SolarEdge Monitoring

This project enables monitoring the performance data of SolarEdge inverters and optimizers. Solaredge supports the open Sunspec Alliance logging protocols, however this data is only accessible via an RS485 interface on the inverter and does not include module level (optimizer) data. Solaredge publishes an API that allows access to their portal, however this also does not include module level data.

semonitor.py is a program that implements a subset of the SolarEdge protocol. It can be used to parse the performance data that has been previously captured to a file, or it can interact directly with a SolarEdge inverter over the RS232, RS485, or ethernet interface. Performance data is output to a file in JSON format.

seextract.py is a program that can extract the SolarEdge protocol messages from a PCAP file that contains data captured from the network.

sekey.py is used to extract the unique encryption key from an inverter.

se2state.py follows a file containing JSON performance data and outputs a JSON file that contains the current state of the inverter and optimizer values.

se2csv.py reads a file containing JSON performance data and outputs two separate comma delimited files that contain inverter and optimizer data that is suitable for input to a spreadsheet.

semonitor.py

SolarEdge inverter performance monitoring using the SolarEdge protocol.

Usage

python semonitor.py [options] [datasource]

Arguments

datasource           Input filename or serial port.
                     If no data source is specified, the program reads from 
                     stdin, unless the data source type is network.
                     If a file name is specified, the program processes the 
                     data in that file and terminates, unless the -f option 
                     is specified, in which case it waits for further data 
                     to be written to the file.
                     If the data source corresponds to a serial port, 
                     process the data from that port.

Options

-a                   append to output file if the file exists
-b                   baud rate for serial data source (default: 115200)
-c cmd[/cmd/...]     send the specified command functions
-d debugfile         where to send debug messages (stdout|syslog|filename) 
                     (default: syslog)
-f                   wait for appended data as the input file grows 
                     (as in tail -f)
-k keyfile           file containing a hex encoded encryption key
-m                   function as a RS485 master
-n interface         run DHCP and DNS network services on the specified 
                     interface
-o outfile           write performance data to the specified file in 
                     JSON format (default: stdout)
-r recfile           file to record all incoming and outgoing messages to
-s inv[,inv,...]     comma delimited list of SolarEdge slave inverter IDs
-t 2|4|n             data source type (2=RS232, 4=RS485, n=network)
-v                   verbose output
-x                   halt on data exception

Notes

Data may be read from a file containing messages in the SolarEdge protocol that was previously created by seextract.py from a pcap file, or the output from a previous run of semonitor.py. It may also be read in real time from one of the RS232, RS485, or ethernet interfaces on a SolarEdge inverter.

Debug messages are sent to the system log, unless the -d option is specified. If an error occurs while processing data, the program will log a message and continue unless the -x option is specified.

The level of debug messaging is controlled using the -v option, which may be specified up to 4 times:

-v      log input parameters and file operations
-vv     log incoming and outgoing messages
-vvv    log the parsed data of incoming and outgoing messages
-vvvv   log the raw data of incoming and outgoing messages

Messages logged at the -vv level and above contain the device or file sending or receiving the message, the direction it was sent, the message size, and a sequence number. Separate sequences are kept for incoming and outgoing messages.

The -t option is used to specify the data source type for non-file input. If the data source is a serial port, the -t option must be included with either the values 2 or 4 to specify whether it is connected to the RS232 or RS485 port. If there is no data source specified and -t n is specified, semonitor.py will listen on port 22222 for a connection from an inverter.

To interact directly with an inverter over the network, semonitor.py must function as the SolarEdge monitoring server. This means that the host running semonitor.py must be connected to the inverter over the ethernet interface. In this configuration, semonitor.py may function as the DHCP server and the DNS server to provide an IP address to the inverter and to resolve the hostname of the SolarEdge server (usually prod.solaredge.com) to the IP address of the semonitor.py host. This requires that semonitor.py be run with elevated (root) priveleges in order to access the standard DHCP and DNS ports. The -n option specifies the name of the network interface that the inverter is connected to. If the inverter acquires an IP address and is able to resolve the server hostname by some other means, the -n option is not required.

The -c, -m, and -s options are not vaild if input is from a file or stdin.

The -m option is only valid if a serial port is specified, and one or more inverter IDs must be specified with the -s option. If this option is specified, there cannot be another master device on the RS485 bus. semonintor.py will repeatedly send commands to the specified inverters to request performance data.

The -c option may be specified for a serial device or the network. The option specifies one or more SolarEdge protocol command functions separated by a "/". Each command function consists of a hex function code followed by zero or more comma separated hex parameters. Each parameter must begin with one of the letters "B", "H", or "L" to designate the length of the parameter:

B = 8 bits
H = 16 bits
L = 32 bits

All function codes and parameters must be hexadecimal numbers, without the leading "0x". Exactly one inverter ID must be specified with the -s option. After each command is sent, semonitor.py will wait for a response before sending the next command. When all commands have been sent and responded to, the program terminates. Responses are sent to output.

Commands initiated by semonitor.py as the result of the -c or -m options need to maintain a monotonically increasing sequence number which is used as a transaction ID. A file named seseq.dat will be created to persist the value of this sequence number across multiple executions of semonitor.py.

Examples

python semonitor.py -o yyyymmdd.json yyyymmdd.dat

Read from SE data file yyyymmdd.dat and write data to the json file yyyymmdd.json.

python semonitor.py -o yyyymmdd.json -m -s 7f101234,7f105678 -t 4 COM4

Function as a RS485 master to request data from the inverters 7f101234 and 7f105678 using RS485 serial port COM4.

python semonitor.py -c 0012,H0329 -s 7f101234 -d stdout -vvv -t 2 /dev/ttyUSB0

Send a command to the inverter 7f101234 to request the value of parameter 0x0329 using RS232 serial port /dev/ttyUSB0. Display the messages on stdout.

python semonitor.py -c 0011,H329,L1/0012,H329/0030,H01f4,L0 -s 7f101234 -d stdout -vvv -t 2 /dev/ttyUSB0

Send commands to the inverter 7f101234 to set the value of parameter 0x0329 to 1, followed by a command to reset the inverter using RS232 serial port /dev/ttyUSB0. Display the debug messages on stdout.

sudo python semonitor.py -o yyyymmdd.json -n eth1

Start the dhcp and dns services on network interface eth1. Accept connections from inverters and function as a SolarEdge monitoring server. Write performance data to the file yyyymmdd.json. Because the -n option is specified, the -t n option is implied.

seextract.py

Read a PCAP file that is a capture of the traffic between a inverter and the SolarEdge monitoring server. Filter out the TCP stream between the inverter to the server.

Usage

python seextract.py [options] pcapFile

Arguments

pcapFile        pcap file or directory to read
                If a file is specified, the program processes the data in 
                that file and terminates, unless the -f option is specified, 
                in which case it waits for further data to be written to the 
                pcap file.
                If a directory is specified, all files in the directory are 
                processed.
                If a directory is specified and the -f option is specified, 
                only the file in the directory with the newest modified date 
                is processed and the program waits for further data in that 
                file.  If a new file is subsequently created in the 
                directory, the current file is closed and the new file 
                is opened. 

Options

-a              append to output files
-f              output appended data as the pcap file grows (as in tail -f)
-o outfile      output file to write
-s server       SolarEdge server hostname or IP address (default: 
                prod.solaredge.com)
-v              verbose output

Examples

python seextract.py -o yyyymmdd.dat yyyymmdd.pcap

Convert the data in file yyyymmdd.pcap and write the output to file yyyymmdd.dat

python seextract.py -o yyyymmdd.dat -f pcap/

Monitor PCAP files in directory pcap/ and write the output to the file yyyymmdd.dat.

python seextract.py -o allfiles.pcap pcap/

Convert all the pcap files found in directory pcap/ and write the output to files allfiles.pcap.

python seextract.py yyyymmdd.pcap | python semonitor.py -o yyyymmdd.json

Extract SolarEdge data from the file yyyymmdd.pcap using seextract.py, process it with semonitor.py, and write data to the json file yyyymmdd.json.

se2state.py

Maintain a JSON file containing the current state of SolarEdge inverters and optimizers.

Usage

python se2state.py options [inFile]

Arguments

inFile          File containing performance data in JSON format. (default:
                stdin)
                The program will follow (wait for new data to be written to)
                the file.

Options

-o stateFile    File containing the current (last read) data values for each
                inverter and optimizer values from the input file.  It will
                be overwritten every time that new data is read.

Examples

python semonitor.py -t n | tee yyyymmdd.json | python se2state.py -o solar.json

Accept connections from inverters over the network. Send performance data to the file yyyymmdd.json and also maintain the file solar.json with the current state. The inverter acquires its IP address and resolves the server hostname by a means other than semonitor.py.

sekey.py

Maintain a JSON file containing the current state of SolarEdge inverters and optimizers.

Usage

python sekey.py options [inFile]

Arguments

inFile          File containing the values of the 4 encryption key parameters
                of an inverter output from semonitor.py. (default: stdin)

Options

-o keyFile      File containing the hex encoded key. (Default: stdout)

Examples

python solaredge/semonitor.py -c 12,H239/12,H23a/12,H23b/12,H23c -s 7f101234 -t 2  /dev/ttyUSB0|python solaredge/sekey.py -o 7f101234.key

Read the parameters 0x0239-0x023c and write the key value to the file 7f101234.key.

se2csv.py

Convert SolarEdge inverter performance monitoring data from JSON to CSV.

Usage

python se2csv.py options [inFile]

Arguments

inFile          File containing performance data in JSON format. (default:
                stdin)

Options

-a              append to inverter and optimizer files
-d delim        inverter and optimizer file delimiter (default: ",")
-h              write column headers to inverter and optimizer files
-i invFile      file to write inverter data to
-o optFile      file to write optimizer data to

Examples

python se2csv.py -i yyyymmdd-inv.csv -o yyyymmdd-opt.csv -h yyyymmdd.json

Read from SE data file yyyymmdd.json and write inverter and optimizer data to the CSV files yyyymmdd-inv.csv and yyyymmdd-opt.csv with headers.