and eliminates the undershoot in the waveform tails. This is
done by calculating the expected reaction voltage from the toroid at
each sample time, and adding the reaction voltage to the calibrated waveform
to compensate. The reaction voltage decays
according to a temperature-dependent model of the transformer behavior.
When a readout contains consecutive launches from the same
DOM, the reaction voltage at the end of the last launch is used to
correct for the residual droop in the following launch. DOMs
use two types of toroid transformers: the ``old toroid'' with a short
time constant that was used in early DOM production, and a ``new
toroid'' with a longer time constant that produces less
distortion. Of 5484~DOMs deployed in IceCube, 1204 are the old
toroid type, and 4280 are the new toroid type. The full correction is
modeled with two time constants,
where the DOM's transient response $\tilde{\delta}(t)$ to an input
signal $\delta(t)$ is given by
\begin{equation}
\tilde{\delta}(t) = \delta (t) - N((1 - f) e^{-t/\tau_1} +f\ e^{-t/\tau_2})
\label{eq:droop}
\end{equation}
\noindent where the first time constant $\tau_1$ is given by
\begin{equation}
\tau_1(T) = A + \frac{B}{1 + e^{(-T/C)}}\ .
\label{eq:tau1}
\end{equation}
\noindent In eqs.~\ref{eq:droop} and \ref{eq:tau1}, $T$ is the
temperature, and the constants $A$, $B$, $C$, $N$ and $f$ were
determined empirically with a dedicated analysis. For the old toroids, the
second time constant $\tau_2 =0.75\tau_1$. For the new toroids, $\tau_2$ is 500~ns.
\subsection{\label{sect:dom:rapcal}RAPCal}
The Reciprocal Active Pulsing Calibration (RAPCal) is a
continuously-running procedure for translating hit timestamps based on the
individual free-running DOM clocks to the synchronized surface clocks in the
ICL, in order to establish a standard time base for the array to
$O(\mathrm{ns})$ accuracy. Subsequently, the ICL-based hit timestamps can
then be translated to UTC. The scheme used for the time transfer involves
transmission of a pulse to and from each DOM and is shown in
figure~\ref{fig:rapcal_symmetry}. The base implementation is described in
\cite{ICECUBE:DAQ}; we describe here the details of the
algorithm and validation of the DOM relative time calibration.
While data transmission is paused, a bipolar pulse is generated and sent to
each DOM over the power/communications wire pair. After
this pulse has been received, a bipolar pulse --- having the same shape
as the one generated on the surface --- is generated in the DOM and sent
back to the surface. The pulses are timestamped using the local
clock count at each transmission and reception point. The symmetry of the
pulses sent in each direction and symmetry of the down- and up- cable
transmission enables the time transfer from each free-running DOM clock to the
surface clock and hence to UTC, without prior knowledge of the cable length
or its dispersive properties.
\begin{figure}[!h]
\centering
\includegraphics[width=0.6\textwidth]{graphics/dom/rapcal/rapcal_symmetry.pdf}
\caption{Diagram of the RAPCal time calibration scheme (not to scale).
Each transmitted and received pair of signals is
timestamped $(T_{\mathrm{tx}},T_{\mathrm{rx}})$ in the local clock domain, and by the symmetry of the
situation the midpoints $T_C$ between transmitted and received timestamps are
synchronous.}
\label{fig:rapcal_symmetry}
\end{figure}
\begin{figure}[h]
\centering
\includegraphics[width=0.6\textwidth]{graphics/dom/rapcal/dom_wf_zero_crossing.pdf}
\caption{Digitized RAPCal pulse as received by a DOM, after cable dispersion. The
zero-crossing of the baseline-subtracted pulse is used as a fine-delay
correction $f$ to the received timestamp $T_{\mathrm{rx}}$.}
\label{fig:rapcal_zero_crossing}
\end{figure}
The received dispersed bipolar pulses are digitized by a 20 MHz communications ADC and
timestamped using the local clock count. The received pulse timestamp
corresponds to a fixed delay after the start of the final pulse recovery. A RAPCal pulse sequence to and
from each DOM therefore results in a series of four timestamps
$T_{\mathrm{tx}}^{\mathrm{DOR}}$, $T_{\mathrm{rx}}^{\mathrm{DOM}}$,
$T_{\mathrm{tx}}^{\mathrm{DOM}}$, and $T_{\mathrm{rx}}^{\mathrm{DOR}}$
(figure~\ref{fig:rapcal_symmetry}). These timestamps initially count periods
of the DOM's 40 MHz clock and of the 20 MHz clock of the surface
electronics (DOR, section~\ref{sect:online:master_clock}); they are
translated into common units for the calculations described below.
