diff --git a/_static/schematics/ibal.pdf b/_static/schematics/ibal.pdf
new file mode 100644
index 00000000..d7ff7c08
Binary files /dev/null and b/_static/schematics/ibal.pdf differ
diff --git a/_toc.yml b/_toc.yml
index bd98a707..65f64e75 100644
--- a/_toc.yml
+++ b/_toc.yml
@@ -9,6 +9,7 @@ parts:
chapters:
- file: examples/lbnl-example.md
- file: examples/NREL-example.md
+ - file: examples/ibal.md
- caption: Example Systems
chapters:
- file: examples/guideline36-2021-4.1.md
diff --git a/examples/guideline36-2021-4.2.md b/examples/guideline36-2021-4.2.md
index fa2c33d7..4e33ac99 100644
--- a/examples/guideline36-2021-4.2.md
+++ b/examples/guideline36-2021-4.2.md
@@ -4,8 +4,26 @@ This component model is an example of the variable air volume (VAV) terminal uni
## Downloads
-
+- Turtle file
+- JSON-LD file
+
## Queries
## Model Components
+| Parent Class | Class | Instances |
+|------------|-------|----------------|
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Actuator](https://explore.open223.info/s223/Actuator.html) | 2 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Sensor](https://explore.open223.info/s223/Sensor.html) | 2 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Damper](https://explore.open223.info/s223/Damper.html) | 1 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [HeatingCoil](https://explore.open223.info/s223/HeatingCoil.html) | 1 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Valve](https://explore.open223.info/s223/Valve.html) | 1 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [SingleDuctTerminal](https://explore.open223.info/s223/SingleDuctTerminal.html) | 1 |
+| [Connection](https://explore.open223.info/s223/Connection.html) | [Duct](https://explore.open223.info/s223/Duct.html) | 3 |
+| [Connection](https://explore.open223.info/s223/Connection.html) | [Pipe](https://explore.open223.info/s223/Pipe.html) | 3 |
+| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [OutletConnectionPoint](https://explore.open223.info/s223/OutletConnectionPoint.html) | 6 |
+| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [InletConnectionPoint](https://explore.open223.info/s223/InletConnectionPoint.html) | 6 |
+| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableProperty](https://explore.open223.info/s223/QuantifiableProperty.html) | 6 |
+| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableObservableProperty](https://explore.open223.info/s223/QuantifiableObservableProperty.html) | 4 |
+| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableActuatableProperty](https://explore.open223.info/s223/QuantifiableActuatableProperty.html) | 2 |
+
diff --git a/examples/ibal.md b/examples/ibal.md
new file mode 100644
index 00000000..f67a3dec
--- /dev/null
+++ b/examples/ibal.md
@@ -0,0 +1,45 @@
+# NIST Intelligent Buildings Agents Laboratory
+
+This is a model of the Intelligent Buildings Agents Laboratory (IBAL) at NIST.
+
+The schematics of the air and hydronic systems can be found [here](_static/schematics/ibal.pdf)
+
+## Downloads
+
+- Turtle file
+- JSON-LD file
+
+## Queries
+| Description | Query URL |
+|-------------|-----------|
+| Zone/room temperature sensors | [Query Link](https://query.open223.info/?query=PREFIX+s223%3A+%3Chttp%3A%2F%2Fdata.ashrae.org%2Fstandard223%23%3E+PREFIX+unit%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Funit%2F%3E+PREFIX+rdfs%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2000%2F01%2Frdf-schema%23%3E+PREFIX+rdf%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E+PREFIX+quantitykind%3A+%3Chttp%3A%2F%2Fqudt.org%2Fvocab%2Fquantitykind%2F%3E+PREFIX+qudt%3A+%3Chttp%3A%2F%2Fqudt.org%2Fschema%2Fqudt%2F%3E+PREFIX+sh%3A+%3Chttp%3A%2F%2Fwww.w3.org%2Fns%2Fshacl%23%3E+PREFIX+owl%3A+%3Chttp%3A%2F%2Fwww.w3.org%2F2002%2F07%2Fowl%23%3E+SELECT+%3Flocation+%3Fsensor+WHERE+%7B+++++%3Fsensor+rdf%3Atype%2Frdfs%3AsubClassOf%2A+s223%3ASensor+.+++++%3Fsensor+s223%3Aobserves+%3Fproperty+.+++++%3Fproperty+qudt%3AhasQuantityKind+quantitykind%3ATemperature+.+++++%3Fsensor+s223%3AhasObservationLocation+%3Flocation+%7D+&url=https://models.open223.info/ibal.ttl) |
+
+## Model Components
+| Parent Class | Class | Instances |
+|------------|-------|----------------|
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [TemperatureSensor](https://explore.open223.info/s223/TemperatureSensor.html) | 38 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Damper](https://explore.open223.info/s223/Damper.html) | 19 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [FlowSensor](https://explore.open223.info/s223/FlowSensor.html) | 12 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Controller](https://explore.open223.info/s223/Controller.html) | 9 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [HumiditySensor](https://explore.open223.info/s223/HumiditySensor.html) | 9 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [PressureSensor](https://explore.open223.info/s223/PressureSensor.html) | 8 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [HeatingCoil](https://explore.open223.info/s223/HeatingCoil.html) | 7 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [VariableFrequencyDrive](https://explore.open223.info/s223/VariableFrequencyDrive.html) | 5 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Fan](https://explore.open223.info/s223/Fan.html) | 5 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [ThreeWayValve](https://explore.open223.info/s223/ThreeWayValve.html) | 5 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [TwoWayValve](https://explore.open223.info/s223/TwoWayValve.html) | 5 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Pump](https://explore.open223.info/s223/Pump.html) | 4 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [TerminalUnit](https://explore.open223.info/s223/TerminalUnit.html) | 4 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [AirHandlingUnit](https://explore.open223.info/s223/AirHandlingUnit.html) | 3 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [CoolingCoil](https://explore.open223.info/s223/CoolingCoil.html) | 3 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Chiller](https://explore.open223.info/s223/Chiller.html) | 2 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [ElectricMeter](https://explore.open223.info/s223/ElectricMeter.html) | 2 |
+| [Equipment](https://explore.open223.info/s223/Equipment.html) | [HeatExchanger](https://explore.open223.info/s223/HeatExchanger.html) | 2 |
+| [Connection](https://explore.open223.info/s223/Connection.html) | [Pipe](https://explore.open223.info/s223/Pipe.html) | 1 |
+| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [InletConnectionPoint](https://explore.open223.info/s223/InletConnectionPoint.html) | 159 |
+| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [OutletConnectionPoint](https://explore.open223.info/s223/OutletConnectionPoint.html) | 137 |
+| [DomainSpace](https://explore.open223.info/s223/DomainSpace.html) | [](https://explore.open223.info/s223/.html) | 4 |
+| [Zone](https://explore.open223.info/s223/Zone.html) | [](https://explore.open223.info/s223/.html) | 6 |
+| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableObservableProperty](https://explore.open223.info/s223/QuantifiableObservableProperty.html) | 77 |
+| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableProperty](https://explore.open223.info/s223/QuantifiableProperty.html) | 6 |
+
diff --git a/models/G36-4-1.jsonld b/models/G36-4-1.jsonld
index fd158e0c..51df1413 100644
--- a/models/G36-4-1.jsonld
+++ b/models/G36-4-1.jsonld
@@ -21,29 +21,13 @@
]
},
{
- "@id": "urn:ex/damper-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/out",
+ "@id": "urn:ex/damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/out-connection"
+ "@id": "urn:ex/duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -51,74 +35,54 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/discharge-air-flow"
+ "@id": "urn:ex/out"
}
]
},
{
- "@id": "urn:ex/damper",
+ "@id": "urn:ex/in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/damper-in"
- },
- {
- "@id": "urn:ex/damper-out"
+ "@id": "urn:ex/in-connection"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/damper-out",
+ "@id": "urn:ex/in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/out"
- }
]
},
{
- "@id": "urn:ex/damper-command",
+ "@id": "urn:ex/",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Position"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://www.w3.org/2002/07/owl#Ontology"
+ ]
+ },
+ {
+ "@id": "urn:ex/duct-before-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
@@ -144,38 +108,18 @@
]
},
{
- "@id": "urn:ex/in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-cooling-only",
+ "@id": "urn:ex/discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAV"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
"@id": "urn:ex/out"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/damper"
+ "@id": "urn:ex/discharge-air-flow"
}
]
},
@@ -191,47 +135,83 @@
]
},
{
- "@id": "urn:ex/",
+ "@id": "urn:ex/damper-position",
"@type": [
- "http://www.w3.org/2002/07/owl#Ontology"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
]
},
{
- "@id": "urn:ex/discharge-air-flow-sensor",
+ "@id": "urn:ex/damper",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/out"
+ "@id": "urn:ex/damper-in"
+ },
+ {
+ "@id": "urn:ex/damper-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/discharge-air-flow"
+ "@id": "urn:ex/damper-command"
+ },
+ {
+ "@id": "urn:ex/damper-position"
}
]
},
{
- "@id": "urn:ex/in-connection",
+ "@id": "urn:ex/out",
"@type": [
- "http://data.ashrae.org/standard223#Connection"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/discharge-air-flow"
+ }
]
},
{
- "@id": "urn:ex/duct-before-damper",
+ "@id": "urn:ex/damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Position"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
@@ -251,6 +231,26 @@
}
]
},
+ {
+ "@id": "urn:ex/vav-cooling-only",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAV"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/in"
+ },
+ {
+ "@id": "urn:ex/out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/damper"
+ }
+ ]
+ },
{
"@id": "urn:ex/duct-after-damper",
"@type": [
diff --git a/models/guideline36-2021-4.2.jsonld b/models/guideline36-2021-4.2.jsonld
new file mode 100644
index 00000000..074365db
--- /dev/null
+++ b/models/guideline36-2021-4.2.jsonld
@@ -0,0 +1,589 @@
+[
+ {
+ "@id": "urn:ex/reheat-coil-valve-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/hot-water-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/discharge-air-flow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/hot-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/discharge-air-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/damper-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/air-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/air-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/air-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/air-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/reheat-coil-valve-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/discharge-air-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/discharge-air-flow"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/damper-in"
+ },
+ {
+ "@id": "urn:ex/damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/damper-command"
+ },
+ {
+ "@id": "urn:ex/damper-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/damper-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/air-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/hot-water-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-air-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/air-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/discharge-air-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/damper-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Position"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Position"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/air-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/damper-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/",
+ "@type": [
+ "http://www.w3.org/2002/07/owl#Ontology"
+ ]
+ },
+ {
+ "@id": "urn:ex/air-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/air-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-reheat",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/air-in"
+ },
+ {
+ "@id": "urn:ex/air-out"
+ },
+ {
+ "@id": "urn:ex/hot-water-in"
+ },
+ {
+ "@id": "urn:ex/hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/damper"
+ },
+ {
+ "@id": "urn:ex/reheat-coil"
+ },
+ {
+ "@id": "urn:ex/reheat-coil-valve"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/reheat-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ }
+]
\ No newline at end of file
diff --git a/models/ibal.jsonld b/models/ibal.jsonld
new file mode 100644
index 00000000..d34f67e5
--- /dev/null
+++ b/models/ibal.jsonld
@@ -0,0 +1,14772 @@
+[
+ {
+ "@id": "http://example.org/IBAL#Segment_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc3-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_Zone",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 Zone"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_27",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc27-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc27-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc27-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 27"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_45",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_15_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 45"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_74",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc27-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 74"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_105"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 1 ICP 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc2-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper-2-InletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper-2-Inlet flow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ ],
+ "http://data.ashrae.org/standard223#connected": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_10"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VFD_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_8",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_8_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_8_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 8"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_88_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "62"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment_88_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_18_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_18"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 18 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_out_rtd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 Out RTD"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_329",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d6_pos_fb"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 329"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_heat_power",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/W"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU1 Heat Power"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc35-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_11",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_27"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-1-InletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 11"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#ThreeWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_70",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc25-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 70"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_19",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc19-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 19"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc14-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#ThreeWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_67"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc24-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-3-Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "66"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "66"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 3 Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACSpace 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_VFD_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_1_S_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 1 to VFD 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-4-Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "68"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "68"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 4 Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_18_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_18"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 18 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Exhaust_Fan_1_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Damper_7_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Exhaust Fan 1 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_24",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc24-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 24"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_310AO",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d5_pos_c"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 310AO"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 4 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_18",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 18"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_13_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 13 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_3"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": " CC 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_62"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc23-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Fan"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Fan_4_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc35-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-5-OutletPressure",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11270"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "11270"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5 OutletPressure"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc18-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#ThreeWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_10",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 10"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc19-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 9"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_12"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-1-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_3_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_W_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heating coil 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-4-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "80"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "80"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 4 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_59",
+ "@type": [
+ "http://data.ashrae.org/standard223#ElectricMeter"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#VFD_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_fan_power"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 59"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc22-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_2_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#Junction_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc2-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#Fan"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Fan_5_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_329AO",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observers": [
+ {
+ "@id": "http://example.org/IBAL#d6_pos_c"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 329AO"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 5 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Pump"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatExchange_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heat Exchange Connection"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_12"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 4 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_16_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_16"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 16 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 2 Upper ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc37-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_99"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc37-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Class",
+ "http://www.w3.org/ns/shacl#NodeShape"
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temperature Sensor"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Sensor"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_450",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#VFD_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_vfd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 450"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_26",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_44"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-5-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 26"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_18",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-4-Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 18"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_t_ra",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "65"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 T RA"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_56"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 G ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_19",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_19_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_19_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 19"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_101"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc38-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#d5_pos_fb",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "d5 pos fb"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_16",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_3_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 16"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc9-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 9"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_14",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 14"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 G OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 1 Lower ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Damper-2-InletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_25",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-5-InletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 25"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_4_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_W_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heating coil 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_56",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 56"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_25",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc25-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc25-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc25-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 25"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc22-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc22-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_33",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_9_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 33"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 1 Upper ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc25-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc25-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Equipment"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_97",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc36-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 97"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc33-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#CC_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_31",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 31"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_30",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc30-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc30-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 30"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Enclosure_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_3"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Enclosure 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-2-InletPressure",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "21730"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "21730"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ExhaustFan 2 InletPressure"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_52"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc17-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 2 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc7-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_12_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 12 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc15-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 2 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-5-OutletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "20"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "20"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 5 OutletFlow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 2 Lower ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_61",
+ "@type": [
+ "http://data.ashrae.org/standard223#ElectricMeter"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_heat_power"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 61"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_p_up",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11296"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "11296"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU1 P Up"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_11",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 11"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc1-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Humidity_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_16"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-3-OutletHumidity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Humidity 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 1 Lower Connection"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Thermal Storage 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_100"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc38-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 5 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_cc_out_rtd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU1 CC Out RTD"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc16-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_Connection_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-1-InletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_88"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc32-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc7-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc31-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_G_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3 G ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc7-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_6_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_6_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatExchange_Connection_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "72"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HeatExchange_Connection_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_21",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_6_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 21"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_6_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_W_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@value": "IBAL:VAV4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heating coil 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_19",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-2-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 19"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_25",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_6_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 25"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-3-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "85"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "85"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 3 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_23",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc23-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 23"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Humidity_8",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_18"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-4-OutletHumidity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Humidity 8"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_36",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc36-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc36-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc36-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 36"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_Zone",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_4"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 Zone"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc34-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc34-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_77"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc28-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_94",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc34-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 94"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_68",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 68"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#ThreeWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_1_Water_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 1 Water ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_93"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc35-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_63",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 63"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc21-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 1 Lower OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_52",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#lnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 52"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VFD_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_vfd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 4 ICP 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_98",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc22-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc36-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 98"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc18-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_7_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_7_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_8_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 8 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-1-Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_86",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc27-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 86"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc4-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 2 Upper OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Fan"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Fan_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_S_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc1-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_21",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_27"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-1-InletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 21"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_93",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc34-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 93"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_12_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 12 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_97_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "60"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment_97_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_5_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_5"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 5 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 5 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_2_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_W_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heating coil 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACSpace 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc20-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc20-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 1 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_74",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_heat_rtd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 74"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VFD_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_48",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_17_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-OCP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 48"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatExchanger"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate heat exchanger 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc6-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_S_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 1 S ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc3-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc3-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_S_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_5_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc3-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-2-InletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ExhaustFan 2 Inlet Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc26-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_14",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc14-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 14"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_1_Bypass_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 1 Bypass Connection"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc13-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Exhaust_Fan_2_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Damper_9_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Exhaust Fan 2 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_VFD_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_4_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 4 VFD 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc32-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACZone_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACZone 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_20",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_12_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-OCP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 20"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_70"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_70_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Pressure_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-2-OutletPressure"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Pressure 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_325T",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_23"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_t_ra"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 325T"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_9"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_p_down"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_in_rtd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 In RTD"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_22",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc22-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 22"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VAV_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-5-OutletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_30",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 30"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper-1-InletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "500"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "500"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper-1-Inlet Flow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#VAV_1_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_67_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "64"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment_67_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_49",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_18_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 49"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc29-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_Connection_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Damper_4_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 4 Connection 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_11_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_35"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_11"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 11 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_24",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_8_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 24"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc36-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc36-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_76temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "75"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 76temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Humidity_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-2-OutletHumidity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Humidity 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_76",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_9"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_out_rtd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 76"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACZone_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_1"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACZone 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_92_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "67"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment_92_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc5-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Pressure_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_30"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-2-InletPressure"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Pressure 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-1-InletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "1000"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ExhaustFan 1 Inlet Flow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_39"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc12-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_rh_down",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "50"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "50"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 RH Down"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-4-OutletHumidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "30"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 4 OutletHumidity"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc26-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-5-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "45"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_1_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc34-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc34-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_23",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_52"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 23"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc3-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc3-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc3-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_14_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 14 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Pressure_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_27"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-1-InletPressure"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Pressure 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_15_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 15 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_11",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_11_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_11_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 11"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_326",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_38"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_f_sa"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 326"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-2-InletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "25"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ExhaustFan 2 Inlet Flow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_83",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 83"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_16",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_16"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-3-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 16"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-2-OutletHumidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "50"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 2 OutletHumidity"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_89"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Thermal Storage 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_14",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-5-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 14"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc24-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc13-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_69"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_69_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_92",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc34-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 92"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-5-InletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "60"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5 InletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-1-OutletHumidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "30"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 1 OutletHumidity"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HC_4_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_rh_up"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc15-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACZone_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_3"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACZone 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_43",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_15_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 43"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_9"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_rh_down"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#v12_pos_c",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "v12 pos c"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_18"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_10",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_10_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_10_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 10"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_62",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc21-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 62"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-1-InletPressure",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11297"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "11297"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 1 InletPressure"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc8-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_89",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc33-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 89"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc6-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_29",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_10_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 29"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_44_Humidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "80"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 44 Property"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-1-InletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "40"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "40"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 1 InletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_7_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_W_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heating coil 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_G_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3 G OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_6_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 6 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#Junction_33"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc33-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_5"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc19-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_13",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 13"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_90",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc33-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 90"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_10",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 10"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc14-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc9-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@value": "IBAL:VAV4_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_22",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_30"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-2-InletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 22"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#d6_pos_fb",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "d6 pos fb"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper-3-InletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "700"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "700"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper-3-Inlet Flow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_37",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_12_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 37"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_102"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc19-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc21-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#CoolingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#CC_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_Water_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_Water_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Cooling coil 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_70_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "68"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment_70_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc4-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_27"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc9-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_9_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_9"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 9 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_20",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc20-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc20-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 20"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_325",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_23"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_f_ra"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 325"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Damper-2-InletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_12",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_92"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_92_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 12"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_3_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACSpace 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_96",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc35-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 96"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_VFD_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_3_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 3 VFD 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_35",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 35"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_18",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc18-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 18"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc28-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-3-OutletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "500"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "500"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 3 OutletFlow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_12",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 12"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_35",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 35"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc17-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-5-OutletHumidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "50"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5 OutletHumidity"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-7-InletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 7 InletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_12",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_30"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-2-InletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 12"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#CoolingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#CC_1_Water_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_1_Water_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Cooling coil 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Fan_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3 Connection 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 7OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_46",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_16_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 46"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 5 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 7 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ReturnAir-1-Flow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "500"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "500"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Return Air 1 Flow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_2_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_15",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_15_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_15_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 15"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#CoolingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#CC_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_W_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_W_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Cooling coil 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_13",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 13"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc16-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Pump"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-2-Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 2 Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_Connection_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_41",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_13_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 41"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-2-Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 9"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_61"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc21-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#TwoWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_26",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_10_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 26"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VFD_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 1 Lower OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL",
+ "@type": [
+ "http://www.w3.org/2002/07/owl#Ontology"
+ ],
+ "http://www.w3.org/2002/07/owl#imports": [
+ {
+ "@id": "http://data.ashrae.org/standard223/1.0/model/all"
+ }
+ ],
+ "http://www.w3.org/2002/07/owl#versionInfo": [
+ {
+ "@value": "Created with TopBraid Composer"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 3 ICP 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 2 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_Water_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": " CC 2 Water OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_69_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "65"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment_69_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_8",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_76"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_76temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 8"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#v12_pos_fb",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "v12 pos fb"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_107"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc23-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc11-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_21",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc21-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 21"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 4 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 1 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc8-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterChiller_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Chiller"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Chiller 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_2_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_87"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 5 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-1-OutletHumidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "80"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "80"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 1 OutletHumidity"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 5 ICP 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc37-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc37-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_6_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 6 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_100",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc37-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 100"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_17",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 17"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_17_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_17"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_17"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 17 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_22",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc6-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 22"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_4"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_S_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_52"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 2 Lower OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_23",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_14_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 23"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_105",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 105"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_1_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_W_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heating coil 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc20-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc20-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-1-InletPressure",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "21720"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "21720"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ExhaustFan 1 Inlet Pressure"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_67",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc23-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 67"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_11",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_88"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_88_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 11"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-2-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "65"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "65"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 2 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc11-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Enclosure_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_1"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Enclosure 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_34",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc34-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc34-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc34-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 34"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": " CC 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_12",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_12_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_12_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 12"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc4-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc25-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc25-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 3 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 5 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_S_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 S ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#TwoWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_22"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc6-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_17_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 17 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 7 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 1 Upper ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_16"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_73",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HC_4_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_in_rtd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 73"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 G OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_VFD_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_2_S_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 2 VFD 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc28-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_10",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_Connection"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 10"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#TwoWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_14_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_14_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 14"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc5-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_19_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 19 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc1-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc10-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_42",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#lnx": [
+ {
+ "@id": "http://example.org/IBAL#HC_4_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 42"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_W_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 3 W OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_f_cc",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "40"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/GAL_US-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "40"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 197"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_13",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_97"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_97_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 13"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HC_5_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_W_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Heating coil 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_397",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_heat_c"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 397"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_39",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 39"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_42"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc14-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 5 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_37",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc37-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc37-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc37-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 37"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_101",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc18-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 101"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#TwoWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc32-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_7_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 7 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#Junction_15"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc17-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_Bypass_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 2 Bypass Connection"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HeatExchange_Connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HeatExchange_Connection_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Upper_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 2 Upper OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc27-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc27-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc13-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_f_ra",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "1000"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "1000"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 F RA"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 3 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_f_sa",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "600"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "600"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 F SA"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_95",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc35-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 95"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-1-InletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 1 InletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5_VFD_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_5_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 5 VFD 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_106"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 2 ICP 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_t_sa",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 T SA"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_4_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc30-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc30-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc31-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc34-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc34-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_33",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc33-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 33"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc12-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_Water_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 2 Water ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-1-InletHumidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 1 InletHumidity"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_28",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_8_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 28"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc8-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Upper_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 1 Upper OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_ICP_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 1 ICP 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_vfd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ahu1 vfd"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc24-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc24-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_6"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_4"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VAV_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_15",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc15-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 15"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-2-OutletPressure",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11254"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "11254"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 2 OutletPressure"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_124",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_105"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_cc_out_rtd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 124"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 6 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Fan"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Fan_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_S_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_59",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc21-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 59"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_76",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc26-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 76"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_79",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 79"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Pump"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper-4-InletFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "1000"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "1000"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper-4-Inlet Flow"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-2-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc17-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_85",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc31-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 85"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_3_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 3 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_16_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_16"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 16 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Humidity_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-1-OutletHumidity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Humidity 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_71",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc25-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 71"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Humidity_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HC_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-1-InletHumidity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Humidity 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-3-OutletHumidity",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "50"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 3 OutletHumidity"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc9-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_cc_rtd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "45"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 CC RTD"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_heat_rtd",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 Heat RTD"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_13_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_13_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 13"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_78",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 78"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-3-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "72"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "72"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 3 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_51",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_19_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 51"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc23-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc23-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#TwoWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_69",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc25-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 69"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 9"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_412",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#v12_pos_c"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 412"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#VAV_4_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#d6_pos_c",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "d6 pos c"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 3 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 4 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_87",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 87"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_44"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_42"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_103",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc19-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 103"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 5 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc5-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc5-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_7_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_7"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 7 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 1 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_106",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_G_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 106"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_77",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 77"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc36-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc36-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 5 ICP 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_heat_c",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU1 Heat C"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_32",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_7_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc11-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 32"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Pressure_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_Connection_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-1-InletPressure"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Pressure 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc7-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatExchanger"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate heat exchanger 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_40",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_14_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc14-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 40"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc37-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc37-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc22-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_2_Lower_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 2 Lower OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 2 ICP 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_104",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_5_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 104"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_10_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 10 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#ThreeWayValve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_ICP_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_9_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_9_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 9"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_p_down",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11297"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "11297"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 P Down"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_29",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc29-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 29"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_28",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc28-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc28-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 28"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc2-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 4 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc16-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_12",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc12-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 12"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Pressure_8",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_44"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-5-OutletPressure"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Pressure 8"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_64",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc22-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 64"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_8_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 8 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#CC_2_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_14_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 14 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_15_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_15"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 15 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc10-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 2 Lower ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_32",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc32-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 32"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_10_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 10 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_20",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_18"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-4-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 20"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_19",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc5-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc7-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 19"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_19_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 19 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_38",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_13_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 38"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_Connection_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#CC_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 Connection 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_76"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc26-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_99",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc36-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc37-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 99"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc25-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_71"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc25-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_395bw",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_on"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 395bw"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc6-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc6-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_S_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 S ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VAV_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 3 ICP 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 5 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Humidity_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_44"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_44_Humidity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Humidity 9"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_8",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#VAV_2_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-3-OutletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 8"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc4-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_13_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 13 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_7_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_7"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 7 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc18-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_5_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Humidity_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#HumiditySensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_12"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-1-OutletHumidity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Humidity 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_75",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 75"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-1-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "80"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "80"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 1 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#VAV_3_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 3 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HC_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-1-InletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection_Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "PlateHeatExchange_1_Connection_Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3 Connection 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_16",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_16_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_16_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 16"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD-5-InletPressure",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "11297"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PA"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "11297"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 5 InletPressure"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_36",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc13-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 36"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_88",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc32-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 88"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc2-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_5_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_5"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 5 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Pump"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_on",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Voltage"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ahu1 on"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 4 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_50",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_18_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc17-ICP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 50"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_6",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#VAV_2_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-3-OutletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 6"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_11_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_39"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 11 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_47",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Damper_16_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 47"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_fan_power",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/W"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU1 Fan Power"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-2-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 2 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_1_Lower_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 1 Lower ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHetExchange_1_Bypass_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_3_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 1 Bypass Connection"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_383",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#v12_pos_fb"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 383"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Fan"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Fan_3_E_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc27-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc27-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_73",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc27-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 73"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_24",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HC-7-InletTemp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 24"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_27",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Fan_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc9-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 27"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_16",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc16-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc16-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 16"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACZone_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_4"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACZone 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-1-Temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "66"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "66"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 1 Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_7"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Damper-3-InletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc10-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc10-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 6 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": " CC 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_2_S_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Electricity-Signal"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Fan 2 S ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_61",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc20-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc21-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 61"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_5_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Manual two way valve 5 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#d5_pos_c",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositionVector"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "d5 pos c"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc15-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc15-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_17",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_17_ICP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 17"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_82",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc30-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 82"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_1_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "CC 1 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterChiller_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Chiller"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Chiller 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_Connection_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#CC_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 Connection 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC-5-OutletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "70"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "70"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 5 OutletTemp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_ICP_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Lower_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 1 Connection"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_9",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_20"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ReturnAir-1-Flow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 9"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#VariableFrequencyDrive"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#VFD_1_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_1_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_fan_power"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_326T",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_38"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_t_sa"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 326T"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Upper_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 2 Upper ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc3-ICP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc3-ICP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 G ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Hydronic",
+ "@type": [
+ "http://data.ashrae.org/standard223#System"
+ ],
+ "http://data.ashrae.org/standard223#hasMember": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchanger_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ThermalStorage_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterChiller_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterChiller_2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_26",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc26-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 26"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_38",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc38-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc38-OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 38"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_1_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 1 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Temp_15",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace-3-Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Temp 15"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#CC_1_Water_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1_G_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": " CC 1 Water OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatExchange",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "60"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HeatExchange"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Enclosure_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_4"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Enclosure 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1_Connection_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Damper_1_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_2_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 1 Connection 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "http://example.org/IBAL#VAV_4_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 6 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3_Connection_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Damper_3_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_5_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 3 Connection 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_9_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_9"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Damper 9 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVAC Space 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Enclosure_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_2"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Enclosure 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_18",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_18_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_18_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 18"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc33-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc31-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_Connection_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_p_up"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HVACSpace_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HVAC_Space_4_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HVACSpace 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_5",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#Damper_5_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Damper_5_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized damper 5"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_8",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc3-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc4-OCP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 8"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_6_E_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 6 E ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc1-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc1-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_60",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc20-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_2_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 60"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_Upper_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate Heat Exchange 1 Upper OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_107",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc23-ICP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_3_OCP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 107"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_102",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc19-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc37-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 102"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#PlateHeatExchange_1_ConnectionTemperature",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Plate heat exchange 1 Connection temperature"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_84",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc30-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc31-ICP1"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 84"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4_ICP_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#isConnectionPointOf": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedThreeWayValve_4"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Motorized three way valve 4 ICP 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_197",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_105"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_f_cc"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 197"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc33-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc33-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_W_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "HC 3 W ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_2",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc2-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc2-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc29-ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc29-ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_75",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_2_Connection_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#ahu1_cc_rtd"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 75"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Pressure_7",
+ "@type": [
+ "http://data.ashrae.org/standard223#PressureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_Connection_3"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#VFD-5-InletPressure"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Pressure 7"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ahu1_rh_up",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "60"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://qudt.org/schema/qudt/value": [
+ {
+ "@value": "60"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 1 RH Up"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc30-OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_84"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc30-OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#ExhaustFan-1-InletTemp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasValue": [
+ {
+ "@type": "http://www.w3.org/2001/XMLSchema#decimal",
+ "@value": "1000"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_F"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "ExhaustFan 1 Inlet Temp"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3",
+ "@type": [
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "http://example.org/IBAL#CoolingCoil_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_5"
+ },
+ {
+ "@id": "http://example.org/IBAL#HeatingCoil_7"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "http://example.org/IBAL#AHU_3_G_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_G_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_3_OCP"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 3"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterTempSensor_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#TemperatureSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_67"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Segment_67_Temp"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water Temp Sensor 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_44",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc15-ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 44"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc36-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Segment_98"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc36-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "AHU 2 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc3-ICP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc3-ICP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_Connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Chiller_2_Lower_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Chiller 2 Lower Connection"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Flow_4",
+ "@type": [
+ "http://data.ashrae.org/standard223#FlowSensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#Segment_10"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#Damper-4-InletFlow"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Flow 4"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3_OCP",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Electricity"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VFD 3 OCP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Segment_57",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc18-OCP2"
+ },
+ {
+ "@id": "http://example.org/IBAL#ManualTwoWayValve_1_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Segment 57"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc12-OCP1",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc12-OCP1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2_Connection_1",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection"
+ ],
+ "http://data.ashrae.org/standard223#connectsAt": [
+ {
+ "@id": "http://example.org/IBAL#Damper_2_OCP"
+ },
+ {
+ "@id": "http://example.org/IBAL#HC_3_ICP"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "VAV 2 Connection 1"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#WaterPump_2_ICP",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Water pump 2 ICP"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Junction_8",
+ "@type": [
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "http://example.org/IBAL#Jnc8-ICP"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP1"
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc8-OCP2"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Junction 8"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Jnc27-OCP2",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-GlycolSolution"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Jnc27-OCP2"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#Channel_310",
+ "@type": [
+ "http://data.ashrae.org/standard223#Controller"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "http://example.org/IBAL#d5_pos_fb"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "Channel 310"
+ }
+ ]
+ },
+ {
+ "@id": "http://example.org/IBAL#AirFlow",
+ "@type": [
+ "http://data.ashrae.org/standard223#System"
+ ],
+ "http://data.ashrae.org/standard223#hasMember": [
+ {
+ "@id": "http://example.org/IBAL#AHU_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#AHU_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#Fan_4"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_10"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_11"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_12"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_13"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_14"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_15"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_16"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_17"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_18"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_19"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_5"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_6"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_7"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_8"
+ },
+ {
+ "@id": "http://example.org/IBAL#MotorizedDamper_9"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_1"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_2"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#VAV_4"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_3"
+ },
+ {
+ "@id": "http://example.org/IBAL#VFD_4"
+ }
+ ]
+ }
+]
\ No newline at end of file
diff --git a/models/ibal.ttl b/models/ibal.ttl
new file mode 100644
index 00000000..fca03e1a
--- /dev/null
+++ b/models/ibal.ttl
@@ -0,0 +1,4340 @@
+# baseURI: http://example.org/IBAL
+# imports: http://data.ashrae.org/standard223/1.0/model/all
+# prefix: IBAL
+
+@prefix IBAL: .
+@prefix brick: .
+@prefix owl: .
+@prefix qudt: .
+@prefix rdf: .
+@prefix rdfs: .
+@prefix s223: .
+@prefix sh: .
+@prefix xsd: .
+
+
+ a owl:Ontology ;
+ owl:imports ;
+ owl:versionInfo "Created with TopBraid Composer" ;
+.
+IBAL:AHU_1
+ a s223:AirHandlingUnit ;
+ s223:contains IBAL:CoolingCoil_1 ;
+ s223:contains IBAL:Fan_1 ;
+ s223:contains IBAL:HeatingCoil_1 ;
+ s223:contains IBAL:VFD_1 ;
+ s223:hasConnectionPoint IBAL:AHU_1_G_ICP ;
+ s223:hasConnectionPoint IBAL:AHU_1_G_OCP ;
+ s223:hasConnectionPoint IBAL:AHU_1_ICP ;
+ s223:hasConnectionPoint IBAL:AHU_1_OCP ;
+ s223:hasConnectionPoint IBAL:AHU_1_S_ICP ;
+ rdfs:label "AHU 1" ;
+.
+IBAL:AHU_1_Connection_2
+ a s223:Connection ;
+ s223:connectsAt IBAL:CC_1_ICP ;
+ s223:connectsAt IBAL:HC_1_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 1 Connection 2" ;
+.
+IBAL:AHU_1_Connection_3
+ a s223:Connection ;
+ s223:connectsAt IBAL:CC_1_OCP ;
+ s223:connectsAt IBAL:Fan_1_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 1 Connection 3" ;
+.
+IBAL:AHU_1_G_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "AHU 1 G ICP" ;
+.
+IBAL:AHU_1_G_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "AHU 1 G OCP" ;
+.
+IBAL:AHU_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 1 ICP" ;
+.
+IBAL:AHU_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 1 OCP" ;
+.
+IBAL:AHU_1_S_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Electricity-Signal ;
+ rdfs:label "AHU 1 S ICP" ;
+.
+IBAL:AHU_1_Zone
+ a s223:Zone ;
+ s223:hasDomain s223:Domain-HVAC ;
+ s223:hasDomainSpace IBAL:HVACSpace_1 ;
+ s223:hasDomainSpace IBAL:HVACSpace_2 ;
+ rdfs:label "AHU 1 Zone" ;
+.
+IBAL:AHU_2
+ a s223:AirHandlingUnit ;
+ s223:contains IBAL:CoolingCoil_2 ;
+ s223:contains IBAL:Fan_2 ;
+ s223:contains IBAL:HeatingCoil_4 ;
+ s223:contains IBAL:VFD_2 ;
+ s223:hasConnectionPoint IBAL:AHU_2_G_ICP ;
+ s223:hasConnectionPoint IBAL:AHU_2_G_OCP ;
+ s223:hasConnectionPoint IBAL:AHU_2_ICP ;
+ s223:hasConnectionPoint IBAL:AHU_2_OCP ;
+ s223:hasConnectionPoint IBAL:AHU_2_S_ICP ;
+ rdfs:label "AHU 2" ;
+.
+IBAL:AHU_2_Connection_2
+ a s223:Connection ;
+ s223:connectsAt IBAL:CC_2_ICP ;
+ s223:connectsAt IBAL:HC_4_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 2 Connection 2" ;
+.
+IBAL:AHU_2_Connection_3
+ a s223:Connection ;
+ s223:connectsAt IBAL:CC_2_OCP ;
+ s223:connectsAt IBAL:Fan_2_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 2 Connection 3" ;
+.
+IBAL:AHU_2_G_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_56 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "AHU 2 G ICP" ;
+.
+IBAL:AHU_2_G_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "AHU 2 G OCP" ;
+.
+IBAL:AHU_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_42 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 2 ICP" ;
+.
+IBAL:AHU_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 2 OCP" ;
+.
+IBAL:AHU_2_S_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Electricity-Signal ;
+ rdfs:label "AHU 2 S ICP" ;
+.
+IBAL:AHU_2_Zone
+ a s223:Zone ;
+ s223:hasDomain s223:Domain-HVAC ;
+ s223:hasDomainSpace IBAL:HVACSpace_3 ;
+ s223:hasDomainSpace IBAL:HVACSpace_4 ;
+ rdfs:label "AHU 2 Zone" ;
+.
+IBAL:AHU_3
+ a s223:AirHandlingUnit ;
+ s223:contains IBAL:CoolingCoil_3 ;
+ s223:contains IBAL:Fan_5 ;
+ s223:contains IBAL:HeatingCoil_7 ;
+ s223:hasConnectionPoint IBAL:AHU_3_G_ICP ;
+ s223:hasConnectionPoint IBAL:AHU_3_G_OCP ;
+ s223:hasConnectionPoint IBAL:AHU_3_ICP ;
+ s223:hasConnectionPoint IBAL:AHU_3_OCP ;
+ rdfs:label "AHU 3" ;
+.
+IBAL:AHU_3_Connection_2
+ a s223:Connection ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 3 Connection 2" ;
+.
+IBAL:AHU_3_Connection_3
+ a s223:Connection ;
+ s223:connectsAt IBAL:Fan_5_ICP ;
+ s223:connectsAt IBAL:HC_7_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 3 Connection 3" ;
+.
+IBAL:AHU_3_G_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "AHU 3 G ICP" ;
+.
+IBAL:AHU_3_G_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "AHU 3 G OCP" ;
+.
+IBAL:AHU_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_52 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 3 ICP" ;
+.
+IBAL:AHU_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_44 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "AHU 3 OCP" ;
+.
+IBAL:AirFlow
+ a s223:System ;
+ s223:hasMember IBAL:AHU_1 ;
+ s223:hasMember IBAL:AHU_2 ;
+ s223:hasMember IBAL:Fan_3 ;
+ s223:hasMember IBAL:Fan_4 ;
+ s223:hasMember IBAL:MotorizedDamper_10 ;
+ s223:hasMember IBAL:MotorizedDamper_11 ;
+ s223:hasMember IBAL:MotorizedDamper_12 ;
+ s223:hasMember IBAL:MotorizedDamper_13 ;
+ s223:hasMember IBAL:MotorizedDamper_14 ;
+ s223:hasMember IBAL:MotorizedDamper_15 ;
+ s223:hasMember IBAL:MotorizedDamper_16 ;
+ s223:hasMember IBAL:MotorizedDamper_17 ;
+ s223:hasMember IBAL:MotorizedDamper_18 ;
+ s223:hasMember IBAL:MotorizedDamper_19 ;
+ s223:hasMember IBAL:MotorizedDamper_5 ;
+ s223:hasMember IBAL:MotorizedDamper_6 ;
+ s223:hasMember IBAL:MotorizedDamper_7 ;
+ s223:hasMember IBAL:MotorizedDamper_8 ;
+ s223:hasMember IBAL:MotorizedDamper_9 ;
+ s223:hasMember IBAL:VAV_1 ;
+ s223:hasMember IBAL:VAV_2 ;
+ s223:hasMember IBAL:VAV_3 ;
+ s223:hasMember IBAL:VAV_4 ;
+ s223:hasMember IBAL:VFD_3 ;
+ s223:hasMember IBAL:VFD_4 ;
+.
+IBAL:CC_1_Bypass_Connection
+ a s223:Connection ;
+ s223:connectsAt IBAL:ManualTwoWayValve_2_OCP ;
+ s223:connectsAt IBAL:MotorizedThreeWayValve_1_ICP_2 ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "CC 1 Bypass Connection" ;
+.
+IBAL:CC_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:CoolingCoil_1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "CC 1 ICP" ;
+.
+IBAL:CC_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:CoolingCoil_1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label " CC 1 OCP" ;
+.
+IBAL:CC_1_Water_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:mapsTo IBAL:AHU_1_G_ICP ;
+ rdfs:label "CC 1 Water ICP" ;
+.
+IBAL:CC_1_Water_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:mapsTo IBAL:AHU_1_G_OCP ;
+ rdfs:label " CC 1 Water OCP" ;
+.
+IBAL:CC_2_Bypass_Connection
+ a s223:Connection ;
+ s223:connectsAt IBAL:ManualTwoWayValve_1_OCP ;
+ s223:connectsAt IBAL:MotorizedThreeWayValve_2_ICP_2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "CC 2 Bypass Connection" ;
+.
+IBAL:CC_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:CoolingCoil_2 ;
+ rdfs:label "CC 2 ICP" ;
+.
+IBAL:CC_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:CoolingCoil_2 ;
+ rdfs:label " CC 2 OCP" ;
+.
+IBAL:CC_2_Water_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:mapsTo IBAL:AHU_2_G_ICP ;
+ rdfs:label "CC 2 Water ICP" ;
+.
+IBAL:CC_2_Water_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ s223:mapsTo IBAL:AHU_2_G_OCP ;
+ rdfs:label " CC 2 Water OCP" ;
+.
+IBAL:CC_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:AHU_3_ICP ;
+ rdfs:label "CC 3 ICP" ;
+.
+IBAL:CC_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:AHU_3_Connection_2 ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:CoolingCoil_3 ;
+ rdfs:label " CC 3 OCP" ;
+.
+IBAL:CC_3_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "CC 3 W ICP" ;
+.
+IBAL:CC_3_W_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "CC 3 W OCP" ;
+.
+IBAL:Channel_124
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_105 ;
+ s223:observes IBAL:ahu1_cc_out_rtd ;
+ rdfs:label "Channel 124" ;
+.
+IBAL:Channel_197
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_105 ;
+ s223:observes IBAL:ahu1_f_cc ;
+ rdfs:label "Channel 197" ;
+.
+IBAL:Channel_3
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:HC_4_ICP ;
+ s223:observes IBAL:ahu1_rh_up ;
+ rdfs:label "Channel 3" ;
+.
+IBAL:Channel_310
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:MotorizedDamper_14 ;
+ s223:observes IBAL:d5_pos_fb ;
+ rdfs:label "Channel 310" ;
+.
+IBAL:Channel_310AO
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:MotorizedDamper_14 ;
+ s223:observes IBAL:d5_pos_c ;
+ rdfs:label "Channel 310AO" ;
+.
+IBAL:Channel_325
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_23 ;
+ s223:observes IBAL:ahu1_f_ra ;
+ rdfs:label "Channel 325" ;
+.
+IBAL:Channel_325T
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_23 ;
+ s223:observes IBAL:ahu1_t_ra ;
+ rdfs:label "Channel 325T" ;
+.
+IBAL:Channel_326
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_38 ;
+ s223:observes IBAL:ahu1_f_sa ;
+ rdfs:label "Channel 326" ;
+.
+IBAL:Channel_326T
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_38 ;
+ s223:observes IBAL:ahu1_t_sa ;
+ rdfs:label "Channel 326T" ;
+.
+IBAL:Channel_329
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:MotorizedDamper_13 ;
+ s223:observes IBAL:d6_pos_fb ;
+ rdfs:label "Channel 329" ;
+.
+IBAL:Channel_329AO
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:MotorizedDamper_13 ;
+ s223:observers IBAL:d6_pos_c ;
+ rdfs:label "Channel 329AO" ;
+.
+IBAL:Channel_383
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:MotorizedThreeWayValve_1 ;
+ s223:observes IBAL:v12_pos_fb ;
+ rdfs:label "Channel 383" ;
+.
+IBAL:Channel_395bw
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:AHU_3 ;
+ s223:observes IBAL:ahu1_on ;
+ rdfs:label "Channel 395bw" ;
+.
+IBAL:Channel_397
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:HeatingCoil_4 ;
+ s223:observes IBAL:ahu1_heat_c ;
+ rdfs:label "Channel 397" ;
+.
+IBAL:Channel_4
+ a s223:PressureSensor ;
+ s223:hasObservationLocation IBAL:AHU_2_Connection_3 ;
+ s223:observes IBAL:ahu1_p_up ;
+ rdfs:label "Channel 4" ;
+.
+IBAL:Channel_412
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:MotorizedThreeWayValve_1 ;
+ s223:observes IBAL:v12_pos_c ;
+ rdfs:label "Channel 412" ;
+.
+IBAL:Channel_450
+ a s223:Controller ;
+ s223:hasObservationLocation IBAL:VFD_2 ;
+ s223:observes IBAL:ahu1_vfd ;
+ rdfs:label "Channel 450" ;
+.
+IBAL:Channel_5
+ a s223:PressureSensor ;
+ s223:hasObservationLocation IBAL:Segment_9 ;
+ s223:observes IBAL:ahu1_p_down ;
+ rdfs:label "Channel 5" ;
+.
+IBAL:Channel_59
+ a s223:ElectricMeter ;
+ s223:hasObservationLocation IBAL:VFD_2 ;
+ s223:observes IBAL:ahu1_fan_power ;
+ rdfs:label "Channel 59" ;
+.
+IBAL:Channel_6
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:Segment_9 ;
+ s223:observes IBAL:ahu1_rh_down ;
+ rdfs:label "Channel 6" ;
+.
+IBAL:Channel_61
+ a s223:ElectricMeter ;
+ s223:hasObservationLocation IBAL:HeatingCoil_4 ;
+ s223:observes IBAL:ahu1_heat_power ;
+ rdfs:label "Channel 61" ;
+.
+IBAL:Channel_73
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:HC_4_ICP ;
+ s223:observes IBAL:ahu1_in_rtd ;
+ rdfs:label "Channel 73" ;
+.
+IBAL:Channel_74
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:AHU_2_Connection_2 ;
+ s223:observes IBAL:ahu1_heat_rtd ;
+ rdfs:label "Channel 74" ;
+.
+IBAL:Channel_75
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:AHU_2_Connection_3 ;
+ s223:observes IBAL:ahu1_cc_rtd ;
+ rdfs:label "Channel 75" ;
+.
+IBAL:Channel_76
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_9 ;
+ s223:observes IBAL:ahu1_out_rtd ;
+ rdfs:label "Channel 76" ;
+.
+IBAL:Chiller_1_Lower_Connection
+ a s223:Connection ;
+ s223:connectsAt IBAL:Chiller_1_Lower_OCP ;
+ s223:connectsAt IBAL:WaterPump_2_ICP ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Chiller 1 Lower Connection" ;
+.
+IBAL:Chiller_1_Lower_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Chiller 1 Lower ICP" ;
+.
+IBAL:Chiller_1_Lower_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Chiller 1 Lower OCP" ;
+.
+IBAL:Chiller_1_Upper_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Chiller 1 Upper ICP" ;
+.
+IBAL:Chiller_1_Upper_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Chiller 1 Upper OCP" ;
+.
+IBAL:Chiller_2_Lower_Connection
+ a s223:Connection ;
+ s223:connectsAt IBAL:Chiller_2_Lower_OCP ;
+ s223:connectsAt IBAL:WaterPump_3_ICP ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Chiller 2 Lower Connection" ;
+.
+IBAL:Chiller_2_Lower_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Chiller 2 Lower ICP" ;
+.
+IBAL:Chiller_2_Lower_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Chiller 2 Lower OCP" ;
+.
+IBAL:Chiller_2_Upper_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Chiller 2 Upper ICP" ;
+.
+IBAL:Chiller_2_Upper_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Chiller 2 Upper OCP" ;
+.
+IBAL:CoolingCoil_1
+ a s223:CoolingCoil ;
+ s223:hasConnectionPoint IBAL:CC_1_Water_ICP ;
+ s223:hasConnectionPoint IBAL:CC_1_Water_OCP ;
+ s223:hasRole s223:Role-Cooling ;
+ rdfs:label "Cooling coil 1" ;
+.
+IBAL:CoolingCoil_2
+ a s223:CoolingCoil ;
+ s223:hasConnectionPoint IBAL:CC_2_ICP ;
+ s223:hasConnectionPoint IBAL:CC_2_OCP ;
+ s223:hasConnectionPoint IBAL:CC_2_Water_ICP ;
+ s223:hasConnectionPoint IBAL:CC_2_Water_OCP ;
+ rdfs:label "Cooling coil 2" ;
+.
+IBAL:CoolingCoil_3
+ a s223:CoolingCoil ;
+ s223:hasConnectionPoint IBAL:CC_3_ICP ;
+ s223:hasConnectionPoint IBAL:CC_3_OCP ;
+ s223:hasConnectionPoint IBAL:CC_3_W_ICP ;
+ s223:hasConnectionPoint IBAL:CC_3_W_OCP ;
+ rdfs:label "Cooling coil 3" ;
+.
+IBAL:Damper-1-InletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "500"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "500" ;
+ rdfs:label "Damper-1-Inlet Flow" ;
+.
+IBAL:Damper-2-InletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "45"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "Damper-2-Inlet flow" ;
+.
+IBAL:Damper-3-InletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "700"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "700" ;
+ rdfs:label "Damper-3-Inlet Flow" ;
+.
+IBAL:Damper-4-InletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "1000"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "1000" ;
+ rdfs:label "Damper-4-Inlet Flow" ;
+.
+IBAL:Damper_10_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 10 ICP" ;
+.
+IBAL:Damper_10_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 10 OCP" ;
+.
+IBAL:Damper_11_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_39 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 11 ICP" ;
+.
+IBAL:Damper_11_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_35 ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_11 ;
+ rdfs:label "Damper 11 OCP" ;
+.
+IBAL:Damper_12_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_12 ;
+ rdfs:label "Damper 12 ICP" ;
+.
+IBAL:Damper_12_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_12 ;
+ rdfs:label "Damper 12 OCP" ;
+.
+IBAL:Damper_13_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_13 ;
+ rdfs:label "Damper 13 ICP" ;
+.
+IBAL:Damper_13_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_13 ;
+ rdfs:label "Damper 13 OCP" ;
+.
+IBAL:Damper_14_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_14 ;
+ rdfs:label "Damper 14 ICP" ;
+.
+IBAL:Damper_14_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_14 ;
+ rdfs:label "Damper 14 OCP" ;
+.
+IBAL:Damper_15_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 15 ICP" ;
+.
+IBAL:Damper_15_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_15 ;
+ rdfs:label "Damper 15 OCP" ;
+.
+IBAL:Damper_16_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_16 ;
+ rdfs:label "Damper 16 ICP" ;
+.
+IBAL:Damper_16_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_16 ;
+ rdfs:label "Damper 16 OCP" ;
+.
+IBAL:Damper_17_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 17 ICP" ;
+.
+IBAL:Damper_17_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:MotorizedDamper_17 ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_17 ;
+ rdfs:label "Damper 17 OCP" ;
+.
+IBAL:Damper_18_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_18 ;
+ rdfs:label "Damper 18 ICP" ;
+.
+IBAL:Damper_18_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_18 ;
+ rdfs:label "Damper 18 OCP" ;
+.
+IBAL:Damper_19_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:MotorizedDamper_19 ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_19 ;
+ rdfs:label "Damper 19 ICP" ;
+.
+IBAL:Damper_19_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_19 ;
+ rdfs:label "Damper 19 OCP" ;
+.
+IBAL:Damper_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_1_ICP ;
+ rdfs:label "Damper 1 ICP" ;
+.
+IBAL:Damper_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 1 OCP" ;
+.
+IBAL:Damper_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_2_ICP ;
+ rdfs:label "Damper 2 ICP" ;
+.
+IBAL:Damper_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 2 OCP" ;
+.
+IBAL:Damper_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_3_ICP ;
+ rdfs:label "Damper 3 ICP" ;
+.
+IBAL:Damper_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 3 OCP" ;
+.
+IBAL:Damper_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_4_ICP ;
+ rdfs:label "Damper 4 ICP" ;
+.
+IBAL:Damper_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Damper 4 OCP" ;
+.
+IBAL:Damper_5_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_5 ;
+ rdfs:label "Damper 5 ICP" ;
+.
+IBAL:Damper_5_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_5 ;
+ rdfs:label "Damper 5 OCP" ;
+.
+IBAL:Damper_6_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_6 ;
+ rdfs:label "Damper 6 ICP" ;
+.
+IBAL:Damper_6_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Fan_3_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_6 ;
+ rdfs:label "Damper 6 OCP" ;
+.
+IBAL:Damper_7_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_7 ;
+ rdfs:label "Damper 7 ICP" ;
+.
+IBAL:Damper_7_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_7 ;
+ rdfs:label "Damper 7 OCP" ;
+.
+IBAL:Damper_8_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_8 ;
+ rdfs:label "Damper 8 ICP" ;
+.
+IBAL:Damper_8_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_8 ;
+ rdfs:label "Damper 8 OCP" ;
+.
+IBAL:Damper_9_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_9 ;
+ rdfs:label "Damper 9 ICP" ;
+.
+IBAL:Damper_9_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:MotorizedDamper_9 ;
+ rdfs:label "Damper 9 OCP" ;
+.
+IBAL:Enclosure_1
+ a s223:PhysicalSpace ;
+ s223:encloses IBAL:HVACSpace_1 ;
+ rdfs:label "Enclosure 1" ;
+.
+IBAL:Enclosure_2
+ a s223:PhysicalSpace ;
+ s223:encloses IBAL:HVACSpace_2 ;
+ rdfs:label "Enclosure 2" ;
+.
+IBAL:Enclosure_3
+ a s223:PhysicalSpace ;
+ s223:encloses IBAL:HVACSpace_3 ;
+ rdfs:label "Enclosure 3" ;
+.
+IBAL:Enclosure_4
+ a s223:PhysicalSpace ;
+ s223:encloses IBAL:HVACSpace_4 ;
+ rdfs:label "Enclosure 4" ;
+.
+IBAL:ExhaustFan-1-InletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "1000"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "ExhaustFan 1 Inlet Flow" ;
+.
+IBAL:ExhaustFan-1-InletPressure
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "21720"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "21720" ;
+ rdfs:label "ExhaustFan 1 Inlet Pressure" ;
+.
+IBAL:ExhaustFan-1-InletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "1000"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "ExhaustFan 1 Inlet Temp" ;
+.
+IBAL:ExhaustFan-2-InletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "25"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "ExhaustFan 2 Inlet Flow" ;
+.
+IBAL:ExhaustFan-2-InletPressure
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "21730"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "21730" ;
+ rdfs:label "ExhaustFan 2 InletPressure" ;
+.
+IBAL:ExhaustFan-2-InletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "70"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "70" ;
+ rdfs:label "ExhaustFan 2 Inlet Temp" ;
+.
+IBAL:Exhaust_Fan_1_Connection_2
+ a s223:Connection ;
+ s223:connectsAt IBAL:Damper_7_ICP ;
+ s223:connectsAt IBAL:Fan_3_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Exhaust Fan 1 Connection 2" ;
+.
+IBAL:Exhaust_Fan_2_Connection_2
+ a s223:Connection ;
+ s223:connectsAt IBAL:Damper_9_ICP ;
+ s223:connectsAt IBAL:Fan_4_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Exhaust Fan 2 Connection 2" ;
+.
+IBAL:Fan_1
+ a s223:Fan ;
+ s223:hasConnectionPoint IBAL:Fan_1_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_1_OCP ;
+ s223:hasConnectionPoint IBAL:Fan_1_S_ICP ;
+ rdfs:label "Fan 1" ;
+.
+IBAL:Fan_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Fan 1 ICP" ;
+.
+IBAL:Fan_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:AHU_1_OCP ;
+ rdfs:label "Fan 1 OCP" ;
+.
+IBAL:Fan_1_S_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Electricity-Signal ;
+ rdfs:label "Fan 1 S ICP" ;
+.
+IBAL:Fan_1_VFD_1
+ a s223:Connection ;
+ s223:cnx IBAL:Fan_1_S_ICP ;
+ s223:cnx IBAL:VFD_1_OCP ;
+ s223:hasMedium s223:Electricity-Signal ;
+ rdfs:label "Fan 1 to VFD 1" ;
+.
+IBAL:Fan_2
+ a s223:Fan ;
+ s223:hasConnectionPoint IBAL:Fan_2_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_2_OCP ;
+ s223:hasConnectionPoint IBAL:Fan_2_S_ICP ;
+ rdfs:label "Fan 2" ;
+.
+IBAL:Fan_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Fan 2 ICP" ;
+.
+IBAL:Fan_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:AHU_2_OCP ;
+ rdfs:label "Fan 2 OCP" ;
+.
+IBAL:Fan_2_S_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Electricity-Signal ;
+ rdfs:label "Fan 2 S ICP" ;
+.
+IBAL:Fan_2_VFD_2
+ a s223:Connection ;
+ s223:cnx IBAL:Fan_2_S_ICP ;
+ s223:cnx IBAL:VFD_2_OCP ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "Fan 2 VFD 2" ;
+.
+IBAL:Fan_3
+ a s223:Fan ;
+ s223:hasConnectionPoint IBAL:Fan_3_E_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_3_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_3_OCP ;
+ rdfs:label "Fan 3" ;
+.
+IBAL:Fan_3_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "Fan 3 E ICP" ;
+.
+IBAL:Fan_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Fan 3 ICP" ;
+.
+IBAL:Fan_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Fan 3 OCP" ;
+.
+IBAL:Fan_3_VFD_3
+ a s223:Connection ;
+ s223:cnx IBAL:Fan_3_E_ICP ;
+ s223:cnx IBAL:VFD_3_OCP ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "Fan 3 VFD 3" ;
+.
+IBAL:Fan_4
+ a s223:Fan ;
+ s223:hasConnectionPoint IBAL:Fan_4_E_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_4_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_4_OCP ;
+ rdfs:label "Fan 4" ;
+.
+IBAL:Fan_4_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "Fan 4 E ICP" ;
+.
+IBAL:Fan_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Fan 4 ICP" ;
+.
+IBAL:Fan_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Fan 4 OCP" ;
+.
+IBAL:Fan_4_VFD_4
+ a s223:Connection ;
+ s223:cnx IBAL:Fan_4_E_ICP ;
+ s223:cnx IBAL:VFD_4_OCP ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "Fan 4 VFD 4" ;
+.
+IBAL:Fan_5
+ a s223:Fan ;
+ s223:hasConnectionPoint IBAL:Fan_5_E_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_5_ICP ;
+ s223:hasConnectionPoint IBAL:Fan_5_OCP ;
+ rdfs:label "Fan 5" ;
+.
+IBAL:Fan_5_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "Fan 5 E ICP" ;
+.
+IBAL:Fan_5_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Fan 5 ICP" ;
+.
+IBAL:Fan_5_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:AHU_3_OCP ;
+ rdfs:label "Fan 5 OCP" ;
+.
+IBAL:Fan_5_VFD_5
+ a s223:Connection ;
+ s223:cnx IBAL:Fan_5_E_ICP ;
+ s223:cnx IBAL:VFD_5_ICP ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "Fan 5 VFD 5" ;
+.
+IBAL:Flow_1
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_2 ;
+ s223:observes IBAL:Damper-2-InletFlow ;
+ rdfs:label "Flow 1" ;
+.
+IBAL:Flow_11
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_27 ;
+ s223:observes IBAL:ExhaustFan-1-InletFlow ;
+ rdfs:label "Flow 11" ;
+.
+IBAL:Flow_12
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_30 ;
+ s223:observes IBAL:ExhaustFan-2-InletFlow ;
+ rdfs:label "Flow 12" ;
+.
+IBAL:Flow_2
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_4 ;
+ s223:observes IBAL:Damper-2-InletFlow ;
+ rdfs:label "Flow 2" ;
+.
+IBAL:Flow_3
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_7 ;
+ s223:observes IBAL:Damper-3-InletFlow ;
+ rdfs:label "Flow 3" ;
+.
+IBAL:Flow_4
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_10 ;
+ s223:observes IBAL:Damper-4-InletFlow ;
+ rdfs:label "Flow 4" ;
+.
+IBAL:Flow_6
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:VAV_2_Connection_2 ;
+ s223:observes IBAL:HC-3-OutletFlow ;
+ rdfs:label "Flow 6" ;
+.
+IBAL:Flow_7
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:VAV_3_Connection_2 ;
+ s223:observes IBAL:HC-5-OutletFlow ;
+ rdfs:label "Flow 7" ;
+.
+IBAL:Flow_9
+ a s223:FlowSensor ;
+ s223:hasObservationLocation IBAL:Segment_20 ;
+ s223:observes IBAL:ReturnAir-1-Flow ;
+ rdfs:label "Flow 9" ;
+.
+IBAL:HC-1-InletHumidity
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "70"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "70" ;
+ rdfs:label "HC 1 InletHumidity" ;
+.
+IBAL:HC-1-InletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "40"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "40" ;
+ rdfs:label "HC 1 InletTemp" ;
+.
+IBAL:HC-2-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "70"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "HC 2 OutletTemp" ;
+.
+IBAL:HC-3-OutletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "500"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "500" ;
+ rdfs:label "HC 3 OutletFlow" ;
+.
+IBAL:HC-3-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "85"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "85" ;
+ rdfs:label "HC 3 OutletTemp" ;
+.
+IBAL:HC-5-OutletFlow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "20"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "20" ;
+ rdfs:label "HC 5 OutletFlow" ;
+.
+IBAL:HC-5-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "70"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "70" ;
+ rdfs:label "HC 5 OutletTemp" ;
+.
+IBAL:HC-7-InletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "45"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "HC 7 InletTemp" ;
+.
+IBAL:HC_1_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "HC 1 E ICP" ;
+.
+IBAL:HC_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:AHU_1_ICP ;
+ rdfs:label "HC 1 ICP" ;
+.
+IBAL:HC_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 1 OCP" ;
+.
+IBAL:HC_1_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "HC 1 W ICP" ;
+.
+IBAL:HC_2_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "HC 2 E ICP" ;
+.
+IBAL:HC_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 2 ICP" ;
+.
+IBAL:HC_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_1_OCP ;
+ rdfs:label "HC 2 OCP" ;
+.
+IBAL:HC_2_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 2 W ICP" ;
+.
+IBAL:HC_3_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "HC 3 E ICP" ;
+.
+IBAL:HC_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 3 ICP" ;
+.
+IBAL:HC_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_2_OCP ;
+ rdfs:label "HC 3 OCP" ;
+.
+IBAL:HC_3_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 3 W ICP" ;
+.
+IBAL:HC_4_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "HC 4 E ICP" ;
+.
+IBAL:HC_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:AHU_2_ICP ;
+ rdfs:label "HC 4 ICP" ;
+.
+IBAL:HC_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 4 OCP" ;
+.
+IBAL:HC_4_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 4 W ICP" ;
+.
+IBAL:HC_5_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "HC 5 E ICP" ;
+.
+IBAL:HC_5_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 5 ICP" ;
+.
+IBAL:HC_5_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_3_OCP ;
+ rdfs:label "HC 5 OCP" ;
+.
+IBAL:HC_5_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "HC 5 W ICP" ;
+.
+IBAL:HC_6_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "HC 6 E ICP" ;
+.
+IBAL:HC_6_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 6 ICP" ;
+.
+IBAL:HC_6_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:mapsTo IBAL:VAV_4_OCP ;
+ rdfs:label "HC 6 OCP" ;
+.
+IBAL:HC_6_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "HC 6 W ICP" ;
+.
+IBAL:HC_7_E_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "HC 7 E ICP" ;
+.
+IBAL:HC_7_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:AHU_3_Connection_2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 7 ICP" ;
+.
+IBAL:HC_7_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 7OCP" ;
+.
+IBAL:HC_7_W_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HC 7 W ICP" ;
+.
+IBAL:HVACSpace-1-OutletHumidity
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "80"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "80" ;
+ rdfs:label "HVAC Space 1 OutletHumidity" ;
+.
