Solis Inverters with Home Assistant

Summary Table

Connection Type DLS-W DLS-L S3-WiFi-ST S2-WL-ST
WiFi Yes No Yes Yes
LAN No Yes No Yes
SolisCloud Yes Yes Yes Yes
SolisCloud Remote Control Yes* Yes* Yes Yes
Home Assistant via SolarMan v5 Yes No No No
Home Assistant via Core Modbus TCP No Yes (3389) No Yes (502)
Home Assistant via SolaX Modbus Integration No Yes (3389) No Yes (502)
Home Assistant / SolisCloud Simultaneous Yes Yes No No
Home Assistant via Solis API Yes Yes Yes Yes

(*) First reported working in April 2023; however, there are mixed messages from users complaining about the SolisCloud Remote Control with legacy dataloggers.

Current Data Loggers

These are currently being sold and supported by Solis:

S3-WiFi-ST

S3

This seems to be the most common datalogger supplied with new systems. WiFi only. With it, you can:

Without additional hardware or its firmware modification, you cannot directly connect to Home Assistant via Modbus TCP.

To modify its firmware (do at your own risk):

You can get Home Assistant and Soliscloud without modifying its firmware if you follow this approach: https://github.com/alienatedsec/solis-ha-modbus-cloud

S2-WL-ST

S2

Less common but available to purchase in the UK. This has WiFi and wired LAN. With it, you can:

if you connect directly to the inverter from Home Assistant you will lose SolisCloud connectivity unless you use additional hardware such as this approach: https://github.com/alienatedsec/solis-ha-modbus-cloud

Legacy Data Loggers

These are no longer being sold or supported by Solis:

DLS-L

DLS-L

These are LAN-only devices. What you can do with them seems to vary according to serial number but may include:

You may be able to access SolisCloud and Home Assistant simultaneously with these dataloggers

DLS-W

DLS-W

These are pretty much unobtainable now. They communicate using Modbus RTU encapsulated in the proprietary Solarman v5 protocol. To use these you need:

Other Harwdware

There are a number of other direct ModBus approaches: