From a20b797027d94a5b6492b6dfce6ba7279dce67cb Mon Sep 17 00:00:00 2001 From: Yongzao <532741407@qq.com> Date: Thu, 7 Dec 2023 19:30:46 +0800 Subject: [PATCH] [IOTDB-6218] Rename storage_query_schema_consensus_free_memory_proportion to datanode_memory_proportion (#114) --- .../Deployment-and-Maintenance/Deployment-Recommendation.md | 4 ++-- src/UserGuide/Master/Reference/Common-Config-Manual.md | 6 +++--- .../Deployment-and-Maintenance/Deployment-Recommendation.md | 4 ++-- src/zh/UserGuide/Master/Reference/Common-Config-Manual.md | 6 +++--- 4 files changed, 10 insertions(+), 10 deletions(-) diff --git a/src/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md b/src/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md index 16be276a5..5fd59f93d 100644 --- a/src/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md +++ b/src/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md @@ -133,11 +133,11 @@ Temp storage size = WAL storage size + Consensus storage size + Compaction temp 1. WAL max wal storage size = memtable memory size ÷ wal_min_effective_info_ratio -- memtable memory size is decided by storage_query_schema_consensus_free_memory_proportion, storage_engine_memory_proportion and write_memory_proportion +- memtable memory size is decided by datanode_memory_proportion, storage_engine_memory_proportion and write_memory_proportion - wal_min_effective_info_ratio is decided by wal_min_effective_info_ratio configuration > Example: allocate 16G memory for DataNode, config is as below: -> storage_query_schema_consensus_free_memory_proportion=3:3:1:1:2 +> datanode_memory_proportion=3:3:1:1:1:1 > storage_engine_memory_proportion=8:2 > write_memory_proportion=19:1 > wal_min_effective_info_ratio=0.1 diff --git a/src/UserGuide/Master/Reference/Common-Config-Manual.md b/src/UserGuide/Master/Reference/Common-Config-Manual.md index 53b11f7a5..3cbee0177 100644 --- a/src/UserGuide/Master/Reference/Common-Config-Manual.md +++ b/src/UserGuide/Master/Reference/Common-Config-Manual.md @@ -236,11 +236,11 @@ Different configuration parameters take effect in the following three ways: * storage\_query_schema_consensus_free_memory_proportion -|Name| storage\_query\_schema\_consensus\_free\_memory\_proportion | +|Name| data\_node\_memory\_proportion | |:---:|:-------------------------------------------------------------------------------------------------------------| -|Description| Memory Allocation Ratio: StorageEngine, QueryEngine, SchemaEngine, Consensus and Free Memory | +|Description| Memory Allocation Ratio: StorageEngine, QueryEngine, SchemaEngine, StreamingEngine, Consensus and Free Memory | |Type| Ratio | -|Default| 3:3:1:1:2 | +|Default| 3:3:1:1:1:1 | |Effective| After restarting system | * schema\_memory\_allocate\_proportion diff --git a/src/zh/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md b/src/zh/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md index d998db038..74f39c9e9 100644 --- a/src/zh/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md +++ b/src/zh/UserGuide/Master/Deployment-and-Maintenance/Deployment-Recommendation.md @@ -133,11 +133,11 @@ IoTDB 存储空间=数据存储空间 + 元数据存储空间 + 临时存储空 1. 写前日志 最大写前日志空间占用 = memtable 总内存占用 ÷ 最小有效信息占比 -- memtable 总内存占用和 storage_query_schema_consensus_free_memory_proportion、storage_engine_memory_proportion、write_memory_proportion 三个参数有关 +- memtable 总内存占用和 datanode_memory_proportion、storage_engine_memory_proportion、write_memory_proportion 三个参数有关 - 最小有效信息占比由 wal_min_effective_info_ratio 决定 > 示例:为 IoTDB 分配 16G 内存,配置文件如下 -> storage_query_schema_consensus_free_memory_proportion=3:3:1:1:2 +> datanode_memory_proportion=3:3:1:1:1:1 > storage_engine_memory_proportion=8:2 > write_memory_proportion=19:1 > wal_min_effective_info_ratio=0.1 diff --git a/src/zh/UserGuide/Master/Reference/Common-Config-Manual.md b/src/zh/UserGuide/Master/Reference/Common-Config-Manual.md index 84bfdbc8b..ed1c697a3 100644 --- a/src/zh/UserGuide/Master/Reference/Common-Config-Manual.md +++ b/src/zh/UserGuide/Master/Reference/Common-Config-Manual.md @@ -238,11 +238,11 @@ IoTDB ConfigNode 和 DataNode 的公共配置参数位于 `conf` 目录下。 * storage\_query_schema_consensus_free_memory_proportion -|名字| storage\_query\_schema\_consensus\_free\_memory\_proportion | +|名字| data\_node\_memory\_proportion | |:---:|:----------------------------------------------------------------------| -|描述| 存储,查询,元数据,共识层,空闲内存比例 | +|描述| 存储,查询,元数据,流处理引擎,共识层,空闲内存比例 | |类型| Ratio | -|默认值| 3:3:1:1:2 | +|默认值| 3:3:1:1:1:1 | |改后生效方式| 重启服务生效 | * schema\_memory\_allocate\_proportion