Skip to content
This repository has been archived by the owner on Oct 14, 2018. It is now read-only.

RAMPS-FD: Improve ground connections #23

Open
cefiar opened this issue Dec 22, 2013 · 1 comment
Open

RAMPS-FD: Improve ground connections #23

cefiar opened this issue Dec 22, 2013 · 1 comment

Comments

@cefiar
Copy link
Contributor

cefiar commented Dec 22, 2013

Specifically around:
Pins between +5V and VIN
Thermistors and End Stops.

@cefiar
Copy link
Contributor Author

cefiar commented Dec 22, 2013

Note: Can improve ground to thermistors by re-routing Endstop connections slightly (particularly net N-00000118), and removing the top side ground connection between E0-MOT Ground and Serial1 Ground (replace with connections on bottom). This allows a further (thicker) ground to be run between Serial0 Ground and the Thermistor Ground on the top layer.

bobc added a commit that referenced this issue Dec 23, 2013
Extensive copper thickening (Bug #23).