Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathsimple_IQ.m
159 lines (133 loc) · 5.08 KB
/
simple_IQ.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
%% IQ heterodyne measurement, AOM + PIC PM
% Michael Nickerson 2022-01-07
clear; close('all');
%% Setup
% Device parameters
die = '121.1D1.5';
dev = '12';
lambda = 1030;
pol = 1; % 0 = zero, 1 = high EA, 2 = low EA
% Measurement Parameters
waitPol = 1; % Wait for human to adjust polarization?
coupleMinPow = 65e-6; % Run coupling if under this power; 0 to disable
measurement = 'IQgsg';
rfFreq = round(10.^linspace(log10(10e6), log10(2.9e8), 20), 4, 'significant')'; % PD doesn't work past ~200MHz
% rfFreq = round(10.^linspace(log10(5e5), log10(25e6), 15), 4, 'significant')';
rfAmp = 1;
dcMax = -2; % Maximum bias to apply
dcMin = -20; % Minimum bias to apply
dcStep = -rfAmp*2;
% Optionally override standard bias calculations
dcVals = (dcMax-rfAmp/2):-abs(dcStep):(-abs(dcMin)+rfAmp/2);
% Remove rfFreq too close to AOM frequency
rfFreq = rfFreq(mod(rfFreq, 150e6) >= 4e5);
% Equipment settings
dcDMM = 'GPIB16';
aomDMM = 'GPIB26';
setDG = @setMG3690; % DG function, defined at end
% setDG = @setDG1022;
dsoAddr = mapDSO('Station2USB').visaAddr;
pmID = 'Station2';
dsoChPD = 4; % 1 = high speed DET10C, 4 = amplified PDA05CF2
dsoChV = 2; % Applied voltage
dsoChAOM = 3; % AOM RF
dmmWires = 2;
Ilim = 5e-3; % Compliance current
dcPol = -15; % Bias for polarization setting
dsoMinF = min(mod(rfFreq, 150e6))/10;% Minimum acquired Nyquist frequency; /10 for minimum 10 periods
dsoTime = min(1/dsoMinF, 1e-4);% DSO timescale, max 1e-3 ~= 32MB traces (for highest resolution acquisition)
dsoVDC = 0; % DSO ChV measuring DC?
dsoVZ = 'low'; % DSO ChV impedance
% Set up save names
savName = @(freq) sprintf('%s_%s-%s_%s-PD%i-%.5gV@%.5gHz-p%i_%s', datestr(now, 'yyyymmdd'), ...
die, dev, measurement, dsoChPD, rfAmp, freq, pol, datestr(now, 'Thhmmss.FFF'));
savPath='~/labshare/measurements/station2';
%% Run
% Process variables
rfAmp = abs(rfAmp); % Used in various calculations assuming positivity
rfFreq = rfFreq(randperm(length(rfFreq))); % Randomly permute to avoid conflating time and frequency
% Initialize equipment
ifaceDMM(dcDMM, 'avg', 0, 'off', 'ilimit', Ilim, 'w', dmmWires);
setDSOImpedance(dsoAddr, dsoChV, dsoVZ);
visaWrite(dsoAddr, ':RUN');
% Set polarization
if waitPol == 1
setDG('off');
ifaceDMM(dcDMM, 'voltage', dcPol, 'on');
visaWrite(dsoAddr, sprintf(':TIM:RANG %g', 10/150e6)); % Set DSO timescale to capture maximum points
input(sprintf('Adjust PIC polarization to %i\n via DMM current then press return...', pol));
ifaceDMM(dcDMM, 'off');
ifaceDMM(aomDMM, 'on');
input('Adjust AOM polarization\n then press return...');
end
% Set equipment state
ifaceDMM(dcDMM, 'voltage', dcVals(1), 'off');
visaWrite(dsoAddr, sprintf(':TIM:RANG %g', dsoTime));
setDG('offset', 0, 'amp', rfAmp, 'off', 'sine');
% Start measurement loop
fprintf('Running %s sweep of %s-%s p%i\n', measurement, die, dev, pol);
for i = 1:numel(rfFreq)
% Run coupling if needed
if coupleMinPow > 0
ifaceDMM(aomDMM, 'off');
setDG('off');
ifaceDMM(dcDMM, 'off');
% Run coupling if needed
if ifacePM(pmID, 'softavg', 0.5) < coupleMinPow
doCouple(aomDMM, dcDMM, setDG);
end
end
% Next frequency
freq = rfFreq(i);
fprintf('(%i/%i) Freq: %.4gHz\n ', i, numel(rfFreq), freq);
% Set equipment state
setDG('freq', freq, 'on');
ifaceDMM(aomDMM, 'on');
ifaceDMM(dcDMM, 'voltage', dcVals(1), 'on');
visaWrite(dsoAddr, sprintf(':CHAN%i:RANG %g;:CHAN%i:OFFS %g', dsoChV, rfAmp*2, dsoChV, dcVals(1)*dsoVDC));
lastOutB = 0;
for j = 1:numel(dcVals)
dcOff = dcVals(j);
% Update progress
fprintf(repmat('\b', [1 lastOutB]));
lastOutB = fprintf('(%i/%i) Bias: %.2f%V.. ', j, numel(dcVals), dcOff);
% Set equipment state
ifaceDMM(dcDMM, 'voltage', dcOff);
visaWrite(dsoAddr, sprintf(':CHAN%i:OFFS %g', dsoChV, dcOff*dsoVDC));
pause(0.05); % Wait for it to settle
% Capture traces and save
[Y123, X] = dev_DSOgetTrace([dsoChPD, dsoChV, dsoChAOM], dsoAddr, 0, round(dsoTime*4e9));
save([savPath savName(freq) '.mat']);
end
fprintf(repmat('\b', [1 lastOutB+2]));lastOutB = 0;
fprintf('; done.\n');
end
fprintf('\nDone measuring\n');
%% Clean up
setDG('off');
ifaceDMM(dcDMM, 'off', 'avg', 0, 'voltage', dcPol);
ifaceDMM(aomDMM, 'off');
visaWrite(dsoAddr, sprintf(':TIM:RANG %g;:CHAN%i:OFFS %g', 10/150e6, dsoChV, dcPol));
%% Helper functions
function doCouple(aomDMM, dcDMM, setDG)
% Turn off AOM and applied voltage first
ifaceDMM(aomDMM, 'off');
ifaceDMM(dcDMM, 'off');
setDG('off');
% Run coupling
simple_CouplePM;
clear; close('all');
end
function r = setDG1022(varargin)
r = dev_DG1022setWave(mapDMM('DG1022').visaAddr, 1, varargin{:});
end
function r = setMG3690(varargin)
r = dev_MG3690setWave(mapDMM('MG3694C').visaAddr, varargin{:});
end
function setDSOImpedance(dsoAddr, ch, Z)
if strcmpi(Z, 'low')
visaWrite(dsoAddr, sprintf(':CHAN%i:IMP FIFT', ch));
else
visaWrite(dsoAddr, sprintf(':CHAN%i:IMP ONEM', ch));
end
end