+IBAL:HVACSpace-1-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "80"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "80" ;
+ rdfs:label "HVAC Space 1 OutletTemp" ;
+.
+IBAL:HVACSpace-1-Temp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "66"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "66" ;
+ rdfs:label "HVAC Space 1 Temp" ;
+.
+IBAL:HVACSpace-2-OutletHumidity
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "50"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "HVAC Space 2 OutletHumidity" ;
+.
+IBAL:HVACSpace-2-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "65"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "65" ;
+ rdfs:label "HVAC Space 2 OutletTemp" ;
+.
+IBAL:HVACSpace-2-Temp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "70"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "70" ;
+ rdfs:label "HVAC Space 2 Temp" ;
+.
+IBAL:HVACSpace-3-OutletHumidity
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "50"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "HVAC Space 3 OutletHumidity" ;
+.
+IBAL:HVACSpace-3-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "72"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "72" ;
+ rdfs:label "HVAC Space 3 OutletTemp" ;
+.
+IBAL:HVACSpace-3-Temp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "66"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "66" ;
+ rdfs:label "HVAC Space 3 Temp" ;
+.
+IBAL:HVACSpace-4-OutletHumidity
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "30"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "HVAC Space 4 OutletHumidity" ;
+.
+IBAL:HVACSpace-4-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "80"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "80" ;
+ rdfs:label "HVAC Space 4 OutletTemp" ;
+.
+IBAL:HVACSpace-4-Temp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "68"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "68" ;
+ rdfs:label "HVAC Space 4 Temp" ;
+.
+IBAL:HVACSpace_1
+ a s223:DomainSpace ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_1_ICP ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_1_OCP ;
+ s223:hasDomain s223:Domain-HVAC ;
+ rdfs:label "HVACSpace 1" ;
+.
+IBAL:HVACSpace_2
+ a s223:DomainSpace ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_2_ICP ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_2_OCP ;
+ s223:hasDomain s223:Domain-HVAC ;
+ rdfs:label "HVACSpace 2" ;
+.
+IBAL:HVACSpace_3
+ a s223:DomainSpace ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_3_ICP ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_3_OCP ;
+ s223:hasDomain s223:Domain-HVAC ;
+ rdfs:label "HVACSpace 3" ;
+.
+IBAL:HVACSpace_4
+ a s223:DomainSpace ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_4_ICP ;
+ s223:hasConnectionPoint IBAL:HVAC_Space_4_OCP ;
+ s223:hasDomain s223:Domain-HVAC ;
+ rdfs:label "HVACSpace 4" ;
+.
+IBAL:HVACZone_1
+ a s223:Zone ;
+ s223:hasDomain s223:Domain-HVAC ;
+ s223:hasDomainSpace IBAL:HVACSpace_1 ;
+ rdfs:label "HVACZone 1" ;
+.
+IBAL:HVACZone_2
+ a s223:Zone ;
+ s223:hasDomain s223:Domain-HVAC ;
+ s223:hasDomainSpace IBAL:HVACSpace_2 ;
+ rdfs:label "HVACZone 2" ;
+.
+IBAL:HVACZone_3
+ a s223:Zone ;
+ s223:hasDomain s223:Domain-HVAC ;
+ s223:hasDomainSpace IBAL:HVACSpace_3 ;
+ rdfs:label "HVACZone 3" ;
+.
+IBAL:HVACZone_4
+ a s223:Zone ;
+ s223:hasDomain s223:Domain-HVAC ;
+ s223:hasDomainSpace IBAL:HVACSpace_4 ;
+ rdfs:label "HVACZone 4" ;
+.
+IBAL:HVAC_Space_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space 1 ICP" ;
+.
+IBAL:HVAC_Space_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_12 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space1 OCP" ;
+.
+IBAL:HVAC_Space_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space 2 ICP" ;
+.
+IBAL:HVAC_Space_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_14 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space2 OCP" ;
+.
+IBAL:HVAC_Space_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space 3 ICP" ;
+.
+IBAL:HVAC_Space_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_16 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space 3 OCP" ;
+.
+IBAL:HVAC_Space_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space 4 ICP" ;
+.
+IBAL:HVAC_Space_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_18 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "HVAC Space 4 OCP" ;
+.
+IBAL:HeatExchange
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "60" ;
+ rdfs:label "HeatExchange" ;
+.
+IBAL:HeatExchange_Connection
+ a s223:Connection ;
+ s223:cnx IBAL:PlateHeatExchange_2_Lower_OCP ;
+ s223:cnx IBAL:WaterPump_1_ICP ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Heat Exchange Connection" ;
+.
+IBAL:HeatExchange_Connection_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "72" ;
+ rdfs:label "HeatExchange_Connection_Temp" ;
+.
+IBAL:HeatingCoil_1
+ a s223:HeatingCoil ;
+ s223:hasConnectionPoint IBAL:HC_1_E_ICP ;
+ s223:hasConnectionPoint IBAL:HC_1_ICP ;
+ s223:hasConnectionPoint IBAL:HC_1_OCP ;
+ s223:hasConnectionPoint IBAL:HC_1_W_ICP ;
+ rdfs:label "Heating coil 1" ;
+.
+IBAL:HeatingCoil_2
+ a s223:HeatingCoil ;
+ s223:hasConnectionPoint IBAL:HC_2_E_ICP ;
+ s223:hasConnectionPoint IBAL:HC_2_ICP ;
+ s223:hasConnectionPoint IBAL:HC_2_OCP ;
+ s223:hasConnectionPoint IBAL:HC_2_W_ICP ;
+ rdfs:label "Heating coil 2" ;
+.
+IBAL:HeatingCoil_3
+ a s223:HeatingCoil ;
+ s223:hasConnectionPoint IBAL:HC_3_E_ICP ;
+ s223:hasConnectionPoint IBAL:HC_3_ICP ;
+ s223:hasConnectionPoint IBAL:HC_3_OCP ;
+ s223:hasConnectionPoint IBAL:HC_3_W_ICP ;
+ rdfs:label "Heating coil 3" ;
+.
+IBAL:HeatingCoil_4
+ a s223:HeatingCoil ;
+ s223:hasConnectionPoint IBAL:HC_4_E_ICP ;
+ s223:hasConnectionPoint IBAL:HC_4_ICP ;
+ s223:hasConnectionPoint IBAL:HC_4_OCP ;
+ s223:hasConnectionPoint IBAL:HC_4_W_ICP ;
+ rdfs:label "Heating coil 4" ;
+.
+IBAL:HeatingCoil_5
+ a s223:HeatingCoil ;
+ s223:hasConnectionPoint IBAL:HC_5_E_ICP ;
+ s223:hasConnectionPoint IBAL:HC_5_ICP ;
+ s223:hasConnectionPoint IBAL:HC_5_OCP ;
+ s223:hasConnectionPoint IBAL:HC_5_W_ICP ;
+ rdfs:label "Heating coil 5" ;
+.
+IBAL:HeatingCoil_6
+ a s223:HeatingCoil ;
+ s223:hasConnectionPoint IBAL:HC_6_E_ICP ;
+ s223:hasConnectionPoint IBAL:HC_6_ICP ;
+ s223:hasConnectionPoint IBAL:HC_6_OCP ;
+ s223:hasConnectionPoint IBAL:HC_6_W_ICP ;
+ s223:mapsTo "IBAL:VAV4_OCP" ;
+ rdfs:label "Heating coil 6" ;
+.
+IBAL:HeatingCoil_7
+ a s223:HeatingCoil ;
+ s223:hasConnectionPoint IBAL:HC_7_E_ICP ;
+ s223:hasConnectionPoint IBAL:HC_7_ICP ;
+ s223:hasConnectionPoint IBAL:HC_7_OCP ;
+ s223:hasConnectionPoint IBAL:HC_7_W_ICP ;
+ rdfs:label "Heating coil 7" ;
+.
+IBAL:Humidity_1
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:HC_1_ICP ;
+ s223:observes IBAL:HC-1-InletHumidity ;
+ rdfs:label "Humidity 1" ;
+.
+IBAL:Humidity_2
+ a s223:HumiditySensor ;
+ s223:observes IBAL:VFD-1-OutletHumidity ;
+ rdfs:label "Humidity 2" ;
+.
+IBAL:Humidity_3
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:Segment_12 ;
+ s223:observes IBAL:HVACSpace-1-OutletHumidity ;
+ rdfs:label "Humidity 3" ;
+.
+IBAL:Humidity_6
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:Segment_14 ;
+ s223:observes IBAL:HVACSpace-2-OutletHumidity ;
+ rdfs:label "Humidity 6" ;
+.
+IBAL:Humidity_7
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:Segment_16 ;
+ s223:observes IBAL:HVACSpace-3-OutletHumidity ;
+ rdfs:label "Humidity 7" ;
+.
+IBAL:Humidity_8
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:Segment_18 ;
+ s223:observes IBAL:HVACSpace-4-OutletHumidity ;
+ rdfs:label "Humidity 8" ;
+.
+IBAL:Humidity_9
+ a s223:HumiditySensor ;
+ s223:hasObservationLocation IBAL:Segment_44 ;
+ s223:observes IBAL:Segment_44_Humidity ;
+ rdfs:label "Humidity 9" ;
+.
+IBAL:Hydronic
+ a s223:System ;
+ s223:hasMember IBAL:CoolingCoil_1 ;
+ s223:hasMember IBAL:CoolingCoil_2 ;
+ s223:hasMember IBAL:PlateHeatExchanger_1 ;
+ s223:hasMember IBAL:PlateHeatExchanger_2 ;
+ s223:hasMember IBAL:ThermalStorage_1 ;
+ s223:hasMember IBAL:WaterChiller_1 ;
+ s223:hasMember IBAL:WaterChiller_2 ;
+.
+IBAL:Jnc1-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc1-ICP" ;
+.
+IBAL:Jnc1-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc1-OCP1" ;
+.
+IBAL:Jnc1-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc1-OCP2" ;
+.
+IBAL:Jnc10-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc10-ICP1" ;
+.
+IBAL:Jnc10-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc10-ICP2" ;
+.
+IBAL:Jnc10-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc10-OCP" ;
+.
+IBAL:Jnc11-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc11-ICP1" ;
+.
+IBAL:Jnc11-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc11-ICP2" ;
+.
+IBAL:Jnc12-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc12-ICP" ;
+.
+IBAL:Jnc12-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc12-OCP1" ;
+.
+IBAL:Jnc12-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_39 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc12-OCP2" ;
+.
+IBAL:Jnc13-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc13-ICP1" ;
+.
+IBAL:Jnc13-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc13-ICP2" ;
+.
+IBAL:Jnc13-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc13-OCP" ;
+.
+IBAL:Jnc14-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc14-ICP1" ;
+.
+IBAL:Jnc14-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc14-ICP2" ;
+.
+IBAL:Jnc14-OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_42 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc14-OCP" ;
+.
+IBAL:Jnc15-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc15-ICP" ;
+.
+IBAL:Jnc15-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc15-OCP1" ;
+.
+IBAL:Jnc15-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc15-OCP2" ;
+.
+IBAL:Jnc16-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc16-ICP" ;
+.
+IBAL:Jnc16-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc16-OCP1" ;
+.
+IBAL:Jnc16-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc16-OCP2" ;
+.
+IBAL:Jnc17-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc17-ICP" ;
+.
+IBAL:Jnc17-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:Junction_15 ;
+ rdfs:label "Jnc17-ICP1" ;
+.
+IBAL:Jnc17-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc17-ICP2" ;
+.
+IBAL:Jnc17-OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_52 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc17-OCP" ;
+.
+IBAL:Jnc18-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc18-ICP" ;
+.
+IBAL:Jnc18-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc18-OCP" ;
+.
+IBAL:Jnc18-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc18-OCP2" ;
+.
+IBAL:Jnc19-ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_102 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc19-ICP" ;
+.
+IBAL:Jnc19-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc19-OCP" ;
+.
+IBAL:Jnc19-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc19-OCP2" ;
+.
+IBAL:Jnc2-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc2-ICP" ;
+.
+IBAL:Jnc2-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc2-OCP" ;
+.
+IBAL:Jnc2-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:isConnectionPointOf IBAL:Junction_2 ;
+ rdfs:label "Jnc2-OCP1" ;
+.
+IBAL:Jnc2-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc2-OCP2" ;
+.
+IBAL:Jnc20-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc20-ICP" ;
+.
+IBAL:Jnc20-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc20-OCP" ;
+.
+IBAL:Jnc21-ICP1
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_61 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc21-ICP1" ;
+.
+IBAL:Jnc21-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc21-ICP2" ;
+.
+IBAL:Jnc21-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc21-OCP" ;
+.
+IBAL:Jnc22-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc22-ICP" ;
+.
+IBAL:Jnc22-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc22-OCP1" ;
+.
+IBAL:Jnc22-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc22-OCP2" ;
+.
+IBAL:Jnc23-ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_62 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc23-ICP" ;
+.
+IBAL:Jnc23-ICP2
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_107 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc23-ICP2" ;
+.
+IBAL:Jnc23-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc23-OCP" ;
+.
+IBAL:Jnc24-ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_67 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc24-ICP" ;
+.
+IBAL:Jnc24-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc24-OCP1" ;
+.
+IBAL:Jnc24-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc24-OCP2" ;
+.
+IBAL:Jnc25-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc25-ICP" ;
+.
+IBAL:Jnc25-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc25-OCP1" ;
+.
+IBAL:Jnc25-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_71 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc25-OCP2" ;
+.
+IBAL:Jnc26-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc26-ICP1" ;
+.
+IBAL:Jnc26-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc26-ICP2" ;
+.
+IBAL:Jnc26-OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_76 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc26-OCP" ;
+.
+IBAL:Jnc27-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc27-ICP" ;
+.
+IBAL:Jnc27-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc27-OCP1" ;
+.
+IBAL:Jnc27-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc27-OCP2" ;
+.
+IBAL:Jnc28-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc28-ICP" ;
+.
+IBAL:Jnc28-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_77 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc28-OCP1" ;
+.
+IBAL:Jnc28-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc28-OCP2" ;
+.
+IBAL:Jnc29-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc29-ICP" ;
+.
+IBAL:Jnc29-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc29-OCP" ;
+.
+IBAL:Jnc3-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc3-ICP1" ;
+.
+IBAL:Jnc3-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc3-ICP2" ;
+.
+IBAL:Jnc3-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc3-OCP" ;
+.
+IBAL:Jnc30-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc30-ICP" ;
+.
+IBAL:Jnc30-OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_84 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc30-OCP" ;
+.
+IBAL:Jnc31-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc31-ICP1" ;
+.
+IBAL:Jnc31-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc31-ICP2" ;
+.
+IBAL:Jnc31-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc31-OCP" ;
+.
+IBAL:Jnc32-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc32-ICP1" ;
+.
+IBAL:Jnc32-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc32-ICP2" ;
+.
+IBAL:Jnc32-OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_88 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc32-OCP" ;
+.
+IBAL:Jnc33-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc33-ICP1" ;
+.
+IBAL:Jnc33-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ s223:isConnectionPointOf IBAL:Junction_33 ;
+ rdfs:label "Jnc33-ICP2" ;
+.
+IBAL:Jnc33-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc33-OCP" ;
+.
+IBAL:Jnc33-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc33-OCP2" ;
+.
+IBAL:Jnc34-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc34-ICP" ;
+.
+IBAL:Jnc34-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc34-OCP1" ;
+.
+IBAL:Jnc34-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc34-OCP2" ;
+.
+IBAL:Jnc35-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc35-ICP1" ;
+.
+IBAL:Jnc35-ICP2
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_93 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc35-ICP2" ;
+.
+IBAL:Jnc35-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc35-OCP" ;
+.
+IBAL:Jnc36-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc36-ICP" ;
+.
+IBAL:Jnc36-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc36-OCP1" ;
+.
+IBAL:Jnc36-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_98 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc36-OCP2" ;
+.
+IBAL:Jnc37-ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_99 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc37-ICP" ;
+.
+IBAL:Jnc37-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc37-OCP1" ;
+.
+IBAL:Jnc37-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc37-OCP2" ;
+.
+IBAL:Jnc38-ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_100 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc38-ICP" ;
+.
+IBAL:Jnc38-OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_101 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Jnc38-OCP" ;
+.
+IBAL:Jnc4-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc4-ICP" ;
+.
+IBAL:Jnc4-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc4-OCP1" ;
+.
+IBAL:Jnc4-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc4-OCP2" ;
+.
+IBAL:Jnc5-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc5-ICP1" ;
+.
+IBAL:Jnc5-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc5-ICP2" ;
+.
+IBAL:Jnc5-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc5-OCP" ;
+.
+IBAL:Jnc6-ICP1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc6-ICP1" ;
+.
+IBAL:Jnc6-ICP2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc6-ICP2" ;
+.
+IBAL:Jnc6-OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_22 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc6-OCP" ;
+.
+IBAL:Jnc7-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc7-ICP" ;
+.
+IBAL:Jnc7-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc7-OCP1" ;
+.
+IBAL:Jnc7-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc7-OCP2" ;
+.
+IBAL:Jnc8-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc8-ICP" ;
+.
+IBAL:Jnc8-OCP1
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc8-OCP1" ;
+.
+IBAL:Jnc8-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc8-OCP2" ;
+.
+IBAL:Jnc9-ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc9-ICP" ;
+.
+IBAL:Jnc9-OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc9-OCP" ;
+.
+IBAL:Jnc9-OCP2
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_27 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Jnc9-OCP2" ;
+.
+IBAL:Junction_1
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc1-ICP ;
+ s223:cnx IBAL:Jnc1-OCP1 ;
+ s223:cnx IBAL:Jnc1-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 1" ;
+.
+IBAL:Junction_10
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc10-ICP1 ;
+ s223:cnx IBAL:Jnc10-ICP2 ;
+ s223:cnx IBAL:Jnc10-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 10" ;
+.
+IBAL:Junction_11
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc11-ICP1 ;
+ s223:cnx IBAL:Jnc11-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 11" ;
+.
+IBAL:Junction_12
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc12-ICP ;
+ s223:cnx IBAL:Jnc12-OCP1 ;
+ s223:cnx IBAL:Jnc12-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 12" ;
+.
+IBAL:Junction_13
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc13-ICP1 ;
+ s223:cnx IBAL:Jnc13-ICP2 ;
+ s223:cnx IBAL:Jnc13-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 13" ;
+.
+IBAL:Junction_14
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc14-ICP1 ;
+ s223:cnx IBAL:Jnc14-ICP2 ;
+ s223:cnx IBAL:Jnc14-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 14" ;
+.
+IBAL:Junction_15
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc15-ICP ;
+ s223:cnx IBAL:Jnc15-OCP1 ;
+ s223:cnx IBAL:Jnc15-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 15" ;
+.
+IBAL:Junction_16
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc16-ICP ;
+ s223:cnx IBAL:Jnc16-OCP1 ;
+ s223:cnx IBAL:Jnc16-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 16" ;
+.
+IBAL:Junction_17
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc17-ICP ;
+ s223:cnx IBAL:Jnc17-ICP2 ;
+ s223:cnx IBAL:Jnc17-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 17" ;
+.
+IBAL:Junction_18
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc18-ICP ;
+ s223:cnx IBAL:Jnc18-OCP ;
+ s223:cnx IBAL:Jnc18-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 18" ;
+.
+IBAL:Junction_19
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc19-ICP ;
+ s223:cnx IBAL:Jnc19-OCP ;
+ s223:cnx IBAL:Jnc19-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 19" ;
+.
+IBAL:Junction_2
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc2-ICP ;
+ s223:cnx IBAL:Jnc2-OCP ;
+ s223:cnx IBAL:Jnc2-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 2" ;
+.
+IBAL:Junction_20
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc20-ICP ;
+ s223:cnx IBAL:Jnc20-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 20" ;
+.
+IBAL:Junction_21
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc21-ICP1 ;
+ s223:cnx IBAL:Jnc21-ICP2 ;
+ s223:cnx IBAL:Jnc21-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 21" ;
+.
+IBAL:Junction_22
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc22-ICP ;
+ s223:cnx IBAL:Jnc22-OCP1 ;
+ s223:cnx IBAL:Jnc22-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 22" ;
+.
+IBAL:Junction_23
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc23-ICP ;
+ s223:cnx IBAL:Jnc23-ICP2 ;
+ s223:cnx IBAL:Jnc23-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 23" ;
+.
+IBAL:Junction_24
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc24-ICP ;
+ s223:cnx IBAL:Jnc24-OCP1 ;
+ s223:cnx IBAL:Jnc24-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 24" ;
+.
+IBAL:Junction_25
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc25-ICP ;
+ s223:cnx IBAL:Jnc25-OCP1 ;
+ s223:cnx IBAL:Jnc25-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 25" ;
+.
+IBAL:Junction_26
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc26-ICP1 ;
+ s223:cnx IBAL:Jnc26-ICP2 ;
+ s223:cnx IBAL:Jnc26-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 26" ;
+.
+IBAL:Junction_27
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc27-ICP ;
+ s223:cnx IBAL:Jnc27-OCP1 ;
+ s223:cnx IBAL:Jnc27-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 27" ;
+.
+IBAL:Junction_28
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc28-ICP ;
+ s223:cnx IBAL:Jnc28-OCP1 ;
+ s223:cnx IBAL:Jnc28-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 28" ;
+.
+IBAL:Junction_29
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc29-ICP ;
+ s223:cnx IBAL:Jnc29-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 29" ;
+.
+IBAL:Junction_3
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc3-ICP1 ;
+ s223:cnx IBAL:Jnc3-ICP2 ;
+ s223:cnx IBAL:Jnc3-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 3" ;
+.
+IBAL:Junction_30
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc30-ICP ;
+ s223:cnx IBAL:Jnc30-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 30" ;
+.
+IBAL:Junction_31
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc31-ICP1 ;
+ s223:cnx IBAL:Jnc31-ICP2 ;
+ s223:cnx IBAL:Jnc31-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 31" ;
+.
+IBAL:Junction_32
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc32-ICP1 ;
+ s223:cnx IBAL:Jnc32-ICP2 ;
+ s223:cnx IBAL:Jnc32-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 32" ;
+.
+IBAL:Junction_33
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc33-ICP1 ;
+ s223:cnx IBAL:Jnc33-OCP ;
+ s223:cnx IBAL:Jnc33-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 33" ;
+.
+IBAL:Junction_34
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc34-ICP ;
+ s223:cnx IBAL:Jnc34-OCP1 ;
+ s223:cnx IBAL:Jnc34-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 34" ;
+.
+IBAL:Junction_35
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc35-ICP1 ;
+ s223:cnx IBAL:Jnc35-ICP2 ;
+ s223:cnx IBAL:Jnc35-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 35" ;
+.
+IBAL:Junction_36
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc36-ICP ;
+ s223:cnx IBAL:Jnc36-OCP1 ;
+ s223:cnx IBAL:Jnc36-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 36" ;
+.
+IBAL:Junction_37
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc37-ICP ;
+ s223:cnx IBAL:Jnc37-OCP1 ;
+ s223:cnx IBAL:Jnc37-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 37" ;
+.
+IBAL:Junction_38
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc38-ICP ;
+ s223:cnx IBAL:Jnc38-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Junction 38" ;
+.
+IBAL:Junction_4
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc4-ICP ;
+ s223:cnx IBAL:Jnc4-OCP1 ;
+ s223:cnx IBAL:Jnc4-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 4" ;
+.
+IBAL:Junction_5
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc5-ICP1 ;
+ s223:cnx IBAL:Jnc5-ICP2 ;
+ s223:cnx IBAL:Jnc5-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 5" ;
+.
+IBAL:Junction_6
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc6-ICP1 ;
+ s223:cnx IBAL:Jnc6-ICP2 ;
+ s223:cnx IBAL:Jnc6-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 6" ;
+.
+IBAL:Junction_7
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc7-ICP ;
+ s223:cnx IBAL:Jnc7-OCP1 ;
+ s223:cnx IBAL:Jnc7-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 7" ;
+.
+IBAL:Junction_8
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc8-ICP ;
+ s223:cnx IBAL:Jnc8-OCP1 ;
+ s223:cnx IBAL:Jnc8-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 8" ;
+.
+IBAL:Junction_9
+ a s223:Junction ;
+ s223:cnx IBAL:Jnc9-ICP ;
+ s223:cnx IBAL:Jnc9-OCP ;
+ s223:cnx IBAL:Jnc9-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Junction 9" ;
+.
+IBAL:ManualTwoWayValve_1
+ a s223:TwoWayValve ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_1_ICP ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_1_OCP ;
+ rdfs:label "Manual two way valve 1" ;
+.
+IBAL:ManualTwoWayValve_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 1 ICP" ;
+.
+IBAL:ManualTwoWayValve_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 1 OCP" ;
+.
+IBAL:ManualTwoWayValve_2
+ a s223:TwoWayValve ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_2_ICP ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_2_OCP ;
+ rdfs:label "Manual two way valve 2" ;
+.
+IBAL:ManualTwoWayValve_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 2 ICP" ;
+.
+IBAL:ManualTwoWayValve_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 2 OCP" ;
+.
+IBAL:ManualTwoWayValve_3
+ a s223:TwoWayValve ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_3_ICP ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_3_OCP ;
+ rdfs:label "Manual two way valve 3" ;
+.
+IBAL:ManualTwoWayValve_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 3 ICP" ;
+.
+IBAL:ManualTwoWayValve_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 3 OCP" ;
+.
+IBAL:ManualTwoWayValve_4
+ a s223:TwoWayValve ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_4_ICP ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_4_OCP ;
+ rdfs:label "Manual two way valve 4" ;
+.
+IBAL:ManualTwoWayValve_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 4 ICP" ;
+.
+IBAL:ManualTwoWayValve_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 4 OCP" ;
+.
+IBAL:ManualTwoWayValve_5
+ a s223:TwoWayValve ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_5_ICP ;
+ s223:hasConnectionPoint IBAL:ManualTwoWayValve_5_OCP ;
+ rdfs:label "Manual two way valve 5" ;
+.
+IBAL:ManualTwoWayValve_5_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 5 ICP" ;
+.
+IBAL:ManualTwoWayValve_5_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:Segment_87 ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Manual two way valve 5 OCP" ;
+.
+IBAL:MotorizedDamper_1
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_1_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_1_OCP ;
+ rdfs:label "Motorized damper 1" ;
+.
+IBAL:MotorizedDamper_10
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_10_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_10_OCP ;
+ rdfs:label "Motorized damper 10" ;
+.
+IBAL:MotorizedDamper_11
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_11_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_11_OCP ;
+ rdfs:label "Motorized damper 11" ;
+.
+IBAL:MotorizedDamper_12
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_12_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_12_OCP ;
+ rdfs:label "Motorized damper 12" ;
+.
+IBAL:MotorizedDamper_13
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_13_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_13_OCP ;
+ rdfs:label "Motorized damper 13" ;
+.
+IBAL:MotorizedDamper_14
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_14_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_14_OCP ;
+ rdfs:label "Motorized damper 14" ;
+.
+IBAL:MotorizedDamper_15
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_15_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_15_OCP ;
+ rdfs:label "Motorized damper 15" ;
+.
+IBAL:MotorizedDamper_16
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_16_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_16_OCP ;
+ rdfs:label "Motorized damper 16" ;
+.
+IBAL:MotorizedDamper_17
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_17_ICP ;
+ rdfs:label "Motorized damper 17" ;
+.
+IBAL:MotorizedDamper_18
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_18_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_18_OCP ;
+ rdfs:label "Motorized damper 18" ;
+.
+IBAL:MotorizedDamper_19
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_19_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_19_OCP ;
+ rdfs:label "Motorized damper 19" ;
+.
+IBAL:MotorizedDamper_2
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_2_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_2_OCP ;
+ rdfs:label "Motorized damper 2" ;
+.
+IBAL:MotorizedDamper_3
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_3_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_3_OCP ;
+ rdfs:label "Motorized damper 3" ;
+.
+IBAL:MotorizedDamper_4
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_4_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_4_OCP ;
+ s223:mapsTo "IBAL:VAV4_ICP" ;
+ rdfs:label "Motorized damper 4" ;
+.
+IBAL:MotorizedDamper_5
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_5_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_5_OCP ;
+ rdfs:label "Motorized damper 5" ;
+.
+IBAL:MotorizedDamper_6
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_6_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_6_OCP ;
+ rdfs:label "Motorized damper 6" ;
+.
+IBAL:MotorizedDamper_7
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_7_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_7_OCP ;
+ rdfs:label "Motorized damper 7" ;
+.
+IBAL:MotorizedDamper_8
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_8_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_8_OCP ;
+ rdfs:label "Motorized damper 8" ;
+.
+IBAL:MotorizedDamper_9
+ a s223:Damper ;
+ s223:hasConnectionPoint IBAL:Damper_9_ICP ;
+ s223:hasConnectionPoint IBAL:Damper_9_OCP ;
+ rdfs:label "Motorized damper 9" ;
+.
+IBAL:MotorizedThreeWayValve_1
+ a s223:ThreeWayValve ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_1_ICP_1 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_1_ICP_2 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_1_OCP ;
+ rdfs:label "Motorized three way valve 1" ;
+.
+IBAL:MotorizedThreeWayValve_1_ICP_1
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_105 ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_1 ;
+ rdfs:label "Motorized three way valve 1 ICP 1" ;
+.
+IBAL:MotorizedThreeWayValve_1_ICP_2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Motorized three way valve 1 ICP 2" ;
+.
+IBAL:MotorizedThreeWayValve_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Motorized three way valve 1 OCP" ;
+.
+IBAL:MotorizedThreeWayValve_2
+ a s223:ThreeWayValve ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_2_ICP_1 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_2_ICP_2 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_2_OCP ;
+ rdfs:label "Motorized three way valve 2" ;
+.
+IBAL:MotorizedThreeWayValve_2_ICP_1
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_106 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_2 ;
+ rdfs:label "Motorized three way valve 2 ICP 1" ;
+.
+IBAL:MotorizedThreeWayValve_2_ICP_2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_2 ;
+ rdfs:label "Motorized three way valve 2 ICP 2" ;
+.
+IBAL:MotorizedThreeWayValve_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_2 ;
+ rdfs:label "Motorized three way valve 2 OCP" ;
+.
+IBAL:MotorizedThreeWayValve_3
+ a s223:ThreeWayValve ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_3_ICP_1 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_3_ICP_2 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_3_OCP ;
+ rdfs:label "Motorized three way valve 3" ;
+.
+IBAL:MotorizedThreeWayValve_3_ICP_1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_3 ;
+ rdfs:label "Motorized three way valve 3 ICP 1" ;
+.
+IBAL:MotorizedThreeWayValve_3_ICP_2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_3 ;
+ rdfs:label "Motorized three way valve 3 ICP 2" ;
+.
+IBAL:MotorizedThreeWayValve_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_3 ;
+ rdfs:label "Motorized three way valve 3 OCP" ;
+.
+IBAL:MotorizedThreeWayValve_4
+ a s223:ThreeWayValve ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_4_ICP_1 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_4_ICP_2 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_4_OCP ;
+ rdfs:label "Motorized three way valve 4" ;
+.
+IBAL:MotorizedThreeWayValve_4_ICP_1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_4 ;
+ rdfs:label "Motorized three way valve 4 ICP 1" ;
+.
+IBAL:MotorizedThreeWayValve_4_ICP_2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Motorized three way valve 4 ICP 2" ;
+.
+IBAL:MotorizedThreeWayValve_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_4 ;
+ rdfs:label "Motorized three way valve 4 OCP" ;
+.
+IBAL:MotorizedThreeWayValve_5
+ a s223:ThreeWayValve ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_5_ICP_1 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_5_ICP_2 ;
+ s223:hasConnectionPoint IBAL:MotorizedThreeWayValve_5_OCP ;
+ rdfs:label "Motorized three way valve 5" ;
+.
+IBAL:MotorizedThreeWayValve_5_ICP_1
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_5 ;
+ rdfs:label "Motorized three way valve 5 ICP 1" ;
+.
+IBAL:MotorizedThreeWayValve_5_ICP_2
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_5 ;
+ rdfs:label "Motorized three way valve 5 ICP 2" ;
+.
+IBAL:MotorizedThreeWayValve_5_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ s223:isConnectionPointOf IBAL:MotorizedThreeWayValve_5 ;
+ rdfs:label "Motorized three way valve 5 OCP" ;
+.
+IBAL:PlateHeatExchange_1_Connection
+ a s223:Connection ;
+ s223:connectsAt IBAL:MotorizedThreeWayValve_3_ICP_1 ;
+ s223:connectsAt IBAL:PlateHeatExchange_1_Lower_OCP ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Plate Heat Exchange 1 Connection" ;
+.
+IBAL:PlateHeatExchange_1_ConnectionTemperature
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "60"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "Plate heat exchange 1 Connection temperature" ;
+.
+IBAL:PlateHeatExchange_1_Connection_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "70" ;
+ rdfs:label "PlateHeatExchange_1_Connection_Temp" ;
+.
+IBAL:PlateHeatExchange_1_Lower_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Plate Heat Exchange 1 Lower ICP" ;
+.
+IBAL:PlateHeatExchange_1_Lower_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Plate Heat Exchange 1 Lower OCP" ;
+.
+IBAL:PlateHeatExchange_1_Upper_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Plate Heat Exchange 1 Upper ICP" ;
+.
+IBAL:PlateHeatExchange_1_Upper_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Plate Heat Exchange 1 Upper OCP" ;
+.
+IBAL:PlateHeatExchange_2_Lower_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Plate Heat Exchange 2 Lower ICP" ;
+.
+IBAL:PlateHeatExchange_2_Lower_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Plate Heat Exchange 2 Lower OCP" ;
+.
+IBAL:PlateHeatExchange_2_Upper_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Plate Heat Exchange 2 Upper ICP" ;
+.
+IBAL:PlateHeatExchange_2_Upper_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Plate Heat Exchange 2 Upper OCP" ;
+.
+IBAL:PlateHeatExchanger_1
+ a s223:HeatExchanger ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_1_Lower_ICP ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_1_Lower_OCP ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_1_Upper_ICP ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_1_Upper_OCP ;
+ rdfs:label "Plate heat exchanger 1" ;
+.
+IBAL:PlateHeatExchanger_2
+ a s223:HeatExchanger ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_2_Lower_ICP ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_2_Lower_OCP ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_2_Upper_ICP ;
+ s223:hasConnectionPoint IBAL:PlateHeatExchange_2_Upper_OCP ;
+ rdfs:label "Plate heat exchanger 1" ;
+.
+IBAL:PlateHetExchange_1_Bypass_Connection
+ a s223:Pipe ;
+ s223:connectsAt IBAL:ManualTwoWayValve_3_OCP ;
+ s223:connectsAt IBAL:MotorizedThreeWayValve_3_ICP_2 ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Plate Heat Exchange 1 Bypass Connection" ;
+.
+IBAL:Pressure_1
+ a s223:PressureSensor ;
+ s223:hasObservationLocation IBAL:AHU_1_Connection_3 ;
+ s223:observes IBAL:VFD-1-InletPressure ;
+ rdfs:label "Pressure 1" ;
+.
+IBAL:Pressure_4
+ a s223:PressureSensor ;
+ s223:observes IBAL:VFD-2-OutletPressure ;
+ rdfs:label "Pressure 4" ;
+.
+IBAL:Pressure_5
+ a s223:PressureSensor ;
+ s223:hasObservationLocation IBAL:Segment_27 ;
+ s223:observes IBAL:ExhaustFan-1-InletPressure ;
+ rdfs:label "Pressure 5" ;
+.
+IBAL:Pressure_6
+ a s223:PressureSensor ;
+ s223:hasObservationLocation IBAL:Segment_30 ;
+ s223:observes IBAL:ExhaustFan-2-InletPressure ;
+ rdfs:label "Pressure 6" ;
+.
+IBAL:Pressure_7
+ a s223:PressureSensor ;
+ s223:hasObservationLocation IBAL:AHU_3_Connection_3 ;
+ s223:observes IBAL:VFD-5-InletPressure ;
+ rdfs:label "Pressure 7" ;
+.
+IBAL:Pressure_8
+ a s223:PressureSensor ;
+ s223:hasObservationLocation IBAL:Segment_44 ;
+ s223:observes IBAL:VFD-5-OutletPressure ;
+ rdfs:label "Pressure 8" ;
+.
+IBAL:ReturnAir-1-Flow
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "500"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "500" ;
+ rdfs:label "Return Air 1 Flow" ;
+.
+IBAL:Segment_1
+ a s223:Connection ;
+ s223:cnx IBAL:AHU_1_OCP ;
+ s223:cnx IBAL:Jnc1-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 1" ;
+.
+IBAL:Segment_10
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc4-OCP2 ;
+ s223:cnx IBAL:VAV_4_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 10" ;
+.
+IBAL:Segment_100
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc37-OCP1 ;
+ s223:cnx IBAL:Jnc38-ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 100" ;
+.
+IBAL:Segment_101
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc18-ICP ;
+ s223:cnx IBAL:Jnc38-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 101" ;
+.
+IBAL:Segment_102
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc19-ICP ;
+ s223:cnx IBAL:Jnc37-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 102" ;
+.
+IBAL:Segment_103
+ a s223:Connection ;
+ s223:cnx IBAL:AHU_1_G_ICP ;
+ s223:cnx IBAL:Jnc19-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 103" ;
+.
+IBAL:Segment_104
+ a s223:Connection ;
+ s223:connectsAt IBAL:MotorizedThreeWayValve_5_ICP_1 ;
+ s223:connectsAt IBAL:ThermalStorage_1_OCP ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Segment 104" ;
+.
+IBAL:Segment_105
+ a s223:Connection ;
+ s223:cnx IBAL:AHU_1_G_OCP ;
+ s223:cnx IBAL:MotorizedThreeWayValve_1_ICP_1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 105" ;
+.
+IBAL:Segment_106
+ a s223:Connection ;
+ s223:cnx IBAL:AHU_2_G_OCP ;
+ s223:cnx IBAL:MotorizedThreeWayValve_2_ICP_1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 106" ;
+.
+IBAL:Segment_107
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc23-ICP2 ;
+ s223:cnx IBAL:MotorizedThreeWayValve_3_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 107" ;
+.
+IBAL:Segment_12
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_1_OCP ;
+ s223:cnx IBAL:Jnc5-ICP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 12" ;
+.
+IBAL:Segment_13
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc19-OCP ;
+ s223:cnx IBAL:ManualTwoWayValve_2_ICP ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Segment 13" ;
+.
+IBAL:Segment_14
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_2_OCP ;
+ s223:cnx IBAL:Jnc5-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 14" ;
+.
+IBAL:Segment_16
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_3_OCP ;
+ s223:cnx IBAL:Jnc6-ICP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 16" ;
+.
+IBAL:Segment_18
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_4_OCP ;
+ s223:cnx IBAL:Jnc6-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 18" ;
+.
+IBAL:Segment_19
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc5-OCP ;
+ s223:cnx IBAL:Jnc7-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 19" ;
+.
+IBAL:Segment_2
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc1-OCP2 ;
+ s223:cnx IBAL:VAV_1_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 2" ;
+.
+IBAL:Segment_20
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_12_ICP ;
+ s223:cnx IBAL:Jnc7-OCP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 20" ;
+.
+IBAL:Segment_21
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_6_ICP ;
+ s223:cnx IBAL:Jnc7-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 21" ;
+.
+IBAL:Segment_22
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc6-OCP ;
+ s223:cnx IBAL:Jnc8-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 22" ;
+.
+IBAL:Segment_23
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_14_ICP ;
+ s223:cnx IBAL:Jnc8-OCP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 23" ;
+.
+IBAL:Segment_24
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_8_ICP ;
+ s223:cnx IBAL:Jnc8-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 24" ;
+.
+IBAL:Segment_25
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_6_OCP ;
+ s223:cnx IBAL:Jnc9-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 25" ;
+.
+IBAL:Segment_26
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_10_ICP ;
+ s223:cnx IBAL:Jnc9-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 26" ;
+.
+IBAL:Segment_27
+ a s223:Connection ;
+ s223:cnx IBAL:Fan_3_ICP ;
+ s223:cnx IBAL:Jnc9-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 27" ;
+.
+IBAL:Segment_28
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_8_OCP ;
+ s223:cnx IBAL:Jnc10-ICP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 28" ;
+.
+IBAL:Segment_29
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_10_OCP ;
+ s223:cnx IBAL:Jnc10-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 29" ;
+.
+IBAL:Segment_3
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc1-OCP1 ;
+ s223:cnx IBAL:Jnc2-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 3" ;
+.
+IBAL:Segment_30
+ a s223:Connection ;
+ s223:cnx IBAL:Fan_4_ICP ;
+ s223:cnx IBAL:Jnc10-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 30" ;
+.
+IBAL:Segment_32
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_7_OCP ;
+ s223:cnx IBAL:Jnc11-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 32" ;
+.
+IBAL:Segment_33
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_9_OCP ;
+ s223:cnx IBAL:Jnc11-ICP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 33" ;
+.
+IBAL:Segment_35
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc13-ICP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 35" ;
+.
+IBAL:Segment_36
+ a s223:Connection ;
+ s223:cnx IBAL:AHU_1_ICP ;
+ s223:cnx IBAL:Jnc13-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 36" ;
+.
+IBAL:Segment_37
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_12_OCP ;
+ s223:cnx IBAL:Jnc13-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 37" ;
+.
+IBAL:Segment_38
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_13_ICP ;
+ s223:cnx IBAL:Jnc12-OCP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 38" ;
+.
+IBAL:Segment_39
+ a s223:Connection ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 39" ;
+.
+IBAL:Segment_4
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc2-OCP2 ;
+ s223:cnx IBAL:VAV_2_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 4" ;
+.
+IBAL:Segment_40
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_14_OCP ;
+ s223:cnx IBAL:Jnc14-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 40" ;
+.
+IBAL:Segment_41
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_13_OCP ;
+ s223:cnx IBAL:Jnc14-ICP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 41" ;
+.
+IBAL:Segment_42
+ a s223:Connection ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:lnx IBAL:HC_4_ICP ;
+ rdfs:label "Segment 42" ;
+.
+IBAL:Segment_43
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_15_OCP ;
+ s223:cnx IBAL:Jnc12-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 43" ;
+.
+IBAL:Segment_44
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc15-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 44" ;
+.
+IBAL:Segment_44_Humidity
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "80" ;
+ rdfs:label "Segment 44 Property" ;
+.
+IBAL:Segment_45
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_15_ICP ;
+ s223:cnx IBAL:Jnc15-OCP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 45" ;
+.
+IBAL:Segment_46
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_16_ICP ;
+ s223:cnx IBAL:Jnc15-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 46" ;
+.
+IBAL:Segment_47
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_16_OCP ;
+ s223:cnx IBAL:Jnc16-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 47" ;
+.
+IBAL:Segment_48
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_17_ICP ;
+ s223:cnx IBAL:Jnc16-OCP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 48" ;
+.
+IBAL:Segment_49
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_18_ICP ;
+ s223:cnx IBAL:Jnc16-OCP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 49" ;
+.
+IBAL:Segment_5
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_5_ICP ;
+ s223:cnx IBAL:Jnc2-OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 5" ;
+.
+IBAL:Segment_50
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_18_OCP ;
+ s223:cnx IBAL:Jnc17-ICP2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 50" ;
+.
+IBAL:Segment_51
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_19_OCP ;
+ s223:cnx IBAL:Jnc17-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 51" ;
+.
+IBAL:Segment_52
+ a s223:Connection ;
+ s223:hasMedium s223:Medium-Air ;
+ s223:lnx IBAL:AHU_3_ICP ;
+ rdfs:label "Segment 52" ;
+.
+IBAL:Segment_56
+ a s223:Connection ;
+ s223:cnx IBAL:AHU_2_G_ICP ;
+ s223:cnx IBAL:Jnc18-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 56" ;
+.
+IBAL:Segment_57
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc18-OCP2 ;
+ s223:cnx IBAL:ManualTwoWayValve_1_ICP ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Segment 57" ;
+.
+IBAL:Segment_59
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc21-ICP2 ;
+ s223:cnx IBAL:MotorizedThreeWayValve_1_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 59" ;
+.
+IBAL:Segment_6
+ a s223:Connection ;
+ s223:cnx IBAL:Damper_5_OCP ;
+ s223:cnx IBAL:Jnc3-ICP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 6" ;
+.
+IBAL:Segment_60
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc20-ICP ;
+ s223:cnx IBAL:MotorizedThreeWayValve_2_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 60" ;
+.
+IBAL:Segment_61
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc20-OCP ;
+ s223:cnx IBAL:Jnc21-ICP1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 61" ;
+.
+IBAL:Segment_62
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc21-OCP ;
+ s223:cnx IBAL:Jnc23-ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 62" ;
+.
+IBAL:Segment_63
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc22-OCP1 ;
+ s223:cnx IBAL:PlateHeatExchange_1_Lower_ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 63" ;
+.
+IBAL:Segment_64
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc22-OCP2 ;
+ s223:cnx IBAL:ManualTwoWayValve_3_ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 64" ;
+.
+IBAL:Segment_67
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc23-OCP ;
+ s223:cnx IBAL:Jnc24-ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 67" ;
+.
+IBAL:Segment_67_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "64" ;
+ rdfs:label "Segment_67_Temp" ;
+.
+IBAL:Segment_68
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc24-OCP1 ;
+ s223:cnx IBAL:MotorizedThreeWayValve_4_ICP_1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 68" ;
+.
+IBAL:Segment_69
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc25-ICP ;
+ s223:cnx IBAL:MotorizedThreeWayValve_4_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 69" ;
+.
+IBAL:Segment_69_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "65" ;
+ rdfs:label "Segment_69_Temp" ;
+.
+IBAL:Segment_7
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc3-OCP ;
+ s223:cnx IBAL:VAV_3_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 7" ;
+.
+IBAL:Segment_70
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc25-OCP1 ;
+ s223:cnx IBAL:PlateHeatExchange_2_Lower_ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 70" ;
+.
+IBAL:Segment_70_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "68" ;
+ rdfs:label "Segment_70_Temp" ;
+.
+IBAL:Segment_71
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc25-OCP2 ;
+ s223:cnx IBAL:Jnc26-ICP1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 71" ;
+.
+IBAL:Segment_73
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc27-ICP ;
+ s223:cnx IBAL:WaterPump_1_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 73" ;
+.
+IBAL:Segment_74
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc27-OCP1 ;
+ s223:cnx IBAL:ManualTwoWayValve_4_ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 74" ;
+.
+IBAL:Segment_75
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc26-ICP2 ;
+ s223:cnx IBAL:ManualTwoWayValve_4_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 75" ;
+.
+IBAL:Segment_76
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc26-OCP ;
+ s223:cnx IBAL:Jnc28-ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 76" ;
+.
+IBAL:Segment_76temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "75" ;
+ rdfs:label "Segment 76temp" ;
+.
+IBAL:Segment_77
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc28-OCP1 ;
+ s223:cnx IBAL:Jnc29-ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 77" ;
+.
+IBAL:Segment_78
+ a s223:Connection ;
+ s223:cnx IBAL:Chiller_1_Lower_ICP ;
+ s223:cnx IBAL:Jnc28-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 78" ;
+.
+IBAL:Segment_79
+ a s223:Connection ;
+ s223:cnx IBAL:Chiller_2_Lower_ICP ;
+ s223:cnx IBAL:Jnc29-OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 79" ;
+.
+IBAL:Segment_8
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc3-ICP2 ;
+ s223:cnx IBAL:Jnc4-OCP1 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 8" ;
+.
+IBAL:Segment_82
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc30-ICP ;
+ s223:cnx IBAL:WaterPump_3_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 82" ;
+.
+IBAL:Segment_83
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc31-ICP2 ;
+ s223:cnx IBAL:WaterPump_2_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 83" ;
+.
+IBAL:Segment_84
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc30-OCP ;
+ s223:cnx IBAL:Jnc31-ICP1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 84" ;
+.
+IBAL:Segment_85
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc31-OCP ;
+ s223:cnx IBAL:Jnc32-ICP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 85" ;
+.
+IBAL:Segment_86
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc27-OCP2 ;
+ s223:cnx IBAL:ManualTwoWayValve_5_ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 86" ;
+.
+IBAL:Segment_87
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc32-ICP1 ;
+ s223:cnx IBAL:ManualTwoWayValve_5_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 87" ;
+.
+IBAL:Segment_88
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc32-OCP ;
+ s223:cnx IBAL:Jnc33-ICP1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 88" ;
+.
+IBAL:Segment_88_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "62" ;
+ rdfs:label "Segment_88_Temp" ;
+.
+IBAL:Segment_89
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc33-OCP ;
+ s223:cnx IBAL:ThermalStorage_1_ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 89" ;
+.
+IBAL:Segment_9
+ a s223:Connection ;
+ s223:cnx IBAL:AHU_2_OCP ;
+ s223:cnx IBAL:Jnc4-ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "Segment 9" ;
+.
+IBAL:Segment_90
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc33-OCP2 ;
+ s223:cnx IBAL:MotorizedThreeWayValve_5_ICP_2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 90" ;
+.
+IBAL:Segment_92
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc34-ICP ;
+ s223:cnx IBAL:MotorizedThreeWayValve_5_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 92" ;
+.
+IBAL:Segment_92_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "67" ;
+ rdfs:label "Segment_92_Temp" ;
+.
+IBAL:Segment_93
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc34-OCP1 ;
+ s223:cnx IBAL:Jnc35-ICP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 93" ;
+.
+IBAL:Segment_94
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc34-OCP2 ;
+ s223:cnx IBAL:MotorizedThreeWayValve_4_ICP_2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 94" ;
+.
+IBAL:Segment_95
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc24-OCP2 ;
+ s223:cnx IBAL:Jnc35-ICP1 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 95" ;
+.
+IBAL:Segment_96
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc35-OCP ;
+ s223:cnx IBAL:WaterPump_4_ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 96" ;
+.
+IBAL:Segment_97
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc36-ICP ;
+ s223:cnx IBAL:WaterPump_4_OCP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 97" ;
+.
+IBAL:Segment_97_Temp
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "60" ;
+ rdfs:label "Segment_97_Temp" ;
+.
+IBAL:Segment_98
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc22-ICP ;
+ s223:cnx IBAL:Jnc36-OCP2 ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 98" ;
+.
+IBAL:Segment_99
+ a s223:Connection ;
+ s223:cnx IBAL:Jnc36-OCP1 ;
+ s223:cnx IBAL:Jnc37-ICP ;
+ s223:hasMedium s223:Water-GlycolSolution ;
+ rdfs:label "Segment 99" ;
+.
+IBAL:Temp_1
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:HC_1_ICP ;
+ s223:observes IBAL:HC-1-InletTemp ;
+ rdfs:label "Temp 1" ;
+.
+IBAL:Temp_14
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:VAV_3_Connection_2 ;
+ s223:observes IBAL:HC-5-OutletTemp ;
+ rdfs:label "Temp 14" ;
+.
+IBAL:Temp_15
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:HVAC_Space_3_ICP ;
+ s223:observes IBAL:HVACSpace-3-Temp ;
+ rdfs:label "Temp 15" ;
+.
+IBAL:Temp_16
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_16 ;
+ s223:observes IBAL:HVACSpace-3-OutletTemp ;
+ rdfs:label "Temp 16" ;
+.
+IBAL:Temp_18
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:HVAC_Space_4_ICP ;
+ s223:observes IBAL:HVACSpace-4-Temp ;
+ rdfs:label "Temp 18" ;
+.
+IBAL:Temp_19
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_14 ;
+ s223:observes IBAL:HVACSpace-2-OutletTemp ;
+ rdfs:label "Temp 19" ;
+.
+IBAL:Temp_2
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:AHU_1_Connection_2 ;
+ rdfs:label "Temp 2" ;
+.
+IBAL:Temp_20
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_18 ;
+ s223:observes IBAL:HVACSpace-4-OutletTemp ;
+ rdfs:label "Temp 20" ;
+.
+IBAL:Temp_21
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_27 ;
+ s223:observes IBAL:ExhaustFan-1-InletTemp ;
+ rdfs:label "Temp 21" ;
+.
+IBAL:Temp_22
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_30 ;
+ s223:observes IBAL:ExhaustFan-2-InletTemp ;
+ rdfs:label "Temp 22" ;
+.
+IBAL:Temp_23
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_52 ;
+ rdfs:label "Temp 23" ;
+.
+IBAL:Temp_24
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:AHU_3_Connection_2 ;
+ s223:observes IBAL:HC-7-InletTemp ;
+ rdfs:label "Temp 24" ;
+.
+IBAL:Temp_25
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:AHU_3_Connection_3 ;
+ s223:observes IBAL:VFD-5-InletTemp ;
+ rdfs:label "Temp 25" ;
+.
+IBAL:Temp_26
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_44 ;
+ s223:observes IBAL:VFD-5-OutletTemp ;
+ rdfs:label "Temp 26" ;
+.
+IBAL:Temp_3
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:AHU_1_Connection_3 ;
+ s223:observes IBAL:VFD-1-InletTemp ;
+ rdfs:label "Temp 3" ;
+.
+IBAL:Temp_5
+ a s223:TemperatureSensor ;
+ s223:observes IBAL:HC-2-OutletTemp ;
+ rdfs:label "Temp 5" ;
+.
+IBAL:Temp_6
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:HVAC_Space_1_ICP ;
+ s223:observes IBAL:HVACSpace-1-Temp ;
+ rdfs:label "Temp 6" ;
+.
+IBAL:Temp_7
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_12 ;
+ s223:observes IBAL:HVACSpace-1-OutletTemp ;
+ rdfs:label "Temp 7" ;
+.
+IBAL:Temp_8
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:VAV_2_Connection_2 ;
+ s223:observes IBAL:HC-3-OutletTemp ;
+ rdfs:label "Temp 8" ;
+.
+IBAL:Temp_9
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:HVAC_Space_2_ICP ;
+ s223:observes IBAL:HVACSpace-2-Temp ;
+ rdfs:label "Temp 9" ;
+.
+IBAL:ThermalStorage_1
+ a s223:Equipment ;
+ s223:hasConnectionPoint IBAL:ThermalStorage_1_ICP ;
+ s223:hasConnectionPoint IBAL:ThermalStorage_1_OCP ;
+.
+IBAL:ThermalStorage_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:cnx IBAL:Segment_89 ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Thermal Storage 1 ICP" ;
+.
+IBAL:ThermalStorage_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Water-ChilledWater ;
+ rdfs:label "Thermal Storage 1 OCP" ;
+.
+IBAL:VAV_1
+ a s223:TerminalUnit ;
+ s223:contains IBAL:HeatingCoil_2 ;
+ s223:contains IBAL:MotorizedDamper_1 ;
+ s223:hasConnectionPoint IBAL:VAV_1_ICP ;
+ s223:hasConnectionPoint IBAL:VAV_1_OCP ;
+ rdfs:label "VAV 1" ;
+.
+IBAL:VAV_1_Connection_1
+ a s223:Connection ;
+ s223:connectsAt IBAL:Damper_1_OCP ;
+ s223:connectsAt IBAL:HC_2_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 1 Connection 1" ;
+.
+IBAL:VAV_1_Connection_2
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_1_ICP ;
+ s223:cnx IBAL:VAV_1_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 1 Connection 2" ;
+.
+IBAL:VAV_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 1 ICP" ;
+.
+IBAL:VAV_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:VAV_1_Connection_2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 1 OCP" ;
+.
+IBAL:VAV_2
+ a s223:TerminalUnit ;
+ s223:contains IBAL:HeatingCoil_3 ;
+ s223:contains IBAL:MotorizedDamper_2 ;
+ s223:hasConnectionPoint IBAL:VAV_2_ICP ;
+ s223:hasConnectionPoint IBAL:VAV_2_OCP ;
+ rdfs:label "VAV 2" ;
+.
+IBAL:VAV_2_Connection_1
+ a s223:Connection ;
+ s223:connectsAt IBAL:Damper_2_OCP ;
+ s223:connectsAt IBAL:HC_3_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 2 Connection 1" ;
+.
+IBAL:VAV_2_Connection_2
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_2_ICP ;
+ s223:cnx IBAL:VAV_2_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 2 Connection 2" ;
+.
+IBAL:VAV_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 2 ICP" ;
+.
+IBAL:VAV_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 2 OCP" ;
+.
+IBAL:VAV_3
+ a s223:TerminalUnit ;
+ s223:contains IBAL:HeatingCoil_5 ;
+ s223:contains IBAL:MotorizedDamper_3 ;
+ s223:hasConnectionPoint IBAL:VAV_3_ICP ;
+ s223:hasConnectionPoint IBAL:VAV_3_OCP ;
+ rdfs:label "VAV 3" ;
+.
+IBAL:VAV_3_Connection_1
+ a s223:Connection ;
+ s223:connectsAt IBAL:Damper_3_OCP ;
+ s223:connectsAt IBAL:HC_5_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 3 Connection 1" ;
+.
+IBAL:VAV_3_Connection_2
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_3_ICP ;
+ s223:connectsAt IBAL:VAV_3_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 3 Connection 2" ;
+.
+IBAL:VAV_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 3 ICP" ;
+.
+IBAL:VAV_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 3 OCP" ;
+.
+IBAL:VAV_4
+ a s223:TerminalUnit ;
+ s223:contains IBAL:HeatingCoil_6 ;
+ s223:contains IBAL:MotorizedDamper_4 ;
+ s223:hasConnectionPoint IBAL:VAV_4_ICP ;
+ s223:hasConnectionPoint IBAL:VAV_4_OCP ;
+ rdfs:label "VAV 4" ;
+.
+IBAL:VAV_4_Connection_1
+ a s223:Connection ;
+ s223:connectsAt IBAL:Damper_4_OCP ;
+ s223:connectsAt IBAL:HC_6_ICP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 4 Connection 1" ;
+.
+IBAL:VAV_4_Connection_2
+ a s223:Connection ;
+ s223:cnx IBAL:HVAC_Space_4_ICP ;
+ s223:cnx IBAL:VAV_4_OCP ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 4 Connection 2" ;
+.
+IBAL:VAV_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 4 ICP" ;
+.
+IBAL:VAV_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:cnx IBAL:VAV_4_Connection_2 ;
+ s223:hasMedium s223:Medium-Air ;
+ rdfs:label "VAV 4 OCP" ;
+.
+IBAL:VFD-1-InletPressure
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "11297"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "11297" ;
+ rdfs:label "VFD 1 InletPressure" ;
+.
+IBAL:VFD-1-InletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "70"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "VFD 1 InletTemp" ;
+.
+IBAL:VFD-1-OutletHumidity
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "30"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "VFD 1 OutletHumidity" ;
+.
+IBAL:VFD-2-OutletPressure
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "11254"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "11254" ;
+ rdfs:label "VFD 2 OutletPressure" ;
+.
+IBAL:VFD-5-InletPressure
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "11297"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "11297" ;
+ rdfs:label "VFD 5 InletPressure" ;
+.
+IBAL:VFD-5-InletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "60"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "60" ;
+ rdfs:label "VFD 5 InletTemp" ;
+.
+IBAL:VFD-5-OutletHumidity
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "50" ;
+ rdfs:label "VFD 5 OutletHumidity" ;
+.
+IBAL:VFD-5-OutletPressure
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "11270"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "11270" ;
+ rdfs:label "VFD 5 OutletPressure" ;
+.
+IBAL:VFD-5-OutletTemp
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "45"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "45" ;
+ rdfs:label "VFD 5 OutletTemp" ;
+.
+IBAL:VFD_1
+ a s223:VariableFrequencyDrive ;
+ s223:hasConnectionPoint IBAL:VFD_1_ICP ;
+ s223:hasConnectionPoint IBAL:VFD_1_OCP ;
+ s223:hasProperty IBAL:ahu1_fan_power ;
+ rdfs:label "VFD 1" ;
+.
+IBAL:VFD_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 1 ICP" ;
+.
+IBAL:VFD_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Electricity-Signal ;
+ rdfs:label "VFD 1 OCP" ;
+.
+IBAL:VFD_2
+ a s223:VariableFrequencyDrive ;
+ s223:hasConnectionPoint IBAL:VFD_2_ICP ;
+ s223:hasConnectionPoint IBAL:VFD_2_OCP ;
+ s223:hasProperty IBAL:ahu1_vfd ;
+ rdfs:label "VFD 2" ;
+.
+IBAL:VFD_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 2 ICP" ;
+.
+IBAL:VFD_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 2 OCP" ;
+.
+IBAL:VFD_3
+ a s223:VariableFrequencyDrive ;
+ s223:connected IBAL:MotorizedDamper_10 ;
+ s223:hasConnectionPoint IBAL:VFD_3_ICP ;
+ s223:hasConnectionPoint IBAL:VFD_3_OCP ;
+ rdfs:label "VFD 3" ;
+.
+IBAL:VFD_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 3 ICP" ;
+.
+IBAL:VFD_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 3 OCP" ;
+.
+IBAL:VFD_4
+ a s223:VariableFrequencyDrive ;
+ s223:hasConnectionPoint IBAL:VFD_4_ICP ;
+ s223:hasConnectionPoint IBAL:VFD_4_OCP ;
+ rdfs:label "VFD 4" ;
+.
+IBAL:VFD_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 4 ICP" ;
+.
+IBAL:VFD_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 4 OCP" ;
+.
+IBAL:VFD_5
+ a s223:VariableFrequencyDrive ;
+ s223:hasConnectionPoint IBAL:VFD_5_ICP ;
+ s223:hasConnectionPoint IBAL:VFD_5_OCP ;
+ rdfs:label "VFD 5" ;
+.
+IBAL:VFD_5_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 5 ICP" ;
+.
+IBAL:VFD_5_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Electricity ;
+ rdfs:label "VFD 5 OCP" ;
+.
+IBAL:WaterChiller_1
+ a s223:Chiller ;
+ s223:hasConnectionPoint IBAL:Chiller_1_Lower_ICP ;
+ s223:hasConnectionPoint IBAL:Chiller_1_Lower_OCP ;
+ s223:hasConnectionPoint IBAL:Chiller_1_Upper_ICP ;
+ s223:hasConnectionPoint IBAL:Chiller_1_Upper_OCP ;
+ rdfs:label "Water Chiller 1" ;
+.
+IBAL:WaterChiller_2
+ a s223:Chiller ;
+ s223:hasConnectionPoint IBAL:Chiller_2_Lower_ICP ;
+ s223:hasConnectionPoint IBAL:Chiller_2_Lower_OCP ;
+ s223:hasConnectionPoint IBAL:Chiller_2_Upper_ICP ;
+ s223:hasConnectionPoint IBAL:Chiller_2_Upper_OCP ;
+ rdfs:label "Water Chiller 2" ;
+.
+IBAL:WaterPump_1
+ a s223:Pump ;
+ s223:hasConnectionPoint IBAL:WaterPump_1_ICP ;
+ s223:hasConnectionPoint IBAL:WaterPump_1_OCP ;
+ rdfs:label "Water pump 1" ;
+.
+IBAL:WaterPump_1_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 1 ICP" ;
+.
+IBAL:WaterPump_1_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 1 OCP" ;
+.
+IBAL:WaterPump_2
+ a s223:Pump ;
+ s223:hasConnectionPoint IBAL:WaterPump_2_ICP ;
+ s223:hasConnectionPoint IBAL:WaterPump_2_OCP ;
+ rdfs:label "Water pump 2" ;
+.
+IBAL:WaterPump_2_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 2 ICP" ;
+.
+IBAL:WaterPump_2_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 2 OCP" ;
+.
+IBAL:WaterPump_3
+ a s223:Pump ;
+ s223:hasConnectionPoint IBAL:WaterPump_3_ICP ;
+ s223:hasConnectionPoint IBAL:WaterPump_3_OCP ;
+ rdfs:label "Water pump 3" ;
+.
+IBAL:WaterPump_3_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 3 ICP" ;
+.
+IBAL:WaterPump_3_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 3 OCP" ;
+.
+IBAL:WaterPump_4
+ a s223:Pump ;
+ s223:hasConnectionPoint IBAL:WaterPump_4_ICP ;
+ s223:hasConnectionPoint IBAL:WaterPump_4_OCP ;
+ rdfs:label "Water pump 4" ;
+.
+IBAL:WaterPump_4_ICP
+ a s223:InletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 4 ICP" ;
+.
+IBAL:WaterPump_4_OCP
+ a s223:OutletConnectionPoint ;
+ s223:hasMedium s223:Medium-Water ;
+ rdfs:label "Water pump 4 OCP" ;
+.
+IBAL:WaterTempSensor
+ a s223:Class ;
+ a sh:NodeShape ;
+ rdfs:label "Water Temperature Sensor" ;
+ rdfs:subClassOf s223:Sensor ;
+.
+IBAL:WaterTempSensor_10
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Chiller_2_Lower_Connection ;
+ rdfs:label "Water Temp Sensor 10" ;
+.
+IBAL:WaterTempSensor_11
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_88 ;
+ s223:observes IBAL:Segment_88_Temp ;
+ rdfs:label "Water Temp Sensor 11" ;
+.
+IBAL:WaterTempSensor_12
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_92 ;
+ s223:observes IBAL:Segment_92_Temp ;
+ rdfs:label "Water Temp Sensor 12" ;
+.
+IBAL:WaterTempSensor_13
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_97 ;
+ s223:observes IBAL:Segment_97_Temp ;
+ rdfs:label "Water Temp Sensor 13" ;
+.
+IBAL:WaterTempSensor_3
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:PlateHeatExchange_1_Connection ;
+ s223:observes IBAL:PlateHeatExchange_1_Connection_Temp ;
+ rdfs:label "Water Temp Sensor 3" ;
+.
+IBAL:WaterTempSensor_4
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_67 ;
+ s223:observes IBAL:Segment_67_Temp ;
+ rdfs:label "Water Temp Sensor 4" ;
+.
+IBAL:WaterTempSensor_5
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_69 ;
+ s223:observes IBAL:Segment_69_Temp ;
+ rdfs:label "Water Temp Sensor 5" ;
+.
+IBAL:WaterTempSensor_6
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_70 ;
+ s223:observes IBAL:Segment_70_Temp ;
+ rdfs:label "Water Temp Sensor 6" ;
+.
+IBAL:WaterTempSensor_7
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:HeatExchange_Connection ;
+ s223:observes IBAL:HeatExchange_Connection_Temp ;
+ rdfs:label "Water Temp Sensor 7" ;
+.
+IBAL:WaterTempSensor_8
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Segment_76 ;
+ s223:observes IBAL:Segment_76temp ;
+ rdfs:label "Water Temp Sensor 8" ;
+.
+IBAL:WaterTempSensor_9
+ a s223:TemperatureSensor ;
+ s223:hasObservationLocation IBAL:Chiller_1_Lower_Connection ;
+ rdfs:label "Water Temp Sensor 9" ;
+.
+IBAL:ahu1_cc_out_rtd
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU1 CC Out RTD" ;
+.
+IBAL:ahu1_cc_rtd
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "45"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU 1 CC RTD" ;
+.
+IBAL:ahu1_f_cc
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "40"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "40" ;
+ rdfs:label "Channel 197" ;
+.
+IBAL:ahu1_f_ra
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "1000"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "1000" ;
+ rdfs:label "AHU 1 F RA" ;
+.
+IBAL:ahu1_f_sa
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "600"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "600" ;
+ rdfs:label "AHU 1 F SA" ;
+.
+IBAL:ahu1_fan_power
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU1 Fan Power" ;
+.
+IBAL:ahu1_heat_c
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU1 Heat C" ;
+.
+IBAL:ahu1_heat_power
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU1 Heat Power" ;
+.
+IBAL:ahu1_heat_rtd
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU 1 Heat RTD" ;
+.
+IBAL:ahu1_in_rtd
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "45"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU 1 In RTD" ;
+.
+IBAL:ahu1_on
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "ahu1 on" ;
+.
+IBAL:ahu1_out_rtd
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "70"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "70" ;
+ rdfs:label "AHU 1 Out RTD" ;
+.
+IBAL:ahu1_p_down
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "11297"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "11297" ;
+ rdfs:label "AHU 1 P Down" ;
+.
+IBAL:ahu1_p_up
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "11296"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "11296" ;
+ rdfs:label "AHU1 P Up" ;
+.
+IBAL:ahu1_rh_down
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "50"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "50" ;
+ rdfs:label "AHU 1 RH Down" ;
+.
+IBAL:ahu1_rh_up
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "60"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ qudt:value "60" ;
+ rdfs:label "AHU 1 RH Up" ;
+.
+IBAL:ahu1_t_ra
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "65"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU 1 T RA" ;
+.
+IBAL:ahu1_t_sa
+ a s223:QuantifiableObservableProperty ;
+ s223:hasValue "60"^^xsd:decimal ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "AHU 1 T SA" ;
+.
+IBAL:ahu1_vfd
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "ahu1 vfd" ;
+.
+IBAL:d5_pos_c
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ rdfs:label "d5 pos c" ;
+.
+IBAL:d5_pos_fb
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ rdfs:label "d5 pos fb" ;
+.
+IBAL:d6_pos_c
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ rdfs:label "d6 pos c" ;
+.
+IBAL:d6_pos_fb
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ rdfs:label "d6 pos fb" ;
+.
+IBAL:v12_pos_c
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "v12 pos c" ;
+.
+IBAL:v12_pos_fb
+ a s223:QuantifiableObservableProperty ;
+ qudt:hasQuantityKind ;
+ qudt:hasUnit ;
+ rdfs:label "v12 pos fb" ;
+.
diff --git a/models/lbnl-example.jsonld b/models/lbnl-example.jsonld
index 555cde57..060f3b68 100644
--- a/models/lbnl-example.jsonld
+++ b/models/lbnl-example.jsonld
@@ -1,120 +1,57 @@
[
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-521-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-521-reheat-coil-valve-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-521-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-538-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-538-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-506-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-521-reheat-coil-valve-command"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-521-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-in",
+ "@id": "urn:ex/vav-524-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-523-hot-water-in"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-504-damper-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-504-damper"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "@id": "urn:ex/vav-524-damper-in"
+ },
{
- "@id": "urn:ex/vav-504-damper-command"
+ "@id": "urn:ex/vav-524-damper-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-103-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-302-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-524-damper-command"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-524-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-temp",
+ "@id": "urn:ex/vav-522-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -135,108 +72,96 @@
]
},
{
- "@id": "urn:ex/office-ahu-sa-flow-sensor",
+ "@id": "urn:ex/office-ahu-oa-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-sa-fan-in"
+ "@id": "urn:ex/office-ahu-oa-damper-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-sa-flow"
+ "@id": "urn:ex/office-ahu-oa-temp"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-air-in",
+ "@id": "urn:ex/zone-313-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-535-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil",
+ "@id": "urn:ex/vav-532-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-reheat-coil-air-in"
- },
+ "@id": "urn:ex/connection-to-room-309-310"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-522-reheat-coil-air-out"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-522-reheat-coil-water-in"
+ "@id": "urn:ex/vav-532-heating-pid-output"
},
{
- "@id": "urn:ex/vav-522-reheat-coil-water-out"
+ "@id": "urn:ex/vav-532-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-532-air-out"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-temp-sensor",
+ "@id": "urn:ex/zone-206-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/office-ahu-ra-in"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-ra-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-521-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-out",
+ "@id": "urn:ex/vav-506-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-106-107"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -246,63 +171,60 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-534-colder-supply-air-requests"
+ "@id": "urn:ex/vav-506-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-534-cooling-pid-output"
+ "@id": "urn:ex/vav-506-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-506-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-506-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-water-out",
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-210-in",
+ "@id": "urn:ex/vav-517-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-210"
+ "@id": "urn:ex/vav-517-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-517-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-position",
+ "@id": "urn:ex/office-ahu-warmer-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-534-cooling-pid-output",
+ "@id": "urn:ex/vav-523-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -318,46 +240,57 @@
]
},
{
- "@id": "urn:ex/connection-to-room-110",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#EnumerationKind"
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp",
+ "@id": "urn:ex/vav-538-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-309-310-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-out",
+ "@id": "urn:ex/vav-514-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-536-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-313"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -367,94 +300,113 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-523-colder-supply-air-requests"
+ "@id": "urn:ex/vav-536-heating-pid-output"
},
{
- "@id": "urn:ex/vav-523-cooling-pid-output"
+ "@id": "urn:ex/vav-536-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-536-air-out"
}
]
},
{
- "@id": "urn:ex/vav-517-more-heat-requests",
+ "@id": "urn:ex/zone-210-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-503-colder-supply-air-requests",
+ "@id": "urn:ex/zone-207-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-207-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-207-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-position",
+ "@id": "urn:ex/room-103-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-103"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-530-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-308-hvac-domain",
+ "@id": "urn:ex/room-310-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-308-in"
- },
- {
- "@id": "urn:ex/room-308-out"
+ "@id": "urn:ex/connection-to-room-309-310"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-502-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-502-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -464,67 +416,55 @@
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve",
+ "@id": "urn:ex/vav-524-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-509-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-524-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-509-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-509-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-503-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-204-out",
+ "@id": "urn:ex/room-309-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -540,97 +480,101 @@
]
},
{
- "@id": "urn:ex/connection-to-room-103",
+ "@id": "urn:ex/zone-215-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-215-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-215-temp"
}
]
},
{
- "@id": "urn:ex/zone-106-107-window-switch-on-off",
+ "@id": "urn:ex/vav-538-air-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-air-out",
+ "@id": "urn:ex/vav-510-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-103"
+ "@id": "urn:ex/vav-510-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-513-heating-pid-output"
+ "@id": "urn:ex/vav-510-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-513-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-513-air-out"
+ "@id": "urn:ex/vav-510-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-108-occupancy-sensor",
+ "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-108-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-108-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-damper-actuator",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-525-damper-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-water-in",
+ "@id": "urn:ex/vav-510-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-hot-water-in-connection"
+ "@id": "urn:ex/vav-510-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -640,176 +584,191 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-535-hot-water-in"
+ "@id": "urn:ex/vav-510-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-522-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve"
+ "@id": "urn:ex/vav-522-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-522-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-110-cooling-setpoint",
+ "@id": "urn:ex/vav-513-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-out",
+ "@id": "urn:ex/vav-530-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-504-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-504-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-504-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-501-air-out",
+ "@id": "urn:ex/vav-509-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-102"
+ "@id": "urn:ex/vav-509-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-501-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-501-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-501-discharge-air-temp"
+ "@id": "urn:ex/vav-509-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-509-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve",
+ "@id": "urn:ex/vav-502-damper",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-502-damper-in"
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-502-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-502-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-502-damper-position"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-104-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve",
+ "@id": "urn:ex/vav-510-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-529-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-510-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-actuator",
+ "@id": "urn:ex/vav-505-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-510-damper"
+ "@id": "urn:ex/vav-505-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-510-damper-command"
+ "@id": "urn:ex/vav-505-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-water-in",
+ "@id": "urn:ex/vav-504-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-hot-water-in-connection"
+ "@id": "urn:ex/vav-504-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -819,173 +778,157 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-519-hot-water-in"
+ "@id": "urn:ex/vav-504-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-110-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-519-hot-water-in-connection",
+ "@id": "urn:ex/vav-529-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-529-damper"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-102",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-529-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-air-in",
+ "@id": "urn:ex/vav-532-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-505-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-535-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-535-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-535-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-535-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-air-in",
+ "@id": "urn:ex/vav-513-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-duct-after-damper"
+ "@id": "urn:ex/vav-513-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-513-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-535-damper-out",
+ "@id": "urn:ex/room-207-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-207"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-535-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-535-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/vav-512-colder-supply-air-requests",
+ "@id": "urn:ex/zone-307-308-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-307-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-307-308-temp"
}
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-210-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-537-air-out"
+ "@id": "urn:ex/room-210-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-537-discharge-air-temp"
+ "@id": "urn:ex/zone-210-temp"
}
]
},
{
- "@id": "urn:ex/zone-312-occupancy",
+ "@id": "urn:ex/connection-to-room-307-308",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-207-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -996,29 +939,53 @@
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-540-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-206-in",
+ "@id": "urn:ex/connection-to-room-118",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-116-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-206"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1028,210 +995,209 @@
]
},
{
- "@id": "urn:ex/zone-118-temp",
+ "@id": "urn:ex/vav-515-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-start-status",
+ "@id": "urn:ex/vav-525-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/room-110-out",
+ "@id": "urn:ex/zone-204-205-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-311-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-106-107-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/room-106-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-106-107-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-513-air-out",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-103"
+ "@id": "urn:ex/vav-529-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-513-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-513-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-513-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-513-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-529-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-flow",
+ "@id": "urn:ex/vav-532-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-537-hot-water-out",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-hot-water-out-connection"
+ "@id": "urn:ex/vav-534-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-534-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-303-304-306-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-534-air-in"
+ "@id": "urn:ex/room-303-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-534-discharge-air-flow"
+ "@id": "urn:ex/zone-303-304-306-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-in",
+ "@id": "urn:ex/vav-540-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-540-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-532-air-in"
+ "@id": "urn:ex/vav-540-hot-water-in"
}
]
},
{
- "@id": "urn:ex/connection-to-room-302",
+ "@id": "urn:ex/vav-529-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-529-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-529-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-air-in",
+ "@id": "urn:ex/zone-115-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-519-duct-after-damper",
+ "@id": "urn:ex/office-ahu-duct-after-clg-coil",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -1243,128 +1209,115 @@
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-203-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-527-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-527-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-504-hot-water-out",
+ "@id": "urn:ex/zone-302-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-504-hot-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-actuator",
+ "@id": "urn:ex/vav-522-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-526-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-526-damper-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-start-cmd",
+ "@id": "urn:ex/vav-501-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/zone-312-occupancy-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-312-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-312-occupancy"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-309-310-occupancy-sensor",
+ "@id": "urn:ex/vav-506-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-309-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-309-310-occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-113-hvac-domain",
+ "@id": "urn:ex/zone-305-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-113-in"
- },
- {
- "@id": "urn:ex/room-113-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-525-air-in",
+ "@id": "urn:ex/room-110-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-110"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1374,244 +1327,231 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve",
+ "@id": "urn:ex/vav-527-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-527-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-command"
- },
+ "@id": "urn:ex/vav-537-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-537-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-212-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-212-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-212-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-214-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-actuator",
+ "@id": "urn:ex/vav-530-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-513-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-513-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-531-hot-water-in-connection",
+ "@id": "urn:ex/zone-113-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-hot-water-out-connection"
+ "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-537-hot-water-out"
- }
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-air-out",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-215"
+ "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-540-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-540-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-air-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-102-occupancy-sensor",
+ "@id": "urn:ex/vav-521-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-102-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-102-occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-in",
+ "@id": "urn:ex/room-206-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-521-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-water-out",
+ "@id": "urn:ex/vav-504-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-105"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-504-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-504-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-504-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-504-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/room-211-in",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-211"
+ "@id": "urn:ex/vav-503-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-502-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-503-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-509-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-527-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-509-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1620,245 +1560,227 @@
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-202-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-air-in"
+ "@id": "urn:ex/connection-to-room-202"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-507-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-508-air-in",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-527-damper",
+ "@id": "urn:ex/vav-531-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-damper-in"
- },
- {
- "@id": "urn:ex/vav-527-damper-out"
+ "@id": "urn:ex/vav-531-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-527-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-527-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-502-hot-water-in",
+ "@id": "urn:ex/vav-520-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-502-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-air-filter",
+ "@id": "urn:ex/vav-520-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-out",
+ "@id": "urn:ex/office-ahu-oa-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-duct-after-damper"
+ "@id": "urn:ex/office-ahu-oa-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-536-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-536-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Fan",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-sa-fan-in"
- },
- {
- "@id": "urn:ex/office-ahu-sa-fan-out"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-sa-fan-power"
- },
- {
- "@id": "urn:ex/office-ahu-sa-fan-speed-cmd"
- },
- {
- "@id": "urn:ex/office-ahu-sa-fan-speed-status"
- },
- {
- "@id": "urn:ex/office-ahu-sa-fan-start-cmd"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-sa-fan-start-status"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-111-out",
+ "@id": "urn:ex/vav-527-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-air-in",
+ "@id": "urn:ex/zone-207-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-513-duct-after-damper"
+ "@id": "urn:ex/room-207-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-207-temp"
}
]
},
{
- "@id": "urn:ex/vav-534-duct-after-damper",
+ "@id": "urn:ex/vav-502-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-101"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-502-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-502-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-502-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-502-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-510-heating-pid-output",
+ "@id": "urn:ex/vav-528-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-533-duct-after-damper",
+ "@id": "urn:ex/vav-520-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-520-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-520-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-508-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-508-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1868,96 +1790,102 @@
]
},
{
- "@id": "urn:ex/zone-314-occupancy-override",
+ "@id": "urn:ex/zone-103",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/room-103-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/zone-101-co2-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-101-co2-concentration"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-518-reheat-coil-valve-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/zone-103-cooling-setpoint"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/zone-103-heating-setpoint"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-103-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-103-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-103-temp"
+ },
+ {
+ "@id": "urn:ex/zone-103-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-110-temp",
+ "@id": "urn:ex/vav-525",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-525-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-525-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-525-damper"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-537-damper",
+ "@id": "urn:ex/vav-528-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-damper-in"
+ "@id": "urn:ex/vav-528-damper-in"
},
{
- "@id": "urn:ex/vav-537-damper-out"
+ "@id": "urn:ex/vav-528-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-537-damper-command"
+ "@id": "urn:ex/vav-528-damper-command"
},
{
- "@id": "urn:ex/vav-537-damper-position"
+ "@id": "urn:ex/vav-528-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-water-out",
+ "@id": "urn:ex/vav-521-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1966,201 +1894,141 @@
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-command",
+ "@id": "urn:ex/room-102-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-210-temp",
+ "@id": "urn:ex/vav-524-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-524-reheat-coil-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/room-203-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-524-reheat-coil-air-out"
+ },
{
- "@id": "urn:ex/connection-to-room-203"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-524-reheat-coil-water-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-524-reheat-coil-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-503-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-111",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-111-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/room-311-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/connection-to-room-311"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/zone-111-cooling-setpoint"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-204-205-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/zone-111-heating-setpoint"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-529-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/zone-111-occupancy"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-523-hot-water-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/zone-111-occupancy-override"
+ },
{
- "@id": "urn:ex/vav-523-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/zone-111-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-111-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-538-cooling-pid-output",
+ "@id": "urn:ex/zone-105-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-water-out",
+ "@id": "urn:ex/zone-116-117-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-519",
+ "@id": "urn:ex/vav-533-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-air-in"
- },
- {
- "@id": "urn:ex/vav-519-air-out"
- },
- {
- "@id": "urn:ex/vav-519-hot-water-in"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-519-hot-water-out"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-damper"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-519-reheat-coil"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-511-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -2172,9 +2040,9 @@
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -2188,29 +2056,50 @@
]
},
{
- "@id": "urn:ex/zone-213-temp-sensor",
+ "@id": "urn:ex/vav-534-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-213-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-213-temp"
+ "@id": "urn:ex/vav-530-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-air-out",
+ "@id": "urn:ex/vav-540-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-106-107"
+ "@id": "urn:ex/connection-to-room-215"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2220,126 +2109,100 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-506-heating-pid-output"
+ "@id": "urn:ex/vav-540-heating-pid-output"
},
{
- "@id": "urn:ex/vav-506-more-heat-requests"
+ "@id": "urn:ex/vav-540-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-506-air-out"
+ "@id": "urn:ex/vav-540-air-out"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-command",
+ "@id": "urn:ex/vav-535-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-109-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve",
+ "@id": "urn:ex/office-ahu-air-filter-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil-valve-out"
+ "@id": "urn:ex/office-ahu-duct-after-air-filter"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-533-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-540",
+ "@id": "urn:ex/zone-202-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-540-air-in"
- },
- {
- "@id": "urn:ex/vav-540-air-out"
- },
- {
- "@id": "urn:ex/vav-540-hot-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-540-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-540-damper"
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-505-air-out",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-108"
+ "@id": "urn:ex/vav-525-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-505-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-505-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-505-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-505-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-525-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-536-duct-after-damper",
+ "@id": "urn:ex/vav-515-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -2351,80 +2214,66 @@
]
},
{
- "@id": "urn:ex/zone-111-occupancy-override",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/office-ahu-chilled-water-out-connection"
}
- ]
- },
- {
- "@id": "urn:ex/zone-309-310",
- "@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-309-hvac-domain"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-310-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/office-ahu-chilled-water-out"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-204-205-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-309-310-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-309-310-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-309-310-occupancy"
- },
- {
- "@id": "urn:ex/zone-309-310-occupancy-override"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/zone-309-310-temp"
- },
+ "@id": "urn:ex/room-204-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-309-310-window-switch-on-off"
+ "@id": "urn:ex/zone-204-205-temp"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-118-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-538-air-out"
+ "@id": "urn:ex/room-118-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-538-discharge-air-temp"
+ "@id": "urn:ex/zone-118-temp"
}
]
},
{
- "@id": "urn:ex/room-304-in",
+ "@id": "urn:ex/room-308-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2434,13 +2283,13 @@
]
},
{
- "@id": "urn:ex/vav-511-air-out",
+ "@id": "urn:ex/vav-536-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-112-114"
+ "@id": "urn:ex/connection-to-room-313"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2450,77 +2299,54 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-discharge-air-flow"
+ "@id": "urn:ex/vav-536-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-511-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-536-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-511-discharge-air-temp"
+ "@id": "urn:ex/vav-536-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-511-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-536-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-flow",
+ "@id": "urn:ex/zone-215-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-air-out",
+ "@id": "urn:ex/vav-507-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-208-209"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-522-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-522-more-heat-requests"
+ "@id": "urn:ex/vav-507-air-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-522-air-out"
+ "@id": "urn:ex/vav-507-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-air-out",
+ "@id": "urn:ex/vav-524-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-113"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2528,67 +2354,44 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-509-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-509-more-heat-requests"
- }
- ],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-509-air-out"
+ "@id": "urn:ex/vav-524-air-in"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve",
+ "@id": "urn:ex/vav-518-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-518-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-518-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-207-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-518-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-out",
+ "@id": "urn:ex/vav-501-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ea-out-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2598,28 +2401,38 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/office-ahu-ea-out"
+ "@id": "urn:ex/vav-501-air-in"
}
]
},
{
- "@id": "urn:ex/vav-503-hot-water-out",
+ "@id": "urn:ex/vav-513-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-hot-water-out-connection"
+ "@id": "urn:ex/vav-513-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-command",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -2635,226 +2448,177 @@
]
},
{
- "@id": "urn:ex/office-ahu-sa-out",
+ "@id": "urn:ex/vav-502-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-colder-supply-air-requests"
+ "@id": "urn:ex/vav-502-reheat-coil-air-in"
},
{
- "@id": "urn:ex/office-ahu-increased-air-pressure-requests"
+ "@id": "urn:ex/vav-502-reheat-coil-air-out"
},
{
- "@id": "urn:ex/office-ahu-sa-temp"
+ "@id": "urn:ex/vav-502-reheat-coil-water-in"
},
{
- "@id": "urn:ex/office-ahu-sa-temp-setpoint"
- },
+ "@id": "urn:ex/vav-502-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
- },
- {
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint"
- },
- {
- "@id": "urn:ex/office-ahu-warmer-supply-air-requests"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-508-damper-out",
+ "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-chilled-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-508-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-508-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-damper-in",
+ "@id": "urn:ex/vav-517-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-517-reheat-coil-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-517-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-518-air-in"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-527-heating-pid-output",
+ "@id": "urn:ex/vav-511-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-214-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-314-temp-sensor",
+ "@id": "urn:ex/zone-104-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-314-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-flow",
+ "@id": "urn:ex/vav-532-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-532-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-532-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-501",
+ "@id": "urn:ex/vav-510-air-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-air-in"
- },
- {
- "@id": "urn:ex/vav-501-air-out"
- },
- {
- "@id": "urn:ex/vav-501-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-501-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-501-damper"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/vav-511-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-113-in",
+ "@id": "urn:ex/vav-519-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-113"
+ "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-flow",
+ "@id": "urn:ex/vav-532-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -2868,95 +2632,113 @@
]
},
{
- "@id": "urn:ex/vav-534-more-heat-requests",
+ "@id": "urn:ex/zone-104-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-102-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-514-air-in"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-514-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-522-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve"
+ "@id": "urn:ex/vav-522-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-516-colder-supply-air-requests",
+ "@id": "urn:ex/vav-537-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-537-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-537-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-537-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-521-hot-water-out-connection",
+ "@id": "urn:ex/connection-to-room-104",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-302-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-air-in"
+ "@id": "urn:ex/connection-to-room-302"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-512-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-air-out",
+ "@id": "urn:ex/vav-522-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2964,23 +2746,14 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-521-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-521-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-521-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-522-air-in"
}
]
},
{
- "@id": "urn:ex/vav-533-colder-supply-air-requests",
+ "@id": "urn:ex/vav-516-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -2991,173 +2764,143 @@
]
},
{
- "@id": "urn:ex/zone-305-heating-setpoint",
+ "@id": "urn:ex/zone-110",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-110-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-528-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-508-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/zone-110-cooling-setpoint"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-519-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/zone-110-heating-setpoint"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/zone-110-occupancy"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-110-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-110-temp"
+ },
+ {
+ "@id": "urn:ex/zone-110-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-water-out",
+ "@id": "urn:ex/vav-502-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-502-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-305",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-502-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-536-heating-pid-output",
+ "@id": "urn:ex/vav-536-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-536-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-530-damper",
+ "@id": "urn:ex/vav-523-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-damper-in"
+ "@id": "urn:ex/vav-523-damper-in"
},
{
- "@id": "urn:ex/vav-530-damper-out"
+ "@id": "urn:ex/vav-523-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-530-damper-command"
+ "@id": "urn:ex/vav-523-damper-command"
},
{
- "@id": "urn:ex/vav-530-damper-position"
+ "@id": "urn:ex/vav-523-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-513-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-actuator",
+ "@id": "urn:ex/room-113-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve"
+ "@id": "urn:ex/connection-to-room-113"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper",
+ "@id": "urn:ex/room-201-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-201"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3166,23 +2909,30 @@
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-521-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-521-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-521-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-521-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-103-cooling-setpoint",
+ "@id": "urn:ex/zone-111-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -3198,39 +2948,55 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-532",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve"
+ "@id": "urn:ex/vav-532-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-532-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-532-damper"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-oa-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-537-hot-water-in-connection",
+ "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -3242,81 +3008,85 @@
]
},
{
- "@id": "urn:ex/zone-301",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-301-hvac-domain"
+ "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-301-cooling-setpoint"
- },
+ "@id": "urn:ex/connection-to-room-311"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-301-heating-setpoint"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-301-occupancy"
+ "@id": "urn:ex/vav-535-discharge-air-flow"
},
{
- "@id": "urn:ex/zone-301-occupancy-override"
+ "@id": "urn:ex/vav-535-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/zone-301-temp"
+ "@id": "urn:ex/vav-535-discharge-air-temp"
},
{
- "@id": "urn:ex/zone-301-window-switch-on-off"
+ "@id": "urn:ex/vav-535-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-118",
+ "@id": "urn:ex/vav-512-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-118-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-118-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-118-occupancy"
- },
- {
- "@id": "urn:ex/zone-118-occupancy-override"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-118-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-118-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-temp",
+ "@id": "urn:ex/vav-517-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -3327,79 +3097,93 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve",
+ "@id": "urn:ex/vav-512-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-in"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-valve-out"
+ "@id": "urn:ex/connection-to-room-118"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-command"
+ "@id": "urn:ex/vav-512-heating-pid-output"
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-position"
+ "@id": "urn:ex/vav-512-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-512-air-out"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-actuator",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-507-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-air-out"
+ "@id": "urn:ex/connection-to-room-110"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-507-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-507-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-507-air-out"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-position",
+ "@id": "urn:ex/vav-534-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -3413,7 +3197,30 @@
]
},
{
- "@id": "urn:ex/vav-519-damper-command",
+ "@id": "urn:ex/vav-508-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-508-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-508-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-508-damper-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -3429,19 +3236,35 @@
]
},
{
- "@id": "urn:ex/vav-539-hot-water-in-connection",
+ "@id": "urn:ex/connection-to-room-115",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-position",
+ "@id": "urn:ex/vav-536-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-536-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-536-discharge-air-flow"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -3457,30 +3280,25 @@
]
},
{
- "@id": "urn:ex/zone-115-occupancy-sensor",
+ "@id": "urn:ex/zone-111-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "urn:ex/room-111-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-115-occupancy"
+ "@id": "urn:ex/zone-111-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp",
+ "@id": "urn:ex/zone-116-117-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -3494,104 +3312,118 @@
]
},
{
- "@id": "urn:ex/zone-314",
+ "@id": "urn:ex/vav-538-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-536-reheat-coil-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-314-cooling-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-314-heating-setpoint"
+ "@id": "urn:ex/vav-536-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/zone-314-occupancy"
- },
+ "@id": "urn:ex/vav-536-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-314-occupancy-override"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-314-temp"
+ "@id": "urn:ex/vav-536-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/zone-314-window-switch-on-off"
+ "@id": "urn:ex/vav-536-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil",
+ "@id": "urn:ex/vav-523-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-533-reheat-coil-air-in"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-533-reheat-coil-air-out"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-533-reheat-coil-water-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-533-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-water-out",
+ "@id": "urn:ex/vav-509-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-509-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-509-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-515-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-504-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -3605,228 +3437,186 @@
]
},
{
- "@id": "urn:ex/vav-539-air-out",
+ "@id": "urn:ex/vav-520-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-214"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-539-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-539-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-539-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-539-discharge-air-temp-setpoint"
- }
]
},
{
- "@id": "urn:ex/zone-206-co2-concentration-setpoint",
+ "@id": "urn:ex/vav-529-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#ofSubstance": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-205-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-water-in",
+ "@id": "urn:ex/vav-534-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-hot-water-in-connection"
+ "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/office-ahu-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve",
+ "@id": "urn:ex/office-ahu-oa-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-521-reheat-coil-valve-out"
+ "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-command"
+ "@id": "urn:ex/office-ahu-oa-flow"
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/office-ahu-ea-damper-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/office-ahu-oa-temp"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-flow",
+ "@id": "urn:ex/room-215-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/connection-to-room-215"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-526",
+ "@id": "urn:ex/vav-515",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-air-in"
+ "@id": "urn:ex/vav-515-air-in"
},
{
- "@id": "urn:ex/vav-526-air-out"
+ "@id": "urn:ex/vav-515-air-out"
},
{
- "@id": "urn:ex/vav-526-hot-water-in"
+ "@id": "urn:ex/vav-515-hot-water-in"
},
{
- "@id": "urn:ex/vav-526-hot-water-out"
+ "@id": "urn:ex/vav-515-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-526-damper"
+ "@id": "urn:ex/vav-515-damper"
},
{
- "@id": "urn:ex/vav-526-reheat-coil"
+ "@id": "urn:ex/vav-515-reheat-coil"
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve"
+ "@id": "urn:ex/vav-515-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-out",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-duct-after-damper"
+ "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-520-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-520-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/connection-to-room-112-114",
+ "@id": "urn:ex/zone-110-temp",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-513-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-535-air-in"
+ "@id": "urn:ex/vav-513-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-535-discharge-air-flow"
+ "@id": "urn:ex/vav-513-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-513-air-in",
+ "@id": "urn:ex/vav-508-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -3839,33 +3629,18 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-538-hot-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-538-hot-water-out-connection"
- }
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-508-air-in"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-air-in",
+ "@id": "urn:ex/vav-523-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-516-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3874,101 +3649,119 @@
]
},
{
- "@id": "urn:ex/office-ahu-oa-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/office-ahu-oa-damper-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/office-ahu-oa-temp"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-504-more-heat-requests",
+ "@id": "urn:ex/room-201",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-201-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-out",
+ "@id": "urn:ex/vav-528",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-528-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-528-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-528-damper"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-510-air-out",
+ "@id": "urn:ex/zone-115",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-111"
+ "@id": "urn:ex/room-115-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-510-discharge-air-flow"
+ "@id": "urn:ex/zone-115-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-510-discharge-air-flow-setpoint"
+ "@id": "urn:ex/zone-115-heating-setpoint"
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp"
+ "@id": "urn:ex/zone-115-occupancy"
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp-setpoint"
+ "@id": "urn:ex/zone-115-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-115-temp"
+ },
+ {
+ "@id": "urn:ex/zone-115-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-flow",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518-hot-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-518-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-511-duct-after-damper",
+ "@id": "urn:ex/vav-537-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -3980,25 +3773,51 @@
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-517-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-air-in"
+ "@id": "urn:ex/vav-517-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-517-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-103-heating-setpoint",
+ "@id": "urn:ex/vav-513-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -4012,71 +3831,104 @@
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-in-connection",
+ "@id": "urn:ex/vav-537-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-537-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-537-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-508-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-517-air-in"
+ "@id": "urn:ex/vav-508-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-517-discharge-air-flow"
+ "@id": "urn:ex/vav-508-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-536-air-out",
+ "@id": "urn:ex/zone-312-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/connection-to-room-313"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-536-discharge-air-flow"
- },
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-111-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-536-discharge-air-flow-setpoint"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-536-discharge-air-temp"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-526-hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-526-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-air-out",
+ "@id": "urn:ex/vav-506-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -4084,412 +3936,360 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-heating-pid-output"
- },
+ "@id": "urn:ex/vav-506-air-in"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-valve-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-more-heat-requests"
+ "@id": "urn:ex/vav-527-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-air-out"
+ "@id": "urn:ex/vav-527-hot-water-out"
}
]
},
{
- "@id": "urn:ex/room-306",
+ "@id": "urn:ex/vav-511-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-306-hvac-domain"
+ "@id": "urn:ex/vav-511-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-511-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-116-117-occupancy",
+ "@id": "urn:ex/vav-540-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu",
+ "@id": "urn:ex/vav-530-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#AirHandlingUnit"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-chilled-water-in"
- },
- {
- "@id": "urn:ex/office-ahu-chilled-water-out"
- },
- {
- "@id": "urn:ex/office-ahu-ea-out"
- },
- {
- "@id": "urn:ex/office-ahu-hot-water-in"
- },
- {
- "@id": "urn:ex/office-ahu-hot-water-out"
- },
- {
- "@id": "urn:ex/office-ahu-oa-in"
- },
- {
- "@id": "urn:ex/office-ahu-ra-in"
- },
- {
- "@id": "urn:ex/office-ahu-sa-out"
+ "@id": "urn:ex/vav-530-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/office-ahu-air-filter"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-valve"
- },
- {
- "@id": "urn:ex/office-ahu-ea-damper"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-valve"
- },
- {
- "@id": "urn:ex/office-ahu-moisture-eliminator"
- },
- {
- "@id": "urn:ex/office-ahu-oa-damper"
- },
- {
- "@id": "urn:ex/office-ahu-ra-damper"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-ra-fan"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/office-ahu-sa-fan"
+ "@id": "urn:ex/vav-530-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-503-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-503-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-503-hot-water-in"
}
]
},
{
- "@id": "urn:ex/room-313",
+ "@id": "urn:ex/vav-538-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-104-occupancy-sensor",
+ "@id": "urn:ex/vav-521-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-104-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-104-occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-314-out",
+ "@id": "urn:ex/vav-522-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-522-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-522-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-522-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-526-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-526-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-526-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-309-310-temp-sensor",
+ "@id": "urn:ex/vav-528-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-309-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-309-310-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-301-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-524-heating-pid-output",
+ "@id": "urn:ex/vav-536-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil",
+ "@id": "urn:ex/room-205",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-517-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-water-out"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/room-205-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil",
+ "@id": "urn:ex/vav-510-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-526-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-526-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-526-reheat-coil-water-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-reheat-coil-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-106",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/room-106-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-532",
+ "@id": "urn:ex/vav-511-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-532-air-in"
- },
- {
- "@id": "urn:ex/vav-532-air-out"
- },
- {
- "@id": "urn:ex/vav-532-hot-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-532-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-532-damper"
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve",
+ "@id": "urn:ex/zone-104-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-534-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-512-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-512-air-in"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-534-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-512-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve",
+ "@id": "urn:ex/zone-204-205-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-515-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-516-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-515-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-actuator",
+ "@id": "urn:ex/vav-530-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-damper"
+ "@id": "urn:ex/vav-530-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-506-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-301-temp-sensor",
+ "@id": "urn:ex/vav-531-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-301-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-301-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-534-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-534-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -4499,7 +4299,7 @@
]
},
{
- "@id": "urn:ex/connection-to-room-108",
+ "@id": "urn:ex/vav-529-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -4511,309 +4311,244 @@
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve",
+ "@id": "urn:ex/vav-523-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-523-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-512-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-539-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-523-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-528",
+ "@id": "urn:ex/room-109",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-air-in"
- },
- {
- "@id": "urn:ex/vav-528-air-out"
- },
- {
- "@id": "urn:ex/vav-528-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-528-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-528-damper"
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve"
+ "@id": "urn:ex/room-109-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-506",
+ "@id": "urn:ex/vav-531",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-air-in"
+ "@id": "urn:ex/vav-531-air-in"
},
{
- "@id": "urn:ex/vav-506-air-out"
+ "@id": "urn:ex/vav-531-air-out"
},
{
- "@id": "urn:ex/vav-506-hot-water-in"
+ "@id": "urn:ex/vav-531-hot-water-in"
},
{
- "@id": "urn:ex/vav-506-hot-water-out"
+ "@id": "urn:ex/vav-531-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-506-damper"
+ "@id": "urn:ex/vav-531-damper"
},
{
- "@id": "urn:ex/vav-506-reheat-coil"
+ "@id": "urn:ex/vav-531-reheat-coil"
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve"
+ "@id": "urn:ex/vav-531-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-204-205",
+ "@id": "urn:ex/vav-517-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-204-hvac-domain"
- },
- {
- "@id": "urn:ex/room-205-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-517-damper"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-204-205-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-204-205-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-204-205-occupancy"
- },
- {
- "@id": "urn:ex/zone-204-205-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-204-205-temp"
- },
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/zone-204-205-window-switch-on-off"
+ "@id": "urn:ex/vav-517-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-temp",
+ "@id": "urn:ex/vav-518-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-118-in",
+ "@id": "urn:ex/vav-514-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-118"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-514-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/zone-102-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-514-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-511-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-511-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-511-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-511-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-528-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-528-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-528-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-531-damper",
+ "@id": "urn:ex/vav-520-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-damper-in"
- },
+ "@id": "urn:ex/vav-520-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-531-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-damper-command"
+ "@id": "urn:ex/vav-520-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-531-damper-position"
+ "@id": "urn:ex/vav-520-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-air-out",
+ "@id": "urn:ex/vav-504-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-106-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-210"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-524-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-more-heat-requests"
+ "@id": "urn:ex/vav-525-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-521-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-521-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -4823,96 +4558,73 @@
]
},
{
- "@id": "urn:ex/vav-529",
+ "@id": "urn:ex/office-ahu-ra-fan",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Fan",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-air-in"
- },
- {
- "@id": "urn:ex/vav-529-air-out"
- },
- {
- "@id": "urn:ex/vav-529-hot-water-in"
+ "@id": "urn:ex/office-ahu-ra-fan-in"
},
{
- "@id": "urn:ex/vav-529-hot-water-out"
+ "@id": "urn:ex/office-ahu-ra-fan-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-529-damper"
+ "@id": "urn:ex/office-ahu-ra-fan-power"
},
{
- "@id": "urn:ex/vav-529-reheat-coil"
+ "@id": "urn:ex/office-ahu-ra-fan-speed-cmd"
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-539-reheat-coil-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-539-reheat-coil-valve-in"
+ "@id": "urn:ex/office-ahu-ra-fan-speed-status"
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/office-ahu-ra-fan-start-cmd"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/office-ahu-ra-fan-start-status"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-539-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
}
]
},
{
- "@id": "urn:ex/zone-212-occupancy-override",
+ "@id": "urn:ex/zone-301-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-command",
+ "@id": "urn:ex/room-304-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-519-damper-position",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -4926,30 +4638,21 @@
]
},
{
- "@id": "urn:ex/zone-118-heating-setpoint",
+ "@id": "urn:ex/vav-521-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-air-in",
+ "@id": "urn:ex/connection-to-room-309-310",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-538-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -4958,179 +4661,199 @@
]
},
{
- "@id": "urn:ex/connection-to-room-201",
+ "@id": "urn:ex/vav-518-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-515-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-533-damper",
+ "@id": "urn:ex/vav-537-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-533-damper-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-533-damper-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-533-damper-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-533-damper-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-508-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-508-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-508-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-505-cooling-pid-output",
+ "@id": "urn:ex/zone-309-310-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-air-out",
+ "@id": "urn:ex/room-312-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-116-117"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-515-heating-pid-output"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-515-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-515-air-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-534-air-in",
+ "@id": "urn:ex/vav-502-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil",
+ "@id": "urn:ex/room-202-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-reheat-coil-air-in"
+ "@id": "urn:ex/room-202-in"
},
{
- "@id": "urn:ex/vav-525-reheat-coil-air-out"
- },
+ "@id": "urn:ex/room-202-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-525-reheat-coil-water-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-213-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-out",
+ "@id": "urn:ex/vav-502-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-duct-after-air-filter",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-speed-cmd",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -5144,121 +4867,122 @@
]
},
{
- "@id": "urn:ex/room-210",
+ "@id": "urn:ex/vav-515-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-210-hvac-domain"
+ "@id": "urn:ex/vav-515-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-out",
+ "@id": "urn:ex/room-114",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-538-hot-water-out-connection"
+ "@id": "urn:ex/room-114-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-538-hot-water-out"
- }
]
},
{
- "@id": "urn:ex/zone-215-cooling-setpoint",
+ "@id": "urn:ex/vav-533-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-508-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-309-310-occupancy",
+ "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-duct-after-damper",
+ "@id": "urn:ex/vav-509-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
- ]
- },
- {
- "@id": "urn:ex/zone-109-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-520-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-506-air-out"
+ "@id": "urn:ex/vav-520-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-506-discharge-air-temp"
+ "@id": "urn:ex/vav-520-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-110-heating-setpoint",
+ "@id": "urn:ex/vav-529-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -5274,96 +4998,90 @@
]
},
{
- "@id": "urn:ex/vav-531-hot-water-out-connection",
+ "@id": "urn:ex/room-115-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-cooling-pid-output",
+ "@id": "urn:ex/vav-529-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-529-air-in"
}
- ]
- },
- {
- "@id": "urn:ex/vav-517-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-529-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/connection-to-room-301",
+ "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-109-window-switch-on-off",
+ "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-damper-in",
+ "@id": "urn:ex/vav-509-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-air-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-water-out",
+ "@id": "urn:ex/vav-539-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5373,23 +5091,23 @@
]
},
{
- "@id": "urn:ex/zone-206-cooling-setpoint",
+ "@id": "urn:ex/zone-313-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-313-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-313-temp"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -5405,114 +5123,72 @@
]
},
{
- "@id": "urn:ex/office-ahu-ra-temp",
+ "@id": "urn:ex/vav-511-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Return"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-519-air-out",
+ "@id": "urn:ex/vav-537-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-204-205"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-519-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-519-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-519-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-519-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-cooling-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-107",
+ "@id": "urn:ex/connection-to-room-110",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-107-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-air-out",
+ "@id": "urn:ex/vav-534-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-115"
+ "@id": "urn:ex/vav-534-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-514-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-514-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-514-air-out"
+ "@id": "urn:ex/vav-534-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-flow",
+ "@id": "urn:ex/vav-518-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -5523,106 +5199,96 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-506-hot-water-out",
+ "@id": "urn:ex/zone-208-209-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-506-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-215-occupancy-sensor",
+ "@id": "urn:ex/room-208",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-215-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/zone-215-occupancy"
+ "@id": "urn:ex/room-208-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-507",
+ "@id": "urn:ex/vav-516",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-air-in"
+ "@id": "urn:ex/vav-516-air-in"
},
{
- "@id": "urn:ex/vav-507-air-out"
+ "@id": "urn:ex/vav-516-air-out"
},
{
- "@id": "urn:ex/vav-507-hot-water-in"
+ "@id": "urn:ex/vav-516-hot-water-in"
},
{
- "@id": "urn:ex/vav-507-hot-water-out"
+ "@id": "urn:ex/vav-516-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-507-damper"
+ "@id": "urn:ex/vav-516-damper"
},
{
- "@id": "urn:ex/vav-507-reheat-coil"
+ "@id": "urn:ex/vav-516-reheat-coil"
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve"
+ "@id": "urn:ex/vav-516-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-position",
+ "@id": "urn:ex/room-108-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-301-hvac-domain",
+ "@id": "urn:ex/room-206-hvac-domain",
"@type": [
"http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-301-in"
+ "@id": "urn:ex/room-206-in"
},
{
- "@id": "urn:ex/room-301-out"
+ "@id": "urn:ex/room-206-out"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -5632,76 +5298,99 @@
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-511-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-511-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint",
+ "@id": "urn:ex/vav-529-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-water-in",
+ "@id": "urn:ex/vav-515-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-532-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-520-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-532-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-207-temp-sensor",
+ "@id": "urn:ex/vav-536-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-207-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-207-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-538-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -5713,161 +5402,138 @@
]
},
{
- "@id": "urn:ex/vav-531-hot-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-531-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-501-damper",
+ "@id": "urn:ex/room-306",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-501-damper-in"
- },
- {
- "@id": "urn:ex/vav-501-damper-out"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-501-damper-command"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-501-damper-position"
+ "@id": "urn:ex/room-306-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-519-damper-out",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-duct-after-damper"
+ "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-519-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-519-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-damper-actuator",
+ "@id": "urn:ex/vav-523-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-535-damper"
+ "@id": "urn:ex/vav-523-air-in"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-535-damper-command"
+ "@id": "urn:ex/vav-523-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-536-cooling-pid-output",
+ "@id": "urn:ex/vav-503-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-507-cooling-pid-output",
+ "@id": "urn:ex/vav-525-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-525-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-525-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-525-damper-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-temp-setpoint",
+ "@id": "urn:ex/vav-501-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-501-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-water-in",
+ "@id": "urn:ex/zone-112-114-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-508-hot-water-in-connection"
+ "@id": "urn:ex/room-112-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-112-114-occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-102",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-508-hot-water-in"
+ "@id": "urn:ex/room-102-hvac-domain"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-air-out",
+ "@id": "urn:ex/room-113-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-clg-coil"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -5877,7 +5543,7 @@
]
},
{
- "@id": "urn:ex/vav-523-hot-water-in-connection",
+ "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -5889,230 +5555,212 @@
]
},
{
- "@id": "urn:ex/vav-519-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-116-117-occupancy-sensor",
+ "@id": "urn:ex/zone-203-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-116-hvac-domain"
+ "@id": "urn:ex/room-203-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-116-117-occupancy"
+ "@id": "urn:ex/zone-203-temp"
}
]
},
{
- "@id": "urn:ex/room-101",
+ "@id": "urn:ex/vav-509-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-actuator",
+ "@id": "urn:ex/room-309-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-damper"
+ "@id": "urn:ex/room-309-in"
+ },
+ {
+ "@id": "urn:ex/room-309-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-532-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-518-damper-actuator",
+ "@id": "urn:ex/vav-539-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-112-114-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-539-air-in"
}
]
},
{
- "@id": "urn:ex/zone-112-114-occupancy",
+ "@id": "urn:ex/zone-113-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-518-hot-water-out",
+ "@id": "urn:ex/vav-518-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-518-hot-water-out-connection"
+ "@id": "urn:ex/vav-518-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-518-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-503-damper-out",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-duct-after-damper"
+ "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-503-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-503-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-105-out",
+ "@id": "urn:ex/vav-512-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-512-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/zone-116-117-heating-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-512-reheat-coil-valve-command"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-512-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-water-in",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-522-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-525-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-522-hot-water-in"
+ "@id": "urn:ex/vav-525-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-118-occupancy-sensor",
+ "@id": "urn:ex/vav-520-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-118-occupancy"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-106-out",
+ "@id": "urn:ex/room-212-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-212-in"
+ },
+ {
+ "@id": "urn:ex/room-212-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-in",
+ "@id": "urn:ex/vav-501-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-501-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6120,21 +5768,20 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-527-air-in"
+ "@id": "urn:ex/vav-501-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-501-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/room-212-in",
+ "@id": "urn:ex/connection-to-room-108",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-212"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6143,34 +5790,29 @@
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-out",
+ "@id": "urn:ex/room-109-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-509-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-501-air-in",
+ "@id": "urn:ex/vav-509-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-509-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6180,13 +5822,13 @@
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-523-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6196,150 +5838,165 @@
]
},
{
- "@id": "urn:ex/office-ahu-warmer-supply-air-requests",
+ "@id": "urn:ex/zone-215-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-523-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-514-cooling-pid-output",
+ "@id": "urn:ex/vav-531-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-105",
+ "@id": "urn:ex/vav-504",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-105-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-105-cooling-setpoint"
+ "@id": "urn:ex/vav-504-air-in"
},
{
- "@id": "urn:ex/zone-105-heating-setpoint"
+ "@id": "urn:ex/vav-504-air-out"
},
{
- "@id": "urn:ex/zone-105-occupancy"
+ "@id": "urn:ex/vav-504-hot-water-in"
},
{
- "@id": "urn:ex/zone-105-occupancy-override"
+ "@id": "urn:ex/vav-504-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-504-damper"
},
{
- "@id": "urn:ex/zone-105-temp"
+ "@id": "urn:ex/vav-504-reheat-coil"
},
{
- "@id": "urn:ex/zone-105-window-switch-on-off"
+ "@id": "urn:ex/vav-504-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-water-out",
+ "@id": "urn:ex/zone-118-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-510-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan",
+ "@id": "urn:ex/zone-109-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Fan",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-ra-fan-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-ra-fan-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-515-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-ra-fan-power"
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan-speed-cmd"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-ra-fan-speed-status"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-536-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-ra-fan-start-cmd"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ra-fan-start-status"
+ "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Return"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve",
+ "@id": "urn:ex/vav-537-reheat-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-537-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-537-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -6349,159 +6006,177 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-537-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-537-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-302-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-302-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-302-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-water-in",
+ "@id": "urn:ex/zone-101-co2-concentration",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-528-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/zone-109-occupancy",
+ "@id": "urn:ex/room-303-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/room-303-in"
+ },
+ {
+ "@id": "urn:ex/room-303-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-538-heating-pid-output",
+ "@id": "urn:ex/zone-116-117-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-505",
+ "@id": "urn:ex/vav-539-air-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-air-in"
- },
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-air-out"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-301",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-505-hot-water-in"
- },
+ "@id": "urn:ex/room-301-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-505-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-505-damper"
+ "@id": "urn:ex/zone-301-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-505-reheat-coil"
+ "@id": "urn:ex/zone-301-heating-setpoint"
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve"
+ "@id": "urn:ex/zone-301-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-301-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-301-temp"
+ },
+ {
+ "@id": "urn:ex/zone-301-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-109-heating-setpoint",
+ "@id": "urn:ex/vav-510-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-537",
+ "@id": "urn:ex/vav-513-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-537-air-in"
- },
- {
- "@id": "urn:ex/vav-537-air-out"
- },
- {
- "@id": "urn:ex/vav-537-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-537-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-537-damper"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-537-reheat-coil"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-534-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -6517,153 +6192,182 @@
]
},
{
- "@id": "urn:ex/vav-536-damper-in",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-517-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-536-air-in"
+ "@id": "urn:ex/vav-517-hot-water-out"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-in",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-306-hvac-domain",
+ "@id": "urn:ex/vav-517-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-306-in"
- },
- {
- "@id": "urn:ex/room-306-out"
+ "@id": "urn:ex/vav-517-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-504-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/zone-118-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-305",
+ "@id": "urn:ex/zone-311-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-305-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-527-hot-water-in-connection",
+ "@id": "urn:ex/room-105-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-water-in",
+ "@id": "urn:ex/vav-511-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-hot-water-in-connection"
+ "@id": "urn:ex/vav-511-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-505-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-512-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-521-hot-water-in-connection",
+ "@id": "urn:ex/vav-540-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-215"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-540-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-540-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-540-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-540-discharge-air-temp-setpoint"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-540-hot-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-540-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6672,98 +6376,81 @@
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-temp",
+ "@id": "urn:ex/vav-512-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-water-out",
+ "@id": "urn:ex/vav-513-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-504-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-513-air-in"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil",
+ "@id": "urn:ex/vav-534-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-clg-coil-air-in"
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-air-out"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-clg-coil-water-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-clg-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-538-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-538-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-538-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-in-connection",
+ "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -6775,19 +6462,28 @@
]
},
{
- "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-538-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-538-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/zone-302-heating-setpoint",
+ "@id": "urn:ex/vav-515-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -6803,127 +6499,100 @@
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-air-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-212"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-526-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-526-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-526-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-514-reheat-coil-air-in",
+ "@id": "urn:ex/vav-512-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-526-air-out",
+ "@id": "urn:ex/vav-535-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-212"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-535-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-535-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-526-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-526-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-526-discharge-air-temp"
+ "@id": "urn:ex/vav-535-damper-command"
},
{
- "@id": "urn:ex/vav-526-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-535-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-527-colder-supply-air-requests",
+ "@id": "urn:ex/office-ahu-ma-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-air-filter-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/office-ahu-ma-temp"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-command",
+ "@id": "urn:ex/vav-533-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-207-window-switch-on-off",
+ "@id": "urn:ex/room-308-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-308-in"
+ },
+ {
+ "@id": "urn:ex/room-308-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/room-115-in",
+ "@id": "urn:ex/vav-507-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-115"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6932,131 +6601,101 @@
]
},
{
- "@id": "urn:ex/vav-519-damper",
+ "@id": "urn:ex/vav-508-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-damper-in"
- },
+ "@id": "urn:ex/vav-508-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-519-damper-command"
+ "@id": "urn:ex/vav-508-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-519-damper-position"
+ "@id": "urn:ex/vav-508-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-535",
+ "@id": "urn:ex/vav-535-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-air-in"
+ "@id": "urn:ex/vav-535-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-535-air-out"
+ "@id": "urn:ex/vav-535-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-535-hot-water-in"
+ "@id": "urn:ex/vav-535-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-535-hot-water-out"
+ "@id": "urn:ex/vav-535-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-535-damper"
- },
- {
- "@id": "urn:ex/vav-535-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/room-212-hvac-domain",
+ "@id": "urn:ex/vav-515-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-212-in"
- },
- {
- "@id": "urn:ex/room-212-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-515-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/zone-314-cooling-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-515-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-in",
+ "@id": "urn:ex/office-ahu-clg-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-duct-after-clg-coil"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-heating-pid-output",
+ "@id": "urn:ex/vav-524-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/zone-108-heating-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -7070,35 +6709,53 @@
]
},
{
- "@id": "urn:ex/vav-525-duct-after-damper",
+ "@id": "urn:ex/vav-537-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-312"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-537-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-515-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-108-out",
+ "@id": "urn:ex/room-213-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -7114,23 +6771,30 @@
]
},
{
- "@id": "urn:ex/vav-524-damper-position",
+ "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-207",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/room-207-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-115-occupancy-override",
+ "@id": "urn:ex/zone-211-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -7141,165 +6805,239 @@
]
},
{
- "@id": "urn:ex/vav-511-hot-water-out",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-hot-water-out-connection"
+ "@id": "urn:ex/vav-531-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-531-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-512-damper-position",
+ "@id": "urn:ex/zone-106-107-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-118-temp-sensor",
+ "@id": "urn:ex/vav-527-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "urn:ex/vav-527-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-118-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-527-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-509-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-509-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-position",
+ "@id": "urn:ex/vav-517-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-202-temp",
+ "@id": "urn:ex/room-214-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-214-in"
+ },
+ {
+ "@id": "urn:ex/room-214-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-521-duct-after-damper",
+ "@id": "urn:ex/vav-527-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-301"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-527-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-527-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-527-air-out"
+ }
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-524-more-heat-requests",
+ "@id": "urn:ex/vav-507-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-507-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-507-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-109-in",
+ "@id": "urn:ex/zone-108-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-109"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-305",
+ "@id": "urn:ex/zone-302",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-305-hvac-domain"
+ "@id": "urn:ex/room-302-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -7309,98 +7047,87 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-305-cooling-setpoint"
+ "@id": "urn:ex/zone-302-co2-concentration"
},
{
- "@id": "urn:ex/zone-305-heating-setpoint"
+ "@id": "urn:ex/zone-302-co2-concentration-setpoint"
},
{
- "@id": "urn:ex/zone-305-occupancy"
+ "@id": "urn:ex/zone-302-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-305-occupancy-override"
+ "@id": "urn:ex/zone-302-heating-setpoint"
},
{
- "@id": "urn:ex/zone-305-temp"
+ "@id": "urn:ex/zone-302-occupancy"
},
{
- "@id": "urn:ex/zone-305-window-switch-on-off"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-214-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/zone-302-occupancy-override"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/zone-302-temp"
+ },
+ {
+ "@id": "urn:ex/zone-302-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-509-air-in",
+ "@id": "urn:ex/vav-518-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-518-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-201-window-switch-on-off",
+ "@id": "urn:ex/vav-531-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/vav-503-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-540-hot-water-out",
+ "@id": "urn:ex/zone-206-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-540-hot-water-out-connection"
+ "@id": "urn:ex/room-206-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-206-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-520-air-out",
+ "@id": "urn:ex/vav-504-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-207"
+ "@id": "urn:ex/vav-504-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -7410,49 +7137,15 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-520-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-520-discharge-air-temp"
+ "@id": "urn:ex/vav-504-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp-setpoint"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-523-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil-valve-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-504-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-208-209-temp",
+ "@id": "urn:ex/zone-106-107-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -7468,53 +7161,29 @@
]
},
{
- "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil-valve",
+ "@id": "urn:ex/vav-536-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-503-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-536-air-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-503-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-536-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-air-out",
+ "@id": "urn:ex/vav-518-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-207"
+ "@id": "urn:ex/connection-to-room-202"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -7524,26 +7193,27 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-heating-pid-output"
+ "@id": "urn:ex/vav-518-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-520-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/vav-518-discharge-air-flow-setpoint"
+ },
{
- "@id": "urn:ex/vav-520-air-out"
+ "@id": "urn:ex/vav-518-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-518-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-502-hot-water-out",
+ "@id": "urn:ex/vav-504-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-hot-water-out-connection"
+ "@id": "urn:ex/vav-504-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -7553,288 +7223,259 @@
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil",
+ "@id": "urn:ex/vav-505-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil-water-out"
+ "@id": "urn:ex/vav-505-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-507-hot-water-out",
+ "@id": "urn:ex/vav-536-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-hot-water-out-connection"
+ "@id": "urn:ex/vav-536-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-536-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-536-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-in",
+ "@id": "urn:ex/vav-508-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-529-air-in"
- }
]
},
{
- "@id": "urn:ex/zone-214-temp",
+ "@id": "urn:ex/vav-535-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-535-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-535-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-535-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-535-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-105-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-511-air-in"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-511-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-509-more-heat-requests",
+ "@id": "urn:ex/room-209",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-209-hvac-domain"
}
]
},
{
- "@id": "urn:ex/room-308-in",
+ "@id": "urn:ex/vav-530-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-307-308"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-530-air-in"
+ }
]
},
{
- "@id": "urn:ex/vav-508-air-out",
+ "@id": "urn:ex/zone-204-205",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-109"
+ "@id": "urn:ex/room-204-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-205-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-508-discharge-air-flow"
+ "@id": "urn:ex/zone-204-205-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-508-discharge-air-flow-setpoint"
+ "@id": "urn:ex/zone-204-205-heating-setpoint"
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp"
+ "@id": "urn:ex/zone-204-205-occupancy"
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp-setpoint"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-509-damper-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/zone-204-205-occupancy-override"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/zone-204-205-temp"
+ },
{
- "@id": "urn:ex/vav-509-air-in"
+ "@id": "urn:ex/zone-204-205-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-air-in",
+ "@id": "urn:ex/vav-519-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-117-in",
+ "@id": "urn:ex/vav-517-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-116-117"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/zone-305-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-113-occupancy-override",
+ "@id": "urn:ex/room-313",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/room-313-hvac-domain"
}
]
},
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure-sensor",
+ "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/office-ahu-sa-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-524-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-508-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-105-heating-setpoint",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-108-in",
+ "@id": "urn:ex/vav-524-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-108"
+ "@id": "urn:ex/vav-524-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -7844,28 +7485,20 @@
]
},
{
- "@id": "urn:ex/room-309-hvac-domain",
+ "@id": "urn:ex/zone-207-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-309-in"
- },
- {
- "@id": "urn:ex/room-309-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/zone-108-temp",
+ "@id": "urn:ex/zone-201-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -7879,53 +7512,82 @@
]
},
{
- "@id": "urn:ex/room-311-out",
+ "@id": "urn:ex/vav-524-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-514-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-115"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-514-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-514-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-514-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-514-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-525-damper-out",
+ "@id": "urn:ex/vav-523-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-528-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-525-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-306-in",
+ "@id": "urn:ex/room-307-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -7935,79 +7597,92 @@
]
},
{
- "@id": "urn:ex/zone-207-heating-setpoint",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-air-in",
+ "@id": "urn:ex/zone-314-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/room-314-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-314-occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-duct-after-damper"
+ "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-113-temp-sensor",
+ "@id": "urn:ex/vav-517-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-113-hvac-domain"
+ "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-113-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-out",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-duct-after-damper"
+ "@id": "urn:ex/office-ahu-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-540-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-540-cooling-pid-output"
+ "@id": "urn:ex/office-ahu-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-113-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -8023,30 +7698,31 @@
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-511-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-511-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-511-hot-water-in"
}
]
},
{
- "@id": "urn:ex/room-215-out",
+ "@id": "urn:ex/connection-to-room-305",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -8055,288 +7731,280 @@
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-flow",
+ "@id": "urn:ex/zone-204-205-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-212-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-302-co2-concentration-setpoint",
+ "@id": "urn:ex/vav-501-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#ofSubstance": [
- {
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/office-ahu-ma-temp",
+ "@id": "urn:ex/vav-519-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-519-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-519-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-531-colder-supply-air-requests",
+ "@id": "urn:ex/vav-530-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-water-out",
+ "@id": "urn:ex/vav-503-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-503-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-503-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-503-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-503-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-out",
+ "@id": "urn:ex/room-111-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-111"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-506-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-525-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-524-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-524-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil",
+ "@id": "urn:ex/vav-507-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil-water-out"
+ "@id": "urn:ex/vav-507-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-312-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-507-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-507-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-522-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-208-209"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-522-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-522-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-520-hot-water-out"
+ "@id": "urn:ex/vav-522-air-out"
}
]
},
{
- "@id": "urn:ex/zone-113-temp",
+ "@id": "urn:ex/vav-504-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/connection-to-room-105"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-517-heating-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-504-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-504-more-heat-requests"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-504-air-out"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-509-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-501-hot-water-out"
+ "@id": "urn:ex/vav-509-air-in"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-flow-setpoint",
+ "@id": "urn:ex/room-302-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-flow-setpoint",
+ "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil",
+ "@id": "urn:ex/vav-520-reheat-coil",
"@type": [
"http://data.ashrae.org/standard223#HeatingCoil",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-reheat-coil-air-in"
+ "@id": "urn:ex/vav-520-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-air-out"
+ "@id": "urn:ex/vav-520-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-in"
+ "@id": "urn:ex/vav-520-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-out"
+ "@id": "urn:ex/vav-520-reheat-coil-water-out"
}
],
"http://data.ashrae.org/standard223#hasRole": [
@@ -8346,87 +8014,108 @@
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-521-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-air-out"
+ "@id": "urn:ex/vav-521-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-532-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-214-occupancy-sensor",
+ "@id": "urn:ex/vav-516-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-214-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-214-occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-514-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-514-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-106-107-temp-sensor",
+ "@id": "urn:ex/vav-534",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-106-hvac-domain"
+ "@id": "urn:ex/vav-534-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-534-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-534-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-534-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/zone-106-107-temp"
+ "@id": "urn:ex/vav-534-damper"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-in",
+ "@id": "urn:ex/vav-507-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-515-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp",
+ "@id": "urn:ex/vav-540-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -8466,125 +8155,118 @@
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-539-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-527-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-539-hot-water-out"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-523-more-heat-requests",
+ "@id": "urn:ex/vav-503-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-208-209-cooling-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-503-reheat-coil-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-503-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-529-damper",
+ "@id": "urn:ex/vav-529-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-damper-in"
- },
+ "@id": "urn:ex/connection-to-room-303-304-306"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-529-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-529-damper-command"
+ "@id": "urn:ex/vav-529-heating-pid-output"
},
{
- "@id": "urn:ex/vav-529-damper-position"
+ "@id": "urn:ex/vav-529-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-529-air-out"
}
]
},
{
- "@id": "urn:ex/vav-516-hot-water-out-connection",
+ "@id": "urn:ex/vav-510-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-510-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-303-304-306-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-510-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-510-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-out",
+ "@id": "urn:ex/vav-504-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-duct-after-damper"
+ "@id": "urn:ex/vav-504-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-516-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-516-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-in",
+ "@id": "urn:ex/vav-510-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -8600,141 +8282,132 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-523-air-in"
+ "@id": "urn:ex/vav-510-air-in"
}
]
},
{
- "@id": "urn:ex/vav-533-damper-actuator",
+ "@id": "urn:ex/zone-206-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-533-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-533-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-539-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-in",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-516-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-504-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-516-hot-water-in"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-116-117-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-116-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-116-117-temp"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-537-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-531-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-212-occupancy-sensor",
+ "@id": "urn:ex/vav-533-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-212-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-212-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve",