Next, in order to improve the precision beyond the sampling speed of the
communications ADC, a ``fine delay'' correction $f$ to $T_{\mathrm{rx}}^{\mathrm{DOM}}$ and
$T_{\mathrm{rx}}^{\mathrm{DOR}}$ is calculated by interpolating
to find the negative-going baseline crossing, with the baseline voltage
calculated using the initial samples of the waveform (figure~\ref{fig:rapcal_zero_crossing}):
\begin{equation}
\tilde{T}_{\mathrm{rx}} = T_{\mathrm{rx}} - f\ .
\end{equation}
\noindent The midpoints $T_C^{\mathrm{DOR,DOM}}$ as shown in
figure~\ref{fig:rapcal_symmetry} are then determined, where
\begin{equation}
T_C = \frac{T_{\mathrm{tx}} + \tilde{T}_{\mathrm{rx}}}{2}\ .
\end{equation}
\noindent $T_C^{\mathrm{DOM}}$ and $T_C^{\mathrm{DOR}}$ then identify a
single point in time across the two clock domains.
The next stage of the process is to translate an arbitrary DOM hit timestamp
$t$ to UTC. In typical operating conditions, the RAPCal procedure
is repeated once per second for each DOM. We use the two nearest RAPCal
results before and after $t$ to derive a linear relationship
\begin{equation}
\mathrm{UTC}(t) = (1+\epsilon)(t - T_C^{\mathrm{DOM}}) +
T_C^{\mathrm{DOR}} + \Delta\ .
\end{equation}
\noindent The slope $(1+\epsilon)$ accounts for drifts in the DOM
clocks and is calculated from the $T_C$ pairs of the two neighboring RAPCal
results:
\begin{equation}
1+\epsilon = \frac{T_{C,2}^{\mathrm{DOR}} -
T_{C,1}^{\mathrm{DOR}}}{T_{C,2}^{\mathrm{DOM}} -
T_{C,1}^{\mathrm{DOM}}}\ .
\end{equation}
\noindent The median magnitude of $\epsilon$ is $1.34 \times 10^{-6}$.
Finally, because the timestamps $T^{\mathrm{DOR}}$ count the sub-second
time offset into the current UTC second, the UTC time offset $\Delta$ of the previous
1-second boundary, provided by the master clock, is added. Details on the
master clock system are provided in section~\ref{sect:online:master_clock}.
The stability and repeatability of the calibration is monitored by
tracking the cable delay from RAPCal, determined by
\begin{equation}
T_{\mathrm{cable}} = \frac{1}{2} \left( ( \tilde{T}_{\mathrm{rx}}^{\mathrm{DOR}} -
T_{\mathrm{tx}}^{\mathrm{DOR}} ) - (1+\epsilon)(T_{\mathrm{tx}}^{\mathrm{DOM}} -
\tilde{T}_{\mathrm{rx}}^{\mathrm{DOM}} )\right) \ .
\end{equation}
\noindent A representative distribution of $T_{\mathrm{cable}}$ from one DOM over an 8-hour
data-taking run is shown in figure~\ref{fig:rapcal_cable_len}, with a
standard deviation of 0.6 ns. Individual RAPCal measurements in which $T_{\mathrm{cable}}$
deviates by more than 10 ns from a moving average are discarded.
\begin{figure}[!h]
\centering
\includegraphics[width=0.6\textwidth]{graphics/dom/rapcal/tcal_hist_22-60.pdf}
\caption{Distribution of one-way cable delays from multiple RAPCal
measurements on DOM 22-60 (bottom of String 22), shown with a Gaussian fit.}
\label{fig:rapcal_cable_len}
\end{figure}
The time calibration through the entire data acquisition and software
processing chain is verified using the LED flashers. During
commissioning, performed on each string after deployment, all 12~LEDs on
each DOM are flashed simultaneously at
maximum brightness, and the arrival times of the first photons at the DOM above the flashing DOM
are recorded. Given the vertical spacing of 17~m on a standard IceCube
string and the group index of
refraction of 1.356 in ice at 400~nm \cite{price_woschnagg_ice}, the expected light travel time
from the flashing DOM to the DOM above is 77~ns. In DeepCore, the DOM
vertical spacings are 10~m and 7~m, corresponding to light travel
times of 45~ns and 32~ns respectively. The mean light travel
time to the DOM above for all flashing DOMs in ice is shown in
figure~\ref{fig:flashertiming}. The mean arrival time agrees with the
expectation for the DeepCore DOMs. For the standard DOMs, the observed
light travel time is about 3~ns longer than the expected light travel
time, due to the effects of scattering in the ice over the longer
distance. The accuracy of the photon arrival time with respect to the
arrival time of any other photon is measured using
the difference between arrival times at the two DOMs above the
flasher, which eliminates any uncertainty in the flasher source
time. Figure~\ref{fig:flashertiming} shows the distribution of the
difference in arrival times at the two DOMs above the flasher for the
DOMs with 7~m spacing, as the DOMs with larger spacing are more
affected by scattering in ice. The width of the distribution is
1.7~ns, so the measured timing accuracy is 1.7/$\sqrt{2}$~ns $=$ 1.2~ns. Muons are also used to
verify the time calibration~\cite{ICECUBE:DAQ}, including the absolute time difference
between the IceTop surface stations and the in-ice DOMs~\cite{IC3:perf}.
\begin{figure}[!h]
\captionsetup[subfigure]{labelformat=empty}
\centering
\subfloat[]{\includegraphics[width=0.495\textwidth]{graphics/dom/rapcal/flashmean.pdf}}
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/rapcal/oneabove.pdf}}
\caption{Left: Time from flasher emission to detection at the DOM above for 17~m vertical spacing
(red), 10~m vertical spacing (blue) and 7~m vertical spacing
(green). The expected light travel times in ice for each distance are marked with
vertical lines. Right: arrival time difference (blue) between the two
DOMs above the flasher for DOMs with 7~m vertical spacing. The
vertical red line denotes expected light
travel time in ice, and the mean of a Gaussian fit to the distribution
(dashed blue line) is 33~ns, due to
the effects of scattering in ice. The width of the distribution is 1.7~ns.}
\label{fig:flashertiming}
\end{figure}
\subsection{\label{sec:domeff}DOM Optical Efficiency}
A baseline value for the photon detection efficiency has been established
by combining PMT measurements at 337~nm and a separate model of wavelength-
and angle-dependent effects. Absolute sensitivity measurements were
performed on 13 IceCube PMTs, using single photons from a primary 337~nm laser beam of calibrated
intensity~\cite{ICECUBE:PMT}. The results agree well with independent
Hamamatsu measurements of sensitivity in the range 270--730~nm, which
were then normalized to the 337~nm measurement. The resulting quantum
efficiency at the center of the PMT at 390~nm is 25\%. A full
simulation model of the DOM includes the wavelength dependence of the PMT
response, optical absorption in the DOM glass and gel, discriminator
threshold effects, and photocathode non-uniformity. The angular dependence is
dominated by the shape of the photocathode and its response variation away
from the center, which was measured for 135 bare
PMTs~\cite{ICECUBE:PMT}. The efficiency was also measured for 16 fully integrated
DOMs, including glass and gel; the response of an example DOM is shown
in figure~\ref{fig:goldendom}. The efficiency measurement used the
337~nm nitrogen laser, as well as LEDs at 365~nm, 470~nm, 520~nm, and
572~nm due to the low transparency of the glass at short wavelengths.
\begin{figure}[!h]
\centering
\includegraphics[width=0.55\textwidth]{graphics/dom/performance/GDOM-NemuriNeko-2D-colz.pdf}
\caption{Position dependence of the response of a DOM, normalized to
the absolute efficiency at 365~nm. The x-y coordinates measure
distance from the center of the DOM.}
\label{fig:goldendom}
\end{figure}
The efficiency model as determined from the laboratory measurements was supplemented with \textit{in
situ} measurements using Cherenkov light from muons in the ice. The
efficiency measured \textit{in situ} includes effects of the cable
shadowing the DOM and the refrozen ``hole ice'' in the vicinity of the
DOM. In one
study, low-energy muons (median energy 82~GeV) with well-understood light
emission were selected to illuminate the downward-facing PMTs in the ice as
directly as possible. The number of photons detected at different
distances from these muons was then compared to predictions of the
simulation model~\cite{IC3:ereco}. Based on this and other \textit{in
situ} analyses, the central value for the efficiency was adjusted upward
by 10\% in the simulation, compared to the baseline. For physics analyses,
the normalization of the absolute DOM efficiency is generally included as a
nuisance parameter with prior uncertainty of 10\% that includes other uncertainties related to
generation and propagation of the light. Additional laboratory measurements
on assembled DOMs are in progress, including wavelength- and angle-dependent
effects, and are expected to reduce uncertainties~\cite{ICECUBE:DOMEFF}.
