Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathgsdevice.py
executable file
·312 lines (255 loc) · 11 KB
/
gsdevice.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
#!/usr/bin/env python3
import sys
import dbus
import dbus.mainloop.glib
import time
import logging
import requests
import datetime
from gi.repository import GLib
dbus.mainloop.glib.DBusGMainLoop(set_as_default=True)
sys.path.insert(0, '/opt/victronenergy/vrmlogger/ext/velib_python')
from vedbus import VeDbusService
logging.getLogger().setLevel(logging.INFO)
baseurl = sys.argv[1]
baseinstance = int(sys.argv[2]) if len(sys.argv) > 2 else 50
class Unitizer:
total = 0
time_unit = datetime.timedelta(milliseconds = 1000)
time_last = datetime.datetime.now()
def __init__(self, u, t = 0):
self.time_unit = u
self.total = t
def get(self):
return self.total
def add(self, v):
ct = datetime.datetime.now()
lt = self.time_last
dt = ct - lt
du = dt.total_seconds() / self.time_unit.total_seconds()
self.total += v * du
self.time_last = ct
return self.get()
class Roll:
def __init__(self, n, v=None):
self.v = v
self.n = n
def add(self, x):
tot = (self.v or x) * self.n
self.v = (tot + x) / (self.n + 1)
return self.v
class Value(dbus.Double):
def __new__(cls, v, f):
return super(Value, cls).__new__(cls, v)
def __init__(self, v, f):
dbus.Double.__init__(v)
self.f = f
def __str__(self):
return str(self.f) % self
class Device:
proxy=None
def __init__(self, type, id, name, ident=None, conn=baseurl):
self.bus = dbus.SystemBus(private=True)
self.id = id
self.ident = ident or 'gs_%s' % (id)
self.name = 'com.victronenergy.%s.%s' % (type, self.ident)
logging.info('[%-40s] Initializing [%s] as a [%s] with instance %d', self.name, name, type, id)
self.svc = VeDbusService(self.name, self.bus)
self.svc.add_path('/Mgmt/ProcessName', 'gsdevice.py')
self.svc.add_path('/Mgmt/ProcessVersion', '1.0')
self.svc.add_path('/Mgmt/Connection', conn)
self.svc.add_path('/DeviceInstance', id)
self.svc.add_path('/ProductId', 0xFFFF)
self.svc.add_path('/ProductName', name)
self.svc.add_path('/CustomName', name)
self.svc.add_path('/Model', name)
self.svc.add_path('/Connected', 1)
self.svc.add_path('/Role', type)
self.svc.add_path('/HardwareVersion', '0.0.0')
self.svc.add_path('/FirmwareVersion', '0.0.0')
self.svc.add_path('/Serial', 'GS%d' % id)
def set_path(self, path, value, writeCallback=None):
logging.debug('[%-40s] Setting %s to %s', self.name, path, value)
if not path in self.svc:
logging.info('[%-40s] Exporting %-40s initially as %s', self.name, path, value)
self.svc.add_path(path, None, writeable=(writeCallback is not None), onchangecallback=writeCallback)
proxy = self.proxy or self.svc
proxy[path] = value
def set_mode(self, path, mode):
print((path, mode))
def __enter__(self):
self.proxy = self.svc.__enter__()
return self
def __exit__(self, *exc):
self.proxy = None
self.svc.__exit__(exc)
def inverter_command(cmd):
if cmd is None: return False
logging.info('Inverter Command: %s', cmd)
x = requests.post(baseurl + '/cmd', data = {'cmd': cmd}, timeout = 5)
time.sleep(1)
return x
def ftoc(val):
return (val - 32) * (5/9)
temperature = Device('temperature', baseinstance + 1, 'GS Temperature')
temperature.set_path('/ProductId', 0xa162)
temperature.set_path('/TemperatureType', 2)
temperature.set_path('/Status', 0)
temperature.set_path('/Temperature', None)
fanA = Device('tank', baseinstance + 5, 'GS Fan A')
fanA.set_path('/ProductId', 41313)