+ "@id": "urn:ex/vav-527-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-523-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-527-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-527-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-527-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-flow",
+ "@id": "urn:ex/vav-515-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -8755,224 +8428,162 @@
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-525-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-502-air-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-502-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/room-304-out",
+ "@id": "urn:ex/vav-515-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-201-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-201-in"
- },
- {
- "@id": "urn:ex/room-201-out"
- }
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-515-air-in"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-air-in",
+ "@id": "urn:ex/vav-505-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-509-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-212",
+ "@id": "urn:ex/vav-520-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-212-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-212-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-212-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-212-occupancy"
- },
- {
- "@id": "urn:ex/zone-212-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-212-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-212-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-out",
+ "@id": "urn:ex/room-108-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-108"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-513-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve",
+ "@id": "urn:ex/vav-504-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-511-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-511-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-511-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-hot-water-in",
+ "@id": "urn:ex/vav-535-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-hot-water-in-connection"
+ "@id": "urn:ex/vav-535-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-in",
+ "@id": "urn:ex/zone-115-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-in",
+ "@id": "urn:ex/room-214-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-214"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-513-air-in"
- }
]
},
{
- "@id": "urn:ex/zone-102-temp-sensor",
+ "@id": "urn:ex/zone-211-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-102-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-102-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
@@ -8989,117 +8600,113 @@
]
},
{
- "@id": "urn:ex/zone-302-co2-sensor",
+ "@id": "urn:ex/zone-314-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "urn:ex/room-314-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-302-co2-concentration"
+ "@id": "urn:ex/zone-314-temp"
}
]
},
{
- "@id": "urn:ex/vav-539-cooling-pid-output",
+ "@id": "urn:ex/vav-538-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
}
- ]
- },
- {
- "@id": "urn:ex/vav-504-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-532-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-command",
+ "@id": "urn:ex/vav-538-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-108-hvac-domain",
+ "@id": "urn:ex/zone-214",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-108-in"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-108-out"
+ "@id": "urn:ex/room-214-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
{
"@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-508-discharge-air-flow-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-508-air-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/zone-214-cooling-setpoint"
+ },
{
- "@id": "urn:ex/vav-508-discharge-air-flow"
+ "@id": "urn:ex/zone-214-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-214-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-214-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-214-temp"
+ },
+ {
+ "@id": "urn:ex/zone-214-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-516-hot-water-in-connection",
+ "@id": "urn:ex/vav-529-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -9111,137 +8718,104 @@
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-water-out",
+ "@id": "urn:ex/vav-525-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-525-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-525-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-509-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-509-reheat-coil-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-509-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-518-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve",
+ "@id": "urn:ex/zone-101",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-512-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-out"
+ "@id": "urn:ex/room-101-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-command"
+ "@id": "urn:ex/zone-101-building-static-pressure"
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/room-205-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-520",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/zone-101-building-static-pressure-setpoint"
+ },
{
- "@id": "urn:ex/vav-520-air-in"
+ "@id": "urn:ex/zone-101-co2-concentration"
},
{
- "@id": "urn:ex/vav-520-air-out"
+ "@id": "urn:ex/zone-101-co2-concentration-setpoint"
},
{
- "@id": "urn:ex/vav-520-hot-water-in"
+ "@id": "urn:ex/zone-101-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-520-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
+ "@id": "urn:ex/zone-101-heating-setpoint"
+ },
{
- "@id": "urn:ex/vav-520-damper"
+ "@id": "urn:ex/zone-101-occupancy"
},
{
- "@id": "urn:ex/vav-520-reheat-coil"
+ "@id": "urn:ex/zone-101-occupancy-override"
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-215-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/zone-101-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/zone-101-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-525-air-out",
+ "@id": "urn:ex/vav-529-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-211"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -9249,436 +8823,424 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-525-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-525-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-525-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-525-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-529-air-in"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-in",
+ "@id": "urn:ex/vav-527-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-505-hot-water-in-connection"
+ "@id": "urn:ex/vav-527-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-527-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/connection-to-room-309-310",
+ "@id": "urn:ex/vav-534-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-104-hvac-domain",
+ "@id": "urn:ex/vav-526-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-104-in"
- },
- {
- "@id": "urn:ex/room-104-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-526-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-514-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-526-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-113-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-503",
+ "@id": "urn:ex/office-ahu-ra-fan-out",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-air-in"
- },
- {
- "@id": "urn:ex/vav-503-air-out"
- },
- {
- "@id": "urn:ex/vav-503-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-503-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-503-damper"
- },
- {
- "@id": "urn:ex/vav-503-reheat-coil"
- },
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/zone-212-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-522-colder-supply-air-requests",
+ "@id": "urn:ex/room-117",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-117-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-538-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-air-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-538-air-in"
}
]
},
{
- "@id": "urn:ex/vav-530-hot-water-in-connection",
+ "@id": "urn:ex/vav-508-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-526-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-212"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-526-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-526-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-522-hot-water-out"
+ "@id": "urn:ex/vav-526-air-out"
}
]
},
{
- "@id": "urn:ex/room-204",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-204-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-flow",
+ "@id": "urn:ex/vav-513-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-513-damper"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-513-damper-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-214-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-temp",
+ "@id": "urn:ex/office-ahu-ra-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-command",
+ "@id": "urn:ex/vav-526-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-533-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-113-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-529-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-529-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-204-205-occupancy-sensor",
+ "@id": "urn:ex/zone-211-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-204-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-204-205-occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-actuator",
+ "@id": "urn:ex/room-108",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-526-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-command"
+ "@id": "urn:ex/room-108-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-air-in",
+ "@id": "urn:ex/vav-531-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-531-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-531-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-531-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-531-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/zone-208-209-temp-sensor",
+ "@id": "urn:ex/vav-535-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-208-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-208-209-temp"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-509-colder-supply-air-requests",
+ "@id": "urn:ex/zone-307-308-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/zone-313-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-ra-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-actuator",
+ "@id": "urn:ex/vav-501-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-540-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-102",
+ "@id": "urn:ex/vav-530-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-102-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-519-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-519-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -9688,104 +9250,80 @@
]
},
{
- "@id": "urn:ex/vav-511-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/connection-to-room-101",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-512-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-511-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-511-hot-water-out"
- }
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-101-co2-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-101-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-101-co2-concentration"
}
]
},
{
- "@id": "urn:ex/room-107-out",
+ "@id": "urn:ex/vav-512-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-512-air-in"
+ }
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-538-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-526-heating-pid-output",
+ "@id": "urn:ex/vav-503-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -9801,39 +9339,39 @@
]
},
{
- "@id": "urn:ex/vav-521-air-in",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-105-temp",
+ "@id": "urn:ex/zone-105-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-105-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-105-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-522-hot-water-in-connection",
+ "@id": "urn:ex/vav-511-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -9845,57 +9383,82 @@
]
},
{
- "@id": "urn:ex/vav-519-cooling-pid-output",
+ "@id": "urn:ex/zone-215",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-215-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-215-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-215-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-215-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-215-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-215-temp"
+ },
+ {
+ "@id": "urn:ex/zone-215-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-air-in",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-duct-after-damper"
+ "@id": "urn:ex/vav-523-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-523-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-506-hot-water-in-connection",
+ "@id": "urn:ex/vav-502-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-540-hot-water-in",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -9905,102 +9468,108 @@
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-flow",
+ "@id": "urn:ex/vav-518-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-207-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-511-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-511-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-temp",
+ "@id": "urn:ex/zone-102-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-102-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-102-temp"
}
]
},
{
- "@id": "urn:ex/zone-307-308-window-switch-on-off",
+ "@id": "urn:ex/vav-529-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil",
+ "@id": "urn:ex/vav-529-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-519-reheat-coil-water-out"
+ "@id": "urn:ex/vav-529-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-524-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -10016,45 +9585,34 @@
]
},
{
- "@id": "urn:ex/zone-215-heating-setpoint",
+ "@id": "urn:ex/vav-531-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-516-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-air-out",
+ "@id": "urn:ex/vav-532-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-109"
+ "@id": "urn:ex/connection-to-room-309-310"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10064,131 +9622,148 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-508-heating-pid-output"
+ "@id": "urn:ex/vav-532-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-508-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/vav-532-discharge-air-flow-setpoint"
+ },
{
- "@id": "urn:ex/vav-508-air-out"
+ "@id": "urn:ex/vav-532-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-532-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/room-202-out",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-535-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-535-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-505-heating-pid-output",
+ "@id": "urn:ex/zone-106-107-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-532-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-509-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-510-air-in"
+ "@id": "urn:ex/vav-509-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-510-discharge-air-flow"
+ "@id": "urn:ex/vav-509-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-526-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-515-damper-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-out",
+ "@id": "urn:ex/vav-524",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-hot-water-out-connection"
+ "@id": "urn:ex/vav-524-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-524-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-524-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-524-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-524-damper"
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-valve"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-206-temp",
+ "@id": "urn:ex/vav-501-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -10201,35 +9776,29 @@
]
},
{
- "@id": "urn:ex/vav-523-colder-supply-air-requests",
+ "@id": "urn:ex/room-207-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/zone-311-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-air-in",
+ "@id": "urn:ex/room-111-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10239,157 +9808,132 @@
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-211-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-519-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-537-colder-supply-air-requests",
+ "@id": "urn:ex/zone-208-209-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-536-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-536-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-115-out",
+ "@id": "urn:ex/office-ahu-htg-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-307-308",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-515-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-211-occupancy-sensor",
+ "@id": "urn:ex/vav-534-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-211-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-211-occupancy"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-hot-water-out-connection",
+ "@id": "urn:ex/zone-103-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/zone-102-cooling-setpoint",
+ "@id": "urn:ex/vav-534-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-519-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-519-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10398,140 +9942,139 @@
]
},
{
- "@id": "urn:ex/zone-301-occupancy-sensor",
+ "@id": "urn:ex/room-115-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-301-hvac-domain"
+ "@id": "urn:ex/connection-to-room-115"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-301-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-514-damper",
+ "@id": "urn:ex/vav-528-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-damper-in"
- },
- {
- "@id": "urn:ex/vav-514-damper-out"
+ "@id": "urn:ex/vav-528-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-514-damper-command"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-514-damper-position"
+ "@id": "urn:ex/vav-528-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-command",
+ "@id": "urn:ex/office-ahu-sa-fan-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-sa-out"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve",
+ "@id": "urn:ex/room-307-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-in"
+ "@id": "urn:ex/room-307-in"
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/room-307-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-520-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-112-114-heating-setpoint",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-538-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-538-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-501-hot-water-out",
+ "@id": "urn:ex/vav-527-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-501-hot-water-out-connection"
+ "@id": "urn:ex/vav-527-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-527-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-532-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-532-air-in"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-command",
+ "@id": "urn:ex/office-ahu-sa-fan-speed-status",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -10545,61 +10088,54 @@
]
},
{
- "@id": "urn:ex/room-305-in",
+ "@id": "urn:ex/vav-522-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-305"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-104-temp-sensor",
+ "@id": "urn:ex/vav-509-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-104-hvac-domain"
+ "@id": "urn:ex/connection-to-room-113"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-104-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "@id": "urn:ex/vav-509-discharge-air-flow"
+ },
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-509-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-509-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-509-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-air-in",
+ "@id": "urn:ex/vav-520-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-duct-after-damper"
+ "@id": "urn:ex/vav-520-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10609,7 +10145,7 @@
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-215-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -10625,247 +10161,206 @@
]
},
{
- "@id": "urn:ex/vav-530",
+ "@id": "urn:ex/vav-533-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-530-air-in"
- },
- {
- "@id": "urn:ex/vav-530-air-out"
- },
- {
- "@id": "urn:ex/vav-530-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-530-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-530-damper"
- },
- {
- "@id": "urn:ex/vav-530-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil",
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure-sensor",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-511-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-511-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-511-reheat-coil-water-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-511-reheat-coil-water-out"
+ "@id": "urn:ex/office-ahu-sa-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-water-in",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-hot-water-in-connection"
+ "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-506-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/zone-101-temp",
+ "@id": "urn:ex/room-303",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/room-303-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-518-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-air-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-521-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-209-in",
+ "@id": "urn:ex/room-312-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-208-209"
+ "@id": "urn:ex/room-312-in"
+ },
+ {
+ "@id": "urn:ex/room-312-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-514-hot-water-out",
+ "@id": "urn:ex/vav-522-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-514-hot-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-528-damper",
+ "@id": "urn:ex/connection-to-room-211",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-528-damper-in"
- },
- {
- "@id": "urn:ex/vav-528-damper-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-528-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-528-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-506-damper",
+ "@id": "urn:ex/vav-509-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-damper-in"
+ "@id": "urn:ex/vav-509-damper-in"
},
{
- "@id": "urn:ex/vav-506-damper-out"
+ "@id": "urn:ex/vav-509-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-506-damper-command"
+ "@id": "urn:ex/vav-509-damper-command"
},
{
- "@id": "urn:ex/vav-506-damper-position"
+ "@id": "urn:ex/vav-509-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-out",
+ "@id": "urn:ex/vav-523-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-537-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-537-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-537-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-213-out",
+ "@id": "urn:ex/zone-213",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-213-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/room-302",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "urn:ex/zone-213-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-213-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-213-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-213-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-213-temp"
+ },
+ {
+ "@id": "urn:ex/zone-213-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-111-heating-setpoint",
+ "@id": "urn:ex/zone-118-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -10881,258 +10376,267 @@
]
},
{
- "@id": "urn:ex/zone-204-205-window-switch-on-off",
+ "@id": "urn:ex/vav-507-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-507-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-507-damper-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-214-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-507-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-507-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-519-hot-water-in",
+ "@id": "urn:ex/vav-529-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-515-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-515-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-538",
+ "@id": "urn:ex/zone-102-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-538-air-in"
- },
- {
- "@id": "urn:ex/vav-538-air-out"
- },
- {
- "@id": "urn:ex/vav-538-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-538-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-538-damper"
- },
- {
- "@id": "urn:ex/vav-538-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-538-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-position",
+ "@id": "urn:ex/zone-110-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-110-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-110-temp"
}
]
},
{
- "@id": "urn:ex/zone-311-window-switch-on-off",
+ "@id": "urn:ex/vav-532-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-532-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-532-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-204-205-heating-setpoint",
+ "@id": "urn:ex/office-ahu-clg-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-chilled-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-510-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-colder-chilled-water-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-chilled-water-in"
}
]
},
{
- "@id": "urn:ex/vav-520-heating-pid-output",
+ "@id": "urn:ex/vav-540-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-540-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-538-air-out",
+ "@id": "urn:ex/zone-311",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-213"
+ "@id": "urn:ex/room-311-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-538-discharge-air-flow"
+ "@id": "urn:ex/zone-311-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-538-discharge-air-flow-setpoint"
+ "@id": "urn:ex/zone-311-heating-setpoint"
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp"
+ "@id": "urn:ex/zone-311-occupancy"
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp-setpoint"
+ "@id": "urn:ex/zone-311-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-311-temp"
+ },
+ {
+ "@id": "urn:ex/zone-311-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/zone-206-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-207",
+ "@id": "urn:ex/vav-509-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-207-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-207-cooling-setpoint"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-207-heating-setpoint"
+ "@id": "urn:ex/vav-529-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/zone-207-occupancy"
- },
+ "@id": "urn:ex/vav-529-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-207-occupancy-override"
- },
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-207-temp"
+ "@id": "urn:ex/vav-529-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/zone-207-window-switch-on-off"
+ "@id": "urn:ex/vav-529-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-211-heating-setpoint",
+ "@id": "urn:ex/vav-523-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-203-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -11148,19 +10652,18 @@
]
},
{
- "@id": "urn:ex/connection-to-room-109",
+ "@id": "urn:ex/vav-533-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-in-connection",
+ "@id": "urn:ex/vav-518-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -11172,159 +10675,128 @@
]
},
{
- "@id": "urn:ex/zone-116-117",
+ "@id": "urn:ex/zone-301-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-116-hvac-domain"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-117-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-116-117-cooling-setpoint"
+ "@id": "urn:ex/vav-507-air-in"
},
{
- "@id": "urn:ex/zone-116-117-heating-setpoint"
+ "@id": "urn:ex/vav-507-air-out"
},
{
- "@id": "urn:ex/zone-116-117-occupancy"
+ "@id": "urn:ex/vav-507-hot-water-in"
},
{
- "@id": "urn:ex/zone-116-117-occupancy-override"
+ "@id": "urn:ex/vav-507-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-507-damper"
},
{
- "@id": "urn:ex/zone-116-117-temp"
+ "@id": "urn:ex/vav-507-reheat-coil"
},
{
- "@id": "urn:ex/zone-116-117-window-switch-on-off"
+ "@id": "urn:ex/vav-507-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-506-cooling-pid-output",
+ "@id": "urn:ex/vav-506-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-533-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/connection-to-room-305"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-106-107",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-520-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-539-reheat-coil",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-539-reheat-coil-air-in"
+ "@id": "urn:ex/vav-533-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-539-reheat-coil-air-out"
+ "@id": "urn:ex/vav-533-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-539-reheat-coil-water-in"
+ "@id": "urn:ex/vav-533-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-539-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-533-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-518-damper-out",
+ "@id": "urn:ex/room-114-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-112-114"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-518-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-518-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-water-out",
+ "@id": "urn:ex/office-ahu-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11334,28 +10806,23 @@
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-water-in",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-507-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-507-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-110-window-switch-on-off",
+ "@id": "urn:ex/zone-112-114-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -11366,66 +10833,55 @@
]
},
{
- "@id": "urn:ex/vav-506-air-in",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-532-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-532-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-103",
+ "@id": "urn:ex/vav-510-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-103-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:ex/zone-104-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-206-heating-setpoint",
+ "@id": "urn:ex/zone-305-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -11441,13 +10897,13 @@
]
},
{
- "@id": "urn:ex/vav-510-damper-in",
+ "@id": "urn:ex/vav-520-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-207"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11455,241 +10911,229 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-510-air-in"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-520-discharge-air-flow"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-520-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-520-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-520-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-518-damper",
+ "@id": "urn:ex/vav-518-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-518-damper-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-518-damper-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-518-damper-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-518-damper-position"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-515-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-hot-water-out-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-515-reheat-coil-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-515-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-512-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/room-104",
+ "@id": "urn:ex/vav-507-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-104-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-313-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-507-air-out"
+ "@id": "urn:ex/room-313-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-507-discharge-air-temp"
+ "@id": "urn:ex/zone-313-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-528-cooling-pid-output",
+ "@id": "urn:ex/vav-531-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-531-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-531-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-water-out",
+ "@id": "urn:ex/vav-513-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-513-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-530-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-513-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-513-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-515-damper-in",
+ "@id": "urn:ex/vav-514-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-515-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-105-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-207-in",
+ "@id": "urn:ex/vav-530-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-207"
+ "@id": "urn:ex/vav-530-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-530-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-309-in",
+ "@id": "urn:ex/room-306-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/room-306-in"
+ },
+ {
+ "@id": "urn:ex/room-306-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil",
+ "@id": "urn:ex/room-110-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-515-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-515-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-515-reheat-coil-water-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-chilled-water-in",
+ "@id": "urn:ex/vav-534-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-chilled-water-in-connection"
+ "@id": "urn:ex/vav-534-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11699,45 +11143,66 @@
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-512-hot-water-out",
+ "@id": "urn:ex/zone-312",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-512-hot-water-out-connection"
+ "@id": "urn:ex/room-312-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-312-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-312-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-312-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-312-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-312-temp"
+ },
+ {
+ "@id": "urn:ex/zone-312-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-527-air-in",
+ "@id": "urn:ex/office-ahu-moisture-eliminator-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11747,122 +11212,116 @@
]
},
{
- "@id": "urn:ex/vav-509-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-540-air-in",
+ "@id": "urn:ex/vav-526-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-526-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-526-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-526-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/vav-535-damper-in",
+ "@id": "urn:ex/vav-525-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-525-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-535-air-in"
+ "@id": "urn:ex/vav-525-hot-water-in"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-start-cmd",
+ "@id": "urn:ex/vav-501-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
}
- ]
- },
- {
- "@id": "urn:ex/vav-507-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-523-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-523-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-214-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-ra-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-532-hot-water-in-connection",
+ "@id": "urn:ex/vav-525-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-525-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-525-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -11874,9 +11333,9 @@
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-502-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -11890,209 +11349,263 @@
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-flow",
+ "@id": "urn:ex/vav-528-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/connection-to-room-302"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-528-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-528-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-528-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-528-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/room-215-hvac-domain",
+ "@id": "urn:ex/vav-534-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-534-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-534-discharge-air-temp"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-215-in"
+ "@id": "urn:ex/connection-to-room-111"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-510-heating-pid-output"
},
{
- "@id": "urn:ex/room-215-out"
+ "@id": "urn:ex/vav-510-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-510-air-out"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-command",
+ "@id": "urn:ex/vav-519-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-519-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-519-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-519-air-out"
}
]
},
{
- "@id": "urn:ex/zone-118-cooling-setpoint",
+ "@id": "urn:ex/vav-502-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-502-air-in"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-510-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-air-out",
+ "@id": "urn:ex/vav-502-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-532-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-532-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-532-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil",
+ "@id": "urn:ex/vav-537",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-reheat-coil-air-in"
+ "@id": "urn:ex/vav-537-air-in"
},
{
- "@id": "urn:ex/vav-514-reheat-coil-air-out"
+ "@id": "urn:ex/vav-537-air-out"
},
{
- "@id": "urn:ex/vav-514-reheat-coil-water-in"
+ "@id": "urn:ex/vav-537-hot-water-in"
},
{
- "@id": "urn:ex/vav-514-reheat-coil-water-out"
+ "@id": "urn:ex/vav-537-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-537-damper"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp",
+ "@id": "urn:ex/vav-514-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-514-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-514-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-514-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-109-temp",
+ "@id": "urn:ex/vav-521-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-521-air-in"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-531-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-531-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-531-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-505-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-505-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12102,138 +11615,98 @@
]
},
{
- "@id": "urn:ex/room-310-out",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-537-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-537-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-516-heating-pid-output",
+ "@id": "urn:ex/vav-511-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Outside",
- "@type": [
- "http://data.ashrae.org/standard223#EnumerationKind-Role"
- ]
- },
- {
- "@id": "urn:ex/vav-506-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-207-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-flow-setpoint",
+ "@id": "urn:ex/room-112",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/room-112-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-520-damper",
+ "@id": "urn:ex/vav-531-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-damper-in"
+ "@id": "urn:ex/vav-531-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-520-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-520-damper-command"
+ "@id": "urn:ex/vav-531-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-520-damper-position"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-503-heating-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-532-reheat-coil-valve-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-531-reheat-coil-water-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-531-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/room-303-out",
+ "@id": "urn:ex/vav-527-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-527-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12243,45 +11716,48 @@
]
},
{
- "@id": "urn:ex/vav-514-heating-pid-output",
+ "@id": "urn:ex/zone-110-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-201-occupancy-sensor",
+ "@id": "urn:ex/room-101-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-201-hvac-domain"
+ "@id": "urn:ex/room-101-in"
+ },
+ {
+ "@id": "urn:ex/room-101-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/zone-201-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-536-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-536-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12291,129 +11767,113 @@
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve"
+ "@id": "urn:ex/vav-539-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/room-312-out",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-air-in",
+ "@id": "urn:ex/room-112-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-duct-after-damper"
+ "@id": "urn:ex/room-112-in"
+ },
+ {
+ "@id": "urn:ex/room-112-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-521-heating-pid-output",
+ "@id": "urn:ex/vav-522-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-506-discharge-air-flow-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-506-air-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/vav-506-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-temp",
+ "@id": "urn:ex/vav-509-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-516-more-heat-requests",
+ "@id": "urn:ex/zone-305-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-305-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-305-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-307-308",
+ "@id": "urn:ex/zone-201",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-307-hvac-domain"
- },
- {
- "@id": "urn:ex/room-308-hvac-domain"
+ "@id": "urn:ex/room-201-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -12423,125 +11883,63 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-307-308-cooling-setpoint"
+ "@id": "urn:ex/zone-201-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-307-308-heating-setpoint"
+ "@id": "urn:ex/zone-201-heating-setpoint"
},
{
- "@id": "urn:ex/zone-307-308-occupancy"
+ "@id": "urn:ex/zone-201-occupancy"
},
{
- "@id": "urn:ex/zone-307-308-occupancy-override"
+ "@id": "urn:ex/zone-201-occupancy-override"
},
{
- "@id": "urn:ex/zone-307-308-temp"
+ "@id": "urn:ex/zone-201-temp"
},
{
- "@id": "urn:ex/zone-307-308-window-switch-on-off"
+ "@id": "urn:ex/zone-201-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-538-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-509-air-out"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-discharge-air-temp"
+ "@id": "urn:ex/connection-to-room-213"
}
- ]
- },
- {
- "@id": "urn:ex/vav-527-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-reheat-coil-air-in"
+ "@id": "urn:ex/vav-538-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-524-reheat-coil-air-out"
+ "@id": "urn:ex/vav-538-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-524-reheat-coil-water-in"
+ "@id": "urn:ex/vav-538-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-524-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-508-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-540-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-106-107-occupancy-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-106-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/zone-106-107-occupancy"
+ "@id": "urn:ex/vav-538-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-air-out",
+ "@id": "urn:ex/vav-539-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-305"
+ "@id": "urn:ex/vav-539-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -12551,67 +11949,41 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-533-heating-pid-output"
+ "@id": "urn:ex/vav-539-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-533-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-533-air-out"
+ "@id": "urn:ex/vav-539-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-507-damper",
+ "@id": "urn:ex/vav-540-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-damper-in"
+ "@id": "urn:ex/vav-540-damper-in"
},
{
- "@id": "urn:ex/vav-507-damper-out"
+ "@id": "urn:ex/vav-540-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-507-damper-command"
+ "@id": "urn:ex/vav-540-damper-command"
},
{
- "@id": "urn:ex/vav-507-damper-position"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-305-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-305-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/zone-305-temp"
+ "@id": "urn:ex/vav-540-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp",
+ "@id": "urn:ex/zone-312-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -12624,61 +11996,63 @@
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil",
+ "@id": "urn:ex/zone-106-107",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-506-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-506-reheat-coil-air-out"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-506-reheat-coil-water-in"
+ "@id": "urn:ex/room-106-hvac-domain"
},
{
- "@id": "urn:ex/vav-506-reheat-coil-water-out"
+ "@id": "urn:ex/room-107-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-540-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-106-107-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-occupancy"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-106-107-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-temp"
+ },
+ {
+ "@id": "urn:ex/zone-106-107-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-540-cooling-pid-output",
+ "@id": "urn:ex/vav-507-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-204-205-temp",
+ "@id": "urn:ex/zone-305-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -12694,71 +12068,76 @@
]
},
{
- "@id": "urn:ex/vav-539-hot-water-out",
+ "@id": "urn:ex/room-312-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-312"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-104-temp",
+ "@id": "urn:ex/vav-522-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-522-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-522-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-103-temp",
+ "@id": "urn:ex/zone-302-co2-concentration-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#ofSubstance": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-507-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-539-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-539-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-208-209-occupancy",
+ "@id": "urn:ex/zone-116-117-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -12769,39 +12148,37 @@
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-water-out",
+ "@id": "urn:ex/vav-503-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-104"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-526-discharge-air-flow-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-526-air-in"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/vav-503-discharge-air-flow"
+ },
{
- "@id": "urn:ex/vav-526-discharge-air-flow"
+ "@id": "urn:ex/vav-503-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-503-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-503-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-301-heating-setpoint",
+ "@id": "urn:ex/zone-307-308-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -12817,145 +12194,130 @@
]
},
{
- "@id": "urn:ex/room-301",
+ "@id": "urn:ex/zone-313-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-301-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-525-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-525-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-213-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/connection-to-room-213"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-525-colder-supply-air-requests"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-525-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-311-cooling-setpoint",
+ "@id": "urn:ex/office-ahu-sa-fan-speed-cmd",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve",
+ "@id": "urn:ex/vav-535-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-536-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-535-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-535-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-535-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/room-208-in",
+ "@id": "urn:ex/zone-210-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-208-209"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-314-hvac-domain",
+ "@id": "urn:ex/vav-530",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-314-in"
+ "@id": "urn:ex/vav-530-air-in"
},
{
- "@id": "urn:ex/room-314-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "@id": "urn:ex/vav-530-air-out"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-534-hot-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-530-hot-water-in"
+ },
{
- "@id": "urn:ex/vav-534-hot-water-out-connection"
+ "@id": "urn:ex/vav-530-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-530-damper"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-530-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -12967,98 +12329,77 @@
]
},
{
- "@id": "urn:ex/zone-105-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-105-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/zone-105-temp"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-311-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-104-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-536-air-in",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-503-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-water-in",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-509-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-509-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-528-air-in",
+ "@id": "urn:ex/vav-504-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-504-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13068,158 +12409,114 @@
]
},
{
- "@id": "urn:ex/vav-518-hot-water-out-connection",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/vav-540-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-flow",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-513-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-513-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-530-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-540-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-501-air-in"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-501-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-air-in",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-duct-after-damper"
+ "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-309-310-cooling-setpoint",
+ "@id": "urn:ex/vav-505-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-508-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-519-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-203-heating-setpoint",
+ "@id": "urn:ex/zone-314-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -13235,216 +12532,108 @@
]
},
{
- "@id": "urn:ex/zone-213-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
- }
- ]
- },
- {
- "@id": "urn:ex/room-209-out",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-512-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-512-damper-in"
- },
- {
- "@id": "urn:ex/vav-512-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-512-damper-command"
- },
- {
- "@id": "urn:ex/vav-512-damper-position"
+ "@id": "urn:ex/vav-535-hot-water-out-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-506-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-210",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-535-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-in",
+ "@id": "urn:ex/vav-527-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-516-air-in"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-521-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-temp",
+ "@id": "urn:ex/vav-523-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-210-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-208-209-heating-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-509-damper-actuator",
+ "@id": "urn:ex/vav-522-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-509-damper"
+ "@id": "urn:ex/vav-522-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-509-damper-command"
+ "@id": "urn:ex/vav-522-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-503-damper",
+ "@id": "urn:ex/room-104-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-damper-in"
- },
- {
- "@id": "urn:ex/vav-503-damper-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-503-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-503-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-519-heating-pid-output",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-530-hot-water-out-connection",
+ "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -13456,29 +12645,37 @@
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-501-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-506-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-hot-water-out-connection"
+ "@id": "urn:ex/vav-504-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13488,110 +12685,113 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-507-hot-water-out"
+ "@id": "urn:ex/vav-504-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-actuator",
+ "@id": "urn:ex/vav-505-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-501-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-505-air-in"
}
]
},
{
- "@id": "urn:ex/vav-502-cooling-pid-output",
+ "@id": "urn:ex/vav-512-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-512-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-214-in",
+ "@id": "urn:ex/vav-512-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-214"
+ "@id": "urn:ex/vav-512-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-307",
+ "@id": "urn:ex/room-102-in",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-307-hvac-domain"
+ "@id": "urn:ex/connection-to-room-102"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-out-connection",
+ "@id": "urn:ex/vav-505-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-533-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-514-air-out"
+ "@id": "urn:ex/vav-533-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-514-discharge-air-temp"
+ "@id": "urn:ex/vav-533-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-510-hot-water-in-connection",
+ "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -13603,14 +12803,46 @@
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-temp",
+ "@id": "urn:ex/zone-118",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/room-118-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-118-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-118-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-118-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-118-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-118-temp"
+ },
+ {
+ "@id": "urn:ex/zone-118-window-switch-on-off"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-109-heating-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -13624,67 +12856,76 @@
]
},
{
- "@id": "urn:ex/vav-502-damper-actuator",
+ "@id": "urn:ex/vav-532-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-502-damper"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-502-damper-command"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-position",
+ "@id": "urn:ex/vav-514-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve",
+ "@id": "urn:ex/vav-513-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-518-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-518-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-531-heating-pid-output",
+ "@id": "urn:ex/vav-516-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -13700,100 +12941,92 @@
]
},
{
- "@id": "urn:ex/room-311-hvac-domain",
+ "@id": "urn:ex/vav-539-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-311-in"
- },
- {
- "@id": "urn:ex/room-311-out"
+ "@id": "urn:ex/vav-539-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/room-314",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "urn:ex/vav-539-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-temp",
+ "@id": "urn:ex/vav-505-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-505-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-505-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-527-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil",
+ "@id": "urn:ex/vav-521-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-521-reheat-coil-air-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-reheat-coil-air-out"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-reheat-coil-water-in"
- },
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-302-window-switch-on-off",
+ "@id": "urn:ex/zone-309-310-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -13804,105 +13037,121 @@
]
},
{
- "@id": "urn:ex/zone-115-temp",
+ "@id": "urn:ex/room-314-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-312-temp-sensor",
+ "@id": "urn:ex/vav-525-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-312-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-312-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-temp",
+ "@id": "urn:ex/vav-536-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-108-occupancy-override",
+ "@id": "urn:ex/zone-104-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-538",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-538-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-538-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-538-damper"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/connection-to-room-202",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-506-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-506-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-518-air-out",
+ "@id": "urn:ex/vav-506-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-202"
+ "@id": "urn:ex/vav-506-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -13912,160 +13161,203 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-518-discharge-air-flow"
+ "@id": "urn:ex/vav-506-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-518-discharge-air-flow-setpoint"
- },
+ "@id": "urn:ex/vav-506-cooling-pid-output"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-518-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-515-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-518-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-515-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/room-207-out",
+ "@id": "urn:ex/vav-510-heating-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-501-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-501-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-516",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-air-in"
- },
+ "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-516-air-out"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-516-hot-water-in"
- },
+ "@id": "urn:ex/vav-506-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-516-hot-water-out"
+ "@id": "urn:ex/vav-506-reheat-coil-valve-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-damper"
- },
+ "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-516-reheat-coil"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-506-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-516-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-509-damper",
+ "@id": "urn:ex/vav-517-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-damper-in"
- },
- {
- "@id": "urn:ex/vav-509-damper-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-509-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-509-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-511-colder-supply-air-requests",
+ "@id": "urn:ex/zone-202-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-307-308-occupancy",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/vav-540-reheat-coil-valve"
}
- ]
- },
- {
- "@id": "urn:ex/zone-302-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/room-111-hvac-domain",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-111-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-111-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-534-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-540-heating-pid-output",
+ "@id": "urn:ex/vav-527-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -14081,113 +13373,83 @@
]
},
{
- "@id": "urn:ex/vav-511-damper-in",
+ "@id": "urn:ex/room-307-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-511-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil",
+ "@id": "urn:ex/vav-518-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-534-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-534-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-534-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-534-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-302",
+ "@id": "urn:ex/vav-501-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "urn:ex/vav-501-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-302-co2-concentration"
- },
- {
- "@id": "urn:ex/zone-302-co2-concentration-setpoint"
- },
- {
- "@id": "urn:ex/zone-302-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-302-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-302-occupancy"
- },
- {
- "@id": "urn:ex/zone-302-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-302-temp"
+ "@id": "urn:ex/vav-501-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/zone-302-window-switch-on-off"
+ "@id": "urn:ex/vav-501-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-505-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-flow",
+ "@id": "urn:ex/vav-519-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -14208,112 +13470,143 @@
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-out-connection",
+ "@id": "urn:ex/office-ahu-oa-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-oa-damper"
}
- ]
- },
- {
- "@id": "urn:ex/vav-538-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-oa-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-command",
+ "@id": "urn:ex/vav-515-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-actuator",
+ "@id": "urn:ex/zone-202",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-ra-damper"
+ "@id": "urn:ex/room-202-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/office-ahu-ra-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-202-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-202-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-202-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-202-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-202-temp"
+ },
+ {
+ "@id": "urn:ex/zone-202-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-511-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-air-out"
+ "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-510-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-515-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-202",
+ "@id": "urn:ex/office-ahu-oa-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-202-hvac-domain"
+ "@id": "urn:ex/office-ahu-oa-damper-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/office-ahu-oa-flow"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-water-out",
+ "@id": "urn:ex/vav-537-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14322,25 +13615,41 @@
]
},
{
- "@id": "urn:ex/vav-536-hot-water-in",
+ "@id": "urn:ex/vav-529",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-hot-water-in-connection"
+ "@id": "urn:ex/vav-529-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-529-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-529-damper"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-529-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-position",
+ "@id": "urn:ex/vav-526-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -14354,148 +13663,166 @@
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp-setpoint",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-307-308-occupancy-sensor",
+ "@id": "urn:ex/vav-526-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-307-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-307-308-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-526-air-in"
}
]
},
{
- "@id": "urn:ex/room-307-out",
+ "@id": "urn:ex/vav-511-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-air-in",
+ "@id": "urn:ex/vav-533-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-duct-after-damper"
+ "@id": "urn:ex/vav-533-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-533-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-533-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp-setpoint",
+ "@id": "urn:ex/office-ahu-clg-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Water-ChilledWater"
}
- ]
- },
- {
- "@id": "urn:ex/zone-215-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-503-damper-command",
+ "@id": "urn:ex/vav-532-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/connection-to-room-113",
+ "@id": "urn:ex/vav-509-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-509-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-509-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-temp-sensor",
+ "@id": "urn:ex/room-211-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-air-out"
+ "@id": "urn:ex/connection-to-room-211"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-531-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-water-in",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-hot-water-in-connection"
+ "@id": "urn:ex/vav-528-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -14505,232 +13832,228 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-537-hot-water-in"
+ "@id": "urn:ex/vav-528-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-529-air-in",
+ "@id": "urn:ex/vav-527-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-ma-temp-sensor",
+ "@id": "urn:ex/vav-510-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-air-filter-in"
+ "@id": "urn:ex/vav-510-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/office-ahu-ma-temp"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-539-hot-water-in",
+ "@id": "urn:ex/zone-105-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-539-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-522-damper",
+ "@id": "urn:ex/vav-520-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-522-damper-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-damper-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-522-damper-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-damper-position"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-519-hot-water-out",
+ "@id": "urn:ex/vav-524-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-hot-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-508-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/connection-to-room-109"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-206",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-508-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-508-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-508-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-508-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-in",
+ "@id": "urn:ex/zone-206-co2-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/room-206-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-206-co2-concentration"
}
]
},
{
- "@id": "urn:ex/vav-530-air-in",
+ "@id": "urn:ex/zone-214-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/room-214-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-214-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-air-in",
+ "@id": "urn:ex/vav-537-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-duct-after-damper"
+ "@id": "urn:ex/vav-537-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-102-in",
+ "@id": "urn:ex/office-ahu-htg-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-102"
+ "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-air-out",
+ "@id": "urn:ex/room-204-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-102"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-501-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-501-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-501-air-out"
- }
]
},
{
- "@id": "urn:ex/vav-534-heating-pid-output",
+ "@id": "urn:ex/vav-526-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-526-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-command",
+ "@id": "urn:ex/vav-511-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -14746,94 +14069,46 @@
]
},
{
- "@id": "urn:ex/vav-535-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-512-damper-actuator",
+ "@id": "urn:ex/vav-503-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-512-damper"
+ "@id": "urn:ex/vav-503-air-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-512-damper-command"
+ "@id": "urn:ex/vav-503-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-out",
+ "@id": "urn:ex/room-301-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-527-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-527-cooling-pid-output"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-525-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-damper-in"
- },
- {
- "@id": "urn:ex/vav-525-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-525-damper-command"
- },
- {
- "@id": "urn:ex/vav-525-damper-position"
- }
]
},
{
- "@id": "urn:ex/zone-211-occupancy",
+ "@id": "urn:ex/vav-515-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/zone-302-temp",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -14847,40 +14122,46 @@
]
},
{
- "@id": "urn:ex/vav-508-damper-actuator",
+ "@id": "urn:ex/zone-206-co2-concentration",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-508-damper"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-damper-command"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/zone-206-occupancy",
+ "@id": "urn:ex/vav-507-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-523-air-out",
+ "@id": "urn:ex/vav-531-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-206"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -14890,96 +14171,82 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-523-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-523-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-531-heating-pid-output"
},
{
- "@id": "urn:ex/vav-523-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-531-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-523-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-531-air-out"
}
]
},
{
- "@id": "urn:ex/room-107-in",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-106-107"
+ "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531",
+ "@id": "urn:ex/vav-510-air-out",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-air-in"
- },
- {
- "@id": "urn:ex/vav-531-air-out"
- },
- {
- "@id": "urn:ex/vav-531-hot-water-in"
- },
+ "@id": "urn:ex/connection-to-room-111"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-531-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-damper"
+ "@id": "urn:ex/vav-510-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-531-reheat-coil"
+ "@id": "urn:ex/vav-510-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-213-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-510-discharge-air-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-510-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil",
+ "@id": "urn:ex/vav-507-reheat-coil",
"@type": [
"http://data.ashrae.org/standard223#HeatingCoil",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-reheat-coil-air-in"
+ "@id": "urn:ex/vav-507-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-538-reheat-coil-air-out"
+ "@id": "urn:ex/vav-507-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-538-reheat-coil-water-in"
+ "@id": "urn:ex/vav-507-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-538-reheat-coil-water-out"
+ "@id": "urn:ex/vav-507-reheat-coil-water-out"
}
],
"http://data.ashrae.org/standard223#hasRole": [
@@ -14989,7 +14256,7 @@
]
},
{
- "@id": "urn:ex/vav-509-cooling-pid-output",
+ "@id": "urn:ex/vav-514-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -15005,49 +14272,23 @@
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil",
+ "@id": "urn:ex/vav-523-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-520-reheat-coil-water-out"
+ "@id": "urn:ex/vav-523-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-529-heating-pid-output",
+ "@id": "urn:ex/vav-534-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -15063,73 +14304,61 @@
]
},
{
- "@id": "urn:ex/vav-536-hot-water-in-connection",
+ "@id": "urn:ex/vav-515-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-515-air-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-510-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-515-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-103-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-515-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-515-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-505-damper-command",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-501-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-501-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-air-in",
+ "@id": "urn:ex/vav-504-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15139,284 +14368,325 @@
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-water-in",
+ "@id": "urn:ex/vav-531-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-526-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-526-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-520-duct-after-damper",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-520-colder-supply-air-requests",
+ "@id": "urn:ex/vav-533-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-211-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-530-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-530-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-212-occupancy",
+ "@id": "urn:ex/vav-539-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-reheat-coil-valve-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-cooling-pid-output",
+ "@id": "urn:ex/vav-524-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-512-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-515-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-515-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-507-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve"
+ "@id": "urn:ex/vav-507-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-507-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-508-hot-water-in-connection",
+ "@id": "urn:ex/zone-112-114-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-in",
+ "@id": "urn:ex/room-309-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-309-310"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-532-hot-water-out-connection",
+ "@id": "urn:ex/vav-521-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-204-205"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-521-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-521-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-temp",
+ "@id": "urn:ex/room-211",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/room-211-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-damper-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-position",
+ "@id": "urn:ex/vav-503-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-504-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-503-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-503-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-damper-command",
+ "@id": "urn:ex/vav-520-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-103-window-switch-on-off",
+ "@id": "urn:ex/zone-103-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-506-air-out",
+ "@id": "urn:ex/vav-521-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-106-107"
+ "@id": "urn:ex/vav-521-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15426,265 +14696,261 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-506-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-506-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-506-discharge-air-temp"
+ "@id": "urn:ex/vav-521-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-506-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-521-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-108-occupancy",
+ "@id": "urn:ex/vav-539-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-hot-water-out-connection",
+ "@id": "urn:ex/vav-506-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-out",
+ "@id": "urn:ex/vav-501-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-duct-after-damper"
+ "@id": "urn:ex/vav-501-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-506-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-506-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-air-filter",
+ "@id": "urn:ex/vav-506-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#AirFilter",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-air-filter-in"
- },
+ "@id": "urn:ex/vav-506-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-air-filter-out"
+ "@id": "urn:ex/vav-506-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-command",
+ "@id": "urn:ex/office-ahu-ra-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-ra-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/office-ahu-ra-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-210-temp-sensor",
+ "@id": "urn:ex/vav-521-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-210-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-210-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-water-in",
+ "@id": "urn:ex/vav-523-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-hot-water-in-connection"
+ "@id": "urn:ex/vav-523-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-504-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve",
+ "@id": "urn:ex/vav-523-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-531-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-523-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-523-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-523-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/room-115",
+ "@id": "urn:ex/vav-517-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-517-air-in"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve",
+ "@id": "urn:ex/vav-539-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-535-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-539-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-heating-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-536-damper",
+ "@id": "urn:ex/vav-537-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-damper-in"
- },
- {
- "@id": "urn:ex/vav-536-damper-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-536-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-536-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-hot-water-out",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-hot-water-out-connection"
+ "@id": "urn:ex/vav-508-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-508-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/room-118-out",
+ "@id": "urn:ex/vav-536-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-536-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-536-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-506-hot-water-in",
+ "@id": "urn:ex/vav-504-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-506-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -15693,56 +14959,63 @@
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-air-in",
+ "@id": "urn:ex/office-ahu-ma-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-530-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil",
+ "@id": "urn:ex/vav-519-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-537-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-537-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-302-in",
+ "@id": "urn:ex/vav-516-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/connection-to-room-302"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-540-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -15751,44 +15024,61 @@
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-out",
+ "@id": "urn:ex/vav-518-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-518-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-518-damper-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-colder-chilled-water-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-sa-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-510-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-510-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-510-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-525-hot-water-out-connection",
+ "@id": "urn:ex/room-307",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "urn:ex/room-307-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -15800,136 +15090,148 @@
]
},
{
- "@id": "urn:ex/zone-311-temp",
+ "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-damper-position",
+ "@id": "urn:ex/vav-522",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-522-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-522-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-522-damper"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-215-temp-sensor",
+ "@id": "urn:ex/room-111-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-215-hvac-domain"
+ "@id": "urn:ex/room-111-in"
+ },
+ {
+ "@id": "urn:ex/room-111-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/zone-215-temp"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-522-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-air-in"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-528-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-314-heating-setpoint",
+ "@id": "urn:ex/room-204-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-535-heating-pid-output",
+ "@id": "urn:ex/zone-116-117-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-116-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/zone-116-117-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-526-air-in",
+ "@id": "urn:ex/office-ahu-chilled-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-105",
+ "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-105-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-538-hot-water-in",
+ "@id": "urn:ex/vav-510-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-hot-water-in-connection"
+ "@id": "urn:ex/vav-510-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15939,165 +15241,206 @@
]
},
{
- "@id": "urn:ex/vav-508-hot-water-out",
+ "@id": "urn:ex/vav-501-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-hot-water-out-connection"
+ "@id": "urn:ex/vav-508-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-command",
+ "@id": "urn:ex/zone-207-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-air-out",
+ "@id": "urn:ex/vav-503",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-214"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-503-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-503-air-out"
+ },
{
- "@id": "urn:ex/vav-539-heating-pid-output"
+ "@id": "urn:ex/vav-503-hot-water-in"
},
{
- "@id": "urn:ex/vav-539-more-heat-requests"
+ "@id": "urn:ex/vav-503-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-539-air-out"
+ "@id": "urn:ex/vav-503-damper"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-503-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-203-temp",
+ "@id": "urn:ex/office-ahu-ra-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-ra-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/office-ahu-ra-flow"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-water-in",
+ "@id": "urn:ex/vav-532-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-514-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-514-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-513-cooling-pid-output",
+ "@id": "urn:ex/zone-112-114-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-306-out",
+ "@id": "urn:ex/vav-538-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-213"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-538-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-538-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-538-air-out"
+ }
]
},
{
- "@id": "urn:ex/vav-524-colder-supply-air-requests",
+ "@id": "urn:ex/vav-534-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-112-114-window-switch-on-off",
+ "@id": "urn:ex/vav-523-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-525-hot-water-out",
+ "@id": "urn:ex/vav-540-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-hot-water-out-connection"
+ "@id": "urn:ex/vav-540-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -16107,220 +15450,221 @@
]
},
{
- "@id": "urn:ex/zone-202-temp-sensor",
+ "@id": "urn:ex/vav-502-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-202-hvac-domain"
+ "@id": "urn:ex/vav-502-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-202-temp"
+ "@id": "urn:ex/vav-502-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve",
+ "@id": "urn:ex/vav-502-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-504-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518-damper-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-504-reheat-coil-valve-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-water-out",
+ "@id": "urn:ex/room-104-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-104"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-537-hot-water-out-connection",
+ "@id": "urn:ex/office-ahu-ra-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534",
+ "@id": "urn:ex/vav-514-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-534-air-in"
- },
- {
- "@id": "urn:ex/vav-534-air-out"
- },
- {
- "@id": "urn:ex/vav-534-hot-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-534-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-534-damper"
- },
- {
- "@id": "urn:ex/vav-534-reheat-coil"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-534-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp",
+ "@id": "urn:ex/vav-536-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-536-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-536-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-air-out",
+ "@id": "urn:ex/office-ahu-duct-after-htg-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/connection-to-room-313"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-533-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-527-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-536-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-536-more-heat-requests"
+ "@id": "urn:ex/vav-527-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-536-air-out"
+ "@id": "urn:ex/vav-527-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-301-occupancy",
+ "@id": "urn:ex/office-ahu-ra-fan-start-status",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-108-temp-sensor",
+ "@id": "urn:ex/vav-533-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-108-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-108-temp"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-511-air-in",
+ "@id": "urn:ex/zone-103-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-203-cooling-setpoint",
+ "@id": "urn:ex/vav-525-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-511-heating-pid-output",
+ "@id": "urn:ex/vav-514-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-530-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -16336,141 +15680,137 @@
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-air-out",
+ "@id": "urn:ex/zone-305",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-307-308"
+ "@id": "urn:ex/room-305-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-heating-pid-output"
+ "@id": "urn:ex/zone-305-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-531-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:ex/zone-305-heating-setpoint"
+ },
{
- "@id": "urn:ex/vav-531-air-out"
+ "@id": "urn:ex/zone-305-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-305-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-305-temp"
+ },
+ {
+ "@id": "urn:ex/zone-305-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-312",
+ "@id": "urn:ex/vav-506",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-312-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-312-cooling-setpoint"
+ "@id": "urn:ex/vav-506-air-in"
},
{
- "@id": "urn:ex/zone-312-heating-setpoint"
+ "@id": "urn:ex/vav-506-air-out"
},
{
- "@id": "urn:ex/zone-312-occupancy"
+ "@id": "urn:ex/vav-506-hot-water-in"
},
{
- "@id": "urn:ex/zone-312-occupancy-override"
+ "@id": "urn:ex/vav-506-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-506-damper"
},
{
- "@id": "urn:ex/zone-312-temp"
+ "@id": "urn:ex/vav-506-reheat-coil"
},
{
- "@id": "urn:ex/zone-312-window-switch-on-off"
+ "@id": "urn:ex/vav-506-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-212-temp",
+ "@id": "urn:ex/vav-504-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-504-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-504-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-529-air-out",
+ "@id": "urn:ex/vav-531-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
+ "@id": "urn:ex/vav-531-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-529-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-529-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-529-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-529-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-actuator",
+ "@id": "urn:ex/vav-526-damper",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-damper"
+ "@id": "urn:ex/vav-526-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-damper-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-539-damper-command"
+ "@id": "urn:ex/vav-526-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-526-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-in",
+ "@id": "urn:ex/office-ahu-ra-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -16478,21 +15818,36 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-538-air-in"
+ "@id": "urn:ex/office-ahu-ra-flow"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-temp"
}
]
},
{
- "@id": "urn:ex/vav-532-hot-water-in",
+ "@id": "urn:ex/vav-514-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-532-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-522-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -16501,127 +15856,143 @@
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-actuator",
+ "@id": "urn:ex/zone-215-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve"
+ "@id": "urn:ex/room-215-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-command"
+ "@id": "urn:ex/zone-215-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-311-heating-setpoint",
+ "@id": "urn:ex/vav-518-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-518-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-518-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-510-cooling-pid-output",
+ "@id": "urn:ex/vav-513-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/connection-to-room-103"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-513-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-513-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-513-discharge-air-temp"
+ },
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-513-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-air-out",
+ "@id": "urn:ex/room-311-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-104"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-503-heating-pid-output"
+ "@id": "urn:ex/room-311-in"
},
{
- "@id": "urn:ex/vav-503-more-heat-requests"
+ "@id": "urn:ex/room-311-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-503-air-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-502-heating-pid-output",
+ "@id": "urn:ex/vav-520-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-flow",
+ "@id": "urn:ex/connection-to-room-210",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-538-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-538-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-538-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-520-hot-water-out",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-hot-water-out-connection"
+ "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -16631,124 +16002,122 @@
]
},
{
- "@id": "urn:ex/office-ahu-increased-air-pressure-requests",
+ "@id": "urn:ex/connection-to-room-102",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-214-heating-setpoint",
+ "@id": "urn:ex/zone-103-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-103-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-103-occupancy"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-air-out",
+ "@id": "urn:ex/zone-201-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-duct-after-htg-coil"
+ "@id": "urn:ex/room-201-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-201-temp"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-flow",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-116-117-temp-sensor",
+ "@id": "urn:ex/zone-201-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-116-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/zone-116-117-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-water-out",
+ "@id": "urn:ex/vav-534-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-534-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-in",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-506-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-113-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -16764,66 +16133,49 @@
]
},
{
- "@id": "urn:ex/zone-101-occupancy-override",
+ "@id": "urn:ex/vav-519-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-528-damper-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-519-reheat-coil-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-519-reheat-coil-air-out"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-524-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-519-reheat-coil-water-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-519-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-117-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-air-in"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-523-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-in",
+ "@id": "urn:ex/vav-514-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -16839,31 +16191,31 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-534-air-in"
+ "@id": "urn:ex/vav-514-air-in"
}
]
},
{
- "@id": "urn:ex/room-110",
+ "@id": "urn:ex/room-211-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-110-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-temp",
+ "@id": "urn:ex/zone-313-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -16876,149 +16228,122 @@
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-flow-setpoint",
+ "@id": "urn:ex/room-107-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/room-107-in"
+ },
+ {
+ "@id": "urn:ex/room-107-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp",
+ "@id": "urn:ex/office-ahu-sa-fan-power",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/W"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-526-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-526-hot-water-out"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-flow-sensor",
+ "@id": "urn:ex/zone-113",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-oa-damper-in"
+ "@id": "urn:ex/room-113-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/office-ahu-oa-flow"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-514",
- "@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-514-air-in"
- },
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-514-air-out"
+ "@id": "urn:ex/zone-113-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-514-hot-water-in"
+ "@id": "urn:ex/zone-113-heating-setpoint"
},
{
- "@id": "urn:ex/vav-514-hot-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-514-damper"
+ "@id": "urn:ex/zone-113-occupancy"
},
{
- "@id": "urn:ex/vav-514-reheat-coil"
+ "@id": "urn:ex/zone-113-occupancy-override"
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve"
- }
- ]
- },
- {
- "@id": "urn:ex/room-118-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-118-in"
+ "@id": "urn:ex/zone-113-temp"
},
{
- "@id": "urn:ex/room-118-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/zone-113-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-524-hot-water-in",
+ "@id": "urn:ex/vav-507-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-hot-water-in-connection"
+ "@id": "urn:ex/vav-507-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-536-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17028,82 +16353,79 @@
]
},
{
- "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/room-213",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-213-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-in",
+ "@id": "urn:ex/vav-511-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-501-air-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-water-in",
+ "@id": "urn:ex/vav-504-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-540-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp",
+ "@id": "urn:ex/vav-516-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-516-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-516-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-516-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-out-connection",
+ "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -17115,9 +16437,9 @@
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-530-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -17131,17 +16453,14 @@
]
},
{
- "@id": "urn:ex/zone-208-209",
+ "@id": "urn:ex/zone-207",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-208-hvac-domain"
- },
- {
- "@id": "urn:ex/room-209-hvac-domain"
+ "@id": "urn:ex/room-207-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -17151,201 +16470,171 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-208-209-cooling-setpoint"
+ "@id": "urn:ex/zone-207-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-208-209-heating-setpoint"
+ "@id": "urn:ex/zone-207-heating-setpoint"
},
{
- "@id": "urn:ex/zone-208-209-occupancy"
+ "@id": "urn:ex/zone-207-occupancy"
},
{
- "@id": "urn:ex/zone-208-209-occupancy-override"
+ "@id": "urn:ex/zone-207-occupancy-override"
},
{
- "@id": "urn:ex/zone-208-209-temp"
+ "@id": "urn:ex/zone-207-temp"
},
{
- "@id": "urn:ex/zone-208-209-window-switch-on-off"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-539-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/zone-207-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-533-air-out",
+ "@id": "urn:ex/vav-533-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-305"
+ "@id": "urn:ex/vav-533-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-533-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-533-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-533-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-533-discharge-air-temp-setpoint"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-504-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-504-damper-in"
- },
- {
- "@id": "urn:ex/vav-504-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-504-damper-command"
- },
- {
- "@id": "urn:ex/vav-504-damper-position"
- }
]
},
{
- "@id": "urn:ex/vav-503-damper-actuator",
+ "@id": "urn:ex/zone-102-temp",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-503-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-503-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-202-occupancy-sensor",
+ "@id": "urn:ex/vav-504-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-202-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-202-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-air-in",
+ "@id": "urn:ex/vav-537-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-temp-sensor",
+ "@id": "urn:ex/vav-527-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-sa-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-sa-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-522-hot-water-in",
+ "@id": "urn:ex/vav-520-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-207"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-520-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-520-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-520-air-out"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve",
+ "@id": "urn:ex/zone-212",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-530-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-out"
+ "@id": "urn:ex/room-212-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-command"
+ "@id": "urn:ex/zone-212-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-212-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-212-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-212-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-212-temp"
+ },
+ {
+ "@id": "urn:ex/zone-212-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/zone-213-temp",
+ "@id": "urn:ex/zone-312-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -17359,66 +16648,105 @@
]
},
{
- "@id": "urn:ex/vav-508-heating-pid-output",
+ "@id": "urn:ex/zone-109-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-212-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-212"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-301-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-516-air-in"
+ "@id": "urn:ex/room-301-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-516-discharge-air-flow"
+ "@id": "urn:ex/zone-301-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-in",
+ "@id": "urn:ex/vav-527",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-527-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-527-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-527-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-527-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-527-damper"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-valve"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-526-hot-water-in",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-hot-water-in-connection"
+ "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17428,187 +16756,135 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-air-out",
+ "@id": "urn:ex/connection-to-room-214",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-101"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-502-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-air-out"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve",
+ "@id": "urn:ex/zone-115-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-537-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/room-115-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-537-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-115-temp"
}
]
},
{
- "@id": "urn:ex/zone-206",
+ "@id": "urn:ex/vav-531-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "urn:ex/vav-531-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-206-co2-concentration"
- },
- {
- "@id": "urn:ex/zone-206-co2-concentration-setpoint"
- },
- {
- "@id": "urn:ex/zone-206-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-206-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-206-occupancy"
- },
- {
- "@id": "urn:ex/zone-206-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-206-temp"
+ "@id": "urn:ex/vav-531-colder-supply-air-requests"
},
{
- "@id": "urn:ex/zone-206-window-switch-on-off"
+ "@id": "urn:ex/vav-531-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-532-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-536-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/room-212",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/room-212-hvac-domain"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-temp",
+ "@id": "urn:ex/vav-532-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-air-out"
+ "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil",
+ "@id": "urn:ex/vav-518-reheat-coil",
"@type": [
"http://data.ashrae.org/standard223#HeatingCoil",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-reheat-coil-air-in"
+ "@id": "urn:ex/vav-518-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-503-reheat-coil-air-out"
+ "@id": "urn:ex/vav-518-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-503-reheat-coil-water-in"
+ "@id": "urn:ex/vav-518-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-503-reheat-coil-water-out"
+ "@id": "urn:ex/vav-518-reheat-coil-water-out"
}
],
"http://data.ashrae.org/standard223#hasRole": [
@@ -17618,63 +16894,75 @@
]
},
{
- "@id": "urn:ex/zone-202",
+ "@id": "urn:ex/vav-535-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-202-hvac-domain"
+ "@id": "urn:ex/vav-535-air-in"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-535-discharge-air-flow"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-202-cooling-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-202-heating-setpoint"
- },
+ "@id": "urn:ex/connection-to-room-312"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-202-occupancy"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-202-occupancy-override"
+ "@id": "urn:ex/vav-537-heating-pid-output"
},
{
- "@id": "urn:ex/zone-202-temp"
- },
+ "@id": "urn:ex/vav-537-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-202-window-switch-on-off"
+ "@id": "urn:ex/vav-537-air-out"
}
]
},
{
- "@id": "urn:ex/zone-101-heating-setpoint",
+ "@id": "urn:ex/vav-529-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-529-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-512-duct-after-damper",
+ "@id": "urn:ex/room-209-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-208-209"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -17683,41 +16971,55 @@
]
},
{
- "@id": "urn:ex/zone-213-window-switch-on-off",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-522-cooling-pid-output",
+ "@id": "urn:ex/room-211-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-211-in"
+ },
+ {
+ "@id": "urn:ex/room-211-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp",
+ "@id": "urn:ex/office-ahu-increased-air-pressure-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-temp-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -17731,86 +17033,63 @@
]
},
{
- "@id": "urn:ex/vav-511-damper-actuator",
+ "@id": "urn:ex/vav-517-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-511-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-511-damper-command"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-538-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-515-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-538-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-538-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-515-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-311-temp-sensor",
+ "@id": "urn:ex/vav-501-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-311-hvac-domain"
+ "@id": "urn:ex/vav-501-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-311-temp"
+ "@id": "urn:ex/vav-501-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-in",
+ "@id": "urn:ex/vav-521-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -17819,86 +17098,77 @@
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil",
+ "@id": "urn:ex/zone-303-304-306-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil-water-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-water-in",
+ "@id": "urn:ex/vav-511-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-525-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-202-cooling-setpoint",
+ "@id": "urn:ex/vav-506-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-520",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-520-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-520-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-520-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-520-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-520-damper"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-528-hot-water-out-connection",
+ "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -17910,78 +17180,77 @@
]
},
{
- "@id": "urn:ex/vav-526-cooling-pid-output",
+ "@id": "urn:ex/office-ahu-sa-fan-start-status",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-504-heating-pid-output",
+ "@id": "urn:ex/vav-524-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-521-reheat-coil-water-in",
+ "@id": "urn:ex/vav-516-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-521-hot-water-in"
+ "@id": "urn:ex/vav-516-air-in"
}
]
},
{
- "@id": "urn:ex/vav-514-hot-water-in-connection",
+ "@id": "urn:ex/vav-539-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-539-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-539-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-533-hot-water-in",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-hot-water-in-connection"
+ "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -17991,207 +17260,178 @@