The absolute calibration at 337~nm was performed at room temperature on a
small subset of IceCube PMTs. The relative efficiency of all assembled DOMs
was separately measured as part of production testing
(section~\ref{sec:dom_prodtest}), using a 405~nm pulsed laser and a system of
fibers and diffusers to illuminate DOMs within 50$^{\circ}$ of the
PMT axis. Using this system, the relative efficiency of DeepCore DOMs
(high quantum efficiency type) was measured to be higher by a factor
of 1.39
compared to standard IceCube DOMs, agreeing well with the
manufacturer-specified value of 1.40. Further \textit{in situ} studies
using muons yielded a factor of 1.35~\cite{ICECUBE:DC}, an
effective value including the Cherenkov spectrum folded with the different
wavelength sensitivity curves of the two types of PMTs. The production
testing system also established that the efficiency change from room
temperature to $-40\ ^{\circ}\mathrm{C}$ is less than 1\% when gain is maintained at
the design value of $10^7$.
\subsection{\label{sec:baselines}Baseline Voltage Stability}
The beacon hits from which the digitizer baselines are derived
(section~\ref{sec:waveformcal}) are
monitored continuously throughout the year. The average values of the
beacon baselines are very stable, with shifts of no more than
0.2~counts per year, corresponding to 0.018~mV in the fADC and
0.025~mV in the high-gain ATWD channel. The baseline shifts from May
2015 to April 2016 are shown in figure~\ref{fig:baseline_stability_2015}.
\begin{figure}[!h]
\centering
\includegraphics[width=0.6\textwidth]{graphics/dom/reliability/baseline_stability_2015.pdf}
\caption{Distribution of shifts in baseline values in all ATWD
channels and the fADC for all DOMs from May 2015 to April
2016. The DOM configuration was unchanged during this period.}
\label{fig:baseline_stability_2015}
\end{figure}
Every year when the detector
is recalibrated, adjustments in the SPE discriminator threshold can
cause shifts of up to 0.6~counts (0.54~mV) in the fADC
baselines, for reasons not completely understood. ATWD baselines are
unaffected by the SPE discriminator
setting. Correcting recorded waveforms for the effect of transformer
coupling as described in section~\ref{sec:waveformcal} has
the side effect that small DC offset errors are converted into an
apparent PMT current that increases linearly in time over the course
of a few microseconds. The effect is stronger for DOMs with old-type toroid
transformers, where a baseline error of 0.6~counts can
turn an actual deposited charge of 1~PE into a measured charge of over
2~PE with an unphysical time structure. The observed distortion in a
simulated single photoelectron charge due to fADC baseline shifts is
shown in figure~\ref{fig:charge_fadcshift}. To avoid this problem, whenever the
discriminator thresholds are changed, the fADC baselines are re-measured,
and the values used for calibration are updated. As long as
the discriminator thresholds are unchanged, the baselines are stable
to within 0.2~counts
as shown above, and no charge distortion is seen at that level of
baseline stability.
\begin{figure}[!h]
\centering
\includegraphics[width=0.8\textwidth]{graphics/dom/reliability/charge_fadcshift.pdf}
\caption{Reconstructed charge from a simulated single photoelectron
deposit as a function of fADC baseline shift, for both old- and
new-toroid DOMs. The shaded region indicates the observed range of
baseline variation from the nominal value in ice; no observable
distortion in the charge spectrum is seen at these values.}
\label{fig:charge_fadcshift}
\end{figure}
The baselines can be sensitive to radio-frequency interference (RFI). In
2009, RF signals from the COBRA meteor radar transmitter broadcasting at
46.3~MHz \cite{meteor_radar}
appeared as sinusoidal or spiky modulations in the waveform
baselines. To mitigate this effect, one DOM was operated without PMT high
voltage and used to monitor the RF broadcasts and tag periods of RFI in
order to avoid data contamination. Also
in 2009, RFI from DOM 68-42 affected nearby DOMs after it failed during DOM
calibration and appeared to begin sparking, resulting in sinusoidal distortions
in the baselines of neighboring DOMs. The meteor radar
transmitter is no longer operating, and investigations into RFI
from more recent radar activities at South Pole (SuperDARN
\cite{superdarn}) have not revealed any measurable interference, either in DOM
baselines or in RAPCal time stability.
