-
Notifications
You must be signed in to change notification settings - Fork 14
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
related with SynMock #82
Comments
Thanks for question @mbcarbonetto. FYI, this was published several years ago here: https://peerj.com/articles/4925/. In the paper we did essentially two different things: 1) PCR amplified the product from each plasmid separately, cleaned up, quantified, and mixed equally -- this serves as the sequencing control (Stds in some of the heat map figures) and 2) mixed plasmids equally used as template DNA for PCR (we tested this at various concentrations (supplemental). We did not try to linearize and see if there would be differences there -- I suppose plausible. Since we were focused in this paper on using these data to build a computational pipeline that worked for variable length amplicons (ITS) we largely focused on the PCR/sequencing bias we were seeing in our environmental samples and then of course these biological/synthetic mock samples. But I think the DNA extraction bias is also a very important point -- so we had on our radar to do some spike-in experiments, but effectively those experiments never got done. There is just a lot of variability in microbes, my view essentially is that fungi certainly have a diverse set of properties that are undoubtably going to effect DNA extraction in a mixed community when you consider that aspect and then also consider that PCR is biasing those results further -- it makes it really difficult for me to believe that the read abundance numbers are representative of the underlying fungal community. |
Thanks a lot for your answer! I agree with the fact that just adding the SynMock plasmids on the samples before DNA extraction will not properly reflect extraction biases due to differences in cell properties and quantifications based on the spiked- plasmids will be then biased. Thanks for the development of the pipeline, I will give it a try myself soon. If any issues arise will come back here. |
Hello, not sure if this is the right place to ask this question, but I will give it a try. As regards the publication i: https://doi.org/10.1101/213470, have you added the SynMock plasmids directly into samples before DNA extraction, or after? have you linearised them?
thanks!
The text was updated successfully, but these errors were encountered: