FS-11275 180/183 after 200 causes call to stall and never recovers #129
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Hi,
This PR will fix the issue https://freeswitch.org/jira/browse/FS-11275, the root cause is once the 180/183 message behind the 200 message (network jetter), sofia will to waiting the ACK for 180/183, until timeout.
The solution is, ignore the 180/183 if current state already is completed.
Please help review and merge the change.