Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

JK BMS stop reporting Voltage, Amperes, Soc, etc. Report most of the remain values without problems. #235

Open
Delphinus44 opened this issue Jun 19, 2024 · 5 comments

Comments

@Delphinus44
Copy link

A couple of months ago 1 of my 3 BMS stop reporting V, A, W, charge but the report the remain values, this week a second BMS start with same behavior, at the moment only one of the BMS reports 100% of the values, there was no change in BMS, Batmon and Hassio.

@Tobfaer
Copy link

Tobfaer commented Jun 23, 2024

I have the same issue since a couple of days. First it was intermittend, now its permanent. SOC, W, A, are no longer being displayed, all values are zero. Voltages however (min, max, average, min cell, max cell....) are completely fine and continue to be displayed. No changes were done to the system. In the JKBMS app all values are correctly reported.

Logs:
21:34:00 INFO [bt] BT Discovery:
21:34:00 INFO [bt] BT Discovery:
21:34:06 INFO [bt] BT C4:47:8C:EA:C3:F8 JK_B1A8S20P
21:34:06 INFO [jikong] normal connect failed ([org.bluez.Error.Failed] Input/output error), connecting with scanner
21:34:39 INFO [sampling] connected bms JKBt(C4:47:8C:EA:C3:F8,JKBMS)!
21:34:40 INFO [sampling] Sending HA discovery for JKBMS (num_samples=1237)
21:38:03 INFO [sampling] JKBMS: BmsSampl(0.0%,U=0.0V,I=0.00A,P=0W,Q=17826/0Ah,mos=0°C)
21:38:03 INFO [sampling] JKBMS volt=[3321,3321,3322,3321,3320,3320,3320,3321] temp=[0.0, 0.0]
21:39:41 INFO [sampling] Sending HA discovery for JKBMS (num_samples=1513)
21:44:42 INFO [sampling] Sending HA discovery for JKBMS (num_samples=1788)
21:48:05 INFO [sampling] JKBMS: BmsSampl(0.0%,U=0.0V,I=0.00A,P=0W,Q=17760/0Ah,mos=0°C)
21:48:05 INFO [sampling] JKBMS volt=[3323,3325,3323,3326,3322,3323,3323,3323] temp=[0.0, 0.0]
21:49:43 INFO [sampling] Sending HA discovery for JKBMS (num_samples=2063)
21:53:06 INFO [sampling] JKBMS: BmsSampl(0.0%,U=0.0V,I=0.00A,P=0W,Q=17760/0Ah,mos=0°C)
21:53:06 INFO [sampling] JKBMS volt=[3325,3325,3325,3323,3322,3323,3322,3322] temp=[0.0, 0.0]

@haselnuss1971
Copy link

i have the same issue. One of 3 BMS has Problems...
07:34:42 INFO [sampling] Block3 subscribing for {'charge': False, 'discharge': False, 'balance': True} switch change
07:34:42 INFO [sampling] Block3: BmsSampl(0.0%,U=0.0V,I=0.00A,P=0W,Q=4163895/0Ah,mos=nan°C)
07:34:42 INFO [sampling] Block3 volt=[3324,3327,3326,3326,3326,3326,3327,3326,3328,3327,3327,3327,3326,3327,3327,3326] temp=[nan, nan]

@haselnuss1971
Copy link

for completeness:
In the App (JK), all values are displayed correct.

@alinfulger
Copy link

Easiest workaround is to connect with the app to JK BMS and just modify Capacity to different number and then back to real capacity. For me, this has restored the functionality of Voltage / Ampere / Power readings.

@esther1112
Copy link

Easiest workaround is to connect with the app to JK BMS and just modify Capacity to different number and then back to real capacity. For me, this has restored the functionality of Voltage / Ampere / Power readings.

This worked for us. Don't turn the BMS off or on, just do amp hour settings via app as instructed, all figure back to what they should be now. Thankyou

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment