Metric | MQTT topic suffix | Unit | Modbus address (dec) | Modbus address (hex) | Modbus data type | Scale factor |
---|---|---|---|---|---|---|
Running status | inverter/status |
N/A (0: standby, 1: selfcheck, 2: normal, 3: alarm, 4: fault) | 500 | 1f4 | U_WORD | 1 |
PV1 Power | dc/pv1/power |
W | 672 | 2a0 | U_WORD | 10 |
PV2 Power | dc/pv2/power |
W | 673 | 2a1 | U_WORD | 10 |
PV3 Power | dc/pv3/power |
W | 674 | 2a2 | U_WORD | 10 |
PV4 Power | dc/pv4/power |
W | 675 | 2a3 | U_WORD | 10 |
DC Total Power | dc/total_power |
W | 672,673,674,675 | 2a0,2a1,2a2,2a3 | U_WORD | 10 |
PV1 Voltage | dc/pv1/voltage |
V | 676 | 2a4 | U_WORD | 0.1 |
PV1 Current | dc/pv1/current |
A | 677 | 2a5 | U_WORD | 0.1 |
PV2 Voltage | dc/pv2/voltage |
V | 678 | 2a6 | U_WORD | 0.1 |
PV2 Current | dc/pv2/current |
A | 679 | 2a7 | U_WORD | 0.1 |
PV3 Voltage | dc/pv3/voltage |
V | 680 | 2a8 | U_WORD | 0.1 |
PV3 Current | dc/pv3/current |
A | 681 | 2a9 | U_WORD | 0.1 |
PV4 Voltage | dc/pv4/voltage |
V | 682 | 2aa | U_WORD | 0.1 |
PV4 Current | dc/pv4/current |
A | 683 | 2ab | U_WORD | 0.1 |
Daily Production | day_energy |
kWh | 529 | 211 | U_WORD | 0.1 |
Total Production | total_energy |
kWh | 534,535 | 216,217 | U_DWORD (LW,HW) | 0.1 |
Total Grid Power | ac/total_power |
W | 625 | 271 | S_WORD | 1 |
Grid Voltage L1 | ac/l1/voltage |
V | 598 | 256 | U_WORD | 0.1 |
Grid Voltage L2 | ac/l2/voltage |
V | 599 | 257 | U_WORD | 0.1 |
Grid Voltage L3 | ac/l3/voltage |
V | 600 | 258 | U_WORD | 0.1 |
Internal CT L1 Power | ac/l1/ct/internal |
W | 604 | 25c | S_WORD | 1 |
Internal CT L2 Power | ac/l2/ct/internal |
W | 605 | 25d | S_WORD | 1 |
Internal CT L3 Power | ac/l3/ct/internal |
W | 606 | 25e | S_WORD | 1 |
External CT L1 Power | ac/l1/ct/external |
W | 616 | 268 | S_WORD | 1 |
External CT L2 Power | ac/l2/ct/external |
W | 617 | 269 | S_WORD | 1 |
External CT L3 Power | ac/l3/ct/external |
W | 618 | 26a | S_WORD | 1 |
Daily Energy Bought | ac/daily_energy_bought |
kWh | 520 | 208 | U_WORD | 0.1 |
Total Energy Bought | ac/total_energy_bought |
kWh | 522,523 | 20a,20b | U_DWORD (LW,HW) | 0.1 |
Daily Energy Sold | ac/daily_energy_sold |
kWh | 521 | 209 | U_WORD | 0.1 |
Total Energy Sold | ac/total_energy_sold |
kWh | 524,525 | 20c,20d | U_DWORD (LW,HW) | 0.1 |
Current L1 | ac/l1/current |
A | 630 | 276 | S_WORD | 0.01 |
Current L2 | ac/l2/current |
A | 631 | 277 | S_WORD | 0.01 |
Current L3 | ac/l3/current |
A | 632 | 278 | S_WORD | 0.01 |
Inverter L1 Power | ac/l1/power |
W | 633 | 279 | S_WORD | 1 |
Inverter L2 Power | ac/l2/power |
W | 634 | 27a | S_WORD | 1 |
Inverter L3 Power | ac/l3/power |
W | 635 | 27b | S_WORD | 1 |
DC Temperature | radiator_temp |
°C | 540 | 21c | S_WORD | 0.1 |
AC Temperature | ac/temperature |
°C | 541 | 21d | S_WORD | 0.1 |