diff --git a/server/scripts/sequence-doc/src/version/Current G36 Decisions/Guideline 36-2021 (mappings).csv b/server/scripts/sequence-doc/src/version/Current G36 Decisions/Guideline 36-2021 (mappings).csv index 44955e77..7f3c2036 100644 --- a/server/scripts/sequence-doc/src/version/Current G36 Decisions/Guideline 36-2021 (mappings).csv +++ b/server/scripts/sequence-doc/src/version/Current G36 Decisions/Guideline 36-2021 (mappings).csv @@ -74,14 +74,14 @@ The list of options should be revised in the template." ,MZVAV,MZVAV,,Buildings.Templates.AirHandlersFans.VAVMultiZone,, ,SZVAV,SZVAV,,,,NOT implemented in Templates. Covered by G36. ,DFDD,DFDD,,,,NOT implemented in Templates. Covered by G36. -,Pressure Control:,BSP,Y,Buildings.Templates.AirHandlersFans.Components.Interfaces.PartialControllerVAVMultizone.buiPreCon-ctl.buiPreCon,Buildings.Controls.OBC.ASHRAE.G36.Types.BuildingPressureControlTypes, -,Barometric relief (no fan),BARO,,,Buildings.Controls.OBC.ASHRAE.G36.Types.BuildingPressureControlTypes.BarometricRelief,NOT implemented in Templates. Covered by G36. -,Actuated relief damper (no fan),DMPR,,,Buildings.Controls.OBC.ASHRAE.G36.Types.BuildingPressureControlTypes.ReliefDamper, +,Pressure Control:,BSP,Y,Buildings.Templates.AirHandlersFans.Components.Interfaces.PartialControllerVAVMultizone.buiPreCon-ctl.buiPreCon,Buildings.Controls.OBC.ASHRAE.G36.Types.PressureControl, +,Barometric relief (no fan),BARO,,,Buildings.Controls.OBC.ASHRAE.G36.Types.PressureControl.BarometricRelief,NOT implemented in Templates. Covered by G36. +,Actuated relief damper (no fan),DMPR,,,Buildings.Controls.OBC.ASHRAE.G36.Types.PressureControl.ReliefDamper, ,Barometric damper with relief fan,RELIEF,,,,NOT implemented in Templates (nor in Buildings.Controls.OBC.ASHRAE.G36). Covered by G36. -,Actuated relief damper with relief fan,RELIEFDMPR,,,Buildings.Controls.OBC.ASHRAE.G36.Types.BuildingPressureControlTypes.ReliefFan, -,Return fan - AF tracking (AMFS),RETURNTRACK,,,Buildings.Controls.OBC.ASHRAE.G36.Types.BuildingPressureControlTypes.ReturnFanMeasuredAir, -,Return fan - AF tracking (Calculated),,,,Buildings.Controls.OBC.ASHRAE.G36.Types.BuildingPressureControlTypes.ReturnFanCalculatedAir,Removed from Templates. Not properly described in G36. -,Return fan - Direct Building Pressure Control (DP),RETURNDP,,,Buildings.Controls.OBC.ASHRAE.G36.Types.BuildingPressureControlTypes.ReturnFanDp, +,Actuated relief damper with relief fan,RELIEFDMPR,,,Buildings.Controls.OBC.ASHRAE.G36.Types.PressureControl.ReliefFan, +,Return fan - AF tracking (AMFS),RETURNTRACK,,,Buildings.Controls.OBC.ASHRAE.G36.Types.PressureControl.ReturnFanMeasuredAir, +,Return fan - AF tracking (Calculated),,,,Buildings.Controls.OBC.ASHRAE.G36.Types.PressureControl.ReturnFanCalculatedAir,Removed from Templates. Not properly described in G36. +,Return fan - Direct Building Pressure Control (DP),RETURNDP,,,Buildings.Controls.OBC.ASHRAE.G36.Types.PressureControl.ReturnFanDp, ,Return fan - Speed tracking (SZVAV),RETURNSPD,,,,"Option for SZVAV, not implemented in Templates. Covered by G36." ,OA Damper Configuration and Measurement:,OA,Y,Buildings.Templates.AirHandlersFans.Components.OutdoorReliefReturnSection.MixedAirWithDamper.secOut-secOutRel.secOut,Buildings.Controls.OBC.ASHRAE.G36.Types.OutdoorAirSection, ,100% OA,100OA,,,Buildings.Controls.OBC.ASHRAE.G36.Types.OutdoorAirSection.NoEconomizer,NOT implemented in Templates. NOT covered by G36.