\subsection{\label{sec:gain_stability}Gain Stability}
The gain stability of the DOM, or the stability of the amplified charge
from converted photons, depends on a number of factors including stability
of the PMT high voltage, Main Board channel amplifiers, and the digitizers.
We can examine these subsystems using both historical calibration results
and by tracking the SPE charge during data-taking.
Variations of the front-end electronic amplifiers or the digitizers
themselves can potentially lead to changes in the overall gain of the DOM electronics.
The stability is demonstrated by comparing the Main Board channel amplifier gains
from sets of calibrations taken from 2011 to 2016
(figure~\ref{fig:domcal_ch_gain}). From year to year, the amplifier gain
calibration is repeatable to 0.1\%, 0.2\%, and 0.5\% in the high-gain,
medium-gain, and low-gain channels respectively. Since detector completion
in 2011, a small systematic shift of $-0.3\%$ is visible in the low-gain
channel, but this is corrected by updating the calibration constants of
each DOM.
\begin{figure}[!h]
\captionsetup[subfigure]{labelformat=empty}
\centering
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/channel_gain_shift_2016_2015.pdf}}
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/channel_gain_shift_2016_2011.pdf}}
\caption{Fractional ATWD channel amplifier gain shifts, from 2015 to
2016 (left) and 2011 to 2016 (right). Channels 0, 1, and 2 are
high gain, medium gain, and low gain respectively.}
\label{fig:domcal_ch_gain}
\end{figure}
The stability of the total gain, including both the PMT and
front-end electronics, is monitored during data-taking using the
single photoelectron peak of the charge distribution on each DOM from
cosmic ray muons. A
Gaussian + exponential function is fit to the peak region as in
figure~\ref{fig:spe_fit_thresh}, and the mean of the Gaussian is
tracked throughout the year. The threshold, defined as the bin in the histogram for which 99\% of the area of the histogram is contained in the sum of all higher bins, is also tracked through
the year. The peak position is calibrated to 1~PE
and is stable to within 0.01~PE for 95\% of all DOMs, as shown in
figure~\ref{fig:gain_spe_stability}. Over 99\% of DOMs show no
measurable change in the threshold as long as the discriminator
thresholds are unchanged; these settings are only changed once per year.
\begin{figure}[!h]
\centering
\includegraphics[width=0.6\textwidth]{graphics/dom/reliability/chargedist.pdf}
\caption{Charge distribution of a typical in-ice DOM. The threshold
is marked in red, and a Gaussian + exponential fit to
the SPE region is shown in blue. The mean of the Gaussian is used
to monitor the gain stability.}
\label{fig:spe_fit_thresh}
\end{figure}
\begin{figure}[!h]
\captionsetup[subfigure]{labelformat=empty}
\centering
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/mean_value_2015.pdf}}
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/meandiff_2015.pdf}}
\caption{Distribution of the mean of the Gaussian fit to the SPE
peak (left) and the shift in this value for each in-ice DOM (right) between May 2015 and April
2016.}
\label{fig:gain_spe_stability}
\end{figure}
There are about 12~DOMs that show unpredictable, abrupt shifts in the SPE peak
position of 0.05~PE or more. Figure~\ref{fig:gainshift_spe} shows the time history of the
SPE peak position of one of these DOMs over 4~months. The peak shift
corresponds to increases or decreases in the multi-photoelectron (MPE)
scaler rate, where the scaler counts the discriminator crossings. This
indicates that the SPE peak shift is indeed caused by a change in the DOM
gain. However, the SPE scaler rate is stable to within 2\%, indicating that the
probability to detect single photons is effectively unchanged.