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-air-in",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-duct-after-air-filter"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-air-out",
+ "@id": "urn:ex/vav-507-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-314"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-534-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-534-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-534-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-534-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-actuator",
+ "@id": "urn:ex/zone-102-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-oa-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-oa-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-water-out",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-512-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-ra-flow",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Return"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-512-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-536",
+ "@id": "urn:ex/office-ahu-clg-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#CoolingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#ChilledWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-air-in"
+ "@id": "urn:ex/office-ahu-clg-coil-air-in"
},
{
- "@id": "urn:ex/vav-536-air-out"
+ "@id": "urn:ex/office-ahu-clg-coil-air-out"
},
{
- "@id": "urn:ex/vav-536-hot-water-in"
+ "@id": "urn:ex/office-ahu-clg-coil-water-in"
},
{
- "@id": "urn:ex/vav-536-hot-water-out"
+ "@id": "urn:ex/office-ahu-clg-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-536-damper"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523-hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-reheat-coil"
- },
+ "@id": "urn:ex/vav-523-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-536-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-213",
+ "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-213-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-position",
+ "@id": "urn:ex/office-ahu-oa-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-503-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil",
+ "@id": "urn:ex/vav-512-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-510-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-510-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/connection-to-room-303-304-306",
+ "@id": "urn:ex/vav-517-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -18203,19 +17443,46 @@
]
},
{
- "@id": "urn:ex/vav-537-duct-after-damper",
+ "@id": "urn:ex/vav-513-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-flow",
+ "@id": "urn:ex/vav-529-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-529-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-529-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-529-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-529-damper-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-527-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -18236,71 +17503,74 @@
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-speed-cmd",
+ "@id": "urn:ex/vav-525-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-actuator",
+ "@id": "urn:ex/vav-513-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-536-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-536-damper-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-311-occupancy-sensor",
+ "@id": "urn:ex/connection-to-room-212",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-311-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-311-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-water-out",
+ "@id": "urn:ex/vav-505-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-505-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-505-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-505-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-505-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-511-hot-water-out-connection",
+ "@id": "urn:ex/vav-540-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -18312,191 +17582,176 @@
]
},
{
- "@id": "urn:ex/vav-535-cooling-pid-output",
+ "@id": "urn:ex/connection-to-room-206",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-313-out",
+ "@id": "urn:ex/vav-506-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-506-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-506-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-512-hot-water-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-512-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-506-reheat-coil-valve-command"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-506-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-water-out",
+ "@id": "urn:ex/zone-303-304-306-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/room-303-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-303-304-306-temp"
}
]
},
{
- "@id": "urn:ex/vav-507-air-out",
+ "@id": "urn:ex/vav-536-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-110"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-536-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-536-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-507-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-507-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-507-discharge-air-temp"
+ "@id": "urn:ex/vav-536-damper-command"
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-536-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-523-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-504-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-206-hvac-domain",
+ "@id": "urn:ex/vav-522-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-206-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-206-out"
+ "@id": "urn:ex/vav-522-air-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-522-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-flow",
+ "@id": "urn:ex/vav-536-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-damper-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper",
+ "@id": "urn:ex/vav-514-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-oa-damper-in"
+ "@id": "urn:ex/vav-514-damper-in"
},
{
- "@id": "urn:ex/office-ahu-oa-damper-out"
+ "@id": "urn:ex/vav-514-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/office-ahu-oa-damper-command"
- },
- {
- "@id": "urn:ex/office-ahu-oa-damper-position"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Economizer"
+ "@id": "urn:ex/vav-514-damper-command"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ "@id": "urn:ex/vav-514-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-517-hot-water-in-connection",
+ "@id": "urn:ex/vav-506-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18505,63 +17760,65 @@
]
},
{
- "@id": "urn:ex/zone-101-window-switch-on-off",
+ "@id": "urn:ex/vav-530-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-530-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-530-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-530-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-506-heating-pid-output",
+ "@id": "urn:ex/zone-207-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil",
+ "@id": "urn:ex/zone-118-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-540-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil-water-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-503-hot-water-in-connection",
+ "@id": "urn:ex/vav-535-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-535-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18570,7 +17827,7 @@
]
},
{
- "@id": "urn:ex/vav-522-hot-water-out-connection",
+ "@id": "urn:ex/vav-527-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -18582,97 +17839,64 @@
]
},
{
- "@id": "urn:ex/vav-518",
+ "@id": "urn:ex/vav-528-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-air-in"
- },
- {
- "@id": "urn:ex/vav-518-air-out"
- },
- {
- "@id": "urn:ex/vav-518-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-518-hot-water-out"
+ "@id": "urn:ex/vav-528-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-518-damper"
- },
- {
- "@id": "urn:ex/vav-518-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-302-co2-concentration",
+ "@id": "urn:ex/vav-514-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#ofSubstance": [
- {
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-528-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve"
+ "@id": "urn:ex/vav-528-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-528-damper-command"
}
]
},
{
- "@id": "urn:ex/room-203-hvac-domain",
+ "@id": "urn:ex/room-210-hvac-domain",
"@type": [
"http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-203-in"
+ "@id": "urn:ex/room-210-in"
},
{
- "@id": "urn:ex/room-203-out"
+ "@id": "urn:ex/room-210-out"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -18682,140 +17906,189 @@
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp",
+ "@id": "urn:ex/vav-527-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil-water-in"
- },
+ "@id": "urn:ex/vav-519-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-504-reheat-coil-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-519-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-116-117-temp",
+ "@id": "urn:ex/vav-508-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-528-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-302-out",
+ "@id": "urn:ex/vav-522-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-522-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-522-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-522-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/vav-530-colder-supply-air-requests",
+ "@id": "urn:ex/vav-503-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-503-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-flow",
+ "@id": "urn:ex/vav-532-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ "@id": "urn:ex/vav-532-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-110",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/room-110-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-533-damper-out",
+ "@id": "urn:ex/zone-302-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-110"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -18825,15 +18098,21 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-533-colder-supply-air-requests"
+ "@id": "urn:ex/vav-507-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-533-cooling-pid-output"
+ "@id": "urn:ex/vav-507-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-507-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-507-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-309-310-heating-setpoint",
+ "@id": "urn:ex/office-ahu-sa-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -18849,167 +18128,214 @@
]
},
{
- "@id": "urn:ex/room-212-out",
+ "@id": "urn:ex/zone-112-114",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/room-112-hvac-domain"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-114-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-528-hot-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-528-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-112-114-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-temp"
+ },
+ {
+ "@id": "urn:ex/zone-112-114-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-air-out",
+ "@id": "urn:ex/office-ahu-sa-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-213"
+ "@id": "urn:ex/office-ahu-sa-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-sa-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-538-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-538-more-heat-requests"
+ "@id": "urn:ex/vav-525-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-538-air-out"
+ "@id": "urn:ex/vav-525-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-flow",
+ "@id": "urn:ex/zone-105",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/room-105-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/zone-105-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-105-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-105-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-105-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-105-temp"
+ },
+ {
+ "@id": "urn:ex/zone-105-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-531-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-531-air-in"
}
]
},
{
- "@id": "urn:ex/room-115-hvac-domain",
+ "@id": "urn:ex/vav-531-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-115-in"
- },
+ "@id": "urn:ex/vav-531-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-115-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-531-hot-water-in"
}
]
},
{
- "@id": "urn:ex/room-114-out",
+ "@id": "urn:ex/vav-529-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-529-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-529-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-529-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/zone-305-occupancy-override",
+ "@id": "urn:ex/zone-103-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-actuator",
+ "@id": "urn:ex/vav-507-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve"
+ "@id": "urn:ex/vav-507-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-512-cooling-pid-output",
+ "@id": "urn:ex/vav-535-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -19025,104 +18351,117 @@
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-506-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-air-in"
+ "@id": "urn:ex/vav-506-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-530-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-air-in",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-531-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-531-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-109-cooling-setpoint",
+ "@id": "urn:ex/vav-533-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-533-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-313-heating-setpoint",
+ "@id": "urn:ex/vav-532-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-532-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-532-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-532-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-111-occupancy-sensor",
+ "@id": "urn:ex/zone-311-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "urn:ex/room-311-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-111-occupancy"
+ "@id": "urn:ex/zone-311-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-105-occupancy-override",
+ "@id": "urn:ex/vav-516-air-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-516-air-out",
+ "@id": "urn:ex/vav-539-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-201"
+ "@id": "urn:ex/connection-to-room-214"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -19132,23 +18471,22 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-516-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-516-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-539-heating-pid-output"
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-539-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-516-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-539-air-out"
}
]
},
{
- "@id": "urn:ex/zone-313-temp",
+ "@id": "urn:ex/zone-101-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -19162,79 +18500,97 @@
]
},
{
- "@id": "urn:ex/zone-101-co2-concentration-setpoint",
+ "@id": "urn:ex/vav-535-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#ofSubstance": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "urn:ex/vav-535-air-in"
}
]
},
{
- "@id": "urn:ex/room-304",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-304-hvac-domain"
+ "@id": "urn:ex/vav-522-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-518-heating-pid-output",
+ "@id": "urn:ex/vav-507-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-509-damper-out",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-duct-after-damper"
+ "@id": "urn:ex/vav-533-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-509-colder-supply-air-requests"
- },
+ "@id": "urn:ex/vav-533-hot-water-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-509-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-116-out",
+ "@id": "urn:ex/room-305-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -19250,51 +18606,50 @@
]
},
{
- "@id": "urn:ex/connection-to-room-105",
+ "@id": "urn:ex/vav-510-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-510-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-cooling-pid-output",
+ "@id": "urn:ex/room-314",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/room-314-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-air-in",
+ "@id": "urn:ex/vav-512-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-duct-after-damper"
+ "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-525-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -19306,103 +18661,89 @@
]
},
{
- "@id": "urn:ex/vav-533-damper-in",
+ "@id": "urn:ex/vav-525-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-533-air-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-303-in",
+ "@id": "urn:ex/room-101",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-303-304-306"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-101-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-actuator",
+ "@id": "urn:ex/zone-302-co2-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-524-damper"
+ "@id": "urn:ex/room-302-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-524-damper-command"
+ "@id": "urn:ex/zone-302-co2-concentration"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306",
+ "@id": "urn:ex/vav-512-damper",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-303-hvac-domain"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-304-hvac-domain"
+ "@id": "urn:ex/vav-512-damper-in"
},
{
- "@id": "urn:ex/room-306-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-512-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-303-304-306-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-303-304-306-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-303-304-306-occupancy"
+ "@id": "urn:ex/vav-512-damper-command"
},
{
- "@id": "urn:ex/zone-303-304-306-occupancy-override"
- },
+ "@id": "urn:ex/vav-512-damper-position"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-515-heating-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-303-304-306-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-303-304-306-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-507-heating-pid-output",
+ "@id": "urn:ex/vav-524-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -19418,103 +18759,103 @@
]
},
{
- "@id": "urn:ex/zone-211-temp",
+ "@id": "urn:ex/vav-517-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-513-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-513-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-102-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-529-air-in"
+ "@id": "urn:ex/room-102-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-529-discharge-air-flow"
+ "@id": "urn:ex/zone-102-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-water-out",
+ "@id": "urn:ex/room-212-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-actuator",
+ "@id": "urn:ex/zone-206-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-517-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-517-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-214-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-colder-supply-air-requests",
+ "@id": "urn:ex/vav-512-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -19525,345 +18866,272 @@
]
},
{
- "@id": "urn:ex/room-202-hvac-domain",
+ "@id": "urn:ex/vav-522-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-202-in"
- },
+ "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-202-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-203",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/room-203-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-air-out",
+ "@id": "urn:ex/vav-540-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-105"
+ "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-204-205-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-504-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-504-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-504-air-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-521-damper",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-521-damper-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-damper-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-521-damper-command"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-damper-position"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-105-window-switch-on-off",
+ "@id": "urn:ex/vav-537-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-water-in",
+ "@id": "urn:ex/vav-535-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-534-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-534-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-533",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-air-out"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/vav-533-air-in"
+ },
{
- "@id": "urn:ex/vav-535-discharge-air-temp"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-505-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-533-air-out"
+ },
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-533-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-533-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-533-damper"
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-103-temp-sensor",
+ "@id": "urn:ex/zone-202-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-103-hvac-domain"
+ "@id": "urn:ex/room-202-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-103-temp"
+ "@id": "urn:ex/zone-202-temp"
}
]
},
{
- "@id": "urn:ex/zone-305-cooling-setpoint",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-510-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-510-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-314-occupancy-sensor",
+ "@id": "urn:ex/vav-504-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-314-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-314-occupancy"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-207-cooling-setpoint",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-507-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-507-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-out",
+ "@id": "urn:ex/connection-to-room-111",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-523-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-523-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-in",
+ "@id": "urn:ex/vav-507-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-507-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-514-air-in"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-501-heating-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-507-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-actuator",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-514-damper"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
- {
- "@id": "urn:ex/vav-514-damper-command"
- }
- ]
- },
- {
- "@id": "urn:ex/room-210-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-210-in"
- },
- {
- "@id": "urn:ex/room-210-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-213",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-207",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-511-reheat-coil-valve"
+ }
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-511-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-air-in",
+ "@id": "urn:ex/room-210-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-210"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -19873,163 +19141,167 @@
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-201-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-525-air-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-107",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-525-discharge-air-flow"
+ "@id": "urn:ex/room-107-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-513-hot-water-out",
+ "@id": "urn:ex/zone-109-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-513-hot-water-out-connection"
+ "@id": "urn:ex/room-109-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-109-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-507-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-505-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-501-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-hot-water-out-connection"
+ "@id": "urn:ex/vav-501-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-535-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-actuator",
+ "@id": "urn:ex/zone-116-117-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/office-ahu-htg-coil-valve"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-504-duct-after-damper",
+ "@id": "urn:ex/vav-525-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-air-in",
+ "@id": "urn:ex/office-ahu-ra-fan-speed-cmd",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-526-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-312",
+ "@id": "urn:ex/zone-214-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-312-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/zone-211-temp-sensor",
+ "@id": "urn:ex/room-108-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-211-hvac-domain"
+ "@id": "urn:ex/room-108-in"
+ },
+ {
+ "@id": "urn:ex/room-108-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/zone-211-temp"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-538-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -20041,77 +19313,107 @@
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-115-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-505-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-109-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-215-in",
+ "@id": "urn:ex/vav-528-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-215"
+ "@id": "urn:ex/vav-528-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-528-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-water-out",
+ "@id": "urn:ex/vav-526-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-509-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/room-211",
+ "@id": "urn:ex/vav-523-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-211-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-out",
+ "@id": "urn:ex/zone-314-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-528-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-duct-after-damper"
+ "@id": "urn:ex/vav-528-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20121,54 +19423,69 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-538-colder-supply-air-requests"
+ "@id": "urn:ex/vav-528-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-538-cooling-pid-output"
+ "@id": "urn:ex/vav-528-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-507-duct-after-damper",
+ "@id": "urn:ex/vav-512-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-512-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-512-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-111-window-switch-on-off",
+ "@id": "urn:ex/vav-502-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-312-temp",
+ "@id": "urn:ex/vav-532-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-532-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-108-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -20184,130 +19501,129 @@
]
},
{
- "@id": "urn:ex/vav-516-air-in",
+ "@id": "urn:ex/zone-111-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-water-in",
+ "@id": "urn:ex/vav-508-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-202",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-527-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-504",
+ "@id": "urn:ex/vav-505-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-air-in"
+ "@id": "urn:ex/vav-505-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-504-air-out"
+ "@id": "urn:ex/vav-505-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-504-hot-water-in"
+ "@id": "urn:ex/vav-505-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-504-hot-water-out"
+ "@id": "urn:ex/vav-505-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-504-damper"
- },
- {
- "@id": "urn:ex/vav-504-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-504-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-106-107-cooling-setpoint",
+ "@id": "urn:ex/room-104-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-104-in"
+ },
+ {
+ "@id": "urn:ex/room-104-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-position",
+ "@id": "urn:ex/vav-507-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-203-occupancy-sensor",
+ "@id": "urn:ex/zone-201-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-203-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-203-occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-527-air-out",
+ "@id": "urn:ex/vav-505-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-301"
+ "@id": "urn:ex/vav-505-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20317,97 +19633,105 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-527-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-527-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-527-discharge-air-temp"
+ "@id": "urn:ex/vav-505-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-505-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/connection-to-room-214",
+ "@id": "urn:ex/zone-312-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-510-damper-out",
+ "@id": "urn:ex/vav-503-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-109",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-510-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-510-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-210-occupancy-sensor",
+ "@id": "urn:ex/office-ahu-ea-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-210-hvac-domain"
+ "@id": "urn:ex/office-ahu-duct-after-ra-fan"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-210-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-214",
+ "@id": "urn:ex/office-ahu-ea-damper",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-214-hvac-domain"
+ "@id": "urn:ex/office-ahu-ea-damper-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-202-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/office-ahu-ea-damper-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper-position"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Exhaust"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-524-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -20421,139 +19745,144 @@
]
},
{
- "@id": "urn:ex/room-103-in",
+ "@id": "urn:ex/vav-508-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-103"
+ "@id": "urn:ex/vav-508-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-213-cooling-setpoint",
+ "@id": "urn:ex/zone-312-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-312-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-312-temp"
}
]
},
{
- "@id": "urn:ex/zone-101-co2-concentration",
+ "@id": "urn:ex/vav-505-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#ofSubstance": [
- {
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
- }
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-505-reheat-coil-valve-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "urn:ex/vav-505-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-524-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-524-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-damper-command"
+ "@id": "urn:ex/vav-505-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-524-damper-position"
+ "@id": "urn:ex/vav-505-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-529-hot-water-in-connection",
+ "@id": "urn:ex/vav-528-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-505-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-516-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-516-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-air-in",
+ "@id": "urn:ex/vav-530-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-530-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-530-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-530-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-530-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/zone-201",
+ "@id": "urn:ex/zone-208-209",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-201-hvac-domain"
+ "@id": "urn:ex/room-208-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-209-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -20563,144 +19892,159 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-201-cooling-setpoint"
+ "@id": "urn:ex/zone-208-209-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-201-heating-setpoint"
+ "@id": "urn:ex/zone-208-209-heating-setpoint"
},
{
- "@id": "urn:ex/zone-201-occupancy"
+ "@id": "urn:ex/zone-208-209-occupancy"
},
{
- "@id": "urn:ex/zone-201-occupancy-override"
+ "@id": "urn:ex/zone-208-209-occupancy-override"
},
{
- "@id": "urn:ex/zone-201-temp"
+ "@id": "urn:ex/zone-208-209-temp"
},
{
- "@id": "urn:ex/zone-201-window-switch-on-off"
+ "@id": "urn:ex/zone-208-209-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-526-hot-water-out",
+ "@id": "urn:ex/vav-519-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-519-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-505-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-501-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-513-colder-supply-air-requests",
+ "@id": "urn:ex/zone-113-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-113-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-113-temp"
}
]
},
{
- "@id": "urn:ex/vav-532-damper-out",
+ "@id": "urn:ex/room-117-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-532-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-532-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/vav-524-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-308",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-524-air-in"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-524-discharge-air-flow"
+ "@id": "urn:ex/room-308-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-106-107-occupancy",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-occupancy",
+ "@id": "urn:ex/zone-203-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-in",
+ "@id": "urn:ex/vav-535-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -20713,172 +20057,185 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-524-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-538-damper",
+ "@id": "urn:ex/room-302",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-538-damper-in"
- },
- {
- "@id": "urn:ex/vav-538-damper-out"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-538-damper-command"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-538-damper-position"
+ "@id": "urn:ex/room-302-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-512-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve",
+ "@id": "urn:ex/zone-313",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-reheat-coil-valve-in"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-out"
+ "@id": "urn:ex/room-313-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-command"
+ "@id": "urn:ex/zone-313-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-313-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-313-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-313-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-313-temp"
+ },
+ {
+ "@id": "urn:ex/zone-313-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-air-out",
+ "@id": "urn:ex/vav-535-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-314"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-534-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-534-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-534-air-out"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-air-in",
+ "@id": "urn:ex/vav-511-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-520-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-302-occupancy-sensor",
+ "@id": "urn:ex/zone-210-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-302-occupancy"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-301-window-switch-on-off",
+ "@id": "urn:ex/room-101-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-211-out",
+ "@id": "urn:ex/vav-525-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-211"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-525-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-525-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-525-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-525-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-507-damper-command",
+ "@id": "urn:ex/vav-521-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -20892,110 +20249,151 @@
]
},
{
- "@id": "urn:ex/vav-524",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-air-in"
- },
- {
- "@id": "urn:ex/vav-524-air-out"
- },
- {
- "@id": "urn:ex/vav-524-hot-water-in"
- },
+ "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-damper"
- },
+ "@id": "urn:ex/vav-501-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-524-reheat-coil"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve"
+ "@id": "urn:ex/vav-501-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/room-313-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-313"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-hot-water-out",
+ "@id": "urn:ex/room-117-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-hot-water-out-connection"
+ "@id": "urn:ex/room-117-in"
+ },
+ {
+ "@id": "urn:ex/room-117-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/room-116",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-116-hvac-domain"
+ "@id": "urn:ex/vav-520-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-water-in",
+ "@id": "urn:ex/vav-524-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-524-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-524-damper-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-540-damper-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-hot-water-in-connection"
+ "@id": "urn:ex/vav-540-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-hot-water-in"
+ "@id": "urn:ex/vav-540-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-540-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-528-more-heat-requests",
+ "@id": "urn:ex/vav-502-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-502-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-533-hot-water-in-connection",
+ "@id": "urn:ex/vav-505-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -21007,275 +20405,301 @@
]
},
{
- "@id": "urn:ex/room-308-out",
+ "@id": "urn:ex/vav-525-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-525-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-214",
+ "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-214-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-530-cooling-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-214-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-214-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-214-occupancy"
- },
- {
- "@id": "urn:ex/zone-214-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-214-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-214-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "@id": "urn:ex/vav-517-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-water-in",
+ "@id": "urn:ex/vav-529-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-529-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-529-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-529-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-533-air-out"
+ "@id": "urn:ex/vav-529-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-533-discharge-air-temp"
+ "@id": "urn:ex/vav-529-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-position",
+ "@id": "urn:ex/room-103-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-103-in"
+ },
+ {
+ "@id": "urn:ex/room-103-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-302-cooling-setpoint",
+ "@id": "urn:ex/vav-517-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-517-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-flow",
+ "@id": "urn:ex/office-ahu-clg-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/office-ahu-clg-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/office-ahu-clg-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-512",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-512-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-512-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-512-damper"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-503-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-104"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-503-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-503-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-540-hot-water-out"
+ "@id": "urn:ex/vav-503-air-out"
}
]
},
{
- "@id": "urn:ex/vav-503-duct-after-damper",
+ "@id": "urn:ex/zone-302-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-203-occupancy-override",
+ "@id": "urn:ex/vav-505-air-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/connection-to-room-108"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-505-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-505-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-309-310-window-switch-on-off",
+ "@id": "urn:ex/vav-538-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-113-cooling-setpoint",
+ "@id": "urn:ex/vav-533-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-533-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-539-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-in",
+ "@id": "urn:ex/vav-501-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-oa-in-connection"
+ "@id": "urn:ex/connection-to-room-102"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21283,63 +20707,73 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-501-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-501-more-heat-requests"
+ }
+ ],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/office-ahu-oa-in"
+ "@id": "urn:ex/vav-501-air-out"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-temp",
+ "@id": "urn:ex/vav-513-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-513-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-clg-coil",
+ "@id": "urn:ex/room-314-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-314-in"
+ },
+ {
+ "@id": "urn:ex/room-314-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-actuator",
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-position",
+ "@id": "urn:ex/vav-509-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -21355,57 +20789,68 @@
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-flow",
+ "@id": "urn:ex/vav-524-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-502-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-502-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-502-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-503-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-539-colder-supply-air-requests",
+ "@id": "urn:ex/zone-303-304-306-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -21419,78 +20864,92 @@
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve",
+ "@id": "urn:ex/vav-522-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-in"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-valve-out"
+ "@id": "urn:ex/vav-522-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-504-heating-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-511-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve"
+ "@id": "urn:ex/vav-511-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-507-damper-actuator",
+ "@id": "urn:ex/vav-540-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-507-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-507-damper-command"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-208",
+ "@id": "urn:ex/office-ahu-ea-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-208-hvac-domain"
+ "@id": "urn:ex/office-ahu-ea-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-ea-out"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-command",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -21506,103 +20965,100 @@
]
},
{
- "@id": "urn:ex/connection-to-room-211",
+ "@id": "urn:ex/vav-517-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-517-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-533-cooling-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-517-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-526-hot-water-out-connection",
+ "@id": "urn:ex/room-107-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-actuator",
+ "@id": "urn:ex/office-ahu-sa-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-523-damper"
+ "@id": "urn:ex/office-ahu-sa-fan-in"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-523-damper-command"
+ "@id": "urn:ex/office-ahu-sa-flow"
}
]
},
{
- "@id": "urn:ex/vav-515-duct-after-damper",
+ "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-532-hot-water-out",
+ "@id": "urn:ex/vav-538-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-532-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-520-cooling-pid-output",
+ "@id": "urn:ex/vav-505-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -21618,108 +21074,105 @@
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-540-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-540-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-510-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-510-hot-water-out"
- }
]
},
{
- "@id": "urn:ex/vav-512-hot-water-in-connection",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-htg-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-504-air-out",
+ "@id": "urn:ex/vav-511-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-105"
+ "@id": "urn:ex/vav-511-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-511-discharge-air-flow"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-104-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-504-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-504-discharge-air-flow-setpoint"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-504-discharge-air-temp"
- },
+ "@id": "urn:ex/room-104-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-504-discharge-air-temp-setpoint"
+ "@id": "urn:ex/zone-104-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-108-cooling-setpoint",
+ "@id": "urn:ex/vav-533-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-204-in",
+ "@id": "urn:ex/room-304-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21729,174 +21182,159 @@
]
},
{
- "@id": "urn:ex/room-308",
+ "@id": "urn:ex/vav-502-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-308-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-523-damper",
+ "@id": "urn:ex/zone-110-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-523-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-523-damper-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-540-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-523-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-523-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-108",
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-108-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-108-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-108-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-108-occupancy"
- },
- {
- "@id": "urn:ex/zone-108-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-108-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-108-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/zone-213-occupancy-sensor",
+ "@id": "urn:ex/vav-523-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-213-hvac-domain"
+ "@id": "urn:ex/vav-523-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-213-occupancy"
+ "@id": "urn:ex/vav-523-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-532-damper",
+ "@id": "urn:ex/vav-520-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-damper-in"
+ "@id": "urn:ex/vav-520-damper-in"
},
{
- "@id": "urn:ex/vav-532-damper-out"
+ "@id": "urn:ex/vav-520-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-damper-command"
+ "@id": "urn:ex/vav-520-damper-command"
},
{
- "@id": "urn:ex/vav-532-damper-position"
+ "@id": "urn:ex/vav-520-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-517-air-in",
+ "@id": "urn:ex/vav-531-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-205",
+ "@id": "urn:ex/zone-301-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-205-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-314-window-switch-on-off",
+ "@id": "urn:ex/connection-to-room-215",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-speed-status",
+ "@id": "urn:ex/room-210",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/room-210-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-503-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-503-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -21905,7 +21343,7 @@
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -21921,25 +21359,13 @@
]
},
{
- "@id": "urn:ex/vav-539-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-508-damper-in",
+ "@id": "urn:ex/vav-518-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-202"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21947,134 +21373,169 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-518-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-518-more-heat-requests"
+ }
+ ],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-508-air-in"
+ "@id": "urn:ex/vav-518-air-out"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-in",
+ "@id": "urn:ex/vav-506-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-530-air-in"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-513-hot-water-in",
+ "@id": "urn:ex/zone-109-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-513-hot-water-in-connection"
+ "@id": "urn:ex/room-109-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-109-temp"
}
]
},
{
- "@id": "urn:ex/vav-512-hot-water-out-connection",
+ "@id": "urn:ex/zone-210-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve",
+ "@id": "urn:ex/room-103",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-in"
- },
+ "@id": "urn:ex/room-103-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-534-discharge-air-flow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-314",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-113",
+ "@id": "urn:ex/room-113",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#encloses": [
{
"@id": "urn:ex/room-113-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-536-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-514",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-113-cooling-setpoint"
+ "@id": "urn:ex/vav-514-air-in"
},
{
- "@id": "urn:ex/zone-113-heating-setpoint"
+ "@id": "urn:ex/vav-514-air-out"
},
{
- "@id": "urn:ex/zone-113-occupancy"
+ "@id": "urn:ex/vav-514-hot-water-in"
},
{
- "@id": "urn:ex/zone-113-occupancy-override"
+ "@id": "urn:ex/vav-514-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-514-damper"
},
{
- "@id": "urn:ex/zone-113-temp"
+ "@id": "urn:ex/vav-514-reheat-coil"
},
{
- "@id": "urn:ex/zone-113-window-switch-on-off"
+ "@id": "urn:ex/vav-514-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-525-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -22084,61 +21545,57 @@
]
},
{
- "@id": "urn:ex/room-209",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:ex/room-209-hvac-domain"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-512-discharge-air-flow",
+ "@id": "urn:ex/vav-508-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-508-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-508-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-530-cooling-pid-output",
+ "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-311-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-air-out",
+ "@id": "urn:ex/office-ahu-air-filter-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-111"
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -22148,133 +21605,130 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-510-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-510-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-510-air-out"
+ "@id": "urn:ex/office-ahu-ma-temp"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-position",
+ "@id": "urn:ex/office-ahu-ra-fan-power",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/W"
}
]
},
{
- "@id": "urn:ex/vav-511",
+ "@id": "urn:ex/vav-508-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-air-in"
- },
- {
- "@id": "urn:ex/vav-511-air-out"
- },
- {
- "@id": "urn:ex/vav-511-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-511-hot-water-out"
+ "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-511-damper"
- },
- {
- "@id": "urn:ex/vav-511-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-511-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-command",
+ "@id": "urn:ex/zone-208-209-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-514-colder-supply-air-requests",
+ "@id": "urn:ex/vav-528-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-528-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-out",
+ "@id": "urn:ex/vav-505-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
+ "@id": "urn:ex/vav-505-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-505-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-command",
+ "@id": "urn:ex/vav-530-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-530-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-in",
+ "@id": "urn:ex/vav-528-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-206"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -22282,49 +21736,48 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-540-air-in"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-518-damper-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-523-heating-pid-output"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-523-more-heat-requests"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-523-air-out"
}
]
},
{
- "@id": "urn:ex/room-109-hvac-domain",
+ "@id": "urn:ex/vav-537-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-109-in"
+ "@id": "urn:ex/vav-537-reheat-coil-air-in"
},
{
- "@id": "urn:ex/room-109-out"
+ "@id": "urn:ex/vav-537-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-514-more-heat-requests",
+ "@id": "urn:ex/vav-529-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -22335,61 +21788,85 @@
]
},
{
- "@id": "urn:ex/room-205-hvac-domain",
+ "@id": "urn:ex/room-106-hvac-domain",
"@type": [
"http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-205-in"
+ "@id": "urn:ex/room-106-in"
},
{
- "@id": "urn:ex/room-205-out"
+ "@id": "urn:ex/room-106-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-115-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-515-damper-command",
+ "@id": "urn:ex/zone-206-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-206-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-206-temp"
}
]
},
{
- "@id": "urn:ex/connection-to-room-313",
+ "@id": "urn:ex/vav-526-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-212"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-526-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-526-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-526-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-526-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-flow",
+ "@id": "urn:ex/vav-522-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -22403,25 +21880,25 @@
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-521-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-511-air-out"
+ "@id": "urn:ex/vav-521-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-511-discharge-air-temp"
+ "@id": "urn:ex/vav-521-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-525-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -22435,87 +21912,73 @@
]
},
{
- "@id": "urn:ex/vav-502-more-heat-requests",
+ "@id": "urn:ex/vav-521-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-530-hot-water-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-530-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-position",
+ "@id": "urn:ex/vav-521-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-204-205"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-522-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-521-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-521-more-heat-requests"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-521-air-out"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-309-310-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-534-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-534-hot-water-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -22527,44 +21990,73 @@
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-flow",
+ "@id": "urn:ex/vav-540",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-540-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-540-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-540-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-540-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-540-damper"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-valve"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-530-damper",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-air-in"
+ "@id": "urn:ex/vav-530-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-530-damper-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-539-discharge-air-flow"
+ "@id": "urn:ex/vav-530-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-530-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-110-occupancy",
+ "@id": "urn:ex/zone-106-107-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -22575,180 +22067,200 @@
]
},
{
- "@id": "urn:ex/vav-513-heating-pid-output",
+ "@id": "urn:ex/vav-514-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-temp-sensor",
+ "@id": "urn:ex/room-208-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-air-out"
+ "@id": "urn:ex/connection-to-room-208-209"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-534-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-106-107-heating-setpoint",
+ "@id": "urn:ex/vav-529-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-529-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-529-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-309-310-temp",
+ "@id": "urn:ex/vav-506-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-506-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-512-damper-out",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-duct-after-damper"
+ "@id": "urn:ex/vav-532-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-512-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-512-cooling-pid-output"
+ "@id": "urn:ex/vav-532-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-525-damper-position",
+ "@id": "urn:ex/vav-518-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-518-air-in"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-out",
+ "@id": "urn:ex/room-305-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-305"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-105-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-504-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/zone-313-temp-sensor",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-313-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-temp",
+ "@id": "urn:ex/vav-526-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-201",
+ "@id": "urn:ex/vav-505-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-201-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-502-air-in",
+ "@id": "urn:ex/vav-526-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -22764,95 +22276,94 @@
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil",
+ "@id": "urn:ex/zone-305-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-512-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-512-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-512-reheat-coil-water-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-512-reheat-coil-water-out"
+ "@id": "urn:ex/room-305-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/zone-305-temp"
}
]
},
{
- "@id": "urn:ex/vav-528-hot-water-in-connection",
+ "@id": "urn:ex/room-213-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-213"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-518-cooling-pid-output",
+ "@id": "urn:ex/vav-527-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-527-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-314-occupancy",
+ "@id": "urn:ex/vav-539-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-flow",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-521-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -22866,46 +22377,43 @@
]
},
{
- "@id": "urn:ex/vav-508-damper",
+ "@id": "urn:ex/vav-503-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-508-damper-in"
- },
+ "@id": "urn:ex/vav-503-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-508-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-508-damper-command"
+ "@id": "urn:ex/vav-503-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-508-damper-position"
+ "@id": "urn:ex/vav-503-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-540-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-523-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -22921,326 +22429,275 @@
]
},
{
- "@id": "urn:ex/zone-103-occupancy-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-103-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:ex/zone-103-occupancy"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-210",
+ "@id": "urn:ex/vav-533-damper",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-210-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "@id": "urn:ex/vav-533-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-533-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-210-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-210-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-210-occupancy"
- },
- {
- "@id": "urn:ex/zone-210-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-210-temp"
+ "@id": "urn:ex/vav-533-damper-command"
},
{
- "@id": "urn:ex/zone-210-window-switch-on-off"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-522-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-522-reheat-coil-valve"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
- {
- "@id": "urn:ex/vav-522-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-533-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-flow",
+ "@id": "urn:ex/vav-518-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-507-damper-position",
+ "@id": "urn:ex/room-203-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-203"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-position",
+ "@id": "urn:ex/vav-518-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-518-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-518-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-513",
+ "@id": "urn:ex/vav-504-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-air-in"
- },
- {
- "@id": "urn:ex/vav-513-air-out"
- },
- {
- "@id": "urn:ex/vav-513-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-513-hot-water-out"
+ "@id": "urn:ex/vav-504-air-in"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-513-damper"
- },
- {
- "@id": "urn:ex/vav-513-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve"
+ "@id": "urn:ex/vav-504-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-540-damper",
+ "@id": "urn:ex/vav-519-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-damper-in"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-540-damper-out"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-540-damper-command"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-540-damper-position"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-528-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-509-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-101-co2-concentration-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-504-air-in"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-504-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-water-in",
+ "@id": "http://data.ashrae.org/standard223#Role-Outside",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-539-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#EnumerationKind-Role"
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-301",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-539-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-colder-chilled-water-requests",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-water-in",
+ "@id": "urn:ex/vav-513-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-513-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-513-damper-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-530-hot-water-in"
+ "@id": "urn:ex/vav-513-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-513-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-110-temp-sensor",
+ "@id": "urn:ex/zone-201-temp",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-110-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-110-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-537-hot-water-in",
+ "@id": "urn:ex/vav-505-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-hot-water-in-connection"
+ "@id": "urn:ex/vav-505-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-313-hvac-domain",
+ "@id": "urn:ex/vav-516-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-313-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-313-out"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-537-air-out",
+ "@id": "urn:ex/office-ahu-sa-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-312"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -23250,101 +22707,116 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-537-discharge-air-flow"
+ "@id": "urn:ex/office-ahu-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-537-discharge-air-flow-setpoint"
+ "@id": "urn:ex/office-ahu-increased-air-pressure-requests"
},
{
- "@id": "urn:ex/vav-537-discharge-air-temp"
+ "@id": "urn:ex/office-ahu-sa-temp"
},
{
- "@id": "urn:ex/vav-537-discharge-air-temp-setpoint"
+ "@id": "urn:ex/office-ahu-sa-temp-setpoint"
+ },
+ {
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure"
+ },
+ {
+ "@id": "urn:ex/office-ahu-supply-duct-static-pressure-setpoint"
+ },
+ {
+ "@id": "urn:ex/office-ahu-warmer-supply-air-requests"
}
]
},
{
- "@id": "urn:ex/vav-530-air-out",
+ "@id": "urn:ex/vav-510-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-303-304-306"
+ "@id": "urn:ex/vav-510-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-hot-water-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-530-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-530-discharge-air-flow-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-539-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-530-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve",
+ "@id": "urn:ex/room-101-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-514-reheat-coil-valve-out"
+ "@id": "urn:ex/connection-to-room-101"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-command"
- },
+ "@id": "urn:ex/vav-505-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-505-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-525-heating-pid-output",
+ "@id": "urn:ex/vav-517-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-517-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-517-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-520-air-in",
+ "@id": "urn:ex/room-313-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -23354,9 +22826,9 @@
]
},
{
- "@id": "urn:ex/zone-301-cooling-setpoint",
+ "@id": "urn:ex/zone-302-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -23370,10 +22842,14 @@
]
},
{
- "@id": "urn:ex/vav-502-hot-water-out-connection",
+ "@id": "urn:ex/vav-516-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-516-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -23382,34 +22858,43 @@
]
},
{
- "@id": "urn:ex/vav-514-reheat-coil-valve-out",
+ "@id": "urn:ex/zone-108-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-514-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-110-hvac-domain",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-110-in"
+ },
+ {
+ "@id": "urn:ex/room-110-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-514-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-air-in",
+ "@id": "urn:ex/vav-521-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-duct-after-damper"
+ "@id": "urn:ex/vav-521-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -23419,89 +22904,66 @@
]
},
{
- "@id": "urn:ex/vav-539-discharge-air-temp",
+ "@id": "urn:ex/vav-529-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-529-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-discharge-air-flow",
+ "@id": "urn:ex/vav-539-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-518-hot-water-in-connection",
+ "@id": "urn:ex/vav-531-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve",
+ "@id": "urn:ex/room-306-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-valve-out"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-507-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-507-damper-in",
+ "@id": "urn:ex/vav-534-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -23517,74 +22979,82 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-507-air-in"
+ "@id": "urn:ex/vav-534-air-in"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-535-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve"
+ "@id": "urn:ex/connection-to-room-311"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-526-reheat-coil-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-535-heating-pid-output"
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-535-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-535-air-out"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-204-205",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-command"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-103-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-310-in",
+ "@id": "urn:ex/vav-519-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/vav-519-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-519-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-position",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -23598,108 +23068,93 @@
]
},
{
- "@id": "urn:ex/vav-528-damper-out",
+ "@id": "urn:ex/vav-512-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-118"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-528-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-528-cooling-pid-output"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-101",
- "@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-101-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-101-building-static-pressure"
- },
- {
- "@id": "urn:ex/zone-101-building-static-pressure-setpoint"
- },
- {
- "@id": "urn:ex/zone-101-co2-concentration"
- },
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-101-co2-concentration-setpoint"
+ "@id": "urn:ex/vav-512-discharge-air-flow"
},
{
- "@id": "urn:ex/zone-101-cooling-setpoint"
+ "@id": "urn:ex/vav-512-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/zone-101-heating-setpoint"
+ "@id": "urn:ex/vav-512-discharge-air-temp"
},
{
- "@id": "urn:ex/zone-101-occupancy"
- },
+ "@id": "urn:ex/vav-512-discharge-air-temp-setpoint"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-215-hvac-domain",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-101-occupancy-override"
+ "@id": "urn:ex/room-215-in"
},
{
- "@id": "urn:ex/zone-101-temp"
- },
+ "@id": "urn:ex/room-215-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/zone-101-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-519-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-113-heating-setpoint",
+ "@id": "urn:ex/vav-506-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-110-occupancy-override",
+ "@id": "urn:ex/zone-101-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -23710,131 +23165,160 @@
]
},
{
- "@id": "urn:ex/office-ahu-moisture-eliminator",
+ "@id": "urn:ex/office-ahu-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#AirFilter",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-in"
- },
+ "@id": "urn:ex/office-ahu-hot-water-in-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-command",
+ "@id": "urn:ex/office-ahu-air-filter",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#AirFilter",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/office-ahu-air-filter-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/office-ahu-air-filter-out"
}
]
},
{
- "@id": "urn:ex/room-112",
+ "@id": "urn:ex/room-304",
"@type": [
"http://data.ashrae.org/standard223#PhysicalSpace"
],
"http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/room-112-hvac-domain"
+ "@id": "urn:ex/room-304-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-536-damper-command",
+ "@id": "urn:ex/room-113-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-113-in"
+ },
+ {
+ "@id": "urn:ex/room-113-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-out",
+ "@id": "urn:ex/office-ahu-sa-fan",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
+ "@id": "urn:ex/office-ahu-sa-fan-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-fan-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/office-ahu-sa-fan-power"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-fan-speed-cmd"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-fan-speed-status"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-fan-start-cmd"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-fan-start-status"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
}
]
},
{
- "@id": "urn:ex/zone-204-205-cooling-setpoint",
+ "@id": "urn:ex/vav-536-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-536-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-520-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/vav-513-air-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-513-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-511-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-531-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -23848,174 +23332,158 @@
]
},
{
- "@id": "urn:ex/vav-521-hot-water-out",
+ "@id": "urn:ex/zone-307-308-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-521-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-527-hot-water-out",
+ "@id": "urn:ex/vav-532-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-527-hot-water-out-connection"
+ "@id": "urn:ex/vav-532-air-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-532-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve",
+ "@id": "urn:ex/zone-208-209-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-505-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-505-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/room-208-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-505-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-208-209-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-water-in",
+ "@id": "urn:ex/vav-533-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-533-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan-speed-status",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-533-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-504-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-529-air-out"
+ "@id": "urn:ex/vav-504-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-529-discharge-air-temp"
+ "@id": "urn:ex/vav-504-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-203",
+ "@id": "urn:ex/zone-309-310-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-203-hvac-domain"
+ "@id": "urn:ex/room-309-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-510-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-309-310-occupancy"
}
]
},
{
- "@id": "urn:ex/room-214-hvac-domain",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-214-in"
- },
- {
- "@id": "urn:ex/room-214-out"
+ "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper",
+ "@id": "urn:ex/vav-514-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ra-damper-in"
- },
- {
- "@id": "urn:ex/office-ahu-ra-damper-out"
+ "@id": "urn:ex/vav-514-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-ra-damper-command"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/office-ahu-ra-damper-position"
+ "@id": "urn:ex/vav-514-hot-water-in"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-313",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Return"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-115-occupancy",
+ "@id": "urn:ex/zone-212-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -24026,86 +23494,68 @@
]
},
{
- "@id": "urn:ex/zone-104-cooling-setpoint",
+ "@id": "urn:ex/vav-526-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-526-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-526-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-air-out",
+ "@id": "urn:ex/vav-526",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-203"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-526-air-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:ex/vav-526-air-out"
+ },
{
- "@id": "urn:ex/vav-517-heating-pid-output"
+ "@id": "urn:ex/vav-526-hot-water-in"
},
{
- "@id": "urn:ex/vav-517-more-heat-requests"
+ "@id": "urn:ex/vav-526-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-517-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-540-reheat-coil-valve-position",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-526-damper"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-526-reheat-coil"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-526-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-position",
+ "@id": "urn:ex/zone-314-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-oa-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -24119,85 +23569,61 @@
]
},
{
- "@id": "urn:ex/vav-516-damper-position",
+ "@id": "urn:ex/vav-528-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve",
+ "@id": "urn:ex/vav-537-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-537-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-524-reheat-coil-valve-command"
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil-valve-position"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-508-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-530-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-104",
+ "@id": "urn:ex/zone-309-310",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-104-hvac-domain"
+ "@id": "urn:ex/room-309-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-310-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -24207,92 +23633,81 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-104-cooling-setpoint"
+ "@id": "urn:ex/zone-309-310-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-104-heating-setpoint"
+ "@id": "urn:ex/zone-309-310-heating-setpoint"
},
{
- "@id": "urn:ex/zone-104-occupancy"
+ "@id": "urn:ex/zone-309-310-occupancy"
},
{
- "@id": "urn:ex/zone-104-occupancy-override"
+ "@id": "urn:ex/zone-309-310-occupancy-override"
},
{
- "@id": "urn:ex/zone-104-temp"
+ "@id": "urn:ex/zone-309-310-temp"
},
{
- "@id": "urn:ex/zone-104-window-switch-on-off"
+ "@id": "urn:ex/zone-309-310-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-512",
+ "@id": "urn:ex/vav-540-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-512-air-in"
- },
- {
- "@id": "urn:ex/vav-512-air-out"
- },
- {
- "@id": "urn:ex/vav-512-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-512-hot-water-out"
+ "@id": "urn:ex/vav-540-damper"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-512-damper"
- },
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-512-reheat-coil"
- },
+ "@id": "urn:ex/vav-540-damper-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-520-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-512-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-colder-supply-air-requests",
+ "@id": "urn:ex/room-118-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/vav-526-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve",
+ "@id": "urn:ex/vav-502-reheat-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-502-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-502-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24302,21 +23717,21 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-502-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-502-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-525-damper-in",
+ "@id": "urn:ex/vav-508-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-109"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24324,62 +23739,80 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-508-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-508-more-heat-requests"
+ }
+ ],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-525-air-in"
+ "@id": "urn:ex/vav-508-air-out"
}
]
},
{
- "@id": "urn:ex/zone-213-heating-setpoint",
+ "@id": "urn:ex/vav-509-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-509-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-509-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-501-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-oa-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-oa-damper-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/office-ahu-oa-damper-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-damper-position"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Economizer"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Outside"
}
]
},
{
- "@id": "urn:ex/vav-528-damper-command",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -24395,115 +23828,155 @@
]
},
{
- "@id": "urn:ex/vav-521",
+ "@id": "urn:ex/room-115-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-air-in"
+ "@id": "urn:ex/room-115-in"
},
{
- "@id": "urn:ex/vav-521-air-out"
- },
+ "@id": "urn:ex/room-115-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-521-hot-water-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-discharge-air-temp-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-damper"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-flow",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-521-reheat-coil"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve",
+ "@id": "urn:ex/room-304-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-in"
+ "@id": "urn:ex/room-304-in"
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-out"
+ "@id": "urn:ex/room-304-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-207",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-command"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-position"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil",
+ "@id": "urn:ex/vav-524-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-518-reheat-coil-air-out"
+ "@id": "urn:ex/vav-524-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-518-reheat-coil-water-in"
- },
+ "@id": "urn:ex/vav-524-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-518-reheat-coil-water-out"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-524-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-actuator",
+ "@id": "urn:ex/zone-204-205-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-air-out",
+ "@id": "urn:ex/vav-515-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-309-310"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24513,177 +23986,281 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-discharge-air-flow"
+ "@id": "urn:ex/vav-515-heating-pid-output"
},
{
- "@id": "urn:ex/vav-532-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-515-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-515-air-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-505",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-505-air-in"
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp"
+ "@id": "urn:ex/vav-505-air-out"
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-505-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-505-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-505-damper"
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-505-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-out",
+ "@id": "urn:ex/connection-to-room-113",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-508-hot-water-out-connection"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-air-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-508-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-532-more-heat-requests",
+ "@id": "urn:ex/office-ahu-ra-fan-start-cmd",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-516-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-201"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-516-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-516-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-526-hot-water-out"
+ "@id": "urn:ex/vav-516-air-out"
}
]
},
{
- "@id": "urn:ex/office-ahu-chilled-water-in-connection",
+ "@id": "urn:ex/vav-517",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-517-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-517-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-517-damper"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-211-occupancy-override",
+ "@id": "urn:ex/vav-513-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-101-building-static-pressure",
+ "@id": "urn:ex/zone-301-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:ex/room-301-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:ex/zone-301-temp"
}
]
},
{
- "@id": "urn:ex/vav-510-hot-water-in",
+ "@id": "urn:ex/office-ahu",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/office-ahu-chilled-water-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-530-reheat-coil",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/office-ahu-chilled-water-out"
+ },
{
- "@id": "urn:ex/vav-530-reheat-coil-air-in"
+ "@id": "urn:ex/office-ahu-ea-out"
},
{
- "@id": "urn:ex/vav-530-reheat-coil-air-out"
+ "@id": "urn:ex/office-ahu-hot-water-in"
},
{
- "@id": "urn:ex/vav-530-reheat-coil-water-in"
+ "@id": "urn:ex/office-ahu-hot-water-out"
},
{
- "@id": "urn:ex/vav-530-reheat-coil-water-out"
+ "@id": "urn:ex/office-ahu-oa-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-out"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/office-ahu-air-filter"
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil"
+ },
+ {
+ "@id": "urn:ex/office-ahu-clg-coil-valve"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-valve"
+ },
+ {
+ "@id": "urn:ex/office-ahu-moisture-eliminator"
+ },
+ {
+ "@id": "urn:ex/office-ahu-oa-damper"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-damper"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-fan"
+ },
+ {
+ "@id": "urn:ex/office-ahu-sa-fan"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-513-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-103"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-513-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-513-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-513-air-out"
}
]
},
{
- "@id": "urn:ex/vav-532-air-in",
+ "@id": "urn:ex/room-210-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24693,24 +24270,18 @@
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumerationKind"
- ]
- },
- {
- "@id": "urn:ex/vav-519-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-531-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-air-in"
+ "@id": "urn:ex/vav-531-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
@@ -24731,260 +24302,244 @@
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-528-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-514-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-514-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-514-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-514-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-514-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-hot-water-in",
+ "@id": "urn:ex/vav-512-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-204-205-temp-sensor",
+ "@id": "urn:ex/vav-519-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-204-hvac-domain"
+ "@id": "urn:ex/vav-519-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/zone-204-205-temp"
+ "@id": "urn:ex/vav-519-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-508-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-523-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-115-window-switch-on-off",
+ "@id": "urn:ex/room-312",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-312-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-115",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "urn:ex/vav-518-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-115-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-115-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-115-occupancy"
- },
- {
- "@id": "urn:ex/zone-115-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-115-temp"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-115-window-switch-on-off"
+ "@id": "urn:ex/vav-518-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-535-damper-position",
+ "@id": "urn:ex/zone-307-308-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-air-in"
+ "@id": "urn:ex/vav-507-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-502-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-507-hot-water-out"
}
]
},
{
- "@id": "urn:ex/room-101-out",
+ "@id": "urn:ex/zone-213-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-213-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-213-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-air-out",
+ "@id": "urn:ex/zone-213-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-112-114"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-511-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-511-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-511-air-out"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-water-out",
+ "@id": "urn:ex/vav-539-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-214"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-207",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-207-hvac-domain"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-540-discharge-air-flow",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "@id": "urn:ex/vav-539-discharge-air-flow"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-539-discharge-air-flow-setpoint"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-539-discharge-air-temp"
+ },
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-539-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-210-heating-setpoint",
+ "@id": "urn:ex/zone-108-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -25000,45 +24555,41 @@
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-503-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-530-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-503-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-530-hot-water-out"
+ "@id": "urn:ex/vav-503-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-532-colder-supply-air-requests",
+ "@id": "urn:ex/vav-502-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-516-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -25048,13 +24599,13 @@
]
},
{
- "@id": "urn:ex/vav-530-damper-out",
+ "@id": "urn:ex/vav-505-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-530-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-108"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -25064,37 +24615,47 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-530-colder-supply-air-requests"
+ "@id": "urn:ex/vav-505-heating-pid-output"
},
{
- "@id": "urn:ex/vav-530-cooling-pid-output"
+ "@id": "urn:ex/vav-505-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-505-air-out"
}
]
},
{
- "@id": "urn:ex/room-307-in",
+ "@id": "urn:ex/vav-538-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-307-308"
+ "@id": "urn:ex/vav-538-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-538-hot-water-in"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-in",
+ "@id": "urn:ex/vav-515-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -25104,106 +24665,110 @@
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-water-out",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-536-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-536-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-509-damper-position",
+ "@id": "urn:ex/zone-106-107-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-511-cooling-pid-output",
+ "@id": "urn:ex/vav-509-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-501-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-hot-water-in",
+ "@id": "urn:ex/vav-512-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-hot-water-in-connection"
+ "@id": "urn:ex/vav-512-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-512-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/room-303-hvac-domain",
+ "@id": "urn:ex/zone-210-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-303-in"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-303-out"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-213-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-temp",
+ "@id": "urn:ex/vav-522-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25214,186 +24779,191 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-112-114",
+ "@id": "urn:ex/vav-501",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-112-hvac-domain"
+ "@id": "urn:ex/vav-501-air-in"
},
{
- "@id": "urn:ex/room-114-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-112-114-cooling-setpoint"
+ "@id": "urn:ex/vav-501-air-out"
},
{
- "@id": "urn:ex/zone-112-114-heating-setpoint"
+ "@id": "urn:ex/vav-501-hot-water-in"
},
{
- "@id": "urn:ex/zone-112-114-occupancy"
- },
+ "@id": "urn:ex/vav-501-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/zone-112-114-occupancy-override"
+ "@id": "urn:ex/vav-501-damper"
},
{
- "@id": "urn:ex/zone-112-114-temp"
+ "@id": "urn:ex/vav-501-reheat-coil"
},
{
- "@id": "urn:ex/zone-112-114-window-switch-on-off"
+ "@id": "urn:ex/vav-501-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-air-in",
+ "@id": "urn:ex/vav-515-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-duct-after-damper"
+ "@id": "urn:ex/vav-515-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-305-occupancy-sensor",
+ "@id": "urn:ex/office-ahu-sa-flow",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-305-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Supply"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/zone-305-occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
- ]
- },
- {
- "@id": "urn:ex/zone-210-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-107-hvac-domain",
+ "@id": "urn:ex/vav-535-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-107-in"
- },
- {
- "@id": "urn:ex/room-107-out"
+ "@id": "urn:ex/vav-535-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-flow",
+ "@id": "urn:ex/zone-305-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-502-heating-pid-output",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/connection-to-room-212",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-104-in",
+ "@id": "urn:ex/vav-525-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-104"
+ "@id": "urn:ex/vav-525-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-chilled-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-525-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-105-in",
+ "@id": "urn:ex/room-112-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-105"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -25403,124 +24973,126 @@
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve",
+ "@id": "urn:ex/zone-101-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-in"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-out"
+ "@id": "urn:ex/connection-to-room-210"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-524-heating-pid-output"
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-524-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-524-air-out"
}
]
},
{
- "@id": "urn:ex/vav-511-hot-water-in",
+ "@id": "urn:ex/vav-518-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-hot-water-in-connection"
+ "@id": "urn:ex/vav-518-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-305-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-505-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-505-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-actuator",
+ "@id": "urn:ex/vav-504-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-529-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-529-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-116-117-cooling-setpoint",
+ "@id": "urn:ex/vav-525-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-111-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-110-hvac-domain",
+ "@id": "urn:ex/room-105-hvac-domain",
"@type": [
"http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-110-in"
+ "@id": "urn:ex/room-105-in"
},
{
- "@id": "urn:ex/room-110-out"
+ "@id": "urn:ex/room-105-out"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -25530,296 +25102,321 @@
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-temp-setpoint",
+ "@id": "urn:ex/room-214-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-210-out",
+ "@id": "urn:ex/zone-113-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-113-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-113-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve"
+ "@id": "urn:ex/vav-519-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-519-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-203-occupancy",
+ "@id": "urn:ex/connection-to-room-106-107",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-203-window-switch-on-off",
+ "@id": "urn:ex/vav-510-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/vav-510-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-510-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-510-damper-position"
}
]
},
{
- "@id": "urn:ex/room-202-in",
+ "@id": "urn:ex/vav-517-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-202"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-537-more-heat-requests",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-307-308-temp-sensor",
+ "@id": "urn:ex/vav-503-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-307-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-307-308-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-air-in",
+ "@id": "urn:ex/vav-521-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-duct-after-damper"
+ "@id": "urn:ex/vav-521-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-521-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-528-air-out",
+ "@id": "urn:ex/vav-510-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/connection-to-room-302"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-528-discharge-air-flow"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-528-discharge-air-flow-setpoint"
- },
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-508-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-528-discharge-air-temp"
- },
+ "@id": "urn:ex/vav-508-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-528-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-508-damper-command"
}
]
},
{
- "@id": "urn:ex/room-307-hvac-domain",
+ "@id": "urn:ex/vav-507-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-307-in"
- },
- {
- "@id": "urn:ex/room-307-out"
+ "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-503-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-112-114-occupancy-sensor",
+ "@id": "urn:ex/vav-538-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-112-hvac-domain"
+ "@id": "urn:ex/vav-538-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-112-114-occupancy"
+ "@id": "urn:ex/vav-538-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-524-duct-after-damper",
+ "@id": "urn:ex/vav-516-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-516-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-516-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-103-hvac-domain",
+ "@id": "urn:ex/zone-211-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-103-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-103-out"
+ "@id": "urn:ex/room-211-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/zone-211-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-temp-setpoint",
+ "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-502-damper-command",
+ "@id": "urn:ex/vav-517-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-moisture-eliminator-out",
+ "@id": "urn:ex/vav-516-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-temp",
+ "@id": "urn:ex/vav-508-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25830,62 +25427,84 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-301-temp",
+ "@id": "urn:ex/vav-506-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-506-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-506-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-506-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-506-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil",
+ "@id": "urn:ex/zone-211",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-523-reheat-coil-air-in"
+ "@id": "urn:ex/room-211-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-211-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-air-out"
+ "@id": "urn:ex/zone-211-heating-setpoint"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-in"
+ "@id": "urn:ex/zone-211-occupancy"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:ex/zone-211-occupancy-override"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/zone-211-temp"
+ },
+ {
+ "@id": "urn:ex/zone-211-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/connection-to-room-118",
+ "@id": "urn:ex/vav-528-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -25894,161 +25513,152 @@
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-air-out",
+ "@id": "urn:ex/room-303-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-312"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-311",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-537-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-537-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-in",
+ "@id": "urn:ex/vav-506-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
+ "@id": "urn:ex/vav-506-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-506-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-520-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-528-air-out"
+ "@id": "urn:ex/vav-520-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-528-discharge-air-temp"
+ "@id": "urn:ex/vav-520-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-509-air-out",
+ "@id": "urn:ex/vav-513-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-113"
+ "@id": "urn:ex/vav-513-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-509-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-509-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-509-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-509-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-301-occupancy-override",
+ "@id": "urn:ex/vav-513-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-522-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-511-damper-out",
+ "@id": "urn:ex/zone-108",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-511-duct-after-damper"
+ "@id": "urn:ex/room-108-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-colder-supply-air-requests"
+ "@id": "urn:ex/zone-108-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-511-cooling-pid-output"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-518-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/zone-108-heating-setpoint"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-108-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-108-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-108-temp"
+ },
+ {
+ "@id": "urn:ex/zone-108-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-flow",
+ "@id": "urn:ex/vav-532-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -26069,54 +25679,61 @@
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-water-out",
+ "@id": "urn:ex/vav-532-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-532-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-532-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-temp",
+ "@id": "urn:ex/vav-538-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-538-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-538-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve",
+ "@id": "urn:ex/vav-530-reheat-coil-valve",
"@type": [
"http://data.ashrae.org/standard223#Valve",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26126,500 +25743,445 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-532-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/room-117",
+ "@id": "urn:ex/room-111",
"@type": [
"http://data.ashrae.org/standard223#PhysicalSpace"
],
"http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/room-117-hvac-domain"
+ "@id": "urn:ex/room-111-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-531-damper-actuator",
+ "@id": "urn:ex/zone-309-310-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-531-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-531-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-528-duct-after-damper",
+ "@id": "urn:ex/zone-305-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-506-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-506-hot-water-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-506-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-523",
+ "@id": "urn:ex/vav-519-damper",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-air-in"
- },
- {
- "@id": "urn:ex/vav-523-air-out"
- },
- {
- "@id": "urn:ex/vav-523-hot-water-in"
+ "@id": "urn:ex/vav-519-damper-in"
},
{
- "@id": "urn:ex/vav-523-hot-water-out"
+ "@id": "urn:ex/vav-519-damper-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-523-damper"
- },
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-523-reheat-coil"
+ "@id": "urn:ex/vav-519-damper-command"
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve"
+ "@id": "urn:ex/vav-519-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-305-temp",
+ "@id": "urn:ex/vav-506-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/",
+ "@id": "urn:ex/vav-507-reheat-coil-valve-position",
"@type": [
- "http://www.w3.org/2002/07/owl#Ontology"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
]
},
{
- "@id": "urn:ex/room-304-hvac-domain",
+ "@id": "urn:ex/zone-303-304-306-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-304-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-304-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-211",
+ "@id": "urn:ex/vav-523-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-211-hvac-domain"
+ "@id": "urn:ex/connection-to-room-206"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-211-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-211-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-211-occupancy"
+ "@id": "urn:ex/vav-523-discharge-air-flow"
},
{
- "@id": "urn:ex/zone-211-occupancy-override"
+ "@id": "urn:ex/vav-523-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/zone-211-temp"
+ "@id": "urn:ex/vav-523-discharge-air-temp"
},
{
- "@id": "urn:ex/zone-211-window-switch-on-off"
+ "@id": "urn:ex/vav-523-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-actuator",
+ "@id": "urn:ex/room-104",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-537-damper"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-537-damper-command"
+ "@id": "urn:ex/room-104-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-206-occupancy-override",
+ "@id": "urn:ex/zone-212-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-516-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-540-reheat-coil-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-525-hot-water-in",
+ "@id": "urn:ex/zone-111-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-air-out",
+ "@id": "urn:ex/zone-206-co2-concentration-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-211"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-525-heating-pid-output"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-more-heat-requests"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-525-air-out"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-command",
+ "@id": "urn:ex/room-118-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-118-in"
+ },
+ {
+ "@id": "urn:ex/room-118-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-509-heating-pid-output",
+ "@id": "urn:ex/vav-532-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-503-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve"
+ "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-529-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-air-in",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-duct-after-damper"
+ "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/office-ahu-sa-fan-start-status",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/room-106-in",
+ "@id": "urn:ex/vav-517-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-106-107"
+ "@id": "urn:ex/vav-517-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-517-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-517-cooling-pid-output"
+ }
]
},
{
- "@id": "urn:ex/vav-525",
+ "@id": "urn:ex/zone-215-temp",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-525-air-in"
- },
- {
- "@id": "urn:ex/vav-525-air-out"
- },
- {
- "@id": "urn:ex/vav-525-hot-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-525-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-525-damper"
- },
- {
- "@id": "urn:ex/vav-525-reheat-coil"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-525-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-111",
+ "@id": "urn:ex/vav-539-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-111-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-111-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-111-occupancy"
- },
- {
- "@id": "urn:ex/zone-111-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-111-temp"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/zone-111-window-switch-on-off"
+ "@id": "urn:ex/vav-539-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-water-out",
+ "@id": "urn:ex/room-203-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-damper-in",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-oa-flow"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-oa-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-hot-water-out",
+ "@id": "urn:ex/vav-540-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-hot-water-out-connection"
+ "@id": "urn:ex/vav-540-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-514-air-in",
+ "@id": "urn:ex/vav-506-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-506-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -26635,57 +26197,61 @@
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-103-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-103-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-103-temp"
}
]
},
{
- "@id": "urn:ex/vav-529-cooling-pid-output",
+ "@id": "urn:ex/vav-508",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-508-air-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-508-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-508-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-hot-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-508-damper"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-air-out",
+ "@id": "urn:ex/vav-530-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-201"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26695,105 +26261,84 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-516-heating-pid-output"
+ "@id": "urn:ex/vav-530-heating-pid-output"
},
{
- "@id": "urn:ex/vav-516-more-heat-requests"
+ "@id": "urn:ex/vav-530-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-516-air-out"
+ "@id": "urn:ex/vav-530-air-out"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-water-out",
+ "@id": "urn:ex/vav-509-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-509-reheat-coil-valve"
}
- ]
- },
- {
- "@id": "urn:ex/vav-505-colder-supply-air-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-509-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-530-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-530-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-530-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil",
+ "@id": "urn:ex/vav-502-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-507-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-507-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-507-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-position",
+ "@id": "urn:ex/zone-211-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-211-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-211-temp"
}
]
},
{
- "@id": "urn:ex/vav-504-damper-in",
+ "@id": "urn:ex/vav-511-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -26806,98 +26351,74 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-504-air-in"
- }
]
},
{
- "@id": "urn:ex/zone-305-occupancy",
+ "@id": "urn:ex/office-ahu-ra-fan-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-duct-after-moisture-eliminator",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-ra-in"
+ }
]
},
{
- "@id": "urn:ex/zone-112-114-temp-sensor",
+ "@id": "urn:ex/zone-110-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-112-hvac-domain"
+ "@id": "urn:ex/room-110-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-112-114-temp"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-108-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/zone-110-occupancy"
}
]
},
{
- "@id": "urn:ex/room-108",
+ "@id": "urn:ex/vav-520-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-108-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-537-reheat-coil-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-537-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-out",
+ "@id": "urn:ex/vav-537-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-hot-water-out-connection"
+ "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -26907,7 +26428,7 @@
]
},
{
- "@id": "urn:ex/vav-503-damper-in",
+ "@id": "urn:ex/vav-530-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -26920,31 +26441,32 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-503-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-210-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-101-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-532-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -26956,93 +26478,82 @@
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-501-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-501-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-501-damper-command"
}
]
},
{
- "@id": "urn:ex/zone-115-temp-sensor",
+ "@id": "urn:ex/vav-530-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-115-hvac-domain"
+ "@id": "urn:ex/vav-530-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/zone-115-temp"
+ "@id": "urn:ex/vav-530-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-502",
+ "@id": "urn:ex/vav-529-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-air-in"
+ "@id": "urn:ex/vav-529-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-502-air-out"
+ "@id": "urn:ex/vav-529-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-502-hot-water-in"
+ "@id": "urn:ex/vav-529-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-502-hot-water-out"
+ "@id": "urn:ex/vav-529-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-502-damper"
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-502-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-command",
+ "@id": "urn:ex/zone-112-114-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-air-out",
+ "@id": "urn:ex/vav-524-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-311"
+ "@id": "urn:ex/vav-524-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27052,93 +26563,92 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-535-heating-pid-output"
+ "@id": "urn:ex/vav-524-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-535-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-535-air-out"
+ "@id": "urn:ex/vav-524-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-206-window-switch-on-off",
+ "@id": "urn:ex/vav-520-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/vav-531-air-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-307-308"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-208-209-cooling-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-531-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-531-discharge-air-flow-setpoint"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-discharge-air-temp"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-531-discharge-air-temp-setpoint"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-537-air-in",
+ "@id": "urn:ex/room-208-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/room-208-in"
+ },
+ {
+ "@id": "urn:ex/room-208-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/room-114-in",
+ "@id": "urn:ex/vav-540-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-112-114"
+ "@id": "urn:ex/vav-540-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-540-hot-water-out"
}
]
},
{
- "@id": "urn:ex/connection-to-room-203",
+ "@id": "urn:ex/connection-to-room-208-209",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -27150,14 +26660,10 @@
]
},
{
- "@id": "urn:ex/vav-527-hot-water-in",
+ "@id": "urn:ex/vav-513-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-527-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -27166,83 +26672,122 @@
]
},
{
- "@id": "urn:ex/vav-505-damper-out",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-505-duct-after-damper"
+ "@id": "urn:ex/vav-533-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-533-reheat-coil-valve-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-115-occupancy-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-505-colder-supply-air-requests"
- },
+ "@id": "urn:ex/room-115-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-505-cooling-pid-output"
+ "@id": "urn:ex/zone-115-occupancy"
}
]
},
{
- "@id": "urn:ex/room-114",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-114-hvac-domain"
+ "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/connection-to-room-208-209",
+ "@id": "urn:ex/vav-522-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil",
+ "@id": "urn:ex/vav-516-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-527-reheat-coil-air-in"
- },
+ "@id": "urn:ex/vav-516-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-527-reheat-coil-air-out"
- },
+ "@id": "urn:ex/vav-516-discharge-air-flow"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-536-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-reheat-coil-water-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-527-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-214-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/room-214-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/zone-214-temp"
}
]
},
{
- "@id": "urn:ex/vav-523-hot-water-out-connection",
+ "@id": "urn:ex/vav-514-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-514-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -27251,39 +26796,60 @@
]
},
{
- "@id": "urn:ex/vav-514-damper-command",
+ "@id": "urn:ex/vav-509-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil-air-in",
+ "@id": "urn:ex/vav-527-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-duct-after-damper"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-527-air-in"
+ }
]
},
{
- "@id": "urn:ex/vav-526-duct-after-damper",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-506-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -27295,13 +26861,29 @@
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-water-in",
+ "@id": "urn:ex/vav-513-reheat-coil-water-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-hot-water-in-connection"
+ "@id": "urn:ex/vav-516-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27311,12 +26893,23 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-536-hot-water-in"
+ "@id": "urn:ex/vav-516-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-533-hot-water-out-connection",
+ "@id": "urn:ex/room-204",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
+ ],
+ "http://data.ashrae.org/standard223#encloses": [
+ {
+ "@id": "urn:ex/room-204-hvac-domain"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -27328,174 +26921,212 @@
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-511-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-112-114"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-511-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-511-more-heat-requests"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-528-hot-water-out"
+ "@id": "urn:ex/vav-511-air-out"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-509",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-509-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-509-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-509-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-509-damper"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-509-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-537-cooling-pid-output",
+ "@id": "urn:ex/zone-314-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-512-air-in",
+ "@id": "urn:ex/vav-515-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-531-damper-command",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-515-discharge-air-flow"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-515-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-515-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-515-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-530-hot-water-out",
+ "@id": "urn:ex/room-309",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-530-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-309-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-518-damper-command",
+ "@id": "urn:ex/room-206-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-206"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-air-in",
+ "@id": "urn:ex/vav-520-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-duct-after-damper"
+ "@id": "urn:ex/vav-520-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-105-occupancy",
+ "@id": "urn:ex/vav-509-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-510-damper",
+ "@id": "urn:ex/vav-534-damper",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-damper-in"
+ "@id": "urn:ex/vav-534-damper-in"
},
{
- "@id": "urn:ex/vav-510-damper-out"
+ "@id": "urn:ex/vav-534-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-510-damper-command"
+ "@id": "urn:ex/vav-534-damper-command"
},
{
- "@id": "urn:ex/vav-510-damper-position"
+ "@id": "urn:ex/vav-534-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-534-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-534-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-534-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-534-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-526-colder-supply-air-requests",
+ "@id": "urn:ex/vav-506-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -27506,50 +27137,64 @@
]
},
{
- "@id": "urn:ex/zone-214-temp-sensor",
+ "@id": "urn:ex/zone-203-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-214-hvac-domain"
+ "@id": "urn:ex/room-203-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-214-temp"
+ "@id": "urn:ex/zone-203-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-flow",
+ "@id": "urn:ex/room-201-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/room-201-in"
+ },
+ {
+ "@id": "urn:ex/room-201-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-101-building-static-pressure",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/vav-512-damper-in",
+ "@id": "urn:ex/vav-511-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-112-114"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27557,113 +27202,144 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-512-air-in"
+ "@id": "urn:ex/vav-511-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-511-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-511-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-511-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-505-damper",
+ "@id": "urn:ex/room-306-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-505-damper-in"
- },
- {
- "@id": "urn:ex/vav-505-damper-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-505-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-valve-out",
+ "@id": "urn:ex/zone-202-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-chilled-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-501-air-in"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-chilled-water-out"
+ "@id": "urn:ex/vav-501-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-actuator",
+ "@id": "urn:ex/zone-112-114-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-111-in",
+ "@id": "urn:ex/vav-540-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-111"
+ "@id": "urn:ex/vav-540-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-540-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-301-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-534-reheat-coil-valve-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-524-air-in",
+ "@id": "urn:ex/vav-503-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -27672,114 +27348,175 @@
]
},
{
- "@id": "urn:ex/office-ahu-chilled-water-out",
+ "@id": "urn:ex/vav-503-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-chilled-water-out-connection"
+ "@id": "urn:ex/vav-503-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-503-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-occupancy-sensor",
+ "@id": "urn:ex/vav-526-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-303-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-303-304-306-occupancy"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-201-occupancy-override",
+ "@id": "urn:ex/vav-537-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-539-air-in",
+ "@id": "urn:ex/vav-505-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-505-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-505-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-312-heating-setpoint",
+ "@id": "urn:ex/vav-515-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-515-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-515-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-515-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-515-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-307-308-heating-setpoint",
+ "@id": "urn:ex/room-302-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/room-302-in"
+ },
+ {
+ "@id": "urn:ex/room-302-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/office-ahu-ea-damper-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-501-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-air-out"
+ "@id": "urn:ex/connection-to-room-102"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-501-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-flow-setpoint"
+ },
{
"@id": "urn:ex/vav-501-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-507-colder-supply-air-requests",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-531-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -27790,43 +27527,61 @@
]
},
{
- "@id": "urn:ex/connection-to-room-314",
+ "@id": "urn:ex/vav-532-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-532-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-525-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-503-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-503-hot-water-out"
+ "@id": "urn:ex/vav-525-air-in"
}
]
},
{
- "@id": "urn:ex/vav-507-hot-water-in-connection",
+ "@id": "urn:ex/vav-524-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-524-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -27835,47 +27590,72 @@
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-water-out",
+ "@id": "urn:ex/vav-504-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-504-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-504-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-temp",
+ "@id": "urn:ex/zone-303-304-306-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-reheat-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -27884,51 +27664,70 @@
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-water-in",
+ "@id": "urn:ex/vav-519-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-510-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-510-hot-water-in"
+ "@id": "urn:ex/vav-519-air-in"
}
]
},
{
- "@id": "urn:ex/room-103-out",
+ "@id": "urn:ex/vav-514-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-524-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:ex/vav-524-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-524-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-215",
+ "@id": "urn:ex/zone-116-117",
"@type": [
"http://data.ashrae.org/standard223#Zone",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-215-hvac-domain"
+ "@id": "urn:ex/room-116-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-117-hvac-domain"
}
],
"http://data.ashrae.org/standard223#hasDomain": [
@@ -27938,33 +27737,33 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-215-cooling-setpoint"
+ "@id": "urn:ex/zone-116-117-cooling-setpoint"
},
{
- "@id": "urn:ex/zone-215-heating-setpoint"
+ "@id": "urn:ex/zone-116-117-heating-setpoint"
},
{
- "@id": "urn:ex/zone-215-occupancy"
+ "@id": "urn:ex/zone-116-117-occupancy"
},
{
- "@id": "urn:ex/zone-215-occupancy-override"
+ "@id": "urn:ex/zone-116-117-occupancy-override"
},
{
- "@id": "urn:ex/zone-215-temp"
+ "@id": "urn:ex/zone-116-117-temp"
},
{
- "@id": "urn:ex/zone-215-window-switch-on-off"
+ "@id": "urn:ex/zone-116-117-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-529-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27974,70 +27773,72 @@
]
},
{
- "@id": "urn:ex/zone-314-temp",
+ "@id": "urn:ex/vav-506-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-temp-sensor",
+ "@id": "urn:ex/office-ahu-htg-coil",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-air-out"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:ex/office-ahu-htg-coil-air-in"
+ },
{
- "@id": "urn:ex/vav-516-discharge-air-temp"
+ "@id": "urn:ex/office-ahu-htg-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-531-cooling-pid-output",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-519-hot-water-out-connection",
+ "@id": "urn:ex/vav-507-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-507-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28046,179 +27847,158 @@
]
},
{
- "@id": "urn:ex/room-310-hvac-domain",
+ "@id": "urn:ex/vav-514-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-310-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-310-out"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/room-106-hvac-domain",
+ "@id": "urn:ex/zone-206-temp",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-106-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-106-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-527",
+ "@id": "urn:ex/vav-514-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-527-air-in"
- },
- {
- "@id": "urn:ex/vav-527-air-out"
- },
- {
- "@id": "urn:ex/vav-527-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-527-hot-water-out"
+ "@id": "urn:ex/vav-514-damper"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-527-damper"
- },
- {
- "@id": "urn:ex/vav-527-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-527-reheat-coil-valve"
+ "@id": "urn:ex/vav-514-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-water-out",
+ "@id": "urn:ex/vav-537-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-537-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-537-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/zone-105-cooling-setpoint",
+ "@id": "urn:ex/vav-533-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-533-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-533-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-532-air-in"
+ "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-532-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-531-damper-position",
+ "@id": "urn:ex/room-105",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/room-105-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-101-cooling-setpoint",
+ "@id": "urn:ex/vav-540-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-540-reheat-coil-valve-in"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-507-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-540-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-540-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-air-in",
+ "@id": "urn:ex/room-301-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-519-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-301"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -28228,198 +28008,213 @@
]
},
{
- "@id": "urn:ex/zone-214-occupancy",
+ "@id": "urn:ex/zone-206",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/room-206-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-506-discharge-air-flow-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ]
- },
- {
- "@id": "urn:ex/room-101-hvac-domain",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/zone-206-co2-concentration"
+ },
{
- "@id": "urn:ex/room-101-in"
+ "@id": "urn:ex/zone-206-co2-concentration-setpoint"
},
{
- "@id": "urn:ex/room-101-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "@id": "urn:ex/zone-206-cooling-setpoint"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/zone-206-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-206-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-206-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-206-temp"
+ },
+ {
+ "@id": "urn:ex/zone-206-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-523-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-517-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-509",
+ "@id": "urn:ex/vav-535",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-air-in"
+ "@id": "urn:ex/vav-535-air-in"
},
{
- "@id": "urn:ex/vav-509-air-out"
+ "@id": "urn:ex/vav-535-air-out"
},
{
- "@id": "urn:ex/vav-509-hot-water-in"
+ "@id": "urn:ex/vav-535-hot-water-in"
},
{
- "@id": "urn:ex/vav-509-hot-water-out"
+ "@id": "urn:ex/vav-535-hot-water-out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-509-damper"
+ "@id": "urn:ex/vav-535-damper"
},
{
- "@id": "urn:ex/vav-509-reheat-coil"
+ "@id": "urn:ex/vav-535-reheat-coil"
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve"
+ "@id": "urn:ex/vav-535-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-530-duct-after-damper",
+ "@id": "urn:ex/vav-534-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-314"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-534-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-534-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-534-air-out"
+ }
]
},
{
- "@id": "urn:ex/vav-534-damper-actuator",
+ "@id": "urn:ex/vav-526-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-damper"
+ "@id": "urn:ex/vav-526-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-534-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-502-damper-in",
+ "@id": "urn:ex/vav-530-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-530-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-502-air-in"
- }
]
},
{
- "@id": "urn:ex/zone-106-107-temp",
+ "@id": "urn:ex/vav-529-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-206-co2-sensor",
+ "@id": "urn:ex/vav-515-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-206-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-206-co2-concentration"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-cooling-pid-output",
+ "@id": "urn:ex/vav-502-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-502-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-506-damper-command",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -28435,179 +28230,150 @@
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan",
+ "@id": "urn:ex/vav-532-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-532-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-533-damper-command",
+ "@id": "urn:ex/office-ahu-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-202-occupancy",
+ "@id": "urn:ex/vav-539-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-516-discharge-air-flow",
+ "@id": "urn:ex/connection-to-room-116-117",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-111",
+ "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-504-cooling-pid-output",
+ "@id": "urn:ex/zone-303-304-306",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/room-303-hvac-domain"
+ },
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-512-reheat-coil-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/room-304-hvac-domain"
+ },
{
- "@id": "urn:ex/vav-512-duct-after-damper"
+ "@id": "urn:ex/room-306-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:ex/vav-517-cooling-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/zone-303-304-306-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-303-304-306-temp"
+ },
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/zone-303-304-306-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/office-ahu-air-filter-in",
+ "@id": "urn:ex/vav-520-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-oa-ra-damper"
+ "@id": "urn:ex/vav-520-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/office-ahu-ma-temp"
+ "@id": "urn:ex/vav-520-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-534-damper-position",
+ "@id": "urn:ex/zone-115-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-522-damper-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-522-damper"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
- {
- "@id": "urn:ex/vav-522-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-535-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -28623,153 +28389,124 @@
]
},
{
- "@id": "urn:ex/vav-511-hot-water-in-connection",
+ "@id": "urn:ex/zone-307-308-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-302-hvac-domain",
+ "@id": "urn:ex/zone-309-310-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-302-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-302-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-command",
+ "@id": "urn:ex/office-ahu-ra-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-ra-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/office-ahu-ra-temp"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-527-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-208-out",
+ "@id": "urn:ex/vav-534-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-314"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-102",
- "@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-102-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-102-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-102-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-102-occupancy"
+ "@id": "urn:ex/vav-534-discharge-air-flow"
},
{
- "@id": "urn:ex/zone-102-occupancy-override"
+ "@id": "urn:ex/vav-534-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/zone-102-temp"
+ "@id": "urn:ex/vav-534-discharge-air-temp"
},
{
- "@id": "urn:ex/zone-102-window-switch-on-off"
+ "@id": "urn:ex/vav-534-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-out",
+ "@id": "urn:ex/zone-111-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/room-111-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-111-temp"
}
]
},
{
- "@id": "urn:ex/zone-102-occupancy-override",
+ "@id": "urn:ex/vav-531-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-531-hot-water-in-connection"
}
- ]
- },
- {
- "@id": "urn:ex/vav-540-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28778,40 +28515,23 @@
]
},
{
- "@id": "urn:ex/zone-313-occupancy-override",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-309-310-occupancy-override",
+ "@id": "urn:ex/vav-502-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/zone-102-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-532-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-108-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -28827,19 +28547,23 @@
]
},
{
- "@id": "urn:ex/vav-522-duct-after-damper",
+ "@id": "urn:ex/vav-531-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/zone-207-temp",
+ "@id": "urn:ex/zone-311-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -28855,46 +28579,44 @@
]
},
{
- "@id": "urn:ex/vav-526-damper",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-damper-in"
- },
- {
- "@id": "urn:ex/vav-526-damper-out"
+ "@id": "urn:ex/vav-534-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-526-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-526-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-513-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-513-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-513-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-502-discharge-air-flow",
+ "@id": "urn:ex/vav-536-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -28915,233 +28637,304 @@
]
},
{
- "@id": "urn:ex/vav-525-cooling-pid-output",
+ "@id": "urn:ex/room-202",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/room-202-hvac-domain"
}
]
},
{
- "@id": "urn:ex/room-113-out",
+ "@id": "urn:ex/vav-516-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-516-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-516-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-out",
+ "@id": "urn:ex/vav-537-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-529-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-colder-supply-air-requests"
+ "@id": "urn:ex/vav-508-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-529-cooling-pid-output"
+ "@id": "urn:ex/vav-508-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-508-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-position",
+ "@id": "urn:ex/vav-535-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-103",
+ "@id": "urn:ex/room-116-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-103-hvac-domain"
+ "@id": "urn:ex/connection-to-room-116-117"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-511",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-103-cooling-setpoint"
+ "@id": "urn:ex/vav-511-air-in"
},
{
- "@id": "urn:ex/zone-103-heating-setpoint"
+ "@id": "urn:ex/vav-511-air-out"
},
{
- "@id": "urn:ex/zone-103-occupancy"
+ "@id": "urn:ex/vav-511-hot-water-in"
},
{
- "@id": "urn:ex/zone-103-occupancy-override"
+ "@id": "urn:ex/vav-511-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-511-damper"
},
{
- "@id": "urn:ex/zone-103-temp"
+ "@id": "urn:ex/vav-511-reheat-coil"
},
{
- "@id": "urn:ex/zone-103-window-switch-on-off"
+ "@id": "urn:ex/vav-511-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-508-damper-position",
+ "@id": "urn:ex/office-ahu-htg-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-duct-after-air-filter"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-515-damper-actuator",
+ "@id": "urn:ex/vav-535-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-damper"
+ "@id": "urn:ex/vav-535-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-515-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-535-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-flow",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-524-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-524-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-530-discharge-air-flow",
+ "@id": "urn:ex/vav-510-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-504-damper-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-504-air-in"
}
]
},
{
- "@id": "urn:ex/vav-505-more-heat-requests",
+ "@id": "urn:ex/vav-533-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-515-heating-pid-output",
+ "@id": "urn:ex/vav-522-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-522-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-valve-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-522-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-air-in",
+ "@id": "urn:ex/office-ahu-connection-from-rooms",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-503-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-118",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-118-hvac-domain"
}
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-position",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -29157,23 +28950,59 @@
]
},
{
- "@id": "urn:ex/vav-526-discharge-air-flow-setpoint",
+ "@id": "urn:ex/zone-312-heating-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-516-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-303-304-306",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -29189,329 +29018,332 @@
]
},
{
- "@id": "urn:ex/connection-to-room-111",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil-water-in",
+ "@id": "urn:ex/vav-528-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-502-hot-water-in"
+ "@id": "urn:ex/vav-528-air-in"
}
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-305-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-air-in"
+ "@id": "urn:ex/room-305-in"
+ },
+ {
+ "@id": "urn:ex/room-305-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-533-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/office-ahu-air-filter-out",
+ "@id": "urn:ex/vav-524-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-air-filter"
+ "@id": "urn:ex/connection-to-room-210"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-512-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-538-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
+ "@id": "urn:ex/vav-524-discharge-air-flow"
+ },
{
- "@id": "urn:ex/vav-538-reheat-coil-valve"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "@id": "urn:ex/vav-524-discharge-air-flow-setpoint"
+ },
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-524-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-524-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/zone-112-114-temp",
+ "@id": "urn:ex/vav-525-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-115-cooling-setpoint",
+ "@id": "urn:ex/vav-516-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-536-more-heat-requests",
+ "@id": "urn:ex/vav-520-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/vav-502-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-520-air-in"
}
]
},
{
- "@id": "urn:ex/vav-509-hot-water-in-connection",
+ "@id": "urn:ex/vav-535-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-522-more-heat-requests",
+ "@id": "urn:ex/vav-529-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-201-temp",
+ "@id": "urn:ex/vav-531-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-518-colder-supply-air-requests",
+ "@id": "urn:ex/vav-538-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-538-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-538-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-538-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-538-hot-water-out-connection",
+ "@id": "urn:ex/vav-527-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-out",
+ "@id": "urn:ex/vav-517-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ "@id": "urn:ex/connection-to-room-203"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-505-discharge-air-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-505-air-out"
+ "@id": "urn:ex/vav-517-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-517-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-505-discharge-air-temp"
+ "@id": "urn:ex/vav-517-air-out"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-flow",
+ "@id": "urn:ex/office-ahu-ra-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/connection-to-room-104",
+ "@id": "urn:ex/zone-313-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-206-co2-concentration",
+ "@id": "urn:ex/vav-507-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#ofSubstance": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Substance-CO2"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PPM"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-539-damper-in",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-514-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-514-reheat-coil-valve-command"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-311-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-539-air-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/room-109-out",
+ "@id": "urn:ex/room-109-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-109"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -29521,135 +29353,174 @@
]
},
{
- "@id": "urn:ex/zone-212-temp-sensor",
+ "@id": "urn:ex/zone-210-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-212-hvac-domain"
+ "@id": "urn:ex/room-210-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-212-temp"
+ "@id": "urn:ex/zone-210-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-522-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-522-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-522-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-water-in",
+ "@id": "urn:ex/vav-539-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-512-hot-water-in-connection"
+ "@id": "urn:ex/vav-539-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-valve-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-512-hot-water-in"
+ "@id": "urn:ex/vav-502-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-535-air-out",
+ "@id": "urn:ex/zone-109",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-311"
+ "@id": "urn:ex/room-109-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-535-discharge-air-flow"
+ "@id": "urn:ex/zone-109-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-535-discharge-air-flow-setpoint"
+ "@id": "urn:ex/zone-109-heating-setpoint"
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp"
+ "@id": "urn:ex/zone-109-occupancy"
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp-setpoint"
+ "@id": "urn:ex/zone-109-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-109-temp"
+ },
+ {
+ "@id": "urn:ex/zone-109-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-519-reheat-coil-air-out",
+ "@id": "urn:ex/vav-503-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-204-205"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-206-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-519-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-519-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523-pipe-hot-water-return-before-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-519-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-210-cooling-setpoint",
+ "@id": "urn:ex/room-311-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/connection-to-room-115",
+ "@id": "urn:ex/office-ahu-oa-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -29661,365 +29532,381 @@
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-515-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-515-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-515-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-515-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-503-hot-water-in",
+ "@id": "urn:ex/vav-533-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-503-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-311",
+ "@id": "urn:ex/vav-505-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-311-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-112-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/connection-to-room-112-114"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-311-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-311-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-311-occupancy"
- },
- {
- "@id": "urn:ex/zone-311-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-311-temp"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-311-window-switch-on-off"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-213-hvac-domain",
+ "@id": "urn:ex/vav-501-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-213-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-213-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-520-hot-water-in-connection",
+ "@id": "urn:ex/zone-301-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-514-discharge-air-flow",
+ "@id": "urn:ex/vav-510-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-510-air-out"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-510-discharge-air-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-208-209-window-switch-on-off",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/connection-to-room-101",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-537-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-537-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve",
+ "@id": "urn:ex/vav-502",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-502-air-in"
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-502-air-out"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-502-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-502-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-command"
+ "@id": "urn:ex/vav-502-damper"
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-502-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-502-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-103-occupancy",
+ "@id": "urn:ex/vav-508-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/zone-110",
+ "@id": "urn:ex/vav-510-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/room-110-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-110-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-110-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-110-occupancy"
- },
- {
- "@id": "urn:ex/zone-110-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-110-temp"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-110-window-switch-on-off"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-215",
+ "@id": "urn:ex/vav-526-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-215-hvac-domain"
+ "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-521-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-513-air-in"
+ "@id": "urn:ex/vav-521-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-513-discharge-air-flow"
+ "@id": "urn:ex/vav-521-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-114-hvac-domain",
+ "@id": "urn:ex/vav-520-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-114-in"
+ "@id": "urn:ex/vav-520-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/room-114-out"
+ "@id": "urn:ex/vav-520-reheat-coil-valve-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-531-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-520-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-520-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-515-damper",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-damper-in"
- },
- {
- "@id": "urn:ex/vav-515-damper-out"
+ "@id": "urn:ex/vav-510-hot-water-out-connection"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-515-damper-command"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-515-damper-position"
+ "@id": "urn:ex/vav-510-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-537-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-527-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-513-damper-command",
+ "@id": "urn:ex/office-ahu-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-537-discharge-air-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-in",
+ "@id": "urn:ex/vav-512-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-538-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-520-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-511-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-506-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-529-hot-water-out-connection",
+ "@id": "urn:ex/vav-526-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -30031,10 +29918,15 @@
]
},
{
- "@id": "urn:ex/zone-307-308-temp",
+ "@id": "urn:ex/vav-533-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
+ "http://data.ashrae.org/standard223#hasAspect": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/Temperature"
@@ -30047,284 +29939,296 @@
]
},
{
- "@id": "urn:ex/zone-118-occupancy-override",
+ "@id": "urn:ex/vav-502-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
- ]
- },
- {
- "@id": "urn:ex/zone-112-114-cooling-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-517-damper",
+ "@id": "urn:ex/vav-516-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-damper-in"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-517-damper-out"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-517-damper-command"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-517-damper-position"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-out",
+ "@id": "urn:ex/zone-215-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-522-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-501-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-522-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-503-air-out",
+ "@id": "urn:ex/vav-528-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-104"
+ "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-102-occupancy-override",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-503-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-503-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-503-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-503-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/room-102-hvac-domain",
+ "@id": "urn:ex/vav-509-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-102-in"
- },
+ "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-102-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-312",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-512-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-air-in"
+ "@id": "urn:ex/vav-512-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-537-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-512-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-512-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/office-ahu-connection-to-vavs",
+ "@id": "urn:ex/vav-530-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-509-damper-command",
+ "@id": "urn:ex/vav-536-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-531-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-air-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-520-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-water-out",
+ "@id": "urn:ex/room-308-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-307-308"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-527-cooling-pid-output",
+ "@id": "urn:ex/vav-540-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-518-more-heat-requests",
+ "@id": "urn:ex/zone-105-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-533-more-heat-requests",
+ "@id": "urn:ex/vav-526-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-313",
+ "@id": "urn:ex/vav-534-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "urn:ex/vav-534-duct-after-damper"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-313-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-313-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-313-occupancy"
- },
- {
- "@id": "urn:ex/zone-313-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-313-temp"
+ "@id": "urn:ex/vav-534-colder-supply-air-requests"
},
{
- "@id": "urn:ex/zone-313-window-switch-on-off"
+ "@id": "urn:ex/vav-534-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-535-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -30333,14 +30237,10 @@
]
},
{
- "@id": "urn:ex/vav-517-hot-water-in",
+ "@id": "urn:ex/vav-503-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-517-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -30349,70 +30249,78 @@
]
},
{
- "@id": "urn:ex/vav-534-damper",
+ "@id": "urn:ex/vav-521",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-534-damper-in"
+ "@id": "urn:ex/vav-521-air-in"
},
{
- "@id": "urn:ex/vav-534-damper-out"
+ "@id": "urn:ex/vav-521-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-521-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-521-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-534-damper-command"
+ "@id": "urn:ex/vav-521-damper"
},
{
- "@id": "urn:ex/vav-534-damper-position"
+ "@id": "urn:ex/vav-521-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-521-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-515-damper-out",
+ "@id": "urn:ex/vav-501-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-duct-after-damper"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-501-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-501-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-colder-supply-air-requests"
+ "@id": "urn:ex/vav-501-damper-command"
},
{
- "@id": "urn:ex/vav-515-cooling-pid-output"
+ "@id": "urn:ex/vav-501-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-510-reheat-coil-valve-position",
+ "@id": "urn:ex/room-314-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/connection-to-room-314"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-529-discharge-air-temp",
+ "@id": "urn:ex/vav-526-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -30433,269 +30341,254 @@
]
},
{
- "@id": "urn:ex/vav-520-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-202-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-air-in"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-520-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-out",
+ "@id": "urn:ex/office-ahu-htg-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-htg-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-hot-water-out"
+ "@id": "urn:ex/office-ahu-htg-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-htg-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-528-discharge-air-flow",
+ "@id": "urn:ex/vav-503-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-516-discharge-air-temp-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-533-hot-water-out",
+ "@id": "urn:ex/zone-314-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-533-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/room-116-in",
+ "@id": "urn:ex/office-ahu-chilled-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-116-117"
+ "@id": "urn:ex/office-ahu-chilled-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-510-discharge-air-temp",
+ "@id": "urn:ex/vav-531-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/vav-531-damper-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-531-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-531-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-531-damper-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-command",
+ "@id": "urn:ex/vav-526-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-526-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-526-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-511-damper",
+ "@id": "urn:ex/zone-202-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-511-damper-in"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-511-damper-out"
+ "@id": "urn:ex/room-202-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-511-damper-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-511-damper-position"
+ "@id": "urn:ex/zone-202-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-522-damper-in",
+ "@id": "urn:ex/vav-503-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-503-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-522-air-in"
- }
]
},
{
- "@id": "urn:ex/vav-507-damper-out",
+ "@id": "urn:ex/zone-312-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-507-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-507-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-507-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-air-out",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-301"
+ "@id": "urn:ex/vav-539-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-527-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-527-more-heat-requests"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-527-air-out"
+ "@id": "urn:ex/vav-539-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-109-occupancy-sensor",
+ "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-109-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-109-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-516-hot-water-in",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-516-hot-water-in-connection"
+ "@id": "urn:ex/vav-521-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-521-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-515-air-in",
+ "@id": "urn:ex/vav-508-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-508-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -30705,18 +30598,7 @@
]
},
{
- "@id": "urn:ex/zone-212-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-507-hot-water-out-connection",
+ "@id": "urn:ex/vav-509-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -30728,39 +30610,35 @@
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-water-out",
+ "@id": "urn:ex/vav-526-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-526-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-526-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
- ]
- },
- {
- "@id": "urn:ex/vav-503-cooling-pid-output",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:ex/vav-526-reheat-coil-valve-command"
+ },
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-526-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-523-air-in",
+ "@id": "urn:ex/vav-536-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -30776,13 +30654,13 @@
]
},
{
- "@id": "urn:ex/vav-529-hot-water-out",
+ "@id": "urn:ex/vav-515-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-529-hot-water-out-connection"
+ "@id": "urn:ex/vav-515-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -30792,182 +30670,238 @@
]
},
{
- "@id": "urn:ex/room-206-out",
+ "@id": "urn:ex/vav-535-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-in-connection",
+ "@id": "urn:ex/vav-524-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-524-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-524-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-536-hot-water-out-connection",
+ "@id": "urn:ex/vav-533-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-533-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-power",
+ "@id": "urn:ex/vav-538-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-303-304-306-occupancy-override",
+ "@id": "urn:ex/zone-106-107-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/room-106-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-106-107-temp"
}
]
},
{
- "@id": "urn:ex/vav-523-cooling-pid-output",
+ "@id": "urn:ex/vav-511-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-521-more-heat-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-water-out",
+ "@id": "urn:ex/vav-519-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-519-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-519-hot-water-in"
+ }
]
},
{
- "@id": "urn:ex/vav-533-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-101-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/room-101-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-101-temp"
}
]
},
{
- "@id": "urn:ex/vav-508-hot-water-in",
+ "@id": "urn:ex/vav-518-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-309-out",
+ "@id": "urn:ex/vav-511-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-511-air-in"
+ }
]
},
{
- "@id": "urn:ex/zone-102-temp",
+ "@id": "urn:ex/vav-513",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-513-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-513-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-513-damper"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-524-hot-water-in-connection",
+ "@id": "urn:ex/vav-526-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-526-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-520-more-heat-requests",
+ "@id": "urn:ex/vav-505-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -30978,177 +30912,179 @@
]
},
{
- "@id": "urn:ex/vav-524-hot-water-out-connection",
+ "@id": "urn:ex/vav-537-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-212-cooling-setpoint",
+ "@id": "urn:ex/vav-510",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-510-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-510-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-510-hot-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-510-damper"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-510-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-533-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-516-damper",
+ "@id": "urn:ex/vav-527-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-516-damper-in"
- },
- {
- "@id": "urn:ex/vav-516-damper-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-516-damper-command"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-516-damper-position"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-519-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-527-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-527-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-104-heating-setpoint",
+ "@id": "urn:ex/vav-513-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-hot-water-out-connection"
+ "@id": "urn:ex/vav-508-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-536-hot-water-out"
- }
]
},
{
- "@id": "urn:ex/room-301-in",
+ "@id": "urn:ex/vav-513-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/connection-to-room-301"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-310",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-310-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-540-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-510-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-533-heating-pid-output",
+ "@id": "urn:ex/vav-510-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-535-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -31162,42 +31098,44 @@
]
},
{
- "@id": "urn:ex/office-ahu-duct-after-htg-coil",
+ "@id": "urn:ex/vav-514-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-water-out",
+ "@id": "urn:ex/vav-517-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-517-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-517-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-517-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-517-damper-position"
}
]
},
{
- "@id": "urn:ex/room-313-in",
+ "@id": "urn:ex/vav-536-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-313"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -31206,122 +31144,117 @@
]
},
{
- "@id": "urn:ex/zone-111-occupancy",
+ "@id": "urn:ex/zone-204-205-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/room-117-out",
+ "@id": "urn:ex/vav-509-damper-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-509-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-502-reheat-coil-air-out"
- },
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-502-reheat-coil-water-in"
+ "@id": "urn:ex/vav-509-colder-supply-air-requests"
},
{
- "@id": "urn:ex/vav-502-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/vav-509-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-215-temp",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-540-hot-water-out-connection",
+ "@id": "urn:ex/office-ahu-ra-damper",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-ra-damper-in"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-damper-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-524-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-ra-damper-command"
+ },
+ {
+ "@id": "urn:ex/office-ahu-ra-damper-position"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-command"
+ "@id": "http://data.ashrae.org/standard223#Role-Return"
}
]
},
{
- "@id": "urn:ex/room-101-in",
+ "@id": "urn:ex/vav-528-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-101"
+ "@id": "urn:ex/connection-to-room-302"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-528-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-528-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-528-air-out"
+ }
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -31335,293 +31268,280 @@
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-515-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-517-hot-water-out-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-515-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-517-hot-water-out"
+ "@id": "urn:ex/vav-515-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-valve",
+ "@id": "urn:ex/vav-520-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-506-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-520-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-506-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-506-reheat-coil-valve-position"
+ "@id": "urn:ex/vav-520-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-208-209-window-switch-on-off",
+ "@id": "urn:ex/vav-506-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-524-air-out",
+ "@id": "urn:ex/zone-104",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/connection-to-room-210"
+ "@id": "urn:ex/room-104-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-discharge-air-flow"
+ "@id": "urn:ex/zone-104-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-524-discharge-air-flow-setpoint"
+ "@id": "urn:ex/zone-104-heating-setpoint"
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp"
+ "@id": "urn:ex/zone-104-occupancy"
},
{
- "@id": "urn:ex/vav-524-discharge-air-temp-setpoint"
+ "@id": "urn:ex/zone-104-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-104-temp"
+ },
+ {
+ "@id": "urn:ex/zone-104-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-in",
+ "@id": "urn:ex/vav-523-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-ra-fan"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-523-air-in"
+ }
]
},
{
- "@id": "urn:ex/zone-312-window-switch-on-off",
+ "@id": "urn:ex/vav-537-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-113-window-switch-on-off",
+ "@id": "urn:ex/vav-512-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/zone-201-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/room-207-hvac-domain",
+ "@id": "urn:ex/vav-510-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-207-in"
- },
- {
- "@id": "urn:ex/room-207-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-511-hot-water-out-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-511-hot-water-out"
+ }
]
},
{
- "@id": "urn:ex/vav-507-discharge-air-temp",
+ "@id": "urn:ex/vav-526-cooling-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-508",
+ "@id": "urn:ex/vav-505-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-508-air-in"
- },
- {
- "@id": "urn:ex/vav-508-air-out"
- },
- {
- "@id": "urn:ex/vav-508-hot-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-508-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-508-damper"
- },
- {
- "@id": "urn:ex/vav-508-reheat-coil"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-508-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-531-hot-water-in",
+ "@id": "urn:ex/vav-539-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-531-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-512-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-512-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-524-damper-out",
+ "@id": "urn:ex/vav-530-reheat-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-duct-after-damper"
+ "@id": "urn:ex/vav-530-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-524-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-524-cooling-pid-output"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-522-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-522-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -31631,37 +31551,31 @@
]
},
{
- "@id": "urn:ex/vav-512-air-out",
+ "@id": "urn:ex/vav-518-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-118"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-529-hot-water-out-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-512-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-512-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-512-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-512-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-203-heating-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -31677,59 +31591,51 @@
]
},
{
- "@id": "urn:ex/connection-to-room-215",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-514-damper-out",
+ "@id": "urn:ex/vav-528-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-duct-after-damper"
+ "@id": "urn:ex/vav-528-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-514-colder-supply-air-requests"
+ "@id": "urn:ex/vav-528-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-514-cooling-pid-output"
+ "@id": "urn:ex/vav-528-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/zone-313-occupancy-sensor",
+ "@id": "urn:ex/vav-539-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-313-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-313-occupancy"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-522-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -31745,131 +31651,158 @@
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-512-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-504-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-512-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-air-out"
+ "@id": "urn:ex/vav-512-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-504-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-504-reheat-coil-valve-command",
+ "@id": "urn:ex/zone-101-building-static-pressure-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
]
},
{
- "@id": "urn:ex/zone-101-occupancy",
+ "@id": "urn:ex/zone-213-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/room-213-hvac-domain"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/zone-213-temp"
}
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-water-in",
+ "@id": "urn:ex/vav-504-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-504-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-504-damper-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-524-hot-water-in"
+ "@id": "urn:ex/vav-504-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-504-damper-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-water-in",
+ "@id": "urn:ex/vav-512-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-chilled-water-in-connection"
+ "@id": "urn:ex/vav-512-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-512-discharge-air-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-528-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-114-hvac-domain",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-colder-chilled-water-requests"
+ "@id": "urn:ex/room-114-in"
+ },
+ {
+ "@id": "urn:ex/room-114-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/office-ahu-chilled-water-in"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/connection-to-room-204-205",
+ "@id": "urn:ex/zone-302-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-533-air-in",
+ "@id": "urn:ex/room-114-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -31879,126 +31812,117 @@
]
},
{
- "@id": "urn:ex/vav-503-reheat-coil-water-in",
+ "@id": "urn:ex/zone-212-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-503-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-108-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-108-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-503-hot-water-in"
+ "@id": "urn:ex/zone-108-temp"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil",
+ "@id": "urn:ex/office-ahu-ea-out",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-528-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-528-reheat-coil-water-out"
+ "@id": "urn:ex/office-ahu-ea-out-connection"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-out",
+ "@id": "urn:ex/zone-307-308",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/vav-526-duct-after-damper"
+ "@id": "urn:ex/room-307-hvac-domain"
+ },
+ {
+ "@id": "urn:ex/room-308-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-526-colder-supply-air-requests"
+ "@id": "urn:ex/zone-307-308-cooling-setpoint"
},
{
- "@id": "urn:ex/vav-526-cooling-pid-output"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-516-reheat-coil",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-516-reheat-coil-air-in"
+ "@id": "urn:ex/zone-307-308-heating-setpoint"
},
{
- "@id": "urn:ex/vav-516-reheat-coil-air-out"
+ "@id": "urn:ex/zone-307-308-occupancy"
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-in"
+ "@id": "urn:ex/zone-307-308-occupancy-override"
},
{
- "@id": "urn:ex/vav-516-reheat-coil-water-out"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:ex/zone-307-308-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:ex/zone-307-308-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-position",
+ "@id": "urn:ex/office-ahu-moisture-eliminator-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/office-ahu-oa-in-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/office-ahu-oa-in"
}
]
},
{
- "@id": "urn:ex/vav-520-hot-water-in",
+ "@id": "urn:ex/office-ahu-chilled-water-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-chilled-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -32008,99 +31932,90 @@
]
},
{
- "@id": "urn:ex/vav-523-damper-position",
+ "@id": "urn:ex/vav-527-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-damper-command",
+ "@id": "urn:ex/vav-540-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-command",
+ "@id": "urn:ex/room-213-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-213-in"
+ },
+ {
+ "@id": "urn:ex/room-213-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-in",
+ "@id": "urn:ex/zone-118-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-535-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-118-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/connection-to-room-312",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-118-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-507-hot-water-in",
+ "@id": "urn:ex/zone-116-117-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-507-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-512-discharge-air-temp",
+ "@id": "urn:ex/vav-508-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -32121,412 +32036,309 @@
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-air-out",
+ "@id": "urn:ex/room-109-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-206"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-523-heating-pid-output"
+ "@id": "urn:ex/room-109-in"
},
{
- "@id": "urn:ex/vav-523-more-heat-requests"
+ "@id": "urn:ex/room-109-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-523-air-out"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-503-air-in",
+ "@id": "urn:ex/vav-525-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/connection-to-room-211"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-525-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil-valve-actuator",
- "@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-510-reheat-coil-valve"
- }
- ],
- "http://data.ashrae.org/standard223#commandedByProperty": [
- {
- "@id": "urn:ex/vav-510-reheat-coil-valve-command"
- }
- ]
- },
- {
- "@id": "urn:ex/zone-106-107",
- "@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/room-106-hvac-domain"
+ "@id": "urn:ex/vav-525-heating-pid-output"
},
{
- "@id": "urn:ex/room-107-hvac-domain"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-525-more-heat-requests"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-106-107-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-106-107-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-106-107-occupancy"
- },
- {
- "@id": "urn:ex/zone-106-107-occupancy-override"
- },
- {
- "@id": "urn:ex/zone-106-107-temp"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-106-107-window-switch-on-off"
+ "@id": "urn:ex/vav-525-air-out"
}
]
},
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-528-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-535-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-flow-sensor",
+ "@id": "urn:ex/zone-312-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-ra-in"
+ "@id": "urn:ex/room-312-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/office-ahu-ra-flow"
+ "@id": "urn:ex/zone-312-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-valve-position",
+ "@id": "urn:ex/zone-208-209-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-208-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/zone-208-209-temp"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-109-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-527-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-312-hvac-domain",
+ "@id": "urn:ex/vav-527-damper",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-312-in"
+ "@id": "urn:ex/vav-527-damper-in"
},
{
- "@id": "urn:ex/room-312-out"
+ "@id": "urn:ex/vav-527-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-527-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-527-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-523-heating-pid-output",
+ "@id": "urn:ex/vav-514-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-531-air-in",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-514-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-514-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-538-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-538-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-538-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-509-discharge-air-temp-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-117-hvac-domain",
+ "@id": "urn:ex/vav-506-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-117-in"
- },
- {
- "@id": "urn:ex/room-117-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-501-damper-out",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-501-duct-after-damper"
+ "@id": "urn:ex/vav-516-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-501-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-501-cooling-pid-output"
+ "@id": "urn:ex/vav-516-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-actuator",
+ "@id": "urn:ex/zone-208-209-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-517",
+ "@id": "urn:ex/zone-202-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-517-air-in"
- },
- {
- "@id": "urn:ex/vav-517-air-out"
- },
- {
- "@id": "urn:ex/vav-517-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-517-hot-water-out"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-517-damper"
- },
- {
- "@id": "urn:ex/vav-517-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-517-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-526-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-505-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-526-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/office-ahu-ra-fan-speed-status",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-512-reheat-coil-air-out",
+ "@id": "urn:ex/vav-537-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-118"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -32534,104 +32346,106 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-512-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-512-more-heat-requests"
- }
- ],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-512-air-out"
+ "@id": "urn:ex/vav-537-air-in"
}
]
},
{
- "@id": "urn:ex/vav-501-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-511-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-511-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-210-window-switch-on-off",
+ "@id": "urn:ex/vav-520-colder-supply-air-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-533",
+ "@id": "urn:ex/vav-536-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-air-in"
+ "@id": "urn:ex/vav-536-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-533-air-out"
+ "@id": "urn:ex/vav-536-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-533-hot-water-in"
+ "@id": "urn:ex/vav-536-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-533-hot-water-out"
+ "@id": "urn:ex/vav-536-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-533-damper"
- },
- {
- "@id": "urn:ex/vav-533-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:ex/vav-533-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-536-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/office-ahu-htg-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-104-occupancy-override",
+ "@id": "urn:ex/vav-532-damper",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-532-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-532-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-532-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-532-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-506-colder-supply-air-requests",
+ "@id": "urn:ex/vav-522-more-heat-requests",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -32642,106 +32456,132 @@
]
},
{
- "@id": "urn:ex/room-309",
+ "@id": "urn:ex/vav-539-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/room-309-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-509-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-301-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-air-in"
+ "@id": "urn:ex/room-301-in"
+ },
+ {
+ "@id": "urn:ex/room-301-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-509-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-513-duct-after-damper",
+ "@id": "urn:ex/vav-540-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-air-in",
+ "@id": "urn:ex/zone-101-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-518-duct-after-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-505-hot-water-in-connection",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-512-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-515-cooling-pid-output",
+ "@id": "urn:ex/zone-104-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-104-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/zone-104-temp"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil",
+ "@id": "urn:ex/vav-506-reheat-coil",
"@type": [
"http://data.ashrae.org/standard223#HeatingCoil",
"http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-reheat-coil-air-in"
+ "@id": "urn:ex/vav-506-reheat-coil-air-in"
},
{
- "@id": "urn:ex/vav-509-reheat-coil-air-out"
+ "@id": "urn:ex/vav-506-reheat-coil-air-out"
},
{
- "@id": "urn:ex/vav-509-reheat-coil-water-in"
+ "@id": "urn:ex/vav-506-reheat-coil-water-in"
},
{
- "@id": "urn:ex/vav-509-reheat-coil-water-out"
+ "@id": "urn:ex/vav-506-reheat-coil-water-out"
}
],
"http://data.ashrae.org/standard223#hasRole": [
@@ -32751,313 +32591,265 @@
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-105-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-536-air-in"
+ "@id": "urn:ex/room-105-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-536-discharge-air-flow"
+ "@id": "urn:ex/zone-105-temp"
}
]
},
{
- "@id": "urn:ex/vav-516-reheat-coil-valve",
+ "@id": "urn:ex/zone-309-310-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-in"
- },
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-out"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/room-309-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-516-reheat-coil-valve-command"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-516-reheat-coil-valve-position"
+ "@id": "urn:ex/zone-309-310-temp"
}
]
},
{
- "@id": "urn:ex/vav-502-damper-out",
+ "@id": "urn:ex/zone-202-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-502-duct-after-damper"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-502-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-512-heating-pid-output",
+ "@id": "urn:ex/vav-505-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-505-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-505-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-water-in",
+ "@id": "urn:ex/vav-515-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-501-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-515-air-in"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-501-hot-water-in"
+ "@id": "urn:ex/vav-515-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-513-more-heat-requests",
+ "@id": "urn:ex/vav-539-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-539-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-539-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-510",
+ "@id": "urn:ex/zone-215-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-510-air-in"
- },
- {
- "@id": "urn:ex/vav-510-air-out"
- },
- {
- "@id": "urn:ex/vav-510-hot-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-510-hot-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-510-damper"
- },
- {
- "@id": "urn:ex/vav-510-reheat-coil"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-510-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-510-duct-after-damper",
+ "@id": "urn:ex/vav-524-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-colder-supply-air-requests",
+ "@id": "urn:ex/vav-514-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-514-air-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-514-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-out",
+ "@id": "urn:ex/vav-534-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-517-duct-after-damper"
+ "@id": "urn:ex/vav-534-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-517-colder-supply-air-requests"
- },
- {
- "@id": "urn:ex/vav-517-cooling-pid-output"
- }
]
},
{
- "@id": "urn:ex/vav-540-air-out",
+ "@id": "urn:ex/room-201-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-215"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-540-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-540-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-540-discharge-air-temp"
- },
- {
- "@id": "urn:ex/vav-540-discharge-air-temp-setpoint"
- }
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-temp",
+ "@id": "urn:ex/vav-535-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-507-damper-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/room-206",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "urn:ex/vav-507-air-in"
}
]
},
{
- "@id": "urn:ex/room-112-hvac-domain",
+ "@id": "urn:ex/vav-525-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-112-in"
+ "@id": "urn:ex/vav-525-reheat-coil-air-in"
},
{
- "@id": "urn:ex/room-112-out"
+ "@id": "urn:ex/vav-525-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-201-occupancy",
+ "@id": "urn:ex/connection-to-room-201",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-105-hvac-domain",
+ "@id": "urn:ex/vav-508-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-105-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-105-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-311-occupancy",
+ "@id": "urn:ex/zone-213-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -33068,13 +32860,13 @@
]
},
{
- "@id": "urn:ex/vav-524-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-524-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-hot-water-out-connection"
+ "@id": "urn:ex/vav-524-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33084,390 +32876,412 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-524-hot-water-out"
+ "@id": "urn:ex/vav-524-hot-water-in"
}
]
},
{
- "@id": "urn:ex/zone-109-temp-sensor",
+ "@id": "urn:ex/connection-to-room-203",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-109-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-109-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-position",
+ "@id": "urn:ex/vav-519-heating-pid-output",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/zone-111-cooling-setpoint",
+ "@id": "urn:ex/vav-525-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-310",
+ "@id": "urn:ex/vav-510-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-310-hvac-domain"
+ "@id": "urn:ex/vav-510-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:ex/vav-510-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-air-in",
+ "@id": "urn:ex/vav-527-air-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-301"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-527-discharge-air-flow"
+ },
+ {
+ "@id": "urn:ex/vav-527-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-527-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-527-discharge-air-temp-setpoint"
+ }
]
},
{
- "@id": "urn:ex/vav-521-hot-water-in",
+ "@id": "urn:ex/room-310-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-521-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-502-damper-position",
+ "@id": "urn:ex/zone-118-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-504-hot-water-in-connection",
+ "@id": "urn:ex/connection-to-room-302",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-539-duct-after-damper",
+ "@id": "urn:ex/vav-517-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil",
+ "@id": "urn:ex/vav-510-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-505-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-505-reheat-coil-air-out"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-505-reheat-coil-water-in"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-505-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-312-in",
+ "@id": "urn:ex/vav-501-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-312"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil",
+ "@id": "urn:ex/vav-531-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-536-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-536-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-536-reheat-coil-water-in"
- },
- {
- "@id": "urn:ex/vav-536-reheat-coil-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-101-occupancy-sensor",
+ "@id": "urn:ex/room-209-out",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-101-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-202-heating-setpoint",
+ "@id": "urn:ex/vav-537-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-537-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-temp",
+ "@id": "urn:ex/zone-314",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/room-314-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/zone-314-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-314-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-314-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-314-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-314-temp"
+ },
+ {
+ "@id": "urn:ex/zone-314-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-air-out",
+ "@id": "urn:ex/vav-538-hot-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-202"
+ "@id": "urn:ex/vav-538-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-518",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-heating-pid-output"
+ "@id": "urn:ex/vav-518-air-in"
},
- {
- "@id": "urn:ex/vav-518-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
{
"@id": "urn:ex/vav-518-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-518-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-518-hot-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-502-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-518-damper"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-508-discharge-air-flow",
+ "@id": "urn:ex/zone-307-308-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-532-heating-pid-output",
+ "@id": "urn:ex/vav-508-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-508-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/vav-508-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-518-air-in",
+ "@id": "urn:ex/vav-528-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-528-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-528-reheat-coil-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-525-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-522-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-525-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-208-209"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-525-hot-water-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-526-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:ex/vav-522-discharge-air-flow"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-522-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-522-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-522-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-533-damper-position",
+ "@id": "urn:ex/vav-510-reheat-coil-valve-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -33483,66 +33297,56 @@
]
},
{
- "@id": "urn:ex/room-112-in",
+ "@id": "urn:ex/room-214",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-112-114"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-214-hvac-domain"
}
]
},
{
- "@id": "urn:ex/zone-201-cooling-setpoint",
+ "@id": "urn:ex/vav-520-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-520-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-water-in",
+ "@id": "urn:ex/vav-531-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-513-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-531-damper"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-513-hot-water-in"
+ "@id": "urn:ex/vav-531-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-air-out",
+ "@id": "urn:ex/vav-516-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-108"
+ "@id": "urn:ex/connection-to-room-201"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33552,48 +33356,21 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-505-heating-pid-output"
+ "@id": "urn:ex/vav-516-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-505-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-505-air-out"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ]
- },
- {
- "@id": "urn:ex/room-110-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:ex/vav-516-discharge-air-flow-setpoint"
+ },
{
- "@id": "urn:ex/connection-to-room-110"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-516-discharge-air-temp"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-516-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-527-duct-after-damper",
+ "@id": "urn:ex/office-ahu-ea-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -33605,106 +33382,105 @@
]
},
{
- "@id": "urn:ex/zone-111-temp-sensor",
+ "@id": "urn:ex/zone-108-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-111-hvac-domain"
+ "@id": "urn:ex/room-108-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-111-temp"
+ "@id": "urn:ex/zone-108-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-113-occupancy-sensor",
+ "@id": "urn:ex/vav-506-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-113-hvac-domain"
+ "@id": "urn:ex/vav-506-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-113-occupancy"
+ "@id": "urn:ex/vav-506-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-305-hvac-domain",
+ "@id": "urn:ex/vav-518-damper",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-305-in"
+ "@id": "urn:ex/vav-518-damper-in"
},
{
- "@id": "urn:ex/room-305-out"
+ "@id": "urn:ex/vav-518-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/vav-518-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-518-damper-position"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-power",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:ex/vav-536-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/W"
+ "@id": "urn:ex/vav-536-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-517-reheat-coil-water-in",
+ "@id": "urn:ex/zone-203-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-517-hot-water-in-connection"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-517-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/room-109",
+ "@id": "urn:ex/vav-528-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-528-pipe-hot-water-return-before-valve"
+ }
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-109-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-hot-water-out-connection",
+ "@id": "urn:ex/vav-508-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -33716,55 +33492,78 @@
]
},
{
- "@id": "urn:ex/vav-505-discharge-air-temp",
+ "@id": "urn:ex/vav-518-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-534-hot-water-in-connection",
+ "@id": "urn:ex/vav-528-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-528-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-506-duct-after-damper",
+ "@id": "urn:ex/vav-524-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-524-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-524-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-517-duct-after-damper",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/room-103-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -33773,112 +33572,92 @@
]
},
{
- "@id": "urn:ex/zone-206-temp-sensor",
+ "@id": "urn:ex/zone-204-205-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "urn:ex/room-204-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-206-temp"
+ "@id": "urn:ex/zone-204-205-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-307-308-occupancy-override",
+ "@id": "urn:ex/zone-115-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-203",
+ "@id": "urn:ex/vav-515-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-203-hvac-domain"
+ "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-205-hvac-domain",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-203-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-203-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-203-occupancy"
- },
- {
- "@id": "urn:ex/zone-203-occupancy-override"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-203-temp"
+ "@id": "urn:ex/room-205-in"
},
{
- "@id": "urn:ex/zone-203-window-switch-on-off"
+ "@id": "urn:ex/room-205-out"
}
- ]
- },
- {
- "@id": "urn:ex/zone-313-window-switch-on-off",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-515-air-out",
+ "@id": "urn:ex/vav-511-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-116-117"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:ex/vav-511-damper-in"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-511-damper-out"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-515-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-515-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-515-discharge-air-temp"
+ "@id": "urn:ex/vav-511-damper-command"
},
{
- "@id": "urn:ex/vav-515-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-511-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-temp",
+ "@id": "urn:ex/vav-525-discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -33889,71 +33668,66 @@
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-525-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-535-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-535-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-535-damper-command"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-out",
+ "@id": "urn:ex/room-305",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-ea-out-connection"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/room-305-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-537-heating-pid-output",
+ "@id": "urn:ex/vav-525-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-525-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-205-in",
+ "@id": "urn:ex/vav-534-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-204-205"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -33963,39 +33737,46 @@
]
},
{
- "@id": "urn:ex/zone-110-occupancy-sensor",
+ "@id": "urn:ex/vav-521-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-110-hvac-domain"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-110-occupancy"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-530-damper-actuator",
+ "@id": "urn:ex/vav-534-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-530-damper"
+ "@id": "urn:ex/vav-534-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-530-damper-command"
+ "@id": "urn:ex/vav-534-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-529-damper-position",
+ "@id": "urn:ex/zone-108-occupancy",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-516-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -34011,158 +33792,164 @@
]
},
{
- "@id": "urn:ex/vav-501-duct-after-damper",
+ "@id": "urn:ex/vav-526-more-heat-requests",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-502-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-521-damper-actuator",
+ "@type": [
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-521-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-521-damper-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-312-cooling-setpoint",
+ "@id": "urn:ex/vav-514-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-504-air-in",
+ "@id": "urn:ex/vav-536-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-out",
+ "@id": "urn:ex/room-208-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-533-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-533-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-116-hvac-domain",
+ "@id": "urn:ex/vav-538-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-116-in"
- },
- {
- "@id": "urn:ex/room-116-out"
+ "@id": "urn:ex/vav-538-hot-water-in-connection"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-518-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-503-damper-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
- ]
- },
- {
- "@id": "urn:ex/vav-523-discharge-air-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-523-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-523-discharge-air-temp"
+ "@id": "urn:ex/vav-503-air-in"
}
]
},
{
- "@id": "urn:ex/zone-106-107-occupancy-override",
+ "@id": "urn:ex/zone-203",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/room-203-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/zone-206-occupancy-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/room-206-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/zone-206-occupancy"
+ "@id": "urn:ex/zone-203-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-203-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-203-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-203-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-203-temp"
+ },
+ {
+ "@id": "urn:ex/zone-203-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-536-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-504-discharge-air-flow-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -34178,75 +33965,79 @@
]
},
{
- "@id": "urn:ex/vav-539-damper-out",
+ "@id": "urn:ex/vav-533-reheat-coil-water-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-duct-after-damper"
+ "@id": "urn:ex/vav-533-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-539-colder-supply-air-requests"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-539-cooling-pid-output"
+ "@id": "urn:ex/vav-533-hot-water-in"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-out-connection",
+ "@id": "urn:ex/vav-523-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-523-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil-valve-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-507-air-in",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-523-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-538-discharge-air-temp-setpoint",
+ "@id": "urn:ex/vav-516-damper",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-516-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-516-damper-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-516-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-516-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-116-117-window-switch-on-off",
+ "@id": "urn:ex/zone-313-window-switch-on-off",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -34257,119 +34048,143 @@
]
},
{
- "@id": "urn:ex/vav-506-reheat-coil-water-out",
+ "@id": "urn:ex/connection-to-room-112-114",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-506-pipe-hot-water-return-before-valve"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-504-hot-water-in",
+ "@id": "urn:ex/vav-540-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-504-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-540-air-in"
}
]
},
{
- "@id": "urn:ex/connection-to-room-116-117",
+ "@id": "urn:ex/vav-505-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve",
+ "@id": "urn:ex/vav-536",
"@type": [
- "http://data.ashrae.org/standard223#Valve",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-in"
+ "@id": "urn:ex/vav-536-air-in"
},
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-out"
+ "@id": "urn:ex/vav-536-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-536-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-536-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ "@id": "urn:ex/vav-536-damper"
+ },
+ {
+ "@id": "urn:ex/vav-536-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-536-reheat-coil-valve"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-503-discharge-air-flow-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-command"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve-position"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-sa-fan-in",
+ "@id": "urn:ex/vav-526-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-duct-after-clg-coil"
- }
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-526-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/office-ahu-sa-flow"
+ "@id": "urn:ex/vav-526-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-water-out",
+ "@id": "urn:ex/room-118-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-118"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-531-duct-after-damper",
+ "@id": "urn:ex/vav-519-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-519-duct-after-damper"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -34378,121 +34193,114 @@
]
},
{
- "@id": "urn:ex/room-113",
+ "@id": "urn:ex/room-205-out",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-113-hvac-domain"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
- ]
- },
- {
- "@id": "urn:ex/vav-513-hot-water-in-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-525-damper-command",
+ "@id": "urn:ex/vav-513-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-513-air-in"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-513-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-position",
+ "@id": "urn:ex/zone-106-107-window-switch-on-off",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
}
]
},
{
- "@id": "urn:ex/zone-207-occupancy-sensor",
+ "@id": "urn:ex/vav-516-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/room-207-hvac-domain"
+ "@id": "urn:ex/vav-516-damper"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/zone-207-occupancy"
+ "@id": "urn:ex/vav-516-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-535-discharge-air-temp",
+ "@id": "urn:ex/vav-524-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-307-308-cooling-setpoint",
+ "@id": "urn:ex/vav-501-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-501-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-501-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/office-ahu-clg-coil-air-in",
+ "@id": "urn:ex/vav-539-reheat-coil-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-duct-after-htg-coil"
+ "@id": "urn:ex/vav-539-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -34502,13 +34310,13 @@
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-air-out",
+ "@id": "urn:ex/office-ahu-sa-fan-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-302"
+ "@id": "urn:ex/office-ahu-duct-after-clg-coil"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -34518,79 +34326,82 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-528-heating-pid-output"
- },
+ "@id": "urn:ex/office-ahu-sa-flow"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-535-discharge-air-temp-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-528-more-heat-requests"
+ "@id": "urn:ex/vav-535-air-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-528-air-out"
+ "@id": "urn:ex/vav-535-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-534-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-513-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-213",
+ "@id": "urn:ex/zone-212-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-213-hvac-domain"
+ "@id": "urn:ex/room-212-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:ex/zone-212-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-514-discharge-air-flow-sensor",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-213-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-213-heating-setpoint"
- },
- {
- "@id": "urn:ex/zone-213-occupancy"
- },
- {
- "@id": "urn:ex/zone-213-occupancy-override"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/zone-213-temp"
- },
+ "@id": "urn:ex/vav-514-air-in"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-213-window-switch-on-off"
+ "@id": "urn:ex/vav-514-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-531-damper-out",
+ "@id": "urn:ex/vav-517-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-531-duct-after-damper"
+ "@id": "urn:ex/connection-to-room-203"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -34600,99 +34411,130 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-531-colder-supply-air-requests"
+ "@id": "urn:ex/vav-517-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-531-cooling-pid-output"
+ "@id": "urn:ex/vav-517-discharge-air-flow-setpoint"
+ },
+ {
+ "@id": "urn:ex/vav-517-discharge-air-temp"
+ },
+ {
+ "@id": "urn:ex/vav-517-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-501-hot-water-in",
+ "@id": "urn:ex/vav-506-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-501-hot-water-in-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-535-damper",
+ "@id": "urn:ex/vav-502-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-535-damper-in"
- },
+ "@id": "urn:ex/connection-to-room-101"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-535-damper-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-535-damper-command"
+ "@id": "urn:ex/vav-502-heating-pid-output"
},
{
- "@id": "urn:ex/vav-535-damper-position"
+ "@id": "urn:ex/vav-502-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-502-air-out"
}
]
},
{
- "@id": "urn:ex/vav-534-colder-supply-air-requests",
+ "@id": "urn:ex/vav-536-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper",
+ "@id": "urn:ex/office-ahu-moisture-eliminator",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#AirFilter",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Filter"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ea-damper-in"
+ "@id": "urn:ex/office-ahu-moisture-eliminator-in"
},
{
- "@id": "urn:ex/office-ahu-ea-damper-out"
+ "@id": "urn:ex/office-ahu-moisture-eliminator-out"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-525-reheat-coil-valve-in",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-ea-damper-command"
- },
+ "@id": "urn:ex/vav-525-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-ea-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Exhaust"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-temp",
+ "@id": "urn:ex/vav-517-discharge-air-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Outside"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
@@ -34707,72 +34549,46 @@
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil",
+ "@id": "urn:ex/vav-516-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-htg-coil-air-in"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-air-out"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-water-in"
- },
- {
- "@id": "urn:ex/office-ahu-htg-coil-water-out"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-508-duct-after-damper",
