\mainpage Main Page
Hall Current 9 Click is a compact add-on board that contains the coreless current sensor corresponding to the safety standards. This board features the CQ3300, a high-speed response coreless current sensor using a Hall sensor that outputs the analog voltage proportional to the AC/DC from AKM Semiconductor.
- Author : Nenad Filipovic
- Date : Dec 2020.
- Type : I2C type
We provide a library for the HallCurrent9 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on mikroE github account.
> This library contains API for Hall Current 9 Click driver.
hallcurrent9_cfg_setup
Config Object Initialization function.
void hallcurrent9_cfg_setup ( hallcurrent9_cfg_t *cfg );
hallcurrent9_init
Initialization function.
HALLCURRENT9_RETVAL hallcurrent9_init ( hallcurrent9_t *ctx, hallcurrent9_cfg_t *cfg );
hallcurrent9_default_cfg
Click Default Configuration function.
void hallcurrent9_default_cfg ( hallcurrent9_t *ctx );
hallcurrent9_read_adc
Hall Current 9 I2C ADC reading function.
err_t hallcurrent9_read_adc ( hallcurrent9_t *ctx, uint16_t *read_adc );
hallcurrent9_set_calibration
Hall Current 9 set calibration function.
err_t hallcurrent9_set_calibration ( hallcurrent9_t *ctx, hallcurrent9_calibration_data_t *adc_val );
hallcurrent9_get_current
Hall Current 9 get current function.
float hallcurrent9_get_current ( hallcurrent9_t *ctx, hallcurrent9_calibration_data_t *adc_val );
This library contains API for Hall Current 9 Click driver. The library contains drivers for measuring ADC values and for calculation current.
The demo application is composed of two sections :
Initializes I2C driver and triggers the built-in calibration.
void application_init ( void ) {
log_cfg_t log_cfg; /**< Logger config object. */
hallcurrent9_cfg_t hallcurrent9_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_printf( &logger, "\r\n" );
log_printf( &logger, "--------------------------\r\n" );
log_printf( &logger, " Hall Current 9 click \r\n" );
log_printf( &logger, "--------------------------\r\n" );
log_info( &logger, " Application Init " );
// Click initialization.
hallcurrent9_cfg_setup( &hallcurrent9_cfg );
HALLCURRENT9_MAP_MIKROBUS( hallcurrent9_cfg, MIKROBUS_1 );
err_t init_flag = hallcurrent9_init( &hallcurrent9, &hallcurrent9_cfg );
if ( init_flag == I2C_MASTER_ERROR ) {
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
log_printf( &logger, "---------------------------\r\n" );
log_printf( &logger, " Calibration \r\n" );
log_printf( &logger, "- - - - - - - - - - - - - -\r\n" );
log_printf( &logger, "> Turn OFF the Power unit <\r\n" );
log_printf( &logger, "- - - - - - - - - - - - - -\r\n" );
log_printf( &logger, " In the following 5 sec. \r\n" );
log_printf( &logger, " turn OFF the Power Supply \r\n" );
Delay_ms( 5000 );
log_printf( &logger, "-------------------------\r\n" );
log_printf( &logger, " Start calibration \r\n" );
if ( hallcurrent9_set_calibration( &hallcurrent9, &avg_adc_data ) == HALLCURRENT9_OK ) {
log_printf( &logger, "---------------------------\r\n" );
log_printf( &logger, " Calibration Done \r\n" );
Delay_ms( 1000 );
}
log_printf( &logger, "---------------------------\r\n" );
log_printf( &logger, " Start measurements : \r\n" );
log_printf( &logger, "---------------------------\r\n" );
}
This is an example that demonstrates the use of the Hall Current 9 click board. In this example, we read and display the ADC and current ( mA ) data. Results are being sent to the Usart Terminal where you can track their changes.
void application_task ( void ) {
log_printf( &logger, "--------------------------\r\n", adc_data );
hallcurrent9_read_adc( &hallcurrent9, &adc_data );
log_printf( &logger, " ADC : %d \r\n", adc_data );
current = hallcurrent9_get_current( &hallcurrent9, &avg_adc_data );
log_printf( &logger, " Current : %.2f mA \r\n", current );
Delay_ms( 2000 );
}
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on mikroE github account.
Other mikroE Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.HallCurrent9
Additional notes and informations
Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all Mikroelektronika compilers.