\begin{figure}[!h]
\centering
\includegraphics[width=0.8\textwidth]{graphics/dom/reliability/gainshift.pdf}
\caption{Mean of the Gaussian fit to the SPE peak (top) and the SPE
scaler rate (middle) and MPE
scaler rate (bottom) from July 2015 to November 2015 for a DOM
that shows unpredictable gain shift behavior. The DOM
configuration was unchanged during this period.}
\label{fig:gainshift_spe}
\end{figure}
Long-term stability of the PMTs can be tracked by examining any change in
the high voltage vs.~gain calibration over time. The fractional change in gain for
all in-ice DOMs over a five-year time period is shown in
figure~\ref{fig:pmt_gainshift}. For most DOMs, the PMT gain is stable to
within $\pm3\%$ over the time period shown, with a median gain shift of $0.3\%$, while approximately $1\%$
of DOMs have a gain shift of more than 10\%. Any shifts are tracked with
regular calibration using the methods previously described.
\begin{figure}[!h]
\centering
\includegraphics[width=0.7\textwidth]{graphics/dom/reliability/pmt_gainshift.pdf}
\caption{Distribution of the fractional changes in PMT gain from 2011 to 2016 for all in-ice
DOMs, at the 2011 operating high voltage for each DOM.}
\label{fig:pmt_gainshift}
\end{figure}
\subsection{\label{sec:optical_stability}Optical Efficiency Stability}
The detector response in IceCube is verified with low energy muons as
described in ref.~\cite{IC3:ereco}. The detector response is monitored in each run using the track
detection probability (TDP) calculated from bright muon tracks
with more than 30 hits in IceCube. The muon
tracks are reconstructed using the likelihood methods described in
ref.~\cite{Ahrens:2003fg}, but charge and time information from the DOM under
study are excluded from the reconstruction. The TDP is
defined for each DOM as the ratio of the number of detected tracks
within $\SI{100}{\meter}$ of the DOM to the total number of tracks within $\SI{100}{\meter}$ of
the DOM. This ratio depends both on the optical properties of the ice
near the DOM and the optical efficiency of the DOM. We do not attempt
to separate
these effects in the TDP, but rather use the TDP to monitor the
overall stability of the detector response. Figure~\ref{fig:tdp} shows the TDP on
String 80, which includes both standard and HQE DOMs; the TDP is
20--25\% higher for HQE DOMs than for neighboring standard
DOMs, whereas the quantum efficiency is 35\% higher. The TDP is stable to within 1\% since 2012, when the baselines
were stabilized by being set in the DAQ configuration. Figure~\ref{fig:tdp} shows
the difference in the TDP for all DOMs between a run in 2012 and a run
in 2015.
\begin{figure}[!h]
\captionsetup[subfigure]{labelformat=empty}
\centering
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/tdp_onestring.pdf}}
\subfloat[]{\includegraphics[width=0.5\textwidth]{graphics/dom/reliability/tdpcomparison.pdf}}
\vspace{-1\baselineskip}
\caption{Left: track detection probability (TDP) in String 80, with a
mixture of standard DOMs (blue crosses) and HQE DOMs (red
circles). The variation with depth is due to the depth-dependent
optical properties of the ice. Right: shift in TDP for all in-ice DOMs between 2012 and 2015; standard DOMs are in blue, and
HQE DOMs are in red. The mean of the Gaussian fit to
the TDP shift in the standard DOMs is $-0.1$\%, and the mean
TDP shift in the HQE DOMs is 0.05\%.}
\label{fig:tdp}
\end{figure}
The detector response stability is also measured with the {\it in
situ} light sources in IceCube. Both the in-ice calibration laser
\cite{IC3:SC} and the flasher LEDs show less than 1\% difference in the total
charge collected between 2012 and 2015.
\subsection{\label{sect:darknoise}Dark Noise}
The vast majority of background hits result from dark noise, i.e. effects
that lead to the emission of an electron from the cathode of the PMT in the
absence of a photon source external to the DOM.
Dark noise is a complex phenomenon with numerous possible sources,
including thermionic emission, electronic noise, field emission
within the PMT, Cherenkov light from radioactive decays, and
scintillation / luminescence in the glass of the PMT and pressure sphere.
The average total in-ice hit rate is \SI{560}{\hertz} for DOMs with
standard PMTs and \SI{780}{\hertz} for high quantum efficiency DOMs. The
contribution from cosmic-ray muons, estimated as the in-ice HLC hit rate,
is small and decreases with depth from 25 Hz to 5 Hz.