+ "@id": "urn:ex/vav-527-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-527-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-515",
+ "@id": "urn:ex/vav-519-air-in",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-air-in"
- },
- {
- "@id": "urn:ex/vav-515-air-out"
- },
- {
- "@id": "urn:ex/vav-515-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-515-hot-water-out"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-515-damper"
- },
- {
- "@id": "urn:ex/vav-515-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
@@ -34789,225 +34605,217 @@
]
},
{
- "@id": "urn:ex/vav-522",
+ "@id": "urn:ex/vav-530-discharge-air-flow",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-522-air-in"
- },
- {
- "@id": "urn:ex/vav-522-air-out"
- },
- {
- "@id": "urn:ex/vav-522-hot-water-in"
- },
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-522-hot-water-out"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-522-damper"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-522-reheat-coil"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-522-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-temp-sensor",
+ "@id": "urn:ex/zone-101-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-540-air-out"
+ "@id": "urn:ex/room-101-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-540-discharge-air-temp"
+ "@id": "urn:ex/zone-101-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-530-heating-pid-output",
+ "@id": "urn:ex/vav-514-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-514-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-water-out",
+ "@id": "urn:ex/zone-102-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-520-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-519-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-527-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-538-duct-after-damper",
+ "@id": "urn:ex/vav-514-reheat-coil-air-out",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/connection-to-room-115"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-514-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-514-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-514-air-out"
+ }
]
},
{
- "@id": "urn:ex/vav-538-more-heat-requests",
+ "@id": "urn:ex/vav-533-pipe-hot-water-return-before-valve",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-519-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-507-pipe-hot-water-return-before-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-537-damper-in",
+ "@id": "urn:ex/zone-112-114-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-537-air-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-513-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "@id": "urn:ex/vav-503-reheat-coil-valve",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-513-damper-in"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-513-damper-out"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-513-damper-command"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-513-damper-position"
+ "@id": "urn:ex/vav-503-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-509-reheat-coil-valve-in",
+ "@id": "urn:ex/vav-537-damper-actuator",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/vav-537-damper"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-537-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-505-damper-in",
+ "@id": "urn:ex/room-212",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-connection-to-vavs"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-505-air-in"
+ "@id": "urn:ex/room-212-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-ra-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -35021,7 +34829,7 @@
]
},
{
- "@id": "urn:ex/vav-505-reheat-coil-valve-command",
+ "@id": "urn:ex/office-ahu-oa-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -35037,44 +34845,51 @@
]
},
{
- "@id": "urn:ex/vav-531-reheat-coil-water-in",
+ "@id": "urn:ex/connection-to-room-213",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-531-hot-water-in-connection"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-504-discharge-air-temp-setpoint",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-531-hot-water-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-515-reheat-coil-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/office-ahu-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-535-hot-water-in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -35086,84 +34901,127 @@
]
},
{
- "@id": "urn:ex/vav-511-discharge-air-flow",
+ "@id": "urn:ex/vav-516-reheat-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ "@id": "urn:ex/vav-516-duct-after-damper"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-533-damper-position",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-212-heating-setpoint",
+ "@id": "urn:ex/connection-to-room-103",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-533-reheat-coil-air-out",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/connection-to-room-305"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-533-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-533-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-533-air-out"
}
]
},
{
- "@id": "urn:ex/vav-527-discharge-air-flow-sensor",
+ "@id": "urn:ex/vav-502-discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-527-air-in"
+ "@id": "urn:ex/vav-502-air-in"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-527-discharge-air-flow"
+ "@id": "urn:ex/vav-502-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-520-damper-actuator",
+ "@id": "urn:ex/zone-213-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-520-damper"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/vav-520-damper-command"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/room-214-out",
+ "@id": "urn:ex/vav-535-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-503-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -35171,46 +35029,58 @@
]
},
{
- "@id": "urn:ex/vav-537-reheat-coil-valve-in",
+ "@id": "urn:ex/room-107-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-537-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-106-107"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-517-damper-in",
+ "@id": "urn:ex/vav-505-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-532-reheat-coil-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-532-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-517-air-in"
+ "@id": "urn:ex/vav-532-hot-water-in"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-damper-position",
+ "@id": "urn:ex/vav-513-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -35224,46 +35094,52 @@
]
},
{
- "@id": "urn:ex/vav-510-hot-water-out",
+ "@id": "urn:ex/zone-214-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-510-hot-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-539-heating-pid-output",
+ "@id": "urn:ex/vav-512-reheat-coil",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/vav-512-reheat-coil-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-512-reheat-coil-water-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/vav-518-hot-water-in",
+ "@id": "urn:ex/office-ahu-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-518-hot-water-in-connection"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -35272,236 +35148,255 @@
]
},
{
- "@id": "urn:ex/vav-510-air-in",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/zone-111-temp",
+ "@id": "urn:ex/vav-531-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-531-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-531-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-536-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-519-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-539-damper",
+ "@id": "urn:ex/vav-504-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-539-damper-in"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-in"
},
{
- "@id": "urn:ex/vav-539-damper-out"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-539-damper-command"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-command"
},
{
- "@id": "urn:ex/vav-539-damper-position"
+ "@id": "urn:ex/vav-504-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-515-discharge-air-flow-sensor",
+ "@id": "urn:ex/room-303-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-515-air-in"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-515-discharge-air-flow"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/zone-102-heating-setpoint",
+ "@id": "urn:ex/vav-519-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/vav-519-duct-after-damper"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-519-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-519-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/room-211-hvac-domain",
+ "@id": "urn:ex/room-215-out",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-211-in"
- },
- {
- "@id": "urn:ex/room-211-out"
+ "@id": "urn:ex/office-ahu-connection-from-rooms"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-503-damper-position",
+ "@id": "urn:ex/zone-110-occupancy-override",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/zone-203-temp-sensor",
+ "@id": "urn:ex/vav-533-discharge-air-temp-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-203-hvac-domain"
+ "@id": "urn:ex/vav-533-air-out"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-203-temp"
+ "@id": "urn:ex/vav-533-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-517-air-out"
+ "@id": "urn:ex/vav-530-reheat-coil-valve"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-517-discharge-air-temp"
+ "@id": "urn:ex/vav-530-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/vav-509-hot-water-out",
+ "@id": "urn:ex/vav-509-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-hot-water-out-connection"
+ "@id": "urn:ex/connection-to-room-113"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/vav-501-more-heat-requests",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/vav-509-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-509-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-509-air-out"
}
]
},
{
- "@id": "urn:ex/vav-521-discharge-air-flow-sensor",
+ "@id": "urn:ex/zone-101-cooling-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-521-air-in"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-discharge-air-flow"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/office-ahu-oa-in",
+ "@id": "urn:ex/vav-539",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-oa-in-connection"
+ "@id": "urn:ex/vav-539-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-539-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-539-damper"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-539-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-515-pipe-hot-water-return-before-valve",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -35513,80 +35408,101 @@
]
},
{
- "@id": "urn:ex/office-ahu-supply-duct-static-pressure",
+ "@id": "urn:ex/zone-303-304-306-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Supply"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-539-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:ex/vav-539-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-539-damper-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-539-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-539-damper-position"
}
]
},
{
- "@id": "urn:ex/vav-521-damper-out",
+ "@id": "urn:ex/vav-517-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Actuator"
+ ],
+ "http://data.ashrae.org/standard223#actuates": [
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#commandedByProperty": [
+ {
+ "@id": "urn:ex/vav-517-reheat-coil-valve-command"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-302-co2-concentration",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#ofSubstance": [
{
- "@id": "urn:ex/vav-521-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Substance-CO2"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/MoleFraction"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-521-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-521-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/PPM"
}
]
},
{
- "@id": "urn:ex/vav-529-reheat-coil",
+ "@id": "urn:ex/vav-527-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/vav-529-reheat-coil-air-in"
- },
- {
- "@id": "urn:ex/vav-529-reheat-coil-air-out"
- },
- {
- "@id": "urn:ex/vav-529-reheat-coil-water-in"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-529-reheat-coil-water-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-539-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-511-reheat-coil-valve-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -35600,30 +35516,40 @@
]
},
{
- "@id": "urn:ex/vav-531-damper-in",
+ "@id": "urn:ex/room-313-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/room-313-in"
+ },
+ {
+ "@id": "urn:ex/room-313-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-509-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-531-air-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-534-discharge-air-temp-setpoint",
+ "@id": "urn:ex/zone-212-temp",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -35637,198 +35563,201 @@
]
},
{
- "@id": "urn:ex/zone-208-209-occupancy-override",
+ "@id": "urn:ex/vav-519-reheat-coil-valve-in",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-519-pipe-hot-water-return-before-valve"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/zone-207-occupancy-override",
+ "@id": "urn:ex/zone-202-occupancy",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/vav-538-damper-actuator",
+ "@id": "urn:ex/vav-532-reheat-coil-valve-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-538-damper"
+ "@id": "urn:ex/vav-532-reheat-coil-valve"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-538-damper-command"
+ "@id": "urn:ex/vav-532-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/office-ahu-ea-damper-actuator",
+ "@id": "urn:ex/vav-523-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/office-ahu-ea-damper"
+ "@id": "urn:ex/vav-523-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/office-ahu-ea-damper-command"
+ "@id": "urn:ex/vav-523-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-532-duct-after-damper",
+ "@id": "urn:ex/vav-539-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Pipe"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-509-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/room-203-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/room-203-in"
+ },
+ {
+ "@id": "urn:ex/room-203-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-514-hot-water-out-connection",
+ "@id": "urn:ex/vav-538-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-actuator",
+ "@id": "urn:ex/vav-513-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-515-reheat-coil-valve-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-539",
+ "@id": "urn:ex/vav-539-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#SingleDuctTerminal",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
"@id": "urn:ex/vav-539-air-in"
- },
- {
- "@id": "urn:ex/vav-539-air-out"
- },
- {
- "@id": "urn:ex/vav-539-hot-water-in"
- },
- {
- "@id": "urn:ex/vav-539-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:ex/vav-539-damper"
- },
- {
- "@id": "urn:ex/vav-539-reheat-coil"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-539-reheat-coil-valve"
+ "@id": "urn:ex/vav-539-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-506-discharge-air-temp",
+ "@id": "urn:ex/vav-540-damper-position",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasAspect": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-522-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-513-hot-water-out-connection",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-522-air-out"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-530-hot-water-in-connection",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-522-discharge-air-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-527-damper-actuator",
+ "@id": "urn:ex/zone-110-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-527-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-527-damper-command"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-529-duct-after-damper",
+ "@id": "urn:ex/vav-521-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -35840,9 +35769,9 @@
]
},
{
- "@id": "urn:ex/zone-202-window-switch-on-off",
+ "@id": "urn:ex/office-ahu-sa-fan-start-cmd",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -35851,143 +35780,180 @@
]
},
{
- "@id": "urn:ex/vav-519-damper-actuator",
+ "@id": "urn:ex/vav-540-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-519-damper"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-519-damper-command"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-in",
+ "@id": "urn:ex/room-311",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/room-311-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-118-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/office-ahu-ra-flow"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-ra-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-522-air-out",
+ "@id": "urn:ex/zone-112-114-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/connection-to-room-208-209"
+ "@id": "urn:ex/room-112-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-112-114-temp"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-519",
+ "@type": [
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-522-discharge-air-flow"
+ "@id": "urn:ex/vav-519-air-in"
},
{
- "@id": "urn:ex/vav-522-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-519-air-out"
},
{
- "@id": "urn:ex/vav-522-discharge-air-temp"
+ "@id": "urn:ex/vav-519-hot-water-in"
},
{
- "@id": "urn:ex/vav-522-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-519-hot-water-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:ex/vav-519-damper"
+ },
+ {
+ "@id": "urn:ex/vav-519-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-519-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/room-314-in",
+ "@id": "urn:ex/vav-537-damper",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Damper",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-314"
+ "@id": "urn:ex/vav-537-damper-in"
+ },
+ {
+ "@id": "urn:ex/vav-537-damper-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-537-damper-command"
+ },
+ {
+ "@id": "urn:ex/vav-537-damper-position"
}
]
},
{
- "@id": "urn:ex/zone-204-205-occupancy",
+ "@id": "urn:ex/room-206",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/room-206-hvac-domain"
}
]
},
{
- "@id": "urn:ex/room-104-out",
+ "@id": "urn:ex/vav-523",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#SingleDuctTerminal",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#VAVWithReheat"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-523-air-in"
+ },
+ {
+ "@id": "urn:ex/vav-523-air-out"
+ },
+ {
+ "@id": "urn:ex/vav-523-hot-water-in"
+ },
+ {
+ "@id": "urn:ex/vav-523-hot-water-out"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-523-damper"
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil"
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil-valve"
}
]
},
{
- "@id": "urn:ex/zone-215-window-switch-on-off",
+ "@id": "urn:ex/vav-527-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
- ]
- },
- {
- "@id": "urn:ex/office-ahu-connection-from-rooms",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-519-damper-in",
+ "@id": "urn:ex/vav-536-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -36003,28 +35969,55 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-519-air-in"
+ "@id": "urn:ex/vav-536-air-in"
}
]
},
{
- "@id": "urn:ex/zone-101-building-static-pressure-setpoint",
+ "@id": "urn:ex/vav-517-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-203-temp",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ]
+ },
+ {
+ "@id": "urn:ex/zone-314-cooling-setpoint",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-508-damper-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -36040,153 +36033,175 @@
]
},
{
- "@id": "urn:ex/room-106",
+ "@id": "urn:ex/vav-531-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/room-106-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-514-air-out",
+ "@id": "urn:ex/vav-521-reheat-coil-valve-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-115"
+ "@id": "urn:ex/vav-521-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-514-discharge-air-flow"
- },
- {
- "@id": "urn:ex/vav-514-discharge-air-flow-setpoint"
- },
- {
- "@id": "urn:ex/vav-514-discharge-air-temp"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/vav-514-discharge-air-temp-setpoint"
+ "@id": "urn:ex/vav-521-hot-water-out"
}
]
},
{
- "@id": "urn:ex/zone-302-temp-sensor",
+ "@id": "urn:ex/vav-502-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-302-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/zone-302-temp"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-528-damper-actuator",
+ "@id": "urn:ex/vav-512-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-528-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-528-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-514-damper-position",
+ "@id": "urn:ex/room-116-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/room-116-in"
+ },
+ {
+ "@id": "urn:ex/room-116-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-521-colder-supply-air-requests",
+ "@id": "urn:ex/zone-210",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "urn:ex/room-210-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/zone-113-occupancy",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/zone-210-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-210-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-210-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-210-occupancy-override"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "urn:ex/zone-210-temp"
+ },
+ {
+ "@id": "urn:ex/zone-210-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-524-hot-water-out",
+ "@id": "urn:ex/vav-518-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-524-hot-water-out-connection"
+ "@id": "urn:ex/vav-518-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-518-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-536-hot-water-out",
+ "@id": "urn:ex/office-ahu-htg-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-536-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-duct-after-htg-coil"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-516-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-522-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-522-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -36195,161 +36210,187 @@
]
},
{
- "@id": "urn:ex/room-201-in",
+ "@id": "urn:ex/vav-514-hot-water-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-201"
+ "@id": "urn:ex/vav-514-hot-water-in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-water-in",
+ "@id": "urn:ex/vav-538-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-511-hot-water-in-connection"
+ "@id": "urn:ex/vav-538-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-511-hot-water-in"
+ "@id": "urn:ex/vav-538-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-538-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-118-window-switch-on-off",
+ "@id": "urn:ex/vav-536-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-538-air-in",
+ "@id": "urn:ex/vav-507-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-to-vavs"
+ "@id": "urn:ex/vav-507-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-507-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/vav-515-hot-water-out-connection",
+ "@id": "urn:ex/zone-111-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-533-reheat-coil-valve-position",
+ "@id": "urn:ex/vav-518-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-518-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-518-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-105-occupancy-sensor",
+ "@id": "urn:ex/zone-307-308-occupancy-sensor",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/room-105-hvac-domain"
+ "@id": "urn:ex/room-307-hvac-domain"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/zone-105-occupancy"
+ "@id": "urn:ex/zone-307-308-occupancy"
}
]
},
{
- "@id": "urn:ex/zone-116-117-occupancy-override",
+ "@id": "urn:ex/vav-521-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:ex/vav-521-hot-water-out-connection"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-540-damper-command",
+ "@id": "urn:ex/vav-526-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-503-discharge-air-temp-sensor",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-503-air-out"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-503-discharge-air-temp"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-513-hot-water-out-connection",
+ "@id": "urn:ex/vav-517-hot-water-in",
"@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:ex/vav-517-hot-water-in-connection"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -36358,31 +36399,28 @@
]
},
{
- "@id": "urn:ex/vav-513-damper-out",
+ "@id": "urn:ex/vav-528-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/vav-513-duct-after-damper"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-513-colder-supply-air-requests"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/vav-513-cooling-pid-output"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-503-pipe-hot-water-return-before-valve",
+ "@id": "urn:ex/vav-536-hot-water-out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Pipe"
@@ -36394,284 +36432,300 @@
]
},
{
- "@id": "urn:ex/room-201-out",
+ "@id": "urn:ex/zone-213-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/zone-201-heating-setpoint",
+ "@id": "urn:ex/vav-508-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/vav-509-hot-water-in",
+ "@id": "urn:ex/vav-502-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-509-hot-water-in-connection"
+ "@id": "urn:ex/vav-502-hot-water-out-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ]
- },
- {
- "@id": "urn:ex/zone-303-304-306-heating-setpoint",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:ex/vav-502-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-502-damper",
+ "@id": "urn:ex/room-310-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Damper",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-damper-in"
+ "@id": "urn:ex/room-310-in"
},
{
- "@id": "urn:ex/vav-502-damper-out"
+ "@id": "urn:ex/room-310-out"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-damper-command"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-502-damper-position"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-actuator",
+ "@id": "urn:ex/office-ahu-ea-damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#actuates": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve"
+ "@id": "urn:ex/office-ahu-ea-damper"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "urn:ex/vav-528-reheat-coil-valve-command"
+ "@id": "urn:ex/office-ahu-ea-damper-command"
}
]
},
{
- "@id": "urn:ex/vav-516-damper-actuator",
+ "@id": "urn:ex/room-115",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#actuates": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/vav-516-damper"
+ "@id": "urn:ex/room-115-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-515-reheat-coil-valve-command",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-516-damper-command"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-502-air-out",
+ "@id": "urn:ex/zone-313-heating-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/connection-to-room-101"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/room-207-hvac-domain",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-502-discharge-air-flow"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-discharge-air-flow-setpoint"
+ "@id": "urn:ex/room-207-in"
},
{
- "@id": "urn:ex/vav-502-discharge-air-temp"
- },
+ "@id": "urn:ex/room-207-out"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-502-discharge-air-temp-setpoint"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/vav-520-reheat-coil-water-in",
+ "@id": "urn:ex/vav-502-damper-out",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-520-hot-water-in-connection"
+ "@id": "urn:ex/vav-502-duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-520-hot-water-in"
+ "@id": "urn:ex/vav-502-colder-supply-air-requests"
+ },
+ {
+ "@id": "urn:ex/vav-502-cooling-pid-output"
}
]
},
{
- "@id": "urn:ex/zone-104-window-switch-on-off",
+ "@id": "urn:ex/room-116",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "urn:ex/room-116-hvac-domain"
}
]
},
{
- "@id": "urn:ex/vav-540-discharge-air-flow-setpoint",
+ "@id": "urn:ex/vav-540-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/vav-540-air-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:ex/vav-540-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-311",
+ "@id": "urn:ex/zone-102",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Zone",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:ex/room-311-hvac-domain"
+ "@id": "urn:ex/room-102-hvac-domain"
}
- ]
- },
- {
- "@id": "urn:ex/vav-529-reheat-coil-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/vav-529-pipe-hot-water-return-before-valve"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/zone-102-cooling-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-102-heating-setpoint"
+ },
+ {
+ "@id": "urn:ex/zone-102-occupancy"
+ },
+ {
+ "@id": "urn:ex/zone-102-occupancy-override"
+ },
+ {
+ "@id": "urn:ex/zone-102-temp"
+ },
+ {
+ "@id": "urn:ex/zone-102-window-switch-on-off"
}
]
},
{
- "@id": "urn:ex/vav-537-discharge-air-flow",
+ "@id": "urn:ex/room-102-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasAspect": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Discharge"
- }
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:ex/room-102-in"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:ex/room-102-out"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-201-temp-sensor",
+ "@id": "urn:ex/room-209-hvac-domain",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-201-hvac-domain"
+ "@id": "urn:ex/room-209-in"
+ },
+ {
+ "@id": "urn:ex/room-209-out"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:ex/zone-201-temp"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
]
},
{
- "@id": "urn:ex/zone-208-209-occupancy-sensor",
+ "@id": "urn:ex/",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-208-hvac-domain"
- }
+ "http://www.w3.org/2002/07/owl#Ontology"
+ ]
+ },
+ {
+ "@id": "urn:ex/room-215",
+ "@type": [
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/zone-208-209-occupancy"
+ "@id": "urn:ex/room-215-hvac-domain"
}
]
},
{
- "@id": "urn:ex/connection-to-room-311",
+ "@id": "urn:ex/vav-522-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -36683,20 +36737,25 @@
]
},
{
- "@id": "urn:ex/vav-525-more-heat-requests",
+ "@id": "urn:ex/vav-529-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-526-damper-position",
+ "@id": "urn:ex/vav-540-damper-command",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -36710,85 +36769,107 @@
]
},
{
- "@id": "urn:ex/room-208-hvac-domain",
+ "@id": "urn:ex/vav-528-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-208-in"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/room-208-out"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-520-duct-after-damper",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-511-damper-position",
+ "@id": "urn:ex/vav-530-reheat-coil-valve-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-530-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-530-hot-water-out"
}
]
},
{
- "@id": "urn:ex/vav-527-reheat-coil-water-out",
+ "@id": "urn:ex/vav-506-reheat-coil-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-527-pipe-hot-water-return-before-valve"
+ "@id": "urn:ex/connection-to-room-106-107"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:ex/vav-506-heating-pid-output"
+ },
+ {
+ "@id": "urn:ex/vav-506-more-heat-requests"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:ex/vav-506-air-out"
}
]
},
{
- "@id": "urn:ex/vav-538-reheat-coil-water-in",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-538-hot-water-in-connection"
+ "@id": "urn:ex/vav-539-pipe-hot-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Water"
}
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-538-hot-water-in"
- }
]
},
{
- "@id": "urn:ex/room-301-out",
+ "@id": "urn:ex/room-105-in",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/connection-to-room-105"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -36798,159 +36879,148 @@
]
},
{
- "@id": "urn:ex/office-ahu-htg-coil-valve-command",
+ "@id": "urn:ex/zone-118-occupancy",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
}
]
},
{
- "@id": "urn:ex/office-ahu-ra-fan-in",
+ "@id": "urn:ex/vav-525-discharge-air-temp",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasAspect": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:ex/office-ahu-ra-in"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/room-305-out",
+ "@id": "urn:ex/vav-534-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-534-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-534-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-211-cooling-setpoint",
+ "@id": "urn:ex/vav-504-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-530-reheat-coil-air-out",
+ "@id": "urn:ex/vav-511-discharge-air-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-303-304-306"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-530-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-530-more-heat-requests"
+ "@id": "urn:ex/vav-511-air-out"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-530-air-out"
+ "@id": "urn:ex/vav-511-discharge-air-temp"
}
]
},
{
- "@id": "urn:ex/room-102-out",
+ "@id": "urn:ex/vav-538-heating-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-118",
+ "@id": "urn:ex/vav-508-colder-supply-air-requests",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:ex/room-118-hvac-domain"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-502-reheat-coil-valve-out",
+ "@id": "urn:ex/vav-513-reheat-coil-valve",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-502-hot-water-out-connection"
+ "@id": "urn:ex/vav-513-reheat-coil-valve-in"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-valve-out"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Water-HotWater"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-502-hot-water-out"
+ "@id": "urn:ex/vav-513-reheat-coil-valve-command"
+ },
+ {
+ "@id": "urn:ex/vav-513-reheat-coil-valve-position"
}
]
},
{
- "@id": "urn:ex/vav-517-air-out",
+ "@id": "urn:ex/vav-529-air-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/connection-to-room-203"
+ "@id": "urn:ex/connection-to-room-303-304-306"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -36960,37 +37030,21 @@
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:ex/vav-517-discharge-air-flow"
+ "@id": "urn:ex/vav-529-discharge-air-flow"
},
{
- "@id": "urn:ex/vav-517-discharge-air-flow-setpoint"
+ "@id": "urn:ex/vav-529-discharge-air-flow-setpoint"
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp"
+ "@id": "urn:ex/vav-529-discharge-air-temp"
},
{
- "@id": "urn:ex/vav-517-discharge-air-temp-setpoint"
- }
- ]
- },
- {
- "@id": "urn:ex/office-ahu-clg-coil-water-out",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:ex/vav-529-discharge-air-temp-setpoint"
}
]
},
{
- "@id": "urn:ex/vav-523-damper-command",
+ "@id": "urn:ex/vav-539-reheat-coil-valve-command",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -37006,76 +37060,35 @@
]
},
{
- "@id": "urn:ex/room-303",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:ex/room-303-hvac-domain"
- }
- ]
- },
- {
- "@id": "urn:ex/vav-529-reheat-coil-air-out",
+ "@id": "urn:ex/zone-201-occupancy-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-303-304-306"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-529-heating-pid-output"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-529-more-heat-requests"
+ "@id": "urn:ex/room-201-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:ex/vav-529-air-out"
+ "@id": "urn:ex/zone-201-occupancy"
}
]
},
{
- "@id": "urn:ex/vav-507-reheat-coil-air-out",
+ "@id": "urn:ex/vav-504-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/connection-to-room-110"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/vav-507-heating-pid-output"
- },
- {
- "@id": "urn:ex/vav-507-more-heat-requests"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-507-air-out"
- }
]
},
{
- "@id": "urn:ex/vav-516-duct-after-damper",
+ "@id": "urn:ex/vav-519-duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
@@ -37087,98 +37100,89 @@
]
},
{
- "@id": "urn:ex/zone-303-304-306-temp",
+ "@id": "urn:ex/vav-502-discharge-air-flow-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
- "@id": "urn:ex/vav-511-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-516-reheat-coil-valve-actuator",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Actuator"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#actuates": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-516-reheat-coil-valve"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#commandedByProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:ex/vav-516-reheat-coil-valve-command"
}
]
},
{
- "@id": "urn:ex/zone-101-temp-sensor",
+ "@id": "urn:ex/room-311-in",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/room-101-hvac-domain"
+ "@id": "urn:ex/connection-to-room-311"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/zone-101-temp"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-518-reheat-coil-water-in",
+ "@id": "urn:ex/room-106-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-518-hot-water-in-connection"
+ "@id": "urn:ex/connection-to-room-106-107"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:ex/vav-518-hot-water-in"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-505-damper-actuator",
+ "@id": "urn:ex/vav-534-duct-after-damper",
"@type": [
- "http://data.ashrae.org/standard223#Actuator"
- ],
- "http://data.ashrae.org/standard223#actuates": [
- {
- "@id": "urn:ex/vav-505-damper"
- }
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#commandedByProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/vav-505-damper-command"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/vav-523-hot-water-out",
+ "@id": "urn:ex/office-ahu-clg-coil-water-out",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-523-hot-water-out-connection"
+ "@id": "urn:ex/office-ahu-pipe-chilled-water-return-before-valve"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -37188,105 +37192,118 @@
]
},
{
- "@id": "urn:ex/vav-501-reheat-coil-air-in",
+ "@id": "urn:ex/zone-311-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/vav-501-duct-after-damper"
+ "@id": "urn:ex/room-311-hvac-domain"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/zone-311-temp"
}
]
},
{
- "@id": "urn:ex/vav-536-colder-supply-air-requests",
+ "@id": "urn:ex/vav-539-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-523-reheat-coil-valve-command",
+ "@id": "urn:ex/vav-509-hot-water-out",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:ex/vav-509-hot-water-out-connection"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
]
},
{
- "@id": "urn:ex/vav-528-heating-pid-output",
+ "@id": "urn:ex/zone-211-temp",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
]
},
{
- "@id": "urn:ex/vav-524-cooling-pid-output",
+ "@id": "urn:ex/zone-302-temp-sensor",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ "@id": "urn:ex/room-302-hvac-domain"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/UNITLESS"
+ "@id": "urn:ex/zone-302-temp"
}
]
},
{
- "@id": "urn:ex/vav-535-hot-water-out",
+ "@id": "urn:ex/vav-512-reheat-coil-valve-position",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/vav-535-hot-water-out-connection"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/room-203-out",
+ "@id": "urn:ex/vav-517-hot-water-in-connection",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/connection-to-room-105",
+ "@type": [
+ "http://data.ashrae.org/standard223#Connection",
+ "http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -37295,152 +37312,146 @@
]
},
{
- "@id": "urn:ex/zone-109",
+ "@id": "urn:ex/vav-538-discharge-air-temp-setpoint",
"@type": [
- "http://data.ashrae.org/standard223#Zone",
- "http://data.ashrae.org/standard223/1.0/extensions/g36#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:ex/room-109-hvac-domain"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-523-reheat-coil",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil",
+ "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:ex/zone-109-cooling-setpoint"
- },
- {
- "@id": "urn:ex/zone-109-heating-setpoint"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/zone-109-occupancy"
+ "@id": "urn:ex/vav-523-reheat-coil-air-in"
},
{
- "@id": "urn:ex/zone-109-occupancy-override"
+ "@id": "urn:ex/vav-523-reheat-coil-air-out"
},
{
- "@id": "urn:ex/zone-109-temp"
+ "@id": "urn:ex/vav-523-reheat-coil-water-in"
},
{
- "@id": "urn:ex/zone-109-window-switch-on-off"
+ "@id": "urn:ex/vav-523-reheat-coil-water-out"
}
- ]
- },
- {
- "@id": "urn:ex/vav-535-duct-after-damper",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
]
},
{
- "@id": "urn:ex/zone-313-occupancy",
+ "@id": "urn:ex/zone-302-occupancy-override",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Occupancy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
]
},
{
- "@id": "urn:ex/vav-529-colder-supply-air-requests",
+ "@id": "urn:ex/vav-535-damper-position",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:ex/vav-520-hot-water-out-connection",
- "@type": [
- "http://data.ashrae.org/standard223#Connection",
- "http://data.ashrae.org/standard223#Pipe"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
- "@id": "urn:ex/vav-514-hot-water-in",
+ "@id": "urn:ex/vav-507-air-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:ex/vav-514-hot-water-in-connection"
+ "@id": "urn:ex/office-ahu-connection-to-vavs"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
- "@id": "urn:ex/room-112-out",
+ "@id": "urn:ex/vav-538-discharge-air-flow-sensor",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:ex/office-ahu-connection-from-rooms"
+ "@id": "urn:ex/vav-538-air-in"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:ex/vav-538-discharge-air-flow"
}
]
},
{
- "@id": "urn:ex/zone-211-window-switch-on-off",
+ "@id": "urn:ex/vav-507-cooling-pid-output",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff"
+ "@id": "http://qudt.org/vocab/quantitykind/Dimensionless"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/UNITLESS"
}
]
},
{
- "@id": "urn:ex/room-209-hvac-domain",
+ "@id": "urn:ex/room-301",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:ex/room-209-in"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:ex/room-209-out"
+ "@id": "urn:ex/room-301-hvac-domain"
}
+ ]
+ },
+ {
+ "@id": "urn:ex/vav-513-colder-supply-air-requests",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-HVACOperatingMode"
}
]
},
{
- "@id": "urn:ex/vav-522-air-in",
+ "@id": "urn:ex/vav-533-damper-in",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -37453,37 +37464,26 @@
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "urn:ex/zone-303-304-306-temp-sensor",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:ex/room-303-hvac-domain"
- }
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:ex/zone-303-304-306-temp"
+ "@id": "urn:ex/vav-533-air-in"
}
]
},
{
- "@id": "urn:ex/zone-115-heating-setpoint",
+ "@id": "urn:ex/office-ahu-clg-coil-air-in",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:ex/office-ahu-duct-after-htg-coil"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
}
diff --git a/models/nrel-example.jsonld b/models/nrel-example.jsonld
index a2142e2e..a0389f65 100644
--- a/models/nrel-example.jsonld
+++ b/models/nrel-example.jsonld
@@ -1,37 +1,29 @@
[
{
- "@id": "urn:nrel_example/nrel00000557",
+ "@id": "urn:nrel_example/nrel00000990",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000557"
+ "@value": "nrel00000990"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000911",
+ "@id": "urn:nrel_example/nrel00000745",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000869"
- },
- {
- "@id": "urn:nrel_example/nrel00001183"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -40,101 +32,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000911"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000164",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000164"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000798",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000798"
+ "@value": "nrel00000745"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000233",
+ "@id": "urn:nrel_example/nrel00001090",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000226"
- },
- {
- "@id": "urn:nrel_example/nrel00000568"
- },
- {
- "@id": "urn:nrel_example/nrel00001291"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000512"
- },
- {
- "@id": "urn:nrel_example/nrel00001208"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000115"
- },
- {
- "@id": "urn:nrel_example/nrel00000348"
- },
- {
- "@id": "urn:nrel_example/nrel00000451"
- },
- {
- "@id": "urn:nrel_example/nrel00001002"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001212"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000233"
+ "@value": "nrel00001090"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001251",
+ "@id": "urn:nrel_example/nrel00000489",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -143,44 +69,46 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001251"
+ "@value": "nrel00000489"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000695",
+ "@id": "urn:nrel_example/nrel00000775",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000695"
+ "@value": "nrel00000775"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000874",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Class",
+ "http://data.ashrae.org/standard223#EnumerationKind-Override",
+ "http://www.w3.org/ns/shacl#NodeShape"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@value": "EnumerationKind Override"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
{
- "@value": "nrel00000874"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000814",
+ "@id": "urn:nrel_example/nrel00000467",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -191,243 +119,240 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000814"
+ "@value": "nrel00000467"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000994",
+ "@id": "urn:nrel_example/nrel00001162",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000069"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000482"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000111"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001319"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000994"
+ "@value": "nrel00001162"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000340",
+ "@id": "urn:nrel_example/nrel00000448",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000051"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000202"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000340"
+ "@value": "nrel00000448"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001059",
+ "@id": "urn:nrel_example/nrel00000412",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001059"
+ "@value": "nrel00000412"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000113",
+ "@id": "urn:nrel_example/nrel00000750",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000113"
+ "@value": "nrel00000750"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000086",
+ "@id": "urn:nrel_example/nrel00001252",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000086"
+ "@value": "nrel00001252"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000118",
+ "@id": "urn:nrel_example/nrel00000084",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000133"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000593"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000772"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000151"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000167"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000432"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000991"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000978"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001235"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000118"
+ "@value": "nrel00000084"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000949",
+ "@id": "urn:nrel_example/nrel00000928",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000949"
+ "@value": "nrel00000928"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000599",
+ "@id": "urn:nrel_example/nrel00001178",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000599"
+ "@value": "nrel00001178"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001040",
+ "@id": "urn:nrel_example/nrel00001142",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000266"
+ },
{
- "@value": "nrel00001040"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000734",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "urn:nrel_example/nrel00000472"
+ },
{
- "@id": "urn:nrel_example/nrel00000075"
+ "@id": "urn:nrel_example/nrel00000934"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000740"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000104"
+ },
{
- "@value": "nrel00000734"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000661",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00000620"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00001141"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001241"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000256"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000260"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000661"
+ "@value": "nrel00001142"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000258",
+ "@id": "urn:nrel_example/nrel00001164",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000459"
- },
- {
- "@id": "urn:nrel_example/nrel00001007"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -436,54 +361,44 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000258"
+ "@value": "nrel00001164"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000202",
+ "@id": "urn:nrel_example/nrel00001060",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000202"
+ "@value": "nrel00001060"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000843",
+ "@id": "urn:nrel_example/nrel00000339",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000843"
+ "@value": "nrel00000339"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000380",
+ "@id": "urn:nrel_example/nrel00000082",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -494,14 +409,22 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000380"
+ "@value": "nrel00000082"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000658",
+ "@id": "urn:nrel_example/nrel00000783",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000970"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000984"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -510,65 +433,65 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000658"
+ "@value": "nrel00000783"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001262",
+ "@id": "urn:nrel_example/nrel00000326",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001262"
+ "@value": "nrel00000326"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000225",
+ "@id": "urn:nrel_example/nrel00000242",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000225"
+ "@value": "nrel00000242"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001088",
+ "@id": "urn:nrel_example/nrel00000215",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001088"
+ "@value": "nrel00000215"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001082",
+ "@id": "urn:nrel_example/nrel00001001",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -584,229 +507,257 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001082"
+ "@value": "nrel00001001"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000767",
+ "@id": "urn:nrel_example/nrel00000816",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001125"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000500"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000002"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000767"
+ "@value": "nrel00000816"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000758",
+ "@id": "urn:nrel_example/nrel00000252",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@value": "nrel00000252"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000190",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000758"
+ "@value": "nrel00000190"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000042",
+ "@id": "urn:nrel_example/nrel00001216",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000042"
+ "@value": "nrel00001216"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001227",
+ "@id": "urn:nrel_example/nrel00001098",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001227"
+ "@value": "nrel00001098"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001092",
+ "@id": "urn:nrel_example/nrel00000429",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Filter"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000539"
+ "@id": "urn:nrel_example/nrel00000158"
},
{
- "@id": "urn:nrel_example/nrel00000763"
+ "@id": "urn:nrel_example/nrel00000940"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000436"
- },
- {
- "@id": "urn:nrel_example/nrel00001225"
+ "@id": "urn:nrel_example/nrel00000250"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001092"
+ "@value": "nrel00000429"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000542",
+ "@id": "urn:nrel_example/nrel00000891",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000158"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000577"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000542"
+ "@value": "nrel00000891"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000948",
+ "@id": "urn:nrel_example/nrel00000833",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00000948"
+ "@id": "urn:nrel_example/nrel00000074"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000624",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00001027"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000206"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000624"
+ "@value": "nrel00000833"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000997",
+ "@id": "urn:nrel_example/nrel00000733",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000949"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001057"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000357"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001017"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000997"
+ "@value": "nrel00000733"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001234",
+ "@id": "urn:nrel_example/nrel00000197",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001234"
+ "@value": "nrel00000197"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000995",
+ "@id": "urn:nrel_example/nrel00000825",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000131"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001259"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000995"
+ "@value": "nrel00000825"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001201",
+ "@id": "urn:nrel_example/nrel00000997",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -815,440 +766,442 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001201"
+ "@value": "nrel00000997"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001037",
+ "@id": "urn:nrel_example/nrel00001024",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000722"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000820"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000208"
+ },
{
- "@value": "nrel00001037"
+ "@id": "urn:nrel_example/nrel00000947"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000979",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000979"
+ "@value": "nrel00001024"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001035",
+ "@id": "urn:nrel_example/nrel00000308",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001035"
+ "@value": "nrel00000308"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000956",
+ "@id": "urn:nrel_example/nrel00001331",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000956"
+ "@value": "nrel00001331"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000211",
+ "@id": "urn:nrel_example/nrel00000052",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000211"
+ "@value": "nrel00000052"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000796",
+ "@id": "urn:nrel_example/nrel00000705",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000796"
+ "@value": "nrel00000705"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000669",
+ "@id": "urn:nrel_example/nrel00000493",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000587"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000160"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000844"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000669"
+ "@value": "nrel00000493"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000081",
+ "@id": "urn:nrel_example/nrel00000105",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000081"
+ "@value": "nrel00000105"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000169",
+ "@id": "urn:nrel_example/nrel00001210",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000169"
+ "@value": "nrel00001210"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000405",
+ "@id": "urn:nrel_example/nrel00001072",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000405"
+ "@value": "nrel00001072"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000245",
+ "@id": "urn:nrel_example/nrel00001118",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000245"
+ "@value": "nrel00001118"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000021",
+ "@id": "urn:nrel_example/nrel00000909",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000339"
+ "@id": "urn:nrel_example/nrel00000658"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001165"
+ "@id": "urn:nrel_example/nrel00000282"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000637"
+ "@id": "urn:nrel_example/nrel00000091"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000021"
+ "@value": "nrel00000909"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000434",
+ "@id": "urn:nrel_example/nrel00001271",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000434"
+ "@value": "nrel00001271"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001100",
+ "@id": "urn:nrel_example/nrel00000938",
"@type": [
- "http://data.ashrae.org/standard223#HeatExchanger"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000449"
+ "@id": "urn:nrel_example/nrel00000073"
},
{
- "@id": "urn:nrel_example/nrel00001258"
+ "@id": "urn:nrel_example/nrel00000324"
},
{
- "@id": "urn:nrel_example/nrel00001263"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000261"
+ "@id": "urn:nrel_example/nrel00000510"
},
{
- "@id": "urn:nrel_example/nrel00000554"
+ "@id": "urn:nrel_example/nrel00001223"
},
{
- "@id": "urn:nrel_example/nrel00000577"
+ "@id": "urn:nrel_example/nrel00001232"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000742"
},
{
- "@id": "urn:nrel_example/nrel00001180"
+ "@id": "urn:nrel_example/nrel00000961"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000687"
+ "@id": "urn:nrel_example/nrel00000064"
},
{
- "@id": "urn:nrel_example/nrel00000885"
+ "@id": "urn:nrel_example/nrel00000332"
},
{
- "@id": "urn:nrel_example/nrel00001179"
+ "@id": "urn:nrel_example/nrel00000475"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
+ "@value": "nrel00000938"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000314",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001100"
+ "@value": "nrel00000314"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000008",
+ "@id": "urn:nrel_example/nrel00000163",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000008"
+ "@value": "nrel00000163"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000683",
+ "@id": "urn:nrel_example/nrel00001186",
"@type": [
- "http://data.ashrae.org/standard223#HeatExchanger"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000083"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000344"
+ "@id": "urn:nrel_example/nrel00000074"
},
{
- "@id": "urn:nrel_example/nrel00000546"
+ "@id": "urn:nrel_example/nrel00001208"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000183"
- },
- {
- "@id": "urn:nrel_example/nrel00000189"
- },
- {
- "@id": "urn:nrel_example/nrel00000271"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000923"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000067"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000163"
- },
+ "@value": "nrel00001186"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000085",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001094"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000683"
+ "@value": "nrel00000085"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000401",
+ "@id": "urn:nrel_example/nrel00001170",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000401"
+ "@value": "nrel00001170"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000503",
+ "@id": "urn:nrel_example/nrel00000581",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000649"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000223"
+ },
{
- "@id": "urn:nrel_example/nrel00000553"
+ "@id": "urn:nrel_example/nrel00000320"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001178"
+ "@id": "urn:nrel_example/nrel00000403"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000850"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000503"
+ "@value": "nrel00000581"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000730",
+ "@id": "urn:nrel_example/nrel00000978",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000730"
+ "@value": "nrel00000978"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001228",
+ "@id": "urn:nrel_example/nrel00000200",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -1257,216 +1210,181 @@
],
"http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:nrel_example/nrel00000227"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001228"
+ "@value": "nrel00000200"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000280",
+ "@id": "urn:nrel_example/nrel00000015",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000003"
- },
- {
- "@id": "urn:nrel_example/nrel00000055"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000848"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000278"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001157"
+ "@value": "nrel00000015"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000312",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000988"
- },
- {
- "@id": "urn:nrel_example/nrel00001152"
- },
- {
- "@id": "urn:nrel_example/nrel00001204"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001244"
+ "@id": "urn:nrel_example/nrel00000869"
},
{
- "@id": "urn:nrel_example/nrel00001282"
+ "@id": "urn:nrel_example/nrel00001228"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00000047"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00000196"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000280"
+ "@value": "nrel00000312"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000120",
+ "@id": "urn:nrel_example/nrel00000942",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000120"
+ "@value": "nrel00000942"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000744",
+ "@id": "urn:nrel_example/nrel00000724",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000744"
+ "@value": "nrel00000724"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001308",
+ "@id": "urn:nrel_example/nrel00001185",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000291"
+ "@id": "urn:nrel_example/nrel00000414"
},
{
- "@id": "urn:nrel_example/nrel00000496"
+ "@id": "urn:nrel_example/nrel00000533"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000667"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000755"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001329"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000970"
+ "@id": "urn:nrel_example/nrel00000207"
},
{
- "@id": "urn:nrel_example/nrel00001207"
+ "@id": "urn:nrel_example/nrel00000864"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000283"
- },
- {
- "@id": "urn:nrel_example/nrel00000651"
- },
- {
- "@id": "urn:nrel_example/nrel00000661"
- },
- {
- "@id": "urn:nrel_example/nrel00000674"
+ "@id": "urn:nrel_example/nrel00000443"
},
{
- "@id": "urn:nrel_example/nrel00000811"
+ "@id": "urn:nrel_example/nrel00000709"
},
{
- "@id": "urn:nrel_example/nrel00000963"
- },
+ "@id": "urn:nrel_example/nrel00001163"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001016"
- },
- {
- "@id": "urn:nrel_example/nrel00001132"
- },
- {
- "@id": "urn:nrel_example/nrel00001272"
- },
- {
- "@id": "urn:nrel_example/nrel00001273"
- },
- {
- "@id": "urn:nrel_example/nrel00001331"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001308"
+ "@value": "nrel00001185"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000547",
+ "@id": "urn:nrel_example/nrel00000803",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000547"
+ "@value": "nrel00000803"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000088",
+ "@id": "urn:nrel_example/nrel00000342",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000986"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "urn:nrel_example/nrel00000967"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001221"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000088"
+ "@value": "nrel00000342"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000585",
+ "@id": "urn:nrel_example/nrel00000623",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -1482,143 +1400,150 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000585"
+ "@value": "nrel00000623"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000313",
+ "@id": "urn:nrel_example/nrel00001292",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000296"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000428"
+ "@id": "urn:nrel_example/nrel00001300"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000066"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001269"
+ "@id": "urn:nrel_example/nrel00000147"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000313"
+ "@value": "nrel00001292"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000596",
+ "@id": "urn:nrel_example/nrel00000553",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000649"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000596"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000532",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000555"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000930"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000532"
+ "@value": "nrel00000553"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000451",
+ "@id": "urn:nrel_example/nrel00001115",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000014"
+ },
{
- "@value": "nrel00000451"
+ "@id": "urn:nrel_example/nrel00000237"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001153",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000102"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000108"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000327"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000338"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000453"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000633"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000732"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001118"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001148"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001206"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001153"
+ "@value": "nrel00001115"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000863",
+ "@id": "urn:nrel_example/nrel00000086",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000863"
+ "@value": "nrel00000086"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000282",
+ "@id": "urn:nrel_example/nrel00000614",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000966"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000091"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000113"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000282"
+ "@value": "nrel00000614"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000922",
+ "@id": "urn:nrel_example/nrel00000108",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -1629,198 +1554,230 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000922"
+ "@value": "nrel00000108"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001027",
+ "@id": "urn:nrel_example/nrel00000103",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000122"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000206"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000537"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001027"
+ "@value": "nrel00000103"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000092",
+ "@id": "urn:nrel_example/nrel00000371",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000017"
+ "@id": "urn:nrel_example/nrel00000723"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001275"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000275"
+ "@id": "urn:nrel_example/nrel00000033"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000136"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000239"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000385"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000560"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000584"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000928"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001150"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001151"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001171"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000092"
+ "@value": "nrel00000371"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000272",
+ "@id": "urn:nrel_example/nrel00001239",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000272"
+ "@value": "nrel00001239"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001055",
+ "@id": "urn:nrel_example/nrel00000885",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001055"
+ "@value": "nrel00000885"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001065",
+ "@id": "urn:nrel_example/nrel00001203",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001065"
+ "@value": "nrel00001203"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000063",
+ "@id": "urn:nrel_example/nrel00000781",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000063"
+ "@value": "nrel00000781"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000571",
+ "@id": "urn:nrel_example/nrel00000239",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000571"
+ "@value": "nrel00000239"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001328",
+ "@id": "urn:nrel_example/nrel00001288",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001328"
+ "@value": "nrel00001288"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000065",
+ "@id": "urn:nrel_example/nrel00000072",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000065"
+ "@value": "nrel00000072"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000768",
+ "@id": "urn:nrel_example/nrel00001143",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001047"
+ "@id": "urn:nrel_example/nrel00000512"
},
{
- "@id": "urn:nrel_example/nrel00001068"
+ "@id": "urn:nrel_example/nrel00001193"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -1830,211 +1787,207 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000768"
+ "@value": "nrel00001143"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000697",
+ "@id": "urn:nrel_example/nrel00000967",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000697"
+ "@value": "nrel00000967"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000568",
+ "@id": "urn:nrel_example/nrel00001305",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000898"
+ "@id": "urn:nrel_example/nrel00000399"
},
{
- "@id": "urn:nrel_example/nrel00001051"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000438"
+ },
{
- "@id": "urn:nrel_example/nrel00000197"
+ "@id": "urn:nrel_example/nrel00000603"
},
{
- "@id": "urn:nrel_example/nrel00000292"
+ "@id": "urn:nrel_example/nrel00000640"
},
{
- "@id": "urn:nrel_example/nrel00000402"
+ "@id": "urn:nrel_example/nrel00000775"
},
{
- "@id": "urn:nrel_example/nrel00000636"
+ "@id": "urn:nrel_example/nrel00000806"
},
{
- "@id": "urn:nrel_example/nrel00000697"
+ "@id": "urn:nrel_example/nrel00000924"
},
{
- "@id": "urn:nrel_example/nrel00000832"
+ "@id": "urn:nrel_example/nrel00000942"
},
{
- "@id": "urn:nrel_example/nrel00000945"
+ "@id": "urn:nrel_example/nrel00000947"
},
{
- "@id": "urn:nrel_example/nrel00000981"
+ "@id": "urn:nrel_example/nrel00001007"
},
{
- "@id": "urn:nrel_example/nrel00001058"
+ "@id": "urn:nrel_example/nrel00001068"
},
{
- "@id": "urn:nrel_example/nrel00001106"
+ "@id": "urn:nrel_example/nrel00001080"
},
{
- "@id": "urn:nrel_example/nrel00001201"
+ "@id": "urn:nrel_example/nrel00001193"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000568"
+ "@value": "nrel00001305"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000871",
+ "@id": "urn:nrel_example/nrel00000719",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000871"
+ "@value": "nrel00000719"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000153",
+ "@id": "urn:nrel_example/nrel00000772",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000167"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000978"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000153"
+ "@value": "nrel00000772"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001076",
+ "@id": "urn:nrel_example/nrel00000721",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001076"
+ "@value": "nrel00000721"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000112",
+ "@id": "urn:nrel_example/nrel00001229",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000407"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000621"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000316"
- },
- {
- "@id": "urn:nrel_example/nrel00000455"
- },
- {
- "@id": "urn:nrel_example/nrel00000506"
- },
- {
- "@id": "urn:nrel_example/nrel00000536"
- },
- {
- "@id": "urn:nrel_example/nrel00000583"
- },
- {
- "@id": "urn:nrel_example/nrel00000666"
- },
- {
- "@id": "urn:nrel_example/nrel00000721"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000764"
- },
+ "@value": "nrel00001229"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000289",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000851"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001103"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000112"
+ "@value": "nrel00000289"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000257",
+ "@id": "urn:nrel_example/nrel00000977",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000257"
+ "@value": "nrel00000977"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000172",
+ "@id": "urn:nrel_example/nrel00000691",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000351"
- },
- {
- "@id": "urn:nrel_example/nrel00001180"
+ "@id": "urn:nrel_example/nrel00000535"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -2044,12 +1997,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000172"
+ "@value": "nrel00000691"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001239",
+ "@id": "urn:nrel_example/nrel00000404",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -2065,125 +2018,101 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001239"
+ "@value": "nrel00000404"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000506",
+ "@id": "urn:nrel_example/nrel00000005",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000506"
+ "@value": "nrel00000005"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001056",
+ "@id": "urn:nrel_example/nrel00000832",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001265"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001056"
+ "@value": "nrel00000832"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000361",
+ "@id": "urn:nrel_example/nrel00000515",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000313"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000870"
+ "@id": "urn:nrel_example/nrel00000745"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000030"
- },
- {
- "@id": "urn:nrel_example/nrel00000704"
- },
- {
- "@id": "urn:nrel_example/nrel00001034"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001264"
+ "@id": "urn:nrel_example/nrel00000160"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000325"
- },
- {
- "@id": "urn:nrel_example/nrel00000599"
- },
- {
- "@id": "urn:nrel_example/nrel00000719"
- },
- {
- "@id": "urn:nrel_example/nrel00000773"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001313"
+ "@id": "urn:nrel_example/nrel00001286"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000361"
+ "@value": "nrel00000515"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001181",
+ "@id": "urn:nrel_example/nrel00000369",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000737"
+ "@id": "urn:nrel_example/nrel00000441"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000915"
+ "@id": "urn:nrel_example/nrel00000758"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001181"
+ "@value": "nrel00000369"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000910",
+ "@id": "urn:nrel_example/nrel00001017",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -2194,128 +2123,167 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000910"
+ "@value": "nrel00001017"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000565",
+ "@id": "urn:nrel_example/nrel00000998",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000465"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000786"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000565"
+ "@value": "nrel00000998"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000592",
+ "@id": "urn:nrel_example/nrel00000814",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000592"
+ "@value": "nrel00000814"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000897",
+ "@id": "urn:nrel_example/nrel00000356",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000897"
+ "@value": "nrel00000356"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000414",
+ "@id": "urn:nrel_example/nrel00000291",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000207"
+ "@id": "urn:nrel_example/nrel00000169"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001009"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001163"
+ "@id": "urn:nrel_example/nrel00000027"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000837"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000414"
+ "@value": "nrel00000291"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000229",
+ "@id": "urn:nrel_example/nrel00001199",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000096"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001032"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000056"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000242"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000277"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000289"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000452"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000559"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000929"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001028"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001066"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001224"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000229"
+ "@value": "nrel00001199"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000978",
+ "@id": "urn:nrel_example/nrel00001055",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000978"
+ "@value": "nrel00001055"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000802",
+ "@id": "urn:nrel_example/nrel00000898",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -2326,38 +2294,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000802"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000367",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000219"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000464"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000956"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000367"
+ "@value": "nrel00000898"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001023",
+ "@id": "urn:nrel_example/nrel00001009",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -2368,277 +2310,296 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001023"
+ "@value": "nrel00001009"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000569",
+ "@id": "urn:nrel_example/nrel00000048",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000569"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001209",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001209"
+ "@value": "nrel00000048"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000663",
+ "@id": "urn:nrel_example/nrel00000079",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000663"
+ "@value": "nrel00000079"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000711",
+ "@id": "urn:nrel_example/nrel00000848",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000581"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000754"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000146"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000570"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001013"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001323"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000511"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000727"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000774"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001184"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001287"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000711"
+ "@value": "nrel00000848"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000403",
+ "@id": "urn:nrel_example/nrel00000608",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001265"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000809"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000403"
+ "@value": "nrel00000608"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000114",
+ "@id": "urn:nrel_example/nrel00001005",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000600"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000477"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000594"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000114"
+ "@value": "nrel00001005"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000167",
+ "@id": "urn:nrel_example/nrel00000694",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000167"
+ "@value": "nrel00000694"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001197",
+ "@id": "urn:nrel_example/nrel00001232",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000466"
+ "@id": "urn:nrel_example/nrel00000309"
},
{
- "@id": "urn:nrel_example/nrel00000590"
+ "@id": "urn:nrel_example/nrel00000602"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001303"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000000"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000032"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000465"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001284"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000499"
+ "@id": "urn:nrel_example/nrel00000358"
},
{
- "@id": "urn:nrel_example/nrel00001306"
+ "@id": "urn:nrel_example/nrel00001220"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001197"
+ "@value": "nrel00001232"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001047",
+ "@id": "urn:nrel_example/nrel00000482",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001047"
+ "@value": "nrel00000482"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001223",
+ "@id": "urn:nrel_example/nrel00000480",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000786"
+ "@id": "urn:nrel_example/nrel00000220"
},
{
- "@id": "urn:nrel_example/nrel00001149"
+ "@id": "urn:nrel_example/nrel00000420"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000363"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000489"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001223"
+ "@value": "nrel00000480"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000496",
+ "@id": "urn:nrel_example/nrel00001034",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000970"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001272"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000496"
+ "@value": "nrel00001034"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000622",
+ "@id": "urn:nrel_example/nrel00001188",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000622"
+ "@value": "nrel00001188"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000692",
+ "@id": "urn:nrel_example/nrel00000434",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000692"
+ "@value": "nrel00000434"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001097",
+ "@id": "urn:nrel_example/nrel00001026",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -2647,103 +2608,86 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001097"
+ "@value": "nrel00001026"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001267",
+ "@id": "urn:nrel_example/nrel00001172",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000186"
- },
- {
- "@id": "urn:nrel_example/nrel00000236"
- },
- {
- "@id": "urn:nrel_example/nrel00000245"
- },
- {
- "@id": "urn:nrel_example/nrel00000339"
- },
- {
- "@id": "urn:nrel_example/nrel00000444"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000627"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@value": "nrel00001172"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000143",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000184"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000743"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001267"
+ "@value": "nrel00000143"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000238",
+ "@id": "urn:nrel_example/nrel00000715",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000238"
+ "@value": "nrel00000715"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000515",
+ "@id": "urn:nrel_example/nrel00000842",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000745"
+ "@id": "urn:nrel_example/nrel00000939"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000160"
+ "@id": "urn:nrel_example/nrel00000708"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001286"
+ "@id": "urn:nrel_example/nrel00001090"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000515"
+ "@value": "nrel00000842"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000441",
+ "@id": "urn:nrel_example/nrel00000251",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -2754,75 +2698,102 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000441"
+ "@value": "nrel00000251"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001084",
+ "@id": "urn:nrel_example/nrel00000406",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00001211"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001084"
+ "@value": "nrel00000406"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000866",
+ "@id": "urn:nrel_example/nrel00000985",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000866"
+ "@value": "nrel00000985"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000698",
+ "@id": "urn:nrel_example/nrel00000254",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Damper"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000424"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001274"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000288"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000617"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000254"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001152",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000698"
+ "@value": "nrel00001152"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000797",
+ "@id": "urn:nrel_example/nrel00000927",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -2831,353 +2802,413 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@value": "nrel00000927"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001329",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000207"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000709"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000797"
+ "@value": "nrel00001329"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001145",
+ "@id": "urn:nrel_example/nrel00000246",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000649"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000553"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000182"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001145"
+ "@value": "nrel00000246"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000548",
+ "@id": "urn:nrel_example/nrel00000509",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000548"
+ "@value": "nrel00000509"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000671",
+ "@id": "urn:nrel_example/nrel00000303",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000671"
+ "@value": "nrel00000303"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000746",
+ "@id": "urn:nrel_example/nrel00000799",
"@type": [
- "http://data.ashrae.org/standard223#EAU",
- "http://data.ashrae.org/standard223#Equipment"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000343"
+ "@id": "urn:nrel_example/nrel00000217"
},
{
- "@id": "urn:nrel_example/nrel00000429"
+ "@id": "urn:nrel_example/nrel00000613"
},
{
- "@id": "urn:nrel_example/nrel00000675"
- },
+ "@id": "urn:nrel_example/nrel00001292"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000771"
+ "@id": "urn:nrel_example/nrel00000161"
},
{
- "@id": "urn:nrel_example/nrel00001003"
+ "@id": "urn:nrel_example/nrel00001056"
},
{
- "@id": "urn:nrel_example/nrel00001089"
+ "@id": "urn:nrel_example/nrel00001183"
},
{
- "@id": "urn:nrel_example/nrel00001100"
+ "@id": "urn:nrel_example/nrel00001300"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000147"
},
{
- "@id": "urn:nrel_example/nrel00001119"
+ "@id": "urn:nrel_example/nrel00000565"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000799"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000416",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000050"
+ "@id": "urn:nrel_example/nrel00000287"
},
{
- "@id": "urn:nrel_example/nrel00000134"
+ "@id": "urn:nrel_example/nrel00000467"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000669"
+ "@id": "urn:nrel_example/nrel00000314"
},
{
- "@id": "urn:nrel_example/nrel00000853"
+ "@id": "urn:nrel_example/nrel00000391"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000746"
+ "@value": "nrel00000416"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000564",
+ "@id": "urn:nrel_example/nrel00000463",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000564"
+ "@value": "nrel00000463"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000335",
+ "@id": "urn:nrel_example/nrel00001045",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000335"
+ "@value": "nrel00001045"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000091",
+ "@id": "urn:nrel_example/nrel00000116",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000091"
+ "@value": "nrel00000116"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000073",
+ "@id": "urn:nrel_example/nrel00000146",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000961"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000332"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000073"
+ "@value": "nrel00000146"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000511",
+ "@id": "urn:nrel_example/nrel00001077",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000134"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000511"
+ "@value": "nrel00001077"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000848",
+ "@id": "urn:nrel_example/nrel00000423",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000581"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000754"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000146"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000570"
- },
+ "@value": "nrel00000423"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000027",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001013"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001323"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000511"
- },
+ "@value": "nrel00000027"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000768",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000727"
+ "@id": "urn:nrel_example/nrel00001047"
},
{
- "@id": "urn:nrel_example/nrel00000774"
- },
+ "@id": "urn:nrel_example/nrel00001068"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001184"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001287"
+ "@value": "nrel00000768"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000714",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000848"
+ "@value": "nrel00000714"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000747",
+ "@id": "urn:nrel_example/nrel00000667",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@id": "urn:nrel_example/nrel00000207"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000710"
+ "@id": "urn:nrel_example/nrel00000443"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000747"
+ "@value": "nrel00000667"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000940",
+ "@id": "urn:nrel_example/nrel00000034",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000050"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000940"
+ "@value": "nrel00000034"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000868",
+ "@id": "urn:nrel_example/nrel00000114",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000600"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000477"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000594"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000868"
+ "@value": "nrel00000114"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000725",
+ "@id": "urn:nrel_example/nrel00000351",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000441"
- },
- {
- "@id": "urn:nrel_example/nrel00000590"
+ "@id": "urn:nrel_example/nrel00000172"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -3187,12 +3218,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000725"
+ "@value": "nrel00000351"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000298",
+ "@id": "urn:nrel_example/nrel00000534",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -3208,98 +3239,115 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000298"
+ "@value": "nrel00000534"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001054",
+ "@id": "urn:nrel_example/nrel00001223",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000786"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001149"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000363"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000489"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001054"
+ "@value": "nrel00001223"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001272",
+ "@id": "urn:nrel_example/nrel00000681",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001272"
+ "@value": "nrel00000681"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000958",
+ "@id": "urn:nrel_example/nrel00000827",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000152"
- },
- {
- "@id": "urn:nrel_example/nrel00000521"
- },
- {
- "@id": "urn:nrel_example/nrel00000591"
- },
- {
- "@id": "urn:nrel_example/nrel00000628"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001155"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000208"
- },
+ "@value": "nrel00000827"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000514",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000139"
- },
+ "@value": "nrel00000514"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000680",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000823"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000985"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000958"
+ "@value": "nrel00000680"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000138",
+ "@id": "urn:nrel_example/nrel00001107",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3308,310 +3356,307 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000138"
+ "@value": "nrel00001107"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000427",
+ "@id": "urn:nrel_example/nrel00000450",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000427"
+ "@value": "nrel00000450"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000312",
+ "@id": "urn:nrel_example/nrel00001031",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000869"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001228"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000047"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000196"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000312"
+ "@value": "nrel00001031"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000435",
+ "@id": "urn:nrel_example/nrel00000389",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000110"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000142"
- },
- {
- "@id": "urn:nrel_example/nrel00000460"
- },
- {
- "@id": "urn:nrel_example/nrel00000849"
- },
- {
- "@id": "urn:nrel_example/nrel00000917"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000462"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@value": "nrel00000389"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001214",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000048"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000124"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000641"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000435"
+ "@value": "nrel00001214"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000188",
+ "@id": "urn:nrel_example/nrel00001108",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000249"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000596"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000694"
- },
+ "@value": "nrel00001108"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000219",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000700"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000188"
+ "@value": "nrel00000219"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000130",
+ "@id": "urn:nrel_example/nrel00000477",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000380"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000579"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000130"
+ "@value": "nrel00000477"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000656",
+ "@id": "urn:nrel_example/nrel00000896",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000736"
+ "@id": "urn:nrel_example/nrel00001049"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000969"
+ "@id": "urn:nrel_example/nrel00000114"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001295"
+ "@id": "urn:nrel_example/nrel00000594"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000656"
+ "@value": "nrel00000896"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001071",
+ "@id": "urn:nrel_example/nrel00000789",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000748"
+ "@id": "urn:nrel_example/nrel00000361"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000381"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000770"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001236"
+ "@id": "urn:nrel_example/nrel00001025"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001301"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00001071"
+ "@id": "urn:nrel_example/nrel00000442"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000481"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000918"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001238"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001324"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000625",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000625"
+ "@value": "nrel00000789"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001114",
+ "@id": "urn:nrel_example/nrel00000346",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001086"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000439"
+ },
{
- "@id": "urn:nrel_example/nrel00000336"
+ "@id": "urn:nrel_example/nrel00000873"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000471"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001114"
+ "@value": "nrel00000346"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001216",
+ "@id": "urn:nrel_example/nrel00000700",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001216"
+ "@value": "nrel00000700"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000787",
+ "@id": "urn:nrel_example/nrel00000484",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000080"
+ "@id": "urn:nrel_example/nrel00000059"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000859"
+ "@id": "urn:nrel_example/nrel00000282"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000319"
+ "@id": "urn:nrel_example/nrel00000113"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000787"
+ "@value": "nrel00000484"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001257",
+ "@id": "urn:nrel_example/nrel00000382",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001257"
+ "@value": "nrel00000382"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000349",
+ "@id": "urn:nrel_example/nrel00001327",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -3622,12 +3667,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000349"
+ "@value": "nrel00001327"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000358",
+ "@id": "urn:nrel_example/nrel00000516",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000516"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001280",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -3643,107 +3704,120 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000358"
+ "@value": "nrel00001280"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000859",
+ "@id": "urn:nrel_example/nrel00000817",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000080"
+ "@id": "urn:nrel_example/nrel00001072"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000284"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000987"
+ "@id": "urn:nrel_example/nrel00000684"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000859"
+ "@value": "nrel00000817"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000317",
+ "@id": "urn:nrel_example/nrel00000845",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00000317"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000845"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000415",
+ "@id": "urn:nrel_example/nrel00000796",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000415"
+ "@value": "nrel00000796"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000962",
+ "@id": "urn:nrel_example/nrel00000698",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000962"
+ "@value": "nrel00000698"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000691",
+ "@id": "urn:nrel_example/nrel00001092",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000535"
+ "@id": "urn:nrel_example/nrel00000539"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000763"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000436"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001225"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000691"
+ "@value": "nrel00001092"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000465",
+ "@id": "urn:nrel_example/nrel00000025",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3752,107 +3826,149 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000465"
+ "@value": "nrel00000025"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000786",
+ "@id": "urn:nrel_example/nrel00000610",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000786"
+ "@value": "nrel00000610"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000790",
+ "@id": "urn:nrel_example/nrel00000626",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000004"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000955"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00001030"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001218"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000790"
+ "@value": "nrel00000626"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000022",
+ "@id": "urn:nrel_example/nrel00000780",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000190"
+ "@id": "urn:nrel_example/nrel00000179"
},
{
- "@id": "urn:nrel_example/nrel00000366"
+ "@id": "urn:nrel_example/nrel00001015"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000525"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000826"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001043"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001063"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000191"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000394"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000556"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000592"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001001"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000022"
+ "@value": "nrel00000780"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000207",
+ "@id": "urn:nrel_example/nrel00000237",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000207"
+ "@value": "nrel00000237"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000005",
+ "@id": "urn:nrel_example/nrel00000540",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000005"
+ "@value": "nrel00000540"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000050",
+ "@id": "urn:nrel_example/nrel00000107",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000875"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3861,12 +3977,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000050"
+ "@value": "nrel00000107"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001053",
+ "@id": "urn:nrel_example/nrel00000645",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -3882,87 +3998,86 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001053"
+ "@value": "nrel00000645"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001286",
+ "@id": "urn:nrel_example/nrel00000549",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00000050"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000760"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001286"
+ "@value": "nrel00000549"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001296",
+ "@id": "urn:nrel_example/nrel00001150",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001200"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000274"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001296"
+ "@value": "nrel00001150"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001004",
+ "@id": "urn:nrel_example/nrel00001195",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000221"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000798"
+ },
{
- "@id": "urn:nrel_example/nrel00000336"
+ "@id": "urn:nrel_example/nrel00000888"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000680"
+ "@id": "urn:nrel_example/nrel00000910"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001227"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001004"
+ "@value": "nrel00001195"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000947",
+ "@id": "urn:nrel_example/nrel00000950",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -3971,120 +4086,133 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000947"
+ "@value": "nrel00000950"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000821",
+ "@id": "urn:nrel_example/nrel00000213",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000821"
+ "@value": "nrel00000213"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001093",
+ "@id": "urn:nrel_example/nrel00000888",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001093"
+ "@value": "nrel00000888"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000067",
+ "@id": "urn:nrel_example/nrel00000602",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000032"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000358"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000067"
+ "@value": "nrel00000602"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000485",
+ "@id": "urn:nrel_example/nrel00000678",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000931"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001256"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000485"
+ "@value": "nrel00000678"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000314",
+ "@id": "urn:nrel_example/nrel00000204",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000314"
+ "@value": "nrel00000204"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000014",
+ "@id": "urn:nrel_example/nrel00000306",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000014"
+ "@value": "nrel00000306"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000869",
+ "@id": "urn:nrel_example/nrel00000579",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -4093,388 +4221,430 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000869"
