Notifications
You must be signed in to change notification settings - Fork 0
/
kikusui_plz4w.py
169 lines (159 loc) · 11.7 KB
/
kikusui_plz4w.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
import time
# https://manual.kikusui.co.jp/P/PLZ4W/i_f_manual/english/00-intro.html
class kikusui_plz4w():
def __init__(self, pyvisa_instr):
self.plz4w = pyvisa_instr # this is the pyvisa instrument, rm.open_resource('USB0::0x0A7E::0x1205::VB011286::INSTR')
def get_all_scpi_list(self):
result_list = [ ]
for dict in [self.source_dict, self.inout_dict, self.meas_trig_dict ]:
for command in dict:
time.sleep(0.1)
# print(command.format("?"))
result = (self.plz4w.query(command.format("?"))).rstrip('\r\n')
result = " " + result
result_list.append(command.format(result))
# print(command.format(result))
return result_list
def get_unique_scpi_list(self):
unique_scpi_list = []
inst_settings_list = self.get_all_scpi_list()
for setting in inst_settings_list:
if (setting not in self.settings_por_scpi_list):
unique_scpi_list.append(setting)
return unique_scpi_list
source_dict = {"SOURce:CONDuctance{0}": "Set the conductance",
"SOURce:CONDuctance:RANGe{0}": "Set the range of conductance",
# "SOURce:CONDuctance:TRIGgered{0}": "Set the conductance when a trigger is activated",
"SOURce:CURRent{0}": "Set the current",
"SOURce:CURRent:PROTection{0}": "Set the overcurrent protection",
"SOURce:CURRent:PROTection:ACTion{0}": "Sets whether to turn off the load or limit the current when the OCP trips",
"SOURce:CURRent:RANGe{0}": "Set the range of current",
"SOURce:CURRent:SLEW{0}": "Set the slew rate",
# "SOURce:CURRent:TRIGgered{0}": "Set the current when a trigger is activated",
"SOURce:FUNCtion{0}": "Sets the operation mode",
"SOURce:FUNCtion:CTIMe{0}": "Turns ON/OFF the count time",
"SOURce:FUNCtion:RESPonse{0}": "Set the transient response speed",
# "SOURce:FUNCution:RESPonse:CR{0}": "Set the transient response speed for CR mode of PLZ-4WL",
# "SOURce:FUNCution:RESPonse:CV{0}": "Set the transient response speed for CV mode of PLZ-4WL",
"SOURce:FUNCtion:SSTart{0}": "Set the soft start time",
"SOURce:POWer{0}": "Set the power",
"SOURce:POWer:PROTection{0}": "Set the overpower protection",
"SOURce:POWer:PROTection:ACTion{0}": "Sets whether to turn off the load or limit the power when the OPP trips",
"SOURce:POWer:RANGe{0}": "Set the range of power",
# "SOURce:PRESet:RECall{0}": "Recalls settings from memory",
# "SOURce:PRESet:STORe{0}": "Stores the settings to memory",
"SOURce:PULSe{0}": "Turns ON/OFF the switching mode",
"SOURce:PULSe:DCYCle{0}": "Set the switching duty cycle",
"SOURce:PULSe:FREQuency{0}": "Set the pulse frequency",
"SOURce:PULSe:LEVel:CONDuctance{0}": "Set the conductance level",
"SOURce:PULSe:LEVel:CURRent{0}": "Set the current level",
"SOURce:PULSe:LEVel:PERCentage:CONDuctance{0}": "Set the conductance level in terms of a percentage of the setting",
"SOURce:PULSe:LEVel:PERCentage:CURRent{0}": "Set the current level in terms of a percentage of the setting",
"SOURce:PULSe:PERiod{0}": "Set the pulse period",
"SOURce:VOLTage{0}": "Set the voltage",
"SOURce:VOLTage:PROTection:STATe{0}": "Turns ON/OFF the undervoltage protection",
"SOURce:VOLTage:PROTection:UNDer{0}": "Set the undervoltage protection",
"SOURce:VOLTage:RANGe{0}": "Set the range of voltage" }
inout_dict = { "INPut{0}": "Turns ON/OFF the load",
"OUTPut{0}": "Turns ON/OFF the load",
# "INPut:PROTection:CLEar{0}" : "Clears the alarm",
# "OUTPut:PROTection:CLEar{0}" : "Clears the alarm",
"INPut:SHORt{0}": "Turns ON/OFF the short function",
"OUTPut:SHORt{0}": "Turns ON/OFF the short function",
"INPut:TIMer{0}": "Set the cutoff time",
"OUTPut:TIMer{0}": "Set the cutoff time",
# "INPut:TRIGgered{0}": "Turns ON/OFF the load when a trigger is activated",
# "OUTPut:TRIGgered{0}": "Turns ON/OFF the load when a trigger is activated"
}
meas_trig_dict = { "INIT:CONT{0}": "Sets whether to continue the trigger wait status",
# "MEASure:CURRent{0}" : "Reads the measured current",
# "MEASure:POWer{0}" : "Reads the measured power",
# "MEASure:VOLTage{0}" : "Reads the measured voltage",
# "MEASure:ETIMe{0}" : "Reads the elapsed time of measurement",
# "ABORt" : "Aborts the trigger function",
# "INIT" : "Initiates the trigger function",
}
system_dict = { "SYSTem:CAPability{0}" : "Query the SCPI instrument class and the basic functions",
"SYSTem:ERRor{0}" : "Reads the oldest error information",
