#!/bin/bash
# Temperature LUT Properties
TEMP_TRANSITION_START=32 # degC
TEMP_TRANSITION_END=40 # degC
PWM_MAX=100 # %
#### Config
./set 0x00 0x88 # CR1
./set 0x01 0x10 # CR2
./set 0x02 0xb0 # CR3
./set 0x03 0xff # FFDC (Default)
./set 0x04 0xef # MASK
./set 0x05 0x18 # IFR (Default)
./set 0x06 40 # RHSH degC
./set 0x07 00 # RHSL
./set 0x08 50 # LOTSH degC
./set 0x09 00 # LOTSL
./set 0x0a 40 # ROTSH degC
./set 0x0b 00 # ROTSL
./set 0x0c 50 # LHSH degC
./set 0x0d 00 # LHSL
./set 0x0e 0xff # TCTH (Default)
./set 0x0f 0xff # TCTL (Default)
# User EEPROM
./set 0x10 0xba # Signature
./set 0x11 0xa0 # Type: Auto (LUT) Control
./set 0x12 0x01 # Version
./set 0x13 0x00
./set 0x14 0x00
./set 0x15 0x00
./set 0x16 0x00
./set 0x17 0x00
### LUT
TEMP_BASE=17 # degC
TEMP_STEP=2 # degC
TEMP_MAX=111 # degC
LUT_ADDR=LUT_BASE # Global for address manipulated below
PWM_VAL=0x00 # Global for PWM register values manipulated below
function lut_address () {
local TEMP=$1
LUT_BASE=0x20
LUT_OFFSET=$(( ( TEMP - TEMP_BASE ) / TEMP_STEP ))
LUT_ADDR=$(( LUT_BASE + LUT_OFFSET ))
LUT_ADDR=`printf "0x%02x" $LUT_ADDR`
return
}
function pwm_value () {
local PWM=$1
PWMR=`bc <<< "scale=2; $PWM * 256 / 100"`
PWMR=`printf "%.0f" $PWMR` # Rounds here.
PWMR=`printf "0x%02x" $PWMR` # Hex here (for show).
if (( PWMR > 0xff )); then
PWMR=0xff
fi
PWM_VAL=$PWMR
return
}
# Fill LUT
PWM=$PWM_MAX
for TEMP in `seq $TEMP_BASE $TEMP_STEP $TEMP_MAX`; do
if (( TEMP < TEMP_TRANSITION_START )); then
# Fill for low temperatures
PWM=$PWM_MAX
elif (( TEMP < TEMP_TRANSITION_END )); then
# Fill for transition region
PWM=`bc <<< "scale=2; $PWM / 2"`
else # TEMP >= TEMP_TRANSITION_END
# Fill for high temperatures
PWM=0
fi
echo -e "LUT Fill: ${TEMP}degC\t${PWM}% Heat"
lut_address $TEMP # Sets $LUT_ADDR global
pwm_value $PWM # Sets $PWM_VAL global
./set $LUT_ADDR $PWM_VAL
done
### Operational
# Set Duty Cycle
./set 0x50 0x00 # PWMR