fanA.set_path('/FluidType', 2)
fanA.set_path('/Level', None)
fanA.set_path('/Temperature', None)
fanB = Device('tank', baseinstance + 6, 'GS Fan B')
fanB.set_path('/ProductId', 41313)
fanB.set_path('/FluidType', 2)
fanB.set_path('/Level', None)
fanB.set_path('/Temperature', None)
fanC = Device('tank', baseinstance + 7, 'GS Fan C')
fanC.set_path('/ProductId', 41313)
fanC.set_path('/FluidType', 2)
fanC.set_path('/Level', None)
fanC.set_path('/Temperature', None)
fanD = Device('tank', baseinstance + 8, 'GS Fan D')
fanD.set_path('/ProductId', 41313)
fanD.set_path('/FluidType', 2)
fanD.set_path('/Level', None)
fanD.set_path('/Temperature', None)
inverter = Device('vebus', baseinstance + 0, 'GS Inverter')
inverter.set_path('/Ac/NumberOfPhases', 1)
inverter.set_path('/Ac/NumberOfAcInputs', 1)
inverter.set_path('/Ac/ActiveIn/ActiveInput', 0)
inverter.set_path('/State', None)
inverter.set_path('/Ac/PowerMeasurementType', 4)
def set_input_limitI(path, limit):
try:
logging.info('Informed to set Input Limit to %s', limit)
inverter.set_path('/Ac/ActiveIn/CurrentLimit', limit)
except:
logging.info('... failed')
inverter.set_path('/Ac/ActiveIn/CurrentLimitIsAdjustable', 1)
inverter.set_path('/Ac/ActiveIn/CurrentLimit', 25, set_input_limitI)
def set_mode(path, mode):
try:
logging.debug('Informed to set mode... %s', mode)
cmd = ['ATSinv','PWRoff'] if mode == 4 else ['ATSac','CHGoff'] if mode == 3 else ['ATSinv','PWRon'] if mode == 2 else ['ATSac','CHGblk'] if mode == 1 else None
status = [inverter_command(x) for x in cmd]
if cmd is not None:
inverter.set_path('/Mode', mode)
except:
logging.info('... failed')
inverter.set_path('/ModeIsAdjustable', 1)
inverter.set_path('/Mode', None, set_mode)
rn = 10
inverter.p_in = Roll(rn)
inverter.p_ou = Roll(rn)
inverter.i_dc = Roll(rn)
inverter.d_io = Unitizer(datetime.timedelta(hours = 1))
inverter.d_iv = Unitizer(datetime.timedelta(hours = 1))
inverter.d_vo = Unitizer(datetime.timedelta(hours = 1))
def update():
try:
stats = requests.get(url=baseurl + '/stats.json', timeout = 10).json()
f_in = stats['outputs']['outHZ']
v_in = stats['inputs']['inV']
i_in = stats['inputs']['inA']
p_in = v_in * i_in
f_ou = stats['outputs']['outHZ']
v_ou = stats['outputs']['outV']
i_ou = stats['outputs']['outA']
p_ou = stats['outputs']['outW']
e_tf = stats['outputs']['xfEFF'] / 100
i_tf = stats['inputs']['xfA']
v_dc = stats['inputs']['battV']
i_dc = (p_in - p_ou) / v_dc
p_dc = v_dc * i_dc
p_total = stats['stats']['KWh']
t_tta = stats['temps']['TTA']
t_ttb = stats['temps']['TTB']
t_tma = stats['temps']['TMA']
t_tmb = stats['temps']['TMB']
f_fa = stats['fans']['FA']
f_fb = stats['fans']['FB']
f_fc = stats['fans']['FC']
f_fd = 0 #No such Fan
s_inv = stats['stats']['invSTATES'] & 0xF
f_inv = stats['stats']['inFLAGS']
m_ats = s_inv == 1
m_chg = 4 if not f_inv & 0x10 else 3 if f_inv & 0x20 else 1
##With Off meaning Passthru
m_ve = 2 if not m_ats else m_chg
s_ve = 3 if m_ve == 1 else 9 if m_ve == 2 else 5 if m_ve == 3 else 8 if m_ve == 4 else None
##With Off meaning Off
m_ve = 4 if s_inv == 0x3 else 2 if s_inv == 0x2 else 3 if s_inv == 0x1 and m_chg == 4 else 1 if s_inv == 0x1 else None
s_ve = 3 if m_ve == 1 else 9 if m_ve == 2 else 8 if m_ve == 3 else 0 if m_ve == 4 else None
a_alarms = {}
a_alarms_alms = stats['errors']['Alms']
a_alarms_bits = { ##Bearing in mind this is TCP based... if carrier is lost from outage, we can't access it...