The dark noise can be characterized as a combination of uncorrelated
(Poissonian) noise pulses with a rate between \SI{230}{\hertz} and
\SI{250}{\hertz}, and a correlated component, with a pulse rate from
\SI{280}{\hertz} to \SI{340}{\hertz}. A comparison at low temperature of
DOM dark noise to that of a bare PMT suggests that the majority of the
noise originates from the glass pressure sphere. Cherenkov light from
$^{40}\mathrm{K}$ decays contributes to the uncorrelated noise component,
and thus the potassium content of the glass was limited.
Measurements of early samples indicated a $\mathrm{K}_2\mathrm{O}$
concentration of 0.03\% by weight, roughly corresponding to 100 Bq of beta
decays per sphere.
The correlated noise manifests itself as an overabundance of short time
intervals between hits in a single DOM compared to the Poisson expectation
(figure~\ref{fig:darknoise_deltaT}).
The temperature dependence of the noise rate
(figure~\ref{fig:dom_darknoise_vs_temperature}) was determined by combining a
measured temperature profile of
the South Pole ice cap \cite{price2002temperature} with a fit of the
Poissonian expectation of the total dark noise rate to every individual
DOM, and was verified in lab measurements. The temperature of the in-ice
DOMs, measured on the Main Board, increases with depth from
$-31\ ^{\circ}\mathrm{C}$ to $-9\ ^{\circ}\mathrm{C}$
($10\ ^{\circ}\mathrm{C}$ above the ambient ice temperature).
\begin{figure}
\centering
\includegraphics[width=0.7\textwidth]{graphics/dom/performance/darknoise/DarkNoise_Layer2Doms.pdf}
\caption{Time interval between successive hits for all next-to-top layer
DOMs (DeepCore excluded). The line is an exponential fit to the
Poissonian regime between 7 and 15 ms.}
\label{fig:darknoise_deltaT}
\end{figure}
\begin{figure}
\centering
\includegraphics[width=0.7\textwidth]{graphics/dom/performance/darknoise/HitRatevsTemp_inice_nomuons_nofit_bigfont.pdf}
\caption{Dark noise rate of DOMs in ice as a function of temperature,
obtained from untriggered HitSpool data. Each data point represents the
average of 12 DOM layers from 78 strings (DeepCore excluded).}
\label{fig:dom_darknoise_vs_temperature}
\end{figure}
The short time intervals are clustered in bursts (uninterrupted sequences
of time intervals less than 3 ms) with an average number of
hits per burst increasing from \num{3.3} at \SI{-10}{\celsius} to \num{3.8} at
\SI{-30}{\celsius}. A study with forced-readout data shows that the
phenomenology of the correlated noise component in IceCube is in general in
good agreement with results reported in ref.~\cite{meyer_noise}, but an
unambiguous physical explanation is still to be confirmed. Stimulation of
glass samples with radioactive sources results in scintillation
\cite{helbing_glass}, suggesting that luminescence of the glass triggered
by the radioactive decay of $^{40}\mathrm{K}$ and other elements in the
pressure sphere is responsible. Naturally-occurring cerium in the glass is
a candidate for the active scintillator.
The various sources of dark noise present in a DOM can be separated using
the time between successive untriggered hits in HitSpool
data (section~\ref{sec:domhub_hitspool}), as shown in
figure~\ref{fig:darknoise_deltaT_components}. An overview of the various
noise components and their parameterizations is given in table \ref{tab:noise}. Late-time
correlated afterpulses, a common feature of PMTs, is attributed to
ionization of residual gases by electrons that were accelerated between
the dynodes. Although afterpulses occur at various time delays, this
component is parametrized here with a single average timescale. A
noise model incorporating these various sources is used for detector
simulation \cite{larson2013simulation}.
\begin{table}[h!]
\caption{Characteristics of noise components in IceCube DOMs, adapted from
ref.~\cite{stanisha_noise_14}.}
\centering
\footnotesize
\begin{tabularx}{\textwidth}{lXXr}
\toprule
Noise Component& Origin & Distribution & Parameters \\
\midrule
afterpulses & PMT & Gaussian & $\mu = \SI{6}{\micro\second}$, $\sigma = \SI{2}{\micro\second}$\\
uncorrelated & thermal noise, \newline radioactive decay & Poissonian & $\lambda \simeq \SI{250}{\hertz}$\\
correlated & luminescence (?) & log-normal &
$\mu = \num{-6}\ [\log_{10}(\delta t/\mathrm{sec})]$, \\
& & &
$\sigma = \num{0.85}\ [\log_{10}(\delta t/\mathrm{sec})]$ \\
\bottomrule
\end{tabularx}
\label{tab:noise}
\end{table}
\begin{figure}[!h]
\centering
\includegraphics[width=0.8\textwidth]{graphics/dom/performance/darknoise/SingleDOM_HitSpool_Hits_deltaT_fits_example.pdf}
\caption{Histogram of time differences between successive hits from HitSpool data of
DOM 15 on string 27 (blue) on a logarithmic scale in order to visualize the
different noise components \cite{heereman2015hitspooling}. A fourth
subdominant component centered at \SI{100}{\micro\second} is not parameterized and is still under study.}
\label{fig:darknoise_deltaT_components}
\end{figure}
The evolution of the dark noise contribution to the total rate over time was investigated using the
supernova scaler stream \cite{IC3:supernova, briedel_phd}, effectively
the summed dark noise rate of the detector with an artificial deadtime
applied to reduce the effect of correlated noise
(section~\ref{sect:SNDAQ}). A long-term exponential decay in
the noise rate is visible; this may be caused by
decreasing triboluminescence \cite{ice_tribo} arising from the initial ``freeze-in''
of newly deployed DOMs, impurities introduced during the drill
process, or a combination of the two effects. The decay
is especially recognizable in the standard deviation of the scaler
distribution (figure~\ref{fig:noise_over_time_briedel}), which decreases by
25\% over the course of the three years, with the decrease increasing with
depth~\cite{Piegsa09}. Changes in the mean rate are
initially dominated by the decay component and later by the seasonal
variation of atmospheric muons. The noise
rate decay is most pronounced when selecting strings
that were deployed in the final construction season, as shown in
figure~\ref{fig:noise_over_time_briedel_lastseasondepoyed}.
\begin{figure}[!h]
\centering
\includegraphics[width=1.0\textwidth]{graphics/dom/performance/darknoise/SN_Scalers_Whole_Detector_Mean_Variance_IC86_2011_2012_2013_smaller_height.pdf}
\caption{Mean and standard deviation of the supernova scaler distribution for the
entire detector over the course of the first three years of the
completed IceCube \cite{briedel_phd}. Spikes are due to calibration
runs which injected light into the detector, and to fluctuations in
individual DOMs.}
\label{fig:noise_over_time_briedel}
\end{figure}
\begin{figure}[!h]
\centering
\includegraphics[width=1.0\textwidth]{graphics/dom/performance/darknoise/SN_Scalers_IC86_mean_variance_Histo_IC86_2011_2012_2013_geomapping.pdf}
\caption{Mean and standard deviation of the supernova scaler rate of strings
deployed in the last deployment season (austral summer of 2010/2011)
\cite{briedel_phd}, where changes in the mean rate are
still dominated by the decay component. Spikes are due to calibration
runs which injected light into the detector, and to fluctuations in
individual DOMs.}
\label{fig:noise_over_time_briedel_lastseasondepoyed}
\end{figure}
Since the dark noise components are not correlated between
DOMs, the dark noise rate change is not prominent in local coincidence
hits, which are dominated by atmospheric muons (figure
\ref{fig:hlc_over_time_briedel}). Thus, the detector trigger rate as well
as many higher-level reconstruction variables are relatively isolated from the
noise rate variations. Nevertheless, the total hit rates for each DOM are
tracked over time and updated yearly in a database for simulation and
reconstruction purposes. Seasonal variations of these rates are
below the 1\% level.
\begin{figure}[!h]
\centering
\includegraphics[width=0.95\textwidth]{graphics/dom/performance/darknoise/HLC_Whole_Detector_Mean_Variance_IC86_2011_2012_2013.pdf}
\caption{Mean and standard deviation of the local coincidence hit rate distribution
\cite{briedel_phd}. Changes in dark noise rate do not
contribute significantly to changes in the local coincidence hit rate,
which is dominated by seasonal and weather-related
changes in the atmospheric muon flux.}
\label{fig:hlc_over_time_briedel}
\end{figure}