"SYSTem:KLOCk" : "Locks the panel operation for PLZ-4WH",
"SYSTem:KLOCk:SELect{0}": "Set the type of panel lock operation for PLZ-4WH",
"SYSTem:LOCk{0}": "Set the PLZ-4W/PLZ-4WL/PLZ-4WH operation to panel operation",
"SYSTem:REMote{0}": "Set the PLZ-4W/PLZ-4WL/PLZ-4WH operation to remote mode",
"SYSTem:RENable{0}": "Set the PLZ-4W operation to remote mode",
"SYSTem:RSENsing{0}": "Set the remote sensing function for PLZ-4WL",
"SYSTem:RWLock{0}": "Set the PLZ-4W/PLZ-4WL/PLZ-4WH operation to remote mode",
"SYSTem:VERSion{0}" : "Query the version of the SCPI specifications" }
program_dict = { "PROGram:CLEar" : "Delete the contents of the sequence",
"PROGram:CHAin{0}": "Set the number of the program to be executed next",
"PROGram:CRANge{0}": "Set the current range",
"PROGram:EXECuting{0}": "Query the number of the program currently in operation",
"PROGram:FSPeed:EDIT{0}": "Edit an existing step (fast sequence)",
"PROGram:FSPeed:EDIT:LINear{0}": "Set the FILL function (fast sequence)",
"PROGram:FSPeed:EDIT:WAVE{0}": "Edit the waveform of the step (fast sequence)",
"PROGram:FSPeed:END{0}": "Set the end step (fast sequence)",
"PROGram:FSPeed:TIME{0}": "Set the step execution time (fast sequence)",
"PROGram:LINPut{0}": "Set the load on/off condition after the sequence ends",
"PROGram:LOOP{0}": "Set the number of program loops",
"PROGram:LOUT{0}": "Set the load on/off condition after the sequence ends",
"PROGram:LVALue{0}": "Set the setting value after the specified program ends",
"PROGram:MEMO{0}": "Set the memo",
"PROGram:MODE{0}": "Set the mode",
"PROGram:NAME{0}": "Specify the program number",
"PROGram:NSPeed:ADD{0}": "Add a step after the last step (normal sequence)",
"PROGram:NSPeed:COUNt{0}": "Query the number of steps (normal sequence)",
"PROGram:NSPeed:DELete{0}": "Delete the selected program sequence step (normal sequence)",
"PROGram:NSPeed:DELete:ALL": "Deletes the all the steps (normal sequence)",
"PROGram:NSPeed:EDIT{0}": "Edit an existing sequence step (normal sequence)",
"PROGram:NSPeed:INSert{0}": "Insert a normal sequence step (normal sequence)",
"PROGram:STATe{0}": "Execute the selected program",
"PROGram:VRANge{0}": "Set the voltage range" }
status_dict = { "STATus:CSUMmary{0}": "CSUMmary status register: Event",
"STATus:CSUMmary:CONDtion{0}": "CSUMmary status register: Condition of register",
"STATus:CSUMmary:ENABle{0}": "CSUMmary status register: Enable register",
"STATus:CSUMmary:PTRansition{0}": "CSUMmary status register: Positive transition",
"STATus:CSUMmary:NTRansition{0}": "CSUMmary status register: Negative transition",
"STATus:OPERation{0}": "OPERation status register: Event",
"STATus:OPERation:CONDtion{0}": "OPERation status register: Condition of register",
"STATus:OPERation:ENABle{0}": "OPERation status register: Enable register",
"STATus:OPERation:PTRansition{0}": "OPERation status register: Positive transition",
"STATus:OPERation:NTRansition{0}": "OPERation status register: Negative transition",
"STATus:QUEStionable{0}": "QUEStionable status register: Event",
"STATus:QUEStionable:CONDtion{0}": "QUEStionable status register: Condition of register",
"STATus:QUEStionable:ENABle{0}": "QUEStionable status register: Enable register",
"STATus:QUEStionable:PTRansition{0}": "QUEStionable status register: Positive transition",
"STATus:QUEStionable:NTRansition{0}": "QUEStionable status register: Negative transition",
"STATus:PRESet{0}": "Constructing status data"}
settings_por_scpi_list = [ "SOURce:CURRent:PROTection:ACTion LIM",
"SOURce:FUNCtion CC",
"SOURce:PULSe:DCYCle 50.0",
"SOURce:PULSe:LEVel:PERCentage:CURRent 100.0",
"SOURce:VOLTage:PROTection:STATe 0",
"SOURce:VOLTage:RANGe HIGH",
"SOURce:PULSe:LEVel:CONDuctance 0.000",
"SOURce:CURRent 0.000",
"SOURce:CURRent:RANGe HIGH",
"SOURce:VOLTage 0.00",
"SOURce:PULSe:PERiod 0.200000",
"SOURce:FUNCtion:RESPonse 1.0",
"SOURce:CURRent:PROTection 36.29",
"SOURce:PULSe:LEVel:CURRent 0.000",
"SOURce:FUNCtion:SSTart 0.001",
"SOURce:CURRent:SLEW 0.002500",
"SOURce:PULSe:LEVel:PERCentage:CONDuctance 50.0",
"SOURce:POWer:RANGe HIGH",
"SOURce:PULSe 0",
"SOURce:POWer:PROTection 181.5",
"SOURce:PULSe:FREQuency 5.0",
"SOURce:CONDuctance:RANGe HIGH",
"SOURce:CONDuctance 0.0000",
"SOURce:POWer 0.00",
"SOURce:FUNCtion:CTIMe 0",
"SOURce:POWer:PROTection:ACTion LIM",
"SOURce:VOLTage:PROTection:UNDer 0.00",
"INPut 0",
"INPut:SHORt 0",
"INPut:TIMer 0",
"OUTPut 0",
"OUTPut:TIMer 0",
"OUTPut:SHORt 0",
"INIT:CONT 0" ]