0 : ('/Alarms/TemperatureSensor', 1), #"Xfrmr Temp",
1 : ('/Alarms/TemperatureSensor', 1), #"MOS Temp",
2 : ('/Alarms/L1/Overload', 1), #"Overload",
3 : ('/Alarms/VoltageSensor', 1), #"Output Volt",
4 : ('/Alarms/LowBattery', 1), #"Batt. Low",
5 : ('/Alarms/VoltageSensor', 1), #"Batt. High",
6 : ('/Alarms/PhaseRotation', 1), #"Input Freq.",
7 : ('/Alarms/GridLost', 1), #"Input Volt",
8 : ('/Alarms/HighTemperature', 2), #"OVERHEAT",
9 : ('/Alarms/L1/Overload', 2), #"OVERLOAD LO",
10 : ('/Alarms/L1/Overload', 2), #"OVERLOAD HI",
}
for b, (path, value) in a_alarms_bits.items(): a_alarms[path] = value if (a_alarms_alms & 1<<b) else 0
with inverter as inverterP, fanA as fanAP, fanB as fanBP, fanC as fanCP, fanD as fanDP, temperature as temperatureP:
for path, value in a_alarms.items(): inverterP.set_path(path, value) #Dictionary prevents spamming dbus...
temperatureP.set_path('/Temperature', ftoc(max(t_tta, t_ttb, t_tma, t_tmb)))
inverterP.set_path('/ModeIsAdjustable', 1)
inverterP.set_path('/Ac/ActiveIn/CurrentLimitIsAdjustable', 1)
inverterP.set_path('/Mode', m_ve) ##VE Translated Mode, 1,2,3,4 => Charge Only, Inverter Only, On, Off
inverterP.set_path('/State', s_ve) ##VE Translated State, 0=Off;1=Low Power;2=Fault;3=Bulk;4=Absorption;5=Float;6=Storage;7=Equalize;8=Passthru;9=Inverting;10=Power assist;11=Power supply
inverterP.set_path('/Debug/m_ats', m_ats)
inverterP.set_path('/Debug/m_chg', m_chg)
inverterP.set_path('/Debug/m_ve', m_ve)
inverterP.set_path('/Debug/s_inv', s_inv)
inverterP.set_path('/Debug/f_inv', f_inv)
inverterP.set_path('/Ac/Out/L1/V', Value(v_ou, '%.2f V'))
inverterP.set_path('/Ac/Out/L1/I', Value(i_ou, '%.2f A'))
inverterP.set_path('/Ac/Out/L1/P', Value(p_ou, '%.2f W'))
inverterP.set_path('/Ac/Out/L1/F', Value(f_ou, '%.2f Hz'))
inverterP.set_path('/Ac/ActiveIn/L1/V', Value(v_in, '%.2f V'))
inverterP.set_path('/Ac/ActiveIn/L1/I', Value(i_in, '%.2f A'))
inverterP.set_path('/Ac/ActiveIn/L1/P', Value(p_in, '%.2f W'))
inverterP.set_path('/Ac/ActiveIn/L1/F', Value(f_in, '%.2f Hz'))
inverterP.set_path('/Dc/0/Voltage', Value(v_dc, '%.2f V'))
inverterP.set_path('/Dc/0/Current', Value(i_dc, '%.2f A'))
inverterP.set_path('/Dc/0/Power', Value(p_dc, '%.2f W'))
#inverterP.set_path('/Energy/InverterToAcOut', Value(p_total, '%.6f kWh'))
d_io = p_ou - max(0, -p_dc)
d_iv = p_in - p_ou
d_vo = p_ou - p_in
inverter.d_io.add(max(0, d_io))
inverter.d_iv.add(max(0, d_iv))
inverter.d_vo.add(max(0, d_vo))
inverterP.set_path('/Debug/d_io', Value(d_io, '%f W'))
inverterP.set_path('/Debug/d_iv', Value(d_iv, '%f W'))
inverterP.set_path('/Debug/d_vo', Value(d_vo, '%f W'))
inverterP.set_path('/Energy/AcIn1ToAcOut', Value(inverter.d_io.get() / 1000, '%.6f kWh'))
inverterP.set_path('/Energy/AcIn1ToInverter', Value(inverter.d_iv.get() / 1000, '%.6f kWh'))
inverterP.set_path('/Energy/InverterToAcOut', Value(inverter.d_vo.get() / 1000, '%.6f kWh'))
fanAP.set_path('/Level', f_fa)
fanAP.set_path('/Temperature', ftoc(t_tta))
fanBP.set_path('/Level', f_fb)
fanBP.set_path('/Temperature', ftoc(t_ttb))
fanCP.set_path('/Level', f_fc)
fanCP.set_path('/Temperature', ftoc(t_tma))
fanDP.set_path('/Level', f_fd)
fanDP.set_path('/Temperature', ftoc(t_tmb))
except IOError as e:
print('Unable to get data... %s' % str(e))
except Exception as e:
print('Unknown Exception... %s' % e)
return True
def main():
mainloop = GLib.MainLoop()
GLib.timeout_add(1000, update)
mainloop.run()
main()