pysma library

image Codecov

This is my personal fork of the SMA Webconnect library for Python 3. The library was originally created by Johann Kellerman to integrate SMA with HomeAssistant.

See http://www.sma-solar.com for more information on the SMA solar inverters

This fork aims to document my own invertor, the Sunny Boy 4.0 AV-41. It has webconnect 1.5 and uses a self signed-ssl certificate. It can send output to any MQTT broker.

Example usage

See example.py for a basic usage and tests

python3 example.py https://ipaddress user password

Home Assistant

The Home Assistant sma sensor documentation can be found here

By default ssl is disabled (Sunnyboy 1.5 WebConnect uses http://). If you access your SMA WebConnect via https:// you should set both ssl: true and verify_ssl: false.

Daily usage is not always available from the SMA WebConnect interface. It is possible to get around this by using a utility meter

Sunny Boy 4.0 AV-41 (probably all AV-41 models)

Listed below is a table representing all instantaneous values that are currently offered by the Sunny Boy 4.0 AV-41. This way, you can add your own sensors in the init.py file after you installed the pysma library.

Sensor Value Json
1.) Status
1.1) Operation
Waiting time until feed-in ------- 6100_00416600
Condition Ok 6180_08214800
Operating status Derating 6180_08412800
Grid relay status Closed 6180_08416400
Derating not active 6180_08416500
1.2) PV system control
Status On 6180_08413300
1.3) Device control
Status On 6180_08413200
1.4) Device status
Ok 4,000 W 6100_00411E00
Warning 0 W 6100_00411F00
Fault 0 W 6100_00412000
1.5) Inverter
Condition Ok 6180_08414C00
1.6) Current event
Event number manufacturer ------- 6100_00418000
Message none 6180_08414900
Recommended action none 6180_08414A00
Fault correction measure none 6180_08414B00
1.7) Update
Status ------- 6180_08412900
2.) Device
2.1) Operation
Backup mode status Grid mode 6180_08436800
3.) DC Side
3.1) DC measurements
Power [A] 0 W 6380_40251E00_0
Power [B] 0 W 6380_40251E00_1
Voltage [A] 275.14 V 6380_40451F00_0
Voltage [B] 275.36 V 6380_40451F00_1
Current [A] 0.000 A 6380_40452100_0
Current [B] 0.000 A 6380_40452100_1
4.) AC Side
4.1) Grid measurements
Power 14 W 6100_40263F00
Grid frequency 50.00 Hz 6100_00465700
Excitation type of cosPhi Overexcited 6180_08465A00
4.2) Phase currents
Phase L1 0.591 A 6100_40465300
Phase L2 ------- 6100_40465400
Phase L3 ------- 6100_40465500
4.3) Phase voltage
Phase L1 235.30 V 6100_00464800
Phase L2 ------- 6100_00464900
Phase L3 ------- 6100_00464A00
Phase L1 against L2 ------- 6100_00464B00
Phase L2 against L3 ------- 6100_00464C00
Phase L3 against L1 ------- 6100_00464D00
4.3) Power per phase
Phase L1 14 W 6100_40464000
Phase L2 ------- 6100_40464100
Phase L3 ------- 6100_40464200
4.4) PV generation
PV generation power 14 W 6100_0046C200
Meter count and PV gen. meter 92,783 Wh 6400_0046C300
4.5) Measured values
Total yield 92,783 Wh 6400_00260100
Operating time 66.69 h 6400_00462E00
Feed-in time 64.20 h 6400_00462F00
4.6) Grid measurements
Supplied power ------- 6100_40463600
Power absorbed ------- 6100_40463700
Displacement power factor ------- 6100_00464E00
Grid frequency ------- 6100_00468100
Apparent power ------- 6100_00468100
Reactive power ------- 6100_4046F100
Total yield 0 Wh 6400_00462400
Absorbed energy 0 Wh 6400_00462400
Total energy fed by device 0 Wh 6400_00462400
Total energy absorbed from the grid by the device 0 Wh 6400_00469200
4.7) Phase currents
Phase L1 ------- 6100_40466500
Phase L2 ------- 6100_40466500
Phase L3 ------- 6100_40466500
4.8) Phase voltage
Phase L3 against L1 ------- 6100_00467700
Phase L1 against L2 ------- 6100_00467800
Phase L2 against L3 ------- 6100_00467900
Phase L1 ------- 6100_0046E500
Phase L2 ------- 6100_0046E600
Phase L3 ------- 6100_0046E700
4.9) Apparent power
Phase L1 ------- 6100_40466C00
Phase L2 ------- 6100_40466D00
Phase L3 ------- 6100_40466E00
4.10) Reactive power
Phase L1 ------- 6100_4046EE00
Phase L2 ------- 6100_4046EF00
Phase L3 ------- 6100_4046F000
4.11) Power per phase
Phase L1 ------- 6100_0046E800
Phase L2 ------- 6100_0046E900
Phase L3 ------- 6100_0046EA00
4.12) Absorbed phase power
Phase L1 ------- 6100_0046EB00
Phase L2 ------- 6100_0046EC00
Phase L3 ------- 6100_0046ED00
4.13) Operation
Mains connection Public electricity mains 6180_0846A600
5.) Measured values
5.1) WLAN
Signal strength of the selected network 0 6100_004AB600