I have compared the CINE pumping rates for HCN with output from my own code (which has been tested with respect to Biver et al. 2018, Bockelee-Morvan et al. 2004, and Crovisier & Le Bourlot 1983) and they do not seem to be correct - the dominant transitions should be those with delta(J)=2.
The text was updated successfully, but these errors were encountered:
mcordiner
changed the title
Pumping rates incorrect for CO and HCN
Pumping rates incorrect for HCN
Nov 19, 2018
I have compared the CINE pumping rates for HCN with output from my own code (which has been tested with respect to Biver et al. 2018, Bockelee-Morvan et al. 2004, and Crovisier & Le Bourlot 1983) and they do not seem to be correct - the dominant transitions should be those with delta(J)=2.