Sames. Happens even when just controlling speed on my BP04 [12/2/2023, 12:25:21 AM] [DysonPureCoolPlatform] serial removed meow - set RotationSpeed to 30: {"fnsp":"0003"} |
Same issue here. Anytime I interact with my BP03 I get the error and homebridge crashes.
|
Also getting the same issue with the BP03. Plugin is unusable. |
Same, looks like its being detected as the wrong device, or there is an assumption that all devices of that class has a swing mode which this one doesn't have. |
I loved the plugin but this error crashes the homebridge and everything restarts when I click on the Dyson BP04. A quick fix would be extreme helpful. Or could we just comment out the swing mode somehow? Which would be the correct lines to change? I don't know much about Typescript and js.
|
If you have a lot of other things talking to homebridge this would be a good opportunity to set up a child bridge for just the Dyson devices to minimize disruptions for the rest of your home. |
I receive the following error when turning the device on or off.
[11/28/2023, 7:36:18 PM] Homebridge v1.7.0 (HAP v0.11.1) (Homebridge 9283) is running on port 51435.
[11/28/2023, 7:36:26 PM] [DysonPureCoolPlatform] <serial # removed> - set Active to 0: {"fpwr":"OFF","fmod":"OFF"}
[11/28/2023, 7:36:26 PM] TypeError: Cannot read properties of undefined (reading '1')
at MqttClient. (/homebridge/node_modules/homebridge-dyson-pure-cool/src/dyson-pure-cool-device.js:675:111)
at MqttClient.emit (node:events:517:28)
at MqttClient._handlePublish (/homebridge/node_modules/homebridge-dyson-pure-cool/node_modules/mqtt/lib/client.js:940:12)
at MqttClient._handlePacket (/homebridge/node_modules/homebridge-dyson-pure-cool/node_modules/mqtt/lib/client.js:305:12)
at work (/homebridge/node_modules/homebridge-dyson-pure-cool/node_modules/mqtt/lib/client.js:261:12)
at Writable.writable._write (/homebridge/node_modules/homebridge-dyson-pure-cool/node_modules/mqtt/lib/client.js:271:5)
at doWrite (/homebridge/node_modules/homebridge-dyson-pure-cool/node_modules/readable-stream/lib/_stream_writable.js:428:64)
at writeOrBuffer (/homebridge/node_modules/homebridge-dyson-pure-cool/node_modules/readable-stream/lib/_stream_writable.js:417:5)
at Writable.write (/homebridge/node_modules/homebridge-dyson-pure-cool/node_modules/readable-stream/lib/_stream_writable.js:334:11)
at Socket.ondata (node:internal/streams/readable:777:22)
[11/28/2023, 7:36:26 PM] Got SIGTERM, shutting down Homebridge...
[11/28/2023, 7:36:31 PM] [HB Supervisor] Homebridge Process Ended. Code: 143, Signal: null
[11/28/2023, 7:36:36 PM] [HB Supervisor] Restarting Homebridge...
[11/28/2023, 7:36:36 PM] [HB Supervisor] Starting Homebridge with extra flags: -I -P /var/lib/homebridge/node_modules --strict-plugin-resolution
[11/28/2023, 7:36:36 PM] [HB Supervisor] Started Homebridge v1.7.0 with PID: 28487