+ "@value": "nrel00000579"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000075",
+ "@id": "urn:nrel_example/nrel00001124",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000075"
+ "@value": "nrel00001124"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001041",
+ "@id": "urn:nrel_example/nrel00001013",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001041"
+ "@value": "nrel00001013"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000964",
+ "@id": "urn:nrel_example/nrel00000364",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000964"
+ "@value": "nrel00000364"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000672",
+ "@id": "urn:nrel_example/nrel00000184",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000672"
+ "@value": "nrel00000184"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000179",
+ "@id": "urn:nrel_example/nrel00000120",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000178"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000264"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000041"
- },
- {
- "@id": "urn:nrel_example/nrel00000097"
- },
- {
- "@id": "urn:nrel_example/nrel00000445"
- },
- {
- "@id": "urn:nrel_example/nrel00000646"
- },
- {
- "@id": "urn:nrel_example/nrel00000696"
- },
- {
- "@id": "urn:nrel_example/nrel00000860"
- },
- {
- "@id": "urn:nrel_example/nrel00000990"
- },
- {
- "@id": "urn:nrel_example/nrel00001031"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001191"
- },
+ "@value": "nrel00000120"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000131",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001230"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000179"
+ "@value": "nrel00000131"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000409",
+ "@id": "urn:nrel_example/nrel00000277",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000966"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000409"
+ "@value": "nrel00000277"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000370",
+ "@id": "urn:nrel_example/nrel00000637",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000370"
+ "@value": "nrel00000637"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001105",
+ "@id": "urn:nrel_example/nrel00000446",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Filter"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000255"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000892"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000564"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001105"
+ "@value": "nrel00000446"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001014",
+ "@id": "urn:nrel_example/nrel00001007",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001014"
+ "@value": "nrel00001007"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000881",
+ "@id": "urn:nrel_example/nrel00000334",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "urn:nrel_example/nrel00000587"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000160"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000544"
+ "@id": "urn:nrel_example/nrel00000433"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000881"
+ "@value": "nrel00000334"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000416",
+ "@id": "urn:nrel_example/nrel00000380",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000287"
- },
- {
- "@id": "urn:nrel_example/nrel00000467"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000314"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000391"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000416"
+ "@value": "nrel00000380"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000471",
+ "@id": "urn:nrel_example/nrel00001119",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000703"
+ },
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00001078"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000471"
+ "@id": "urn:nrel_example/nrel00000406"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001077"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000040",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000072"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000116"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000126"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000164"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000272"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000401"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000558"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000616"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000670"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000935"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001127"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000040"
+ "@value": "nrel00001119"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000102",
+ "@id": "urn:nrel_example/nrel00000630",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000707"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001195"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000353"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000390"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001122"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001328"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000303"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000333"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000534"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000993"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001145"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000102"
+ "@value": "nrel00000630"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001230",
+ "@id": "urn:nrel_example/nrel00000611",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000590"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00001121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000009"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001230"
+ "@value": "nrel00000611"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000719",
+ "@id": "urn:nrel_example/nrel00000956",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000719"
+ "@value": "nrel00000956"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000085",
+ "@id": "urn:nrel_example/nrel00000643",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000085"
+ "@value": "nrel00000643"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000579",
+ "@id": "urn:nrel_example/nrel00001103",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000579"
+ "@value": "nrel00001103"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001068",
+ "@id": "urn:nrel_example/nrel00001192",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -4483,220 +4653,234 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001068"
+ "@value": "nrel00001192"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000109",
+ "@id": "urn:nrel_example/nrel00000064",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000109"
+ "@value": "nrel00000064"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000595",
+ "@id": "urn:nrel_example/nrel00000062",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000514"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000913"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000601"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000793"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000595"
+ "@value": "nrel00000062"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000977",
+ "@id": "urn:nrel_example/nrel00000731",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000640"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001270"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000977"
+ "@value": "nrel00000731"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000621",
+ "@id": "urn:nrel_example/nrel00001246",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000621"
+ "@value": "nrel00001246"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001176",
+ "@id": "urn:nrel_example/nrel00000447",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000137"
- },
- {
- "@id": "urn:nrel_example/nrel00000561"
- },
- {
- "@id": "urn:nrel_example/nrel00001095"
- }
+ "http://data.ashrae.org/standard223#HeatRecoveryCoil"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000625"
+ "@id": "urn:nrel_example/nrel00000660"
},
{
- "@id": "urn:nrel_example/nrel00000668"
+ "@id": "urn:nrel_example/nrel00000899"
},
{
- "@id": "urn:nrel_example/nrel00000810"
+ "@id": "urn:nrel_example/nrel00001166"
},
{
- "@id": "urn:nrel_example/nrel00001102"
+ "@id": "urn:nrel_example/nrel00001240"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000046"
+ "@id": "urn:nrel_example/nrel00000199"
},
{
- "@id": "urn:nrel_example/nrel00000623"
+ "@id": "urn:nrel_example/nrel00000542"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000585"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001061"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001176"
+ "@value": "nrel00000447"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000740",
+ "@id": "urn:nrel_example/nrel00000013",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000740"
+ "@value": "nrel00000013"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000954",
+ "@id": "urn:nrel_example/nrel00000305",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000954"
+ "@value": "nrel00000305"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000395",
+ "@id": "urn:nrel_example/nrel00000023",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000395"
+ "@value": "nrel00000023"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000166",
+ "@id": "urn:nrel_example/nrel00000961",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000166"
+ "@value": "nrel00000961"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000056",
+ "@id": "urn:nrel_example/nrel00000617",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000056"
+ "@value": "nrel00000617"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000653",
+ "@id": "urn:nrel_example/nrel00001319",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -4707,94 +4891,89 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000653"
+ "@value": "nrel00001319"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001313",
+ "@id": "urn:nrel_example/nrel00000875",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000107"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000899"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001313"
+ "@value": "nrel00000875"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000969",
+ "@id": "urn:nrel_example/nrel00000403",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:nrel_example/nrel00000736"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000054"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000610"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000969"
+ "@value": "nrel00000403"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000461",
+ "@id": "urn:nrel_example/nrel00000266",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001198"
+ "@id": "urn:nrel_example/nrel00000620"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000260"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000461"
+ "@value": "nrel00000266"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000439",
+ "@id": "urn:nrel_example/nrel00000901",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000439"
+ "@value": "nrel00000901"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000529",
+ "@id": "urn:nrel_example/nrel00000946",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -4810,167 +4989,136 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000529"
+ "@value": "nrel00000946"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000833",
+ "@id": "urn:nrel_example/nrel00001058",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000074"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001027"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000206"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000833"
+ "@value": "nrel00001058"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000048",
+ "@id": "urn:nrel_example/nrel00000835",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000048"
+ "@value": "nrel00000835"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000741",
+ "@id": "urn:nrel_example/nrel00000140",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000463"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001307"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000741"
+ "@value": "nrel00000140"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000558",
+ "@id": "urn:nrel_example/nrel00001027",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000122"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000206"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000537"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000558"
+ "@value": "nrel00001027"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000163",
+ "@id": "urn:nrel_example/nrel00000697",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000163"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000674",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000674"
+ "@value": "nrel00000697"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
+ "@id": "urn:nrel_example/nrel00001014",
"@type": [
- "http://data.ashrae.org/standard223#Class",
- "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
- "http://www.w3.org/ns/shacl#NodeShape"
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "EnumerationKind FlowStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000756",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000756"
+ "@value": "nrel00001014"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000094",
+ "@id": "urn:nrel_example/nrel00000711",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -4986,145 +5134,161 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000094"
+ "@value": "nrel00000711"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000058",
+ "@id": "urn:nrel_example/nrel00001213",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000760"
- },
- {
- "@id": "urn:nrel_example/nrel00000984"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001260"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000058"
+ "@value": "nrel00001213"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000498",
+ "@id": "urn:nrel_example/nrel00000071",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000498"
+ "@value": "nrel00000071"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000722",
+ "@id": "urn:nrel_example/nrel00000922",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000722"
+ "@value": "nrel00000922"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001226",
+ "@id": "urn:nrel_example/nrel00000053",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000461"
+ },
{
- "@value": "nrel00001226"
+ "@id": "urn:nrel_example/nrel00000931"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000714",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000012"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000492"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000550"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000562"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000566"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000572"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000607"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000648"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000877"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001075"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001093"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000714"
+ "@value": "nrel00000053"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000857",
+ "@id": "urn:nrel_example/nrel00001184",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000857"
+ "@value": "nrel00001184"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000318",
+ "@id": "urn:nrel_example/nrel00000619",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000318"
+ "@value": "nrel00000619"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000176",
+ "@id": "urn:nrel_example/nrel00001084",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -5140,250 +5304,290 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000176"
+ "@value": "nrel00001084"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001237",
+ "@id": "urn:nrel_example/nrel00001016",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001237"
+ "@value": "nrel00001016"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001224",
+ "@id": "urn:nrel_example/nrel00001008",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000092"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000400"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000454"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000017"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000305"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000797"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001144"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000275"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000738"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001224"
+ "@value": "nrel00001008"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000286",
+ "@id": "urn:nrel_example/nrel00000478",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000474"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000708"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000345"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000286"
+ "@value": "nrel00000478"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000464",
+ "@id": "urn:nrel_example/nrel00000268",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:nrel_example/nrel00000862"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000825"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000956"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000464"
+ "@value": "nrel00000268"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000041",
+ "@id": "urn:nrel_example/nrel00000488",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000041"
+ "@value": "nrel00000488"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000778",
+ "@id": "urn:nrel_example/nrel00001065",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@value": "nrel00001065"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001183",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000778"
+ "@value": "nrel00001183"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000623",
+ "@id": "urn:nrel_example/nrel00000185",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000623"
+ "@value": "nrel00000185"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000432",
+ "@id": "urn:nrel_example/nrel00000492",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000432"
+ "@value": "nrel00000492"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000713",
+ "@id": "urn:nrel_example/nrel00000250",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000713"
+ "@value": "nrel00000250"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000144",
+ "@id": "urn:nrel_example/nrel00000843",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000144"
+ "@value": "nrel00000843"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000189",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Class",
+ "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "http://www.w3.org/ns/shacl#NodeShape"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "EnumerationKind AlarmStatus"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000163"
- },
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
{
- "@id": "urn:nrel_example/nrel00001094"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000211"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000189"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001086",
+ "@id": "urn:nrel_example/nrel00000009",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001086"
+ "@value": "nrel00000009"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001064",
+ "@id": "urn:nrel_example/nrel00000869",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -5394,204 +5598,175 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001064"
+ "@value": "nrel00000869"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001169",
+ "@id": "urn:nrel_example/nrel00000881",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000635"
+ "@id": "urn:nrel_example/nrel00000544"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001169"
+ "@value": "nrel00000881"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000799",
+ "@id": "urn:nrel_example/nrel00001201",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000217"
- },
- {
- "@id": "urn:nrel_example/nrel00000613"
- },
- {
- "@id": "urn:nrel_example/nrel00001292"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000161"
- },
- {
- "@id": "urn:nrel_example/nrel00001056"
- },
- {
- "@id": "urn:nrel_example/nrel00001183"
- },
- {
- "@id": "urn:nrel_example/nrel00001300"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000147"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000565"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000799"
+ "@value": "nrel00001201"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001031",
+ "@id": "urn:nrel_example/nrel00000217",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "urn:nrel_example/nrel00000161"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00000565"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001031"
+ "@value": "nrel00000217"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001048",
+ "@id": "urn:nrel_example/nrel00000395",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001048"
+ "@value": "nrel00000395"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000846",
+ "@id": "urn:nrel_example/nrel00000473",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000846"
+ "@value": "nrel00000473"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000761",
+ "@id": "urn:nrel_example/nrel00000811",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000761"
+ "@value": "nrel00000811"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000888",
+ "@id": "urn:nrel_example/nrel00001131",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000941"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000888"
+ "@id": "urn:nrel_example/nrel00000121"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000583",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000681"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000583"
+ "@value": "nrel00001131"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000105",
+ "@id": "urn:nrel_example/nrel00000856",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000045"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00000969"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000610"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000105"
+ "@value": "nrel00000856"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000087",
+ "@id": "urn:nrel_example/nrel00000840",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -5602,124 +5777,109 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000087"
+ "@value": "nrel00000840"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000972",
+ "@id": "urn:nrel_example/nrel00001247",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000972"
+ "@value": "nrel00001247"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000680",
+ "@id": "urn:nrel_example/nrel00000632",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000680"
+ "@value": "nrel00000632"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000424",
+ "@id": "urn:nrel_example/nrel00000102",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000077"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000424"
+ "@value": "nrel00000102"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000117",
+ "@id": "urn:nrel_example/nrel00001029",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000966"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000282"
+ "@id": "urn:nrel_example/nrel00000388"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000845"
+ "@id": "urn:nrel_example/nrel00000673"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000117"
+ "@value": "nrel00001029"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001261",
+ "@id": "urn:nrel_example/nrel00000604",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00001136"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00001255"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001261"
+ "@value": "nrel00000604"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000878",
+ "@id": "urn:nrel_example/nrel00001225",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -5728,101 +5888,75 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000878"
+ "@value": "nrel00001225"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000985",
+ "@id": "urn:nrel_example/nrel00001111",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000985"
+ "@value": "nrel00001111"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001185",
+ "@id": "urn:nrel_example/nrel00000717",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000414"
- },
- {
- "@id": "urn:nrel_example/nrel00000533"
- },
- {
- "@id": "urn:nrel_example/nrel00000667"
- },
- {
- "@id": "urn:nrel_example/nrel00000755"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001329"
+ "@id": "urn:nrel_example/nrel00000122"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000207"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000864"
+ "@id": "urn:nrel_example/nrel00001027"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000443"
- },
- {
- "@id": "urn:nrel_example/nrel00000709"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001163"
+ "@id": "urn:nrel_example/nrel00001167"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001185"
+ "@value": "nrel00000717"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000528",
+ "@id": "urn:nrel_example/nrel00000542",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000528"
+ "@value": "nrel00000542"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000182",
+ "@id": "urn:nrel_example/nrel00000847",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -5838,217 +5972,152 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000182"
+ "@value": "nrel00000847"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000294",
+ "@id": "urn:nrel_example/nrel00001181",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000737"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000915"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000294"
+ "@value": "nrel00001181"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000748",
+ "@id": "urn:nrel_example/nrel00000208",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000748"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Overridden",
- "@type": [
- "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
- "http://data.ashrae.org/standard223#EnumerationKind-Override"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@language": "en",
- "@value": "AlarmStatus-Ok"
- },
- {
- "@language": "en",
- "@value": "Override-Overridden"
+ "@value": "nrel00000208"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000544",
+ "@id": "urn:nrel_example/nrel00000662",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000544"
+ "@value": "nrel00000662"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000934",
+ "@id": "urn:nrel_example/nrel00000641",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000153"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000302"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000653"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001249"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000934"
+ "@value": "nrel00000641"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001008",
+ "@id": "urn:nrel_example/nrel00000436",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000092"
- },
- {
- "@id": "urn:nrel_example/nrel00000400"
- },
- {
- "@id": "urn:nrel_example/nrel00000454"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000017"
- },
- {
- "@id": "urn:nrel_example/nrel00000305"
- },
- {
- "@id": "urn:nrel_example/nrel00000797"
- },
- {
- "@id": "urn:nrel_example/nrel00001144"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000275"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000738"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001008"
+ "@value": "nrel00000436"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000536",
+ "@id": "urn:nrel_example/nrel00001121",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00001197"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000536"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000541",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000009"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000068"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000541"
+ "@value": "nrel00001121"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000703",
+ "@id": "urn:nrel_example/nrel00001177",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000215"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001108"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000698"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001188"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000703"
+ "@value": "nrel00001177"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001204",
+ "@id": "urn:nrel_example/nrel00000094",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -6064,118 +6133,65 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001204"
+ "@value": "nrel00000094"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000062",
+ "@id": "urn:nrel_example/nrel00000737",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000514"
- },
- {
- "@id": "urn:nrel_example/nrel00000913"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000601"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000793"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000062"
+ "@value": "nrel00000737"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000348",
+ "@id": "urn:nrel_example/nrel00000646",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000348"
+ "@value": "nrel00000646"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000400",
+ "@id": "urn:nrel_example/nrel00000702",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000305"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000738"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000400"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000804",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000612"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000895"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000804"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000763",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000763"
+ "@value": "nrel00000702"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000391",
+ "@id": "urn:nrel_example/nrel00000910",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -6186,12 +6202,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000391"
+ "@value": "nrel00000910"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001310",
+ "@id": "urn:nrel_example/nrel00000778",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -6207,56 +6223,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001310"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000034",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000034"
+ "@value": "nrel00000778"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000419",
+ "@id": "urn:nrel_example/nrel00000651",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000419"
+ "@value": "nrel00000651"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000215",
+ "@id": "urn:nrel_example/nrel00000595",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6265,12 +6260,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000215"
+ "@value": "nrel00000595"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000459",
+ "@id": "urn:nrel_example/nrel00001086",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -6281,12 +6276,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000459"
+ "@value": "nrel00001086"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000723",
+ "@id": "urn:nrel_example/nrel00000485",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -6297,266 +6292,228 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000723"
+ "@value": "nrel00000485"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000332",
+ "@id": "urn:nrel_example/nrel00000926",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000332"
+ "@value": "nrel00000926"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000816",
+ "@id": "urn:nrel_example/nrel00000501",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001125"
+ "@id": "urn:nrel_example/nrel00000236"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@id": "urn:nrel_example/nrel00001165"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000002"
+ "@id": "urn:nrel_example/nrel00000567"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000816"
+ "@value": "nrel00000501"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000436",
+ "@id": "urn:nrel_example/nrel00001277",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001080"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001123"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000436"
+ "@value": "nrel00001277"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000887",
+ "@id": "urn:nrel_example/nrel00000739",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001311"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000575"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000887"
+ "@value": "nrel00000739"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000608",
+ "@id": "urn:nrel_example/nrel00000322",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001265"
+ "@id": "urn:nrel_example/nrel00001259"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000500"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000809"
+ "@id": "urn:nrel_example/nrel00001168"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000608"
+ "@value": "nrel00000322"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000448",
+ "@id": "urn:nrel_example/nrel00000642",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000586"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000923"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000448"
+ "@value": "nrel00000642"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001330",
+ "@id": "urn:nrel_example/nrel00000945",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000846"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000121"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000576"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001330"
+ "@value": "nrel00000945"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000413",
+ "@id": "urn:nrel_example/nrel00001322",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000927"
- },
- {
- "@id": "urn:nrel_example/nrel00000950"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000013"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000103"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000413"
+ "@value": "nrel00001322"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000649",
+ "@id": "urn:nrel_example/nrel00000764",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000364"
- },
- {
- "@id": "urn:nrel_example/nrel00000516"
- },
- {
- "@id": "urn:nrel_example/nrel00000893"
- },
- {
- "@id": "urn:nrel_example/nrel00001139"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000182"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001178"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000649"
+ "@value": "nrel00000764"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000293",
+ "@id": "urn:nrel_example/nrel00000524",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001069"
+ "@id": "urn:nrel_example/nrel00000967"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000419"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000293"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001253",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000865"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001253"
+ "@value": "nrel00000524"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000076",
+ "@id": "urn:nrel_example/nrel00001051",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -6565,79 +6522,74 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00001047"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000076"
+ "@value": "nrel00001051"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000417",
+ "@id": "urn:nrel_example/nrel00000117",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000966"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000282"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000845"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000417"
+ "@value": "nrel00000117"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000491",
+ "@id": "urn:nrel_example/nrel00000971",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000864"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000491"
+ "@value": "nrel00000971"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000570",
+ "@id": "urn:nrel_example/nrel00000819",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000570"
+ "@value": "nrel00000819"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001112",
+ "@id": "urn:nrel_example/nrel00000756",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6646,62 +6598,51 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001112"
+ "@value": "nrel00000756"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000561",
+ "@id": "urn:nrel_example/nrel00000299",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000448"
- },
- {
- "@id": "urn:nrel_example/nrel00000921"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000106"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001054"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000561"
+ "@value": "nrel00000299"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000766",
+ "@id": "urn:nrel_example/nrel00000327",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000766"
+ "@value": "nrel00000327"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000281",
+ "@id": "urn:nrel_example/nrel00000704",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -6710,12 +6651,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000281"
+ "@value": "nrel00000704"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001000",
+ "@id": "urn:nrel_example/nrel00000020",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -6731,270 +6672,225 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001000"
+ "@value": "nrel00000020"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000792",
+ "@id": "urn:nrel_example/nrel00000583",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000792"
+ "@value": "nrel00000583"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000839",
+ "@id": "urn:nrel_example/nrel00000569",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00001092"
- },
- {
- "@id": "urn:nrel_example/nrel00001115"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000356"
- },
- {
- "@id": "urn:nrel_example/nrel00000508"
- },
- {
- "@id": "urn:nrel_example/nrel00001062"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001189"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000125"
- },
- {
- "@id": "urn:nrel_example/nrel00000552"
- },
- {
- "@id": "urn:nrel_example/nrel00000654"
- },
- {
- "@id": "urn:nrel_example/nrel00001126"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001247"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000839"
+ "@value": "nrel00000569"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000024",
+ "@id": "urn:nrel_example/nrel00000442",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000024"
+ "@value": "nrel00000442"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000788",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Default",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "http://data.ashrae.org/standard223#EnumerationKind-Override"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000788"
+ "@language": "en",
+ "@value": "AlarmStatus-Alarm"
+ },
+ {
+ "@language": "en",
+ "@value": "Override-Default"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001246",
+ "@id": "urn:nrel_example/nrel00000513",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001246"
+ "@value": "nrel00000513"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000324",
+ "@id": "urn:nrel_example/nrel00000589",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "urn:nrel_example/nrel00000240"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000903"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000064"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000324"
+ "@value": "nrel00000589"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000944",
+ "@id": "urn:nrel_example/nrel00001215",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000944"
+ "@value": "nrel00001215"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001136",
+ "@id": "urn:nrel_example/nrel00000110",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001036"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001302"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00001136"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000594",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000634"
+ },
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00001137"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000594"
+ "@value": "nrel00000110"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000268",
+ "@id": "urn:nrel_example/nrel00000722",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000268"
+ "@value": "nrel00000722"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001309",
+ "@id": "urn:nrel_example/nrel00000932",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000207"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001086"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001309"
+ "@value": "nrel00000932"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000794",
+ "@id": "urn:nrel_example/nrel00000902",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001197"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001121"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001306"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000100"
+ },
{
- "@value": "nrel00000794"
+ "@id": "urn:nrel_example/nrel00000775"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000704",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7003,41 +6899,30 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000704"
+ "@value": "nrel00000902"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000581",
+ "@id": "urn:nrel_example/nrel00000523",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000223"
- },
- {
- "@id": "urn:nrel_example/nrel00000320"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000403"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000850"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000581"
+ "@value": "nrel00000523"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000399",
+ "@id": "urn:nrel_example/nrel00000045",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7046,131 +6931,91 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000399"
+ "@value": "nrel00000045"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000720",
+ "@id": "urn:nrel_example/nrel00000359",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000441"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000720"
+ "@value": "nrel00000359"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000629",
+ "@id": "urn:nrel_example/nrel00001102",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000318"
- },
- {
- "@id": "urn:nrel_example/nrel00000393"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000105"
- },
- {
- "@id": "urn:nrel_example/nrel00000128"
- },
- {
- "@id": "urn:nrel_example/nrel00000218"
- },
- {
- "@id": "urn:nrel_example/nrel00000398"
- },
- {
- "@id": "urn:nrel_example/nrel00000519"
- },
- {
- "@id": "urn:nrel_example/nrel00000528"
- },
- {
- "@id": "urn:nrel_example/nrel00000540"
- },
- {
- "@id": "urn:nrel_example/nrel00000548"
- },
- {
- "@id": "urn:nrel_example/nrel00000702"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001140"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000629"
+ "@value": "nrel00001102"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000800",
+ "@id": "urn:nrel_example/nrel00000594",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001064"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000216"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000800"
+ "@value": "nrel00000594"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001130",
+ "@id": "urn:nrel_example/nrel00000940",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000050"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001130"
+ "@value": "nrel00000940"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001109",
+ "@id": "urn:nrel_example/nrel00000988",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -7186,35 +7031,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001109"
+ "@value": "nrel00000988"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001184",
+ "@id": "urn:nrel_example/nrel00000648",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001184"
+ "@value": "nrel00000648"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000737",
+ "@id": "urn:nrel_example/nrel00001226",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7223,46 +7068,59 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000737"
+ "@value": "nrel00001226"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000261",
+ "@id": "urn:nrel_example/nrel00000443",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000261"
+ "@value": "nrel00000443"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000249",
+ "@id": "urn:nrel_example/nrel00001301",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000249"
+ "@value": "nrel00001301"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000462",
+ "@id": "urn:nrel_example/nrel00000397",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000255"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000908"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7271,332 +7129,343 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000462"
+ "@value": "nrel00000397"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001188",
+ "@id": "urn:nrel_example/nrel00000335",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001188"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001242",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001242"
+ "@value": "nrel00000335"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001046",
+ "@id": "urn:nrel_example/nrel00001088",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001046"
+ "@value": "nrel00001088"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000524",
+ "@id": "urn:nrel_example/nrel00001187",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000967"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000733"
+ },
{
- "@id": "urn:nrel_example/nrel00000865"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00001181"
+ },
{
- "@value": "nrel00000524"
+ "@id": "urn:nrel_example/nrel00001205"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000631",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000138"
+ "@id": "urn:nrel_example/nrel00000504"
},
{
- "@id": "urn:nrel_example/nrel00001200"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "@id": "urn:nrel_example/nrel00000595"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000705"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000737"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000665"
+ "@id": "urn:nrel_example/nrel00000263"
},
{
- "@id": "urn:nrel_example/nrel00001085"
+ "@id": "urn:nrel_example/nrel00000915"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000631"
+ "@value": "nrel00001187"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000304",
+ "@id": "urn:nrel_example/nrel00000202",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000304"
+ "@value": "nrel00000202"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000420",
+ "@id": "urn:nrel_example/nrel00000261",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000420"
+ "@value": "nrel00000261"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000681",
+ "@id": "urn:nrel_example/nrel00001169",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000635"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000681"
+ "@value": "nrel00001169"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000484",
+ "@id": "urn:nrel_example/nrel00001046",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001046"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000247",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000059"
+ "@id": "urn:nrel_example/nrel00001105"
}
],
"http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000282"
+ "@id": "urn:nrel_example/nrel00000859"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000113"
+ "@id": "urn:nrel_example/nrel00000987"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000484"
+ "@value": "nrel00000247"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000128",
+ "@id": "urn:nrel_example/nrel00001063",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000128"
+ "@value": "nrel00001063"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000690",
+ "@id": "urn:nrel_example/nrel00000958",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000152"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000521"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000591"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000628"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001155"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000208"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000354"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000139"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000823"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000985"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000690"
+ "@value": "nrel00000958"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000955",
+ "@id": "urn:nrel_example/nrel00001324",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000955"
+ "@value": "nrel00001324"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000492",
+ "@id": "urn:nrel_example/nrel00001237",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000492"
+ "@value": "nrel00001237"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000684",
+ "@id": "urn:nrel_example/nrel00000672",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000684"
+ "@value": "nrel00000672"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001108",
+ "@id": "urn:nrel_example/nrel00001071",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00001108"
+ "@id": "urn:nrel_example/nrel00000748"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000913",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001236"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000913"
+ "@value": "nrel00001071"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000082",
+ "@id": "urn:nrel_example/nrel00000424",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000077"
+ }
+ ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -7604,62 +7473,54 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000082"
+ "@value": "nrel00000424"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000809",
+ "@id": "urn:nrel_example/nrel00000274",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000809"
+ "@value": "nrel00000274"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001180",
+ "@id": "urn:nrel_example/nrel00000340",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000172"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000051"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000885"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001179"
+ "@id": "urn:nrel_example/nrel00000202"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001180"
+ "@value": "nrel00000340"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000326",
+ "@id": "urn:nrel_example/nrel00000016",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -7670,28 +7531,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000326"
+ "@value": "nrel00000016"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000357",
+ "@id": "urn:nrel_example/nrel00001070",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000357"
+ "@value": "nrel00001070"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001132",
+ "@id": "urn:nrel_example/nrel00000375",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -7702,51 +7568,51 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001132"
+ "@value": "nrel00000375"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000474",
+ "@id": "urn:nrel_example/nrel00000195",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000474"
+ "@value": "nrel00000195"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000289",
+ "@id": "urn:nrel_example/nrel00000145",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000289"
+ "@value": "nrel00000145"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000458",
+ "@id": "urn:nrel_example/nrel00000181",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
@@ -7760,25 +7626,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000458"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001263",
- "@type": [
- "http://data.ashrae.org/standard223#Equipment"
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001263"
+ "@value": "nrel00000181"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001183",
+ "@id": "urn:nrel_example/nrel00000297",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -7787,380 +7642,333 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001183"
+ "@value": "nrel00000297"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000610",
+ "@id": "urn:nrel_example/nrel00001044",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00000364"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000610"
+ "@id": "urn:nrel_example/nrel00000553"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000893",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000555"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000893"
+ "@value": "nrel00001044"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000059",
+ "@id": "urn:nrel_example/nrel00000707",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000735"
+ },
{
- "@value": "nrel00000059"
+ "@id": "urn:nrel_example/nrel00001172"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000141",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000086"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000089"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000129"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000326"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000513"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000659"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000728"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001098"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001110"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001237"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000141"
+ "@value": "nrel00000707"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000982",
+ "@id": "urn:nrel_example/nrel00000782",
"@type": [
- "http://data.ashrae.org/standard223#AirHandlingUnit"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000007"
+ "@id": "urn:nrel_example/nrel00000148"
},
{
- "@id": "urn:nrel_example/nrel00000053"
+ "@id": "urn:nrel_example/nrel00000647"
},
{
- "@id": "urn:nrel_example/nrel00000061"
- },
+ "@id": "urn:nrel_example/nrel00001037"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000254"
+ "@id": "urn:nrel_example/nrel00000190"
},
{
- "@id": "urn:nrel_example/nrel00000446"
+ "@id": "urn:nrel_example/nrel00000722"
},
{
- "@id": "urn:nrel_example/nrel00000447"
+ "@id": "urn:nrel_example/nrel00001046"
},
{
- "@id": "urn:nrel_example/nrel00000683"
- },
+ "@id": "urn:nrel_example/nrel00001052"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000992"
+ "@id": "urn:nrel_example/nrel00000820"
},
{
- "@id": "urn:nrel_example/nrel00001087"
+ "@id": "urn:nrel_example/nrel00001067"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000782"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000934",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000078"
+ "@id": "urn:nrel_example/nrel00000153"
},
{
- "@id": "urn:nrel_example/nrel00000211"
+ "@id": "urn:nrel_example/nrel00000302"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000034"
+ "@id": "urn:nrel_example/nrel00000653"
},
{
- "@id": "urn:nrel_example/nrel00001070"
+ "@id": "urn:nrel_example/nrel00001249"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000982"
+ "@value": "nrel00000934"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000382",
+ "@id": "urn:nrel_example/nrel00000471",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000382"
+ "@value": "nrel00000471"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000620",
+ "@id": "urn:nrel_example/nrel00000056",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00000620"
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000056"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001174",
+ "@id": "urn:nrel_example/nrel00000169",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000588"
- },
- {
- "@id": "urn:nrel_example/nrel00001294"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000020"
- },
- {
- "@id": "urn:nrel_example/nrel00000029"
- },
- {
- "@id": "urn:nrel_example/nrel00000257"
- },
- {
- "@id": "urn:nrel_example/nrel00000295"
- },
- {
- "@id": "urn:nrel_example/nrel00000569"
- },
- {
- "@id": "urn:nrel_example/nrel00000650"
- },
- {
- "@id": "urn:nrel_example/nrel00000796"
- },
- {
- "@id": "urn:nrel_example/nrel00000857"
- },
- {
- "@id": "urn:nrel_example/nrel00000890"
- },
- {
- "@id": "urn:nrel_example/nrel00001076"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001154"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001174"
+ "@value": "nrel00000169"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000646",
+ "@id": "urn:nrel_example/nrel00000907",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000043"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000790"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001182"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001242"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000646"
+ "@value": "nrel00000907"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001017",
+ "@id": "urn:nrel_example/nrel00001316",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001017"
+ "@value": "nrel00001316"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000782",
+ "@id": "urn:nrel_example/nrel00000033",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000148"
- },
- {
- "@id": "urn:nrel_example/nrel00000647"
- },
- {
- "@id": "urn:nrel_example/nrel00001037"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000190"
- },
- {
- "@id": "urn:nrel_example/nrel00000722"
- },
- {
- "@id": "urn:nrel_example/nrel00001046"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001052"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000820"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001067"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000782"
+ "@value": "nrel00000033"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000226",
+ "@id": "urn:nrel_example/nrel00000762",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000031"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000371"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000063"
- },
- {
- "@id": "urn:nrel_example/nrel00000269"
- },
- {
- "@id": "urn:nrel_example/nrel00000663"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001316"
+ "@value": "nrel00000762"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000601",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000204"
- },
- {
- "@id": "urn:nrel_example/nrel00000213"
- },
- {
- "@id": "urn:nrel_example/nrel00000557"
- },
- {
- "@id": "urn:nrel_example/nrel00000803"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001293"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000226"
+ "@value": "nrel00000601"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000920",
+ "@id": "urn:nrel_example/nrel00000674",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000638"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000412"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000920"
+ "@value": "nrel00000674"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000682",
+ "@id": "urn:nrel_example/nrel00001240",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -8171,21 +7979,21 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000682"
+ "@value": "nrel00001240"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000346",
+ "@id": "urn:nrel_example/nrel00001219",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000439"
+ "@id": "urn:nrel_example/nrel00000462"
},
{
- "@id": "urn:nrel_example/nrel00000873"
+ "@id": "urn:nrel_example/nrel00000924"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -8195,219 +8003,179 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000346"
+ "@value": "nrel00001219"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000513",
+ "@id": "urn:nrel_example/nrel00001154",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000513"
+ "@value": "nrel00001154"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001249",
+ "@id": "urn:nrel_example/nrel00001080",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001249"
+ "@value": "nrel00001080"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000284",
+ "@id": "urn:nrel_example/nrel00000563",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000284"
+ "@value": "nrel00000563"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000803",
+ "@id": "urn:nrel_example/nrel00000282",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000966"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000091"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000113"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000803"
+ "@value": "nrel00000282"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001095",
+ "@id": "urn:nrel_example/nrel00000426",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000668"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000046"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "nrel00001095"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000582",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "urn:nrel_example/nrel00000971"
+ },
{
- "@id": "urn:nrel_example/nrel00001040"
+ "@id": "urn:nrel_example/nrel00001144"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000571"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000582"
+ "@value": "nrel00000426"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000765",
+ "@id": "urn:nrel_example/nrel00000669",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000765"
+ "@value": "nrel00000669"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000115",
+ "@id": "urn:nrel_example/nrel00000660",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000115"
+ "@value": "nrel00000660"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000010",
+ "@id": "urn:nrel_example/nrel00000188",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000818"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000336"
- }
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000739"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000249"
+ },
{
- "@value": "nrel00000010"
+ "@id": "urn:nrel_example/nrel00000596"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000773",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000694"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000700"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000773"
+ "@value": "nrel00000188"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001102",
+ "@id": "urn:nrel_example/nrel00000354",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -8416,37 +8184,18 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001102"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001073",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00001073"
+ "@value": "nrel00000354"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000605",
+ "@id": "urn:nrel_example/nrel00000307",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000151"
- },
- {
- "@id": "urn:nrel_example/nrel00001229"
+ "@id": "urn:nrel_example/nrel00000517"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -8456,60 +8205,65 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000605"
+ "@value": "nrel00000307"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000482",
+ "@id": "urn:nrel_example/nrel00000373",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000482"
+ "@value": "nrel00000373"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000150",
+ "@id": "urn:nrel_example/nrel00000507",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000150"
+ "@value": "nrel00000507"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001075",
+ "@id": "urn:nrel_example/nrel00000567",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001075"
+ "@value": "nrel00000567"
}
]
},
@@ -8535,23 +8289,7 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000146",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000146"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000440",
+ "@id": "urn:nrel_example/nrel00000548",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -8562,37 +8300,37 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000440"
+ "@value": "nrel00000548"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000487",
+ "@id": "urn:nrel_example/nrel00000134",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000487"
+ "@value": "nrel00000134"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000426",
+ "@id": "urn:nrel_example/nrel00000911",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000971"
+ "@id": "urn:nrel_example/nrel00000869"
},
{
- "@id": "urn:nrel_example/nrel00001144"
+ "@id": "urn:nrel_example/nrel00001183"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -8602,147 +8340,141 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000426"
+ "@value": "nrel00000911"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000527",
+ "@id": "urn:nrel_example/nrel00000536",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000527"
+ "@value": "nrel00000536"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000650",
+ "@id": "urn:nrel_example/nrel00000899",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00000875"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000650"
+ "@value": "nrel00000899"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000337",
+ "@id": "urn:nrel_example/nrel00000138",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000469"
- },
- {
- "@id": "urn:nrel_example/nrel00000509"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000119"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000671"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000337"
+ "@value": "nrel00000138"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000864",
+ "@id": "urn:nrel_example/nrel00000060",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00000864"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
- ]
- },
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000060"
+ }
+ ]
+ },
{
- "@id": "urn:nrel_example/nrel00000837",
+ "@id": "urn:nrel_example/nrel00000383",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000430"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000795"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000837"
+ "@value": "nrel00000383"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000454",
+ "@id": "urn:nrel_example/nrel00000347",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000019"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001018"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000411"
- },
+ "@value": "nrel00000347"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000231",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000962"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000454"
+ "@value": "nrel00000231"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000287",
+ "@id": "urn:nrel_example/nrel00000596",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -8751,206 +8483,259 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000287"
+ "@value": "nrel00000596"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000232",
+ "@id": "urn:nrel_example/nrel00000036",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000232"
+ "@value": "nrel00000036"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000061",
+ "@id": "urn:nrel_example/nrel00001243",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000062"
- },
+ "@id": "urn:nrel_example/nrel00000281"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001199"
+ "@id": "urn:nrel_example/nrel00000708"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000240"
+ "@id": "urn:nrel_example/nrel00000866"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001243"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001254",
+ "@type": [
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000342"
},
{
- "@id": "urn:nrel_example/nrel00000586"
+ "@id": "urn:nrel_example/nrel00000524"
},
{
- "@id": "urn:nrel_example/nrel00000964"
+ "@id": "urn:nrel_example/nrel00000686"
},
{
- "@id": "urn:nrel_example/nrel00001268"
+ "@id": "urn:nrel_example/nrel00000782"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001231"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000498"
+ "@id": "urn:nrel_example/nrel00000688"
},
{
- "@id": "urn:nrel_example/nrel00000529"
- },
+ "@id": "urn:nrel_example/nrel00000967"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000718"
+ "@id": "urn:nrel_example/nrel00000176"
},
{
- "@id": "urn:nrel_example/nrel00001158"
+ "@id": "urn:nrel_example/nrel00000865"
},
{
- "@id": "urn:nrel_example/nrel00001261"
+ "@id": "urn:nrel_example/nrel00001221"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000061"
+ "@value": "nrel00001254"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000327",
+ "@id": "urn:nrel_example/nrel00000483",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00000862"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000464"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001134"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000327"
+ "@value": "nrel00000483"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001195",
+ "@id": "urn:nrel_example/nrel00000965",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000798"
- },
+ "@id": "urn:nrel_example/nrel00000080"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000888"
+ "@id": "urn:nrel_example/nrel00000859"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000910"
- },
+ "@id": "urn:nrel_example/nrel00000005"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001227"
+ "@value": "nrel00000965"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000210",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001195"
+ "@value": "nrel00000210"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000475",
+ "@id": "urn:nrel_example/nrel00001002",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000475"
+ "@value": "nrel00001002"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000190",
+ "@id": "urn:nrel_example/nrel00000564",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000190"
+ "@value": "nrel00000564"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000959",
+ "@id": "urn:nrel_example/nrel00000740",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000959"
+ "@value": "nrel00000740"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001300",
+ "@id": "urn:nrel_example/nrel00001217",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001300"
+ "@value": "nrel00001217"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000013",
+ "@id": "urn:nrel_example/nrel00000456",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
@@ -8960,312 +8745,299 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000013"
+ "@value": "nrel00000456"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000551",
+ "@id": "urn:nrel_example/nrel00001068",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000551"
+ "@value": "nrel00001068"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000095",
+ "@id": "urn:nrel_example/nrel00000132",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000168"
- },
- {
- "@id": "urn:nrel_example/nrel00000312"
- },
- {
- "@id": "urn:nrel_example/nrel00000497"
- },
- {
- "@id": "urn:nrel_example/nrel00000608"
- },
- {
- "@id": "urn:nrel_example/nrel00000799"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000227"
- },
- {
- "@id": "urn:nrel_example/nrel00001265"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000042"
- },
- {
- "@id": "urn:nrel_example/nrel00000726"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000809"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000095"
+ "@value": "nrel00000132"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000602",
+ "@id": "urn:nrel_example/nrel00001230",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000032"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000358"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000602"
+ "@value": "nrel00001230"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000306",
+ "@id": "urn:nrel_example/nrel00001136",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000306"
+ "@value": "nrel00001136"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000998",
+ "@id": "urn:nrel_example/nrel00000417",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000465"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000786"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000998"
+ "@value": "nrel00000417"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000967",
+ "@id": "urn:nrel_example/nrel00000495",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000331"
+ },
{
- "@value": "nrel00000967"
+ "@id": "urn:nrel_example/nrel00001111"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000310",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000270"
+ },
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000476"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000523"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000543"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000706"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000713"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000730"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000819"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000831"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001000"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001039"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000310"
+ "@value": "nrel00000495"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000060",
+ "@id": "urn:nrel_example/nrel00000192",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000971"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001169"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00001060"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001327"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000060"
+ "@value": "nrel00000192"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001213",
+ "@id": "urn:nrel_example/nrel00000793",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001213"
+ "@value": "nrel00000793"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000988",
+ "@id": "urn:nrel_example/nrel00000174",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000988"
+ "@value": "nrel00000174"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001200",
+ "@id": "urn:nrel_example/nrel00000880",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001200"
+ "@value": "nrel00000880"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000333",
+ "@id": "urn:nrel_example/nrel00000301",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000333"
+ "@value": "nrel00000301"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000668",
+ "@id": "urn:nrel_example/nrel00000438",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000668"
+ "@value": "nrel00000438"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001302",
+ "@id": "urn:nrel_example/nrel00001062",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001302"
+ "@value": "nrel00001062"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000366",
+ "@id": "urn:nrel_example/nrel00000822",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000355"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000438"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -9274,113 +9046,170 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000366"
+ "@value": "nrel00000822"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000885",
+ "@id": "urn:nrel_example/nrel00000800",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00001064"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000500"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000216"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000885"
+ "@value": "nrel00000800"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001231",
+ "@id": "urn:nrel_example/nrel00001275",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000366"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000655"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000695"
+ "@value": "nrel00001275"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000615",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000281"
},
{
- "@id": "urn:nrel_example/nrel00001271"
+ "@id": "urn:nrel_example/nrel00000354"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001231"
+ "@value": "nrel00000615"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000685",
+ "@id": "urn:nrel_example/nrel00000135",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000340"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000734"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000906"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000051"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000075"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000914"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001250"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000202"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000740"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000685"
+ "@value": "nrel00000135"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001175",
+ "@id": "urn:nrel_example/nrel00000180",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001175"
+ "@value": "nrel00000180"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001192",
+ "@id": "urn:nrel_example/nrel00000454",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000019"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001018"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000411"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000962"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001192"
+ "@value": "nrel00000454"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000210",
+ "@id": "urn:nrel_example/nrel00001106",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
@@ -9391,52 +9220,70 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000210"
+ "@value": "nrel00001106"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001043",
+ "@id": "urn:nrel_example/nrel00000659",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001043"
+ "@value": "nrel00000659"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000783",
+ "@id": "urn:nrel_example/nrel00000670",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000970"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000984"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@value": "nrel00000670"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000124",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000783"
+ "@value": "nrel00000124"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000389",
+ "@id": "urn:nrel_example/nrel00000526",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -9447,35 +9294,30 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000389"
+ "@value": "nrel00000526"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000456",
+ "@id": "urn:nrel_example/nrel00000949",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000456"
+ "@value": "nrel00000949"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001275",
+ "@id": "urn:nrel_example/nrel00000051",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -9484,28 +9326,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001275"
+ "@value": "nrel00000051"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000043",
+ "@id": "urn:nrel_example/nrel00000572",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000043"
+ "@value": "nrel00000572"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001063",
+ "@id": "urn:nrel_example/nrel00001242",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -9516,14 +9358,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001063"
+ "@value": "nrel00001242"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000111",
+ "@id": "urn:nrel_example/nrel00000411",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -9532,350 +9374,263 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000111"
+ "@value": "nrel00000411"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000110",
+ "@id": "urn:nrel_example/nrel00000294",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00001036"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001302"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000634"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001137"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000110"
+ "@value": "nrel00000294"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000807",
+ "@id": "urn:nrel_example/nrel00000000",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000045"
- },
- {
- "@id": "urn:nrel_example/nrel00001157"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000807"
+ "@value": "nrel00000000"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000187",
+ "@id": "urn:nrel_example/nrel00000794",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000205"
- },
- {
- "@id": "urn:nrel_example/nrel00000273"
- },
- {
- "@id": "urn:nrel_example/nrel00000369"
- },
- {
- "@id": "urn:nrel_example/nrel00000925"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001315"
+ "@id": "urn:nrel_example/nrel00001197"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000441"
- },
+ "@id": "urn:nrel_example/nrel00001121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001047"
+ "@id": "urn:nrel_example/nrel00001306"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000118"
- },
- {
- "@id": "urn:nrel_example/nrel00000132"
- },
- {
- "@id": "urn:nrel_example/nrel00000758"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000187"
+ "@value": "nrel00000794"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001235",
+ "@id": "urn:nrel_example/nrel00000439",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001235"
+ "@value": "nrel00000439"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000027",
+ "@id": "urn:nrel_example/nrel00000969",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000736"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000054"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000610"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000027"
+ "@value": "nrel00000969"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000162",
+ "@id": "urn:nrel_example/nrel00000663",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000162"
+ "@value": "nrel00000663"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000770",
+ "@id": "urn:nrel_example/nrel00000164",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000882"
- },
- {
- "@id": "urn:nrel_example/nrel00001192"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000143"
- },
- {
- "@id": "urn:nrel_example/nrel00000244"
- },
- {
- "@id": "urn:nrel_example/nrel00000276"
- },
- {
- "@id": "urn:nrel_example/nrel00000311"
- },
- {
- "@id": "urn:nrel_example/nrel00000624"
- },
- {
- "@id": "urn:nrel_example/nrel00000753"
- },
- {
- "@id": "urn:nrel_example/nrel00000943"
- },
- {
- "@id": "urn:nrel_example/nrel00001035"
- },
- {
- "@id": "urn:nrel_example/nrel00001055"
- },
- {
- "@id": "urn:nrel_example/nrel00001309"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001322"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000770"
+ "@value": "nrel00000164"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000136",
+ "@id": "urn:nrel_example/nrel00000431",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000136"
+ "@value": "nrel00000431"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000354",
+ "@id": "urn:nrel_example/nrel00000944",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000354"
+ "@value": "nrel00000944"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000254",
+ "@id": "urn:nrel_example/nrel00000111",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000424"
- },
- {
- "@id": "urn:nrel_example/nrel00001274"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000288"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000617"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000254"
+ "@value": "nrel00000111"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000753",
+ "@id": "urn:nrel_example/nrel00000692",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000753"
+ "@value": "nrel00000692"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001161",
+ "@id": "urn:nrel_example/nrel00000350",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000986"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00001161"
+ "@id": "urn:nrel_example/nrel00000160"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001159",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000225"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001159"
+ "@value": "nrel00000350"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000523",
+ "@id": "urn:nrel_example/nrel00000469",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000523"
+ "@value": "nrel00000469"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000826",
+ "@id": "urn:nrel_example/nrel00000779",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -9886,54 +9641,51 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000826"
+ "@value": "nrel00000779"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000932",
+ "@id": "urn:nrel_example/nrel00000687",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000207"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001086"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000932"
+ "@value": "nrel00000687"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001074",
+ "@id": "urn:nrel_example/nrel00000653",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001074"
+ "@value": "nrel00000653"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001137",
+ "@id": "urn:nrel_example/nrel00000267",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -9942,167 +9694,198 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001137"
+ "@value": "nrel00000267"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000514",
+ "@id": "urn:nrel_example/nrel00000943",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000514"
+ "@value": "nrel00000943"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001141",
+ "@id": "urn:nrel_example/nrel00000612",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001141"
+ "@value": "nrel00000612"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000362",
+ "@id": "urn:nrel_example/nrel00000785",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000830"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000839"
+ "@value": "nrel00000785"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000258",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000459"
},
{
- "@id": "urn:nrel_example/nrel00001176"
+ "@id": "urn:nrel_example/nrel00001007"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000258"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000870",
+ "@type": [
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000714"
+ "@id": "urn:nrel_example/nrel00000901"
},
{
- "@id": "urn:nrel_example/nrel00001020"
+ "@id": "urn:nrel_example/nrel00000975"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000527"
+ "@id": "urn:nrel_example/nrel00000177"
},
{
- "@id": "urn:nrel_example/nrel00000643"
+ "@id": "urn:nrel_example/nrel00000279"
},
{
- "@id": "urn:nrel_example/nrel00000812"
+ "@id": "urn:nrel_example/nrel00000547"
},
{
- "@id": "urn:nrel_example/nrel00001065"
+ "@id": "urn:nrel_example/nrel00000863"
},
{
- "@id": "urn:nrel_example/nrel00001082"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:nrel_example/nrel00000972"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00001045"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00001053"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001175"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001253"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001310"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000362"
+ "@value": "nrel00000870"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000020",
+ "@id": "urn:nrel_example/nrel00001293",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000020"
+ "@value": "nrel00001293"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000856",
+ "@id": "urn:nrel_example/nrel00000243",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000045"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000969"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000610"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000856"
+ "@value": "nrel00000243"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000157",
+ "@id": "urn:nrel_example/nrel00000767",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000157"
+ "@value": "nrel00000767"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000984",
+ "@id": "urn:nrel_example/nrel00000220",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -10113,75 +9896,80 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000984"
+ "@value": "nrel00000220"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000142",
+ "@id": "urn:nrel_example/nrel00000916",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "urn:nrel_example/nrel00000600"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000114"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000641"
+ "@id": "urn:nrel_example/nrel00001059"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000142"
+ "@value": "nrel00000916"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001016",
+ "@id": "urn:nrel_example/nrel00000432",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001016"
+ "@value": "nrel00000432"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000575",
+ "@id": "urn:nrel_example/nrel00000090",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000466"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00001121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000068"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000575"
+ "@value": "nrel00000090"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000539",
+ "@id": "urn:nrel_example/nrel00001091",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -10192,21 +9980,21 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000539"
+ "@value": "nrel00001091"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001143",
+ "@id": "urn:nrel_example/nrel00000759",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000512"
+ "@id": "urn:nrel_example/nrel00000025"
},
{
- "@id": "urn:nrel_example/nrel00001193"
+ "@id": "urn:nrel_example/nrel00000040"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -10216,108 +10004,107 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001143"
+ "@value": "nrel00000759"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000123",
+ "@id": "urn:nrel_example/nrel00000727",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000290"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001091"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000440"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000689"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000123"
+ "@value": "nrel00000727"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001057",
+ "@id": "urn:nrel_example/nrel00000929",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001057"
+ "@value": "nrel00000929"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000810",
+ "@id": "urn:nrel_example/nrel00001047",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000810"
+ "@value": "nrel00001047"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000384",
+ "@id": "urn:nrel_example/nrel00000089",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000384"
+ "@value": "nrel00000089"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000507",
+ "@id": "urn:nrel_example/nrel00000625",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000507"
+ "@value": "nrel00000625"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000457",
+ "@id": "urn:nrel_example/nrel00001306",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -10333,234 +10120,212 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000457"
+ "@value": "nrel00001306"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001279",
+ "@id": "urn:nrel_example/nrel00001263",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Equipment"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001279"
+ "@value": "nrel00001263"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000152",
+ "@id": "urn:nrel_example/nrel00000349",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000823"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000152"
+ "@value": "nrel00000349"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000904",
+ "@id": "urn:nrel_example/nrel00000683",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#HeatExchanger"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000112"
+ "@id": "urn:nrel_example/nrel00000083"
},
{
- "@id": "urn:nrel_example/nrel00000123"
+ "@id": "urn:nrel_example/nrel00000344"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000546"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000248"
+ "@id": "urn:nrel_example/nrel00000183"
},
{
- "@id": "urn:nrel_example/nrel00000874"
+ "@id": "urn:nrel_example/nrel00000189"
},
{
- "@id": "urn:nrel_example/nrel00000973"
+ "@id": "urn:nrel_example/nrel00000271"
},
{
- "@id": "urn:nrel_example/nrel00000996"
+ "@id": "urn:nrel_example/nrel00000923"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000140"
- },
- {
- "@id": "urn:nrel_example/nrel00000298"
+ "@id": "urn:nrel_example/nrel00000067"
},
{
- "@id": "urn:nrel_example/nrel00000330"
+ "@id": "urn:nrel_example/nrel00000163"
},
{
- "@id": "urn:nrel_example/nrel00001239"
- },
+ "@id": "urn:nrel_example/nrel00001094"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00001317"
+ "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000904"
+ "@value": "nrel00000683"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000576",
+ "@id": "urn:nrel_example/nrel00000585",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000576"
+ "@value": "nrel00000585"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001306",
+ "@id": "urn:nrel_example/nrel00001159",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001159"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000732",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001306"
+ "@value": "nrel00000732"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000372",
+ "@id": "urn:nrel_example/nrel00001325",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000893"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000724"
+ },
{
- "@id": "urn:nrel_example/nrel00000553"
+ "@id": "urn:nrel_example/nrel00000802"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000930"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000372"
+ "@value": "nrel00001325"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000853",
+ "@id": "urn:nrel_example/nrel00000795",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000853"
+ "@value": "nrel00000795"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000007",
+ "@id": "urn:nrel_example/nrel00001299",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000383"
- },
- {
- "@id": "urn:nrel_example/nrel00000749"
- },
- {
- "@id": "urn:nrel_example/nrel00001042"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000430"
- },
- {
- "@id": "urn:nrel_example/nrel00000715"
- },
- {
- "@id": "urn:nrel_example/nrel00000903"
- },
- {
- "@id": "urn:nrel_example/nrel00001256"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000795"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000946"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000007"
+ "@value": "nrel00001299"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000882",
+ "@id": "urn:nrel_example/nrel00000508",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -10569,140 +10334,97 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000882"
+ "@value": "nrel00000508"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001232",
+ "@id": "urn:nrel_example/nrel00000428",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000309"
- },
- {
- "@id": "urn:nrel_example/nrel00000602"
- },
- {
- "@id": "urn:nrel_example/nrel00001303"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000000"
- },
- {
- "@id": "urn:nrel_example/nrel00000032"
- },
- {
- "@id": "urn:nrel_example/nrel00000465"
- },
- {
- "@id": "urn:nrel_example/nrel00001284"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000358"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001220"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001232"
+ "@value": "nrel00000428"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000831",
+ "@id": "urn:nrel_example/nrel00000384",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000831"
+ "@value": "nrel00000384"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000916",
+ "@id": "urn:nrel_example/nrel00000976",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000600"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000114"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001059"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000916"
+ "@value": "nrel00000976"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001298",
+ "@id": "urn:nrel_example/nrel00000884",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001298"
+ "@value": "nrel00000884"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000197",
+ "@id": "urn:nrel_example/nrel00001039",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000197"
+ "@value": "nrel00001039"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000212",
+ "@id": "urn:nrel_example/nrel00000565",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -10718,293 +10440,271 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000212"
+ "@value": "nrel00000565"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000721",
+ "@id": "urn:nrel_example/nrel00000407",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000721"
+ "@value": "nrel00000407"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000204",
+ "@id": "urn:nrel_example/nrel00001176",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000137"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000561"
+ },
{
- "@value": "nrel00000204"
+ "@id": "urn:nrel_example/nrel00001095"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001089",
- "@type": [
- "http://data.ashrae.org/standard223#HeatRecoveryCoil"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000351"
+ "@id": "urn:nrel_example/nrel00000625"
},
{
- "@id": "urn:nrel_example/nrel00000618"
+ "@id": "urn:nrel_example/nrel00000668"
},
{
- "@id": "urn:nrel_example/nrel00000821"
+ "@id": "urn:nrel_example/nrel00000810"
},
{
- "@id": "urn:nrel_example/nrel00001304"
+ "@id": "urn:nrel_example/nrel00001102"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000315"
- },
- {
- "@id": "urn:nrel_example/nrel00000368"
- },
- {
- "@id": "urn:nrel_example/nrel00000431"
+ "@id": "urn:nrel_example/nrel00000046"
},
{
- "@id": "urn:nrel_example/nrel00000488"
+ "@id": "urn:nrel_example/nrel00000623"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001089"
+ "@value": "nrel00001176"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000100",
+ "@id": "urn:nrel_example/nrel00000470",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001267"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00001165"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000743"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000100"
+ "@value": "nrel00000470"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000033",
+ "@id": "urn:nrel_example/nrel00000913",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000033"
+ "@value": "nrel00000913"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001134",
+ "@id": "urn:nrel_example/nrel00000820",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001134"
+ "@value": "nrel00000820"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000052",
+ "@id": "urn:nrel_example/nrel00001267",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000186"
+ },
{
- "@value": "nrel00000052"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000447",
- "@type": [
- "http://data.ashrae.org/standard223#HeatRecoveryCoil"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000236"
+ },
{
- "@id": "urn:nrel_example/nrel00000660"
+ "@id": "urn:nrel_example/nrel00000245"
},
{
- "@id": "urn:nrel_example/nrel00000899"
+ "@id": "urn:nrel_example/nrel00000339"
},
{
- "@id": "urn:nrel_example/nrel00001166"
+ "@id": "urn:nrel_example/nrel00000444"
},
{
- "@id": "urn:nrel_example/nrel00001240"
+ "@id": "urn:nrel_example/nrel00000627"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000199"
- },
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00000542"
- },
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000585"
+ "@id": "urn:nrel_example/nrel00000184"
},
{
- "@id": "urn:nrel_example/nrel00001061"
+ "@id": "urn:nrel_example/nrel00000743"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000447"
+ "@value": "nrel00001267"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001146",
+ "@id": "urn:nrel_example/nrel00000154",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001146"
+ "@value": "nrel00000154"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000660",
+ "@id": "urn:nrel_example/nrel00001048",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000660"
+ "@value": "nrel00001048"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000277",
+ "@id": "urn:nrel_example/nrel00000043",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000277"
+ "@value": "nrel00000043"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000504",
+ "@id": "urn:nrel_example/nrel00000736",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000045"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000162"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "nrel00000504"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000970",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001014"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001295"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000970"
+ "@value": "nrel00000736"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000961",
+ "@id": "urn:nrel_example/nrel00000227",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -11013,170 +10713,153 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000961"
+ "@value": "nrel00000227"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001060",
+ "@id": "urn:nrel_example/nrel00000566",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001060"
+ "@value": "nrel00000566"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000329",
+ "@id": "urn:nrel_example/nrel00001041",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000329"
+ "@value": "nrel00001041"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000992",
+ "@id": "urn:nrel_example/nrel00000176",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000211"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000034"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000992"
+ "@value": "nrel00000176"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000732",
+ "@id": "urn:nrel_example/nrel00001206",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000732"
+ "@value": "nrel00001206"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001190",
+ "@id": "urn:nrel_example/nrel00000037",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000389"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000968"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001190"
+ "@value": "nrel00000037"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000662",
+ "@id": "urn:nrel_example/nrel00000812",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000662"
+ "@value": "nrel00000812"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001305",
+ "@id": "urn:nrel_example/nrel00000806",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000399"
- },
- {
- "@id": "urn:nrel_example/nrel00000438"
- },
- {
- "@id": "urn:nrel_example/nrel00000603"
- },
- {
- "@id": "urn:nrel_example/nrel00000640"
- },
- {
- "@id": "urn:nrel_example/nrel00000775"
- },
- {
- "@id": "urn:nrel_example/nrel00000806"
- },
- {
- "@id": "urn:nrel_example/nrel00000924"
- },
- {
- "@id": "urn:nrel_example/nrel00000942"
- },
- {
- "@id": "urn:nrel_example/nrel00000947"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001007"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001068"
- },
+ "@value": "nrel00000806"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000130",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001080"
+ "@id": "urn:nrel_example/nrel00000380"
},
{
- "@id": "urn:nrel_example/nrel00001193"
+ "@id": "urn:nrel_example/nrel00000579"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -11186,214 +10869,191 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001305"
+ "@value": "nrel00000130"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000071",
+ "@id": "urn:nrel_example/nrel00000394",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000071"
+ "@value": "nrel00000394"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001205",
+ "@id": "urn:nrel_example/nrel00000323",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000504"
+ "@id": "urn:nrel_example/nrel00000631"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000241"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000263"
+ "@id": "urn:nrel_example/nrel00000665"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001205"
+ "@value": "nrel00000323"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000518",
+ "@id": "urn:nrel_example/nrel00000083",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000437"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00001104"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000518"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000634",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:nrel_example/nrel00001026"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001252"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000634"
+ "@value": "nrel00000083"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000170",
+ "@id": "urn:nrel_example/nrel00000837",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000170"
+ "@value": "nrel00000837"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001070",
+ "@id": "urn:nrel_example/nrel00000355",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001070"
+ "@value": "nrel00000355"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000611",
+ "@id": "urn:nrel_example/nrel00000531",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000590"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001121"
+ "@id": "urn:nrel_example/nrel00001023"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000009"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000611"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000554",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001138"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000554"
+ "@value": "nrel00000531"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000177",
+ "@id": "urn:nrel_example/nrel00000244",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000177"
+ "@value": "nrel00000244"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001281",
+ "@id": "urn:nrel_example/nrel00000699",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000535"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001281"
+ "@value": "nrel00000699"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000078",
+ "@id": "urn:nrel_example/nrel00000374",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000001"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000219"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -11402,30 +11062,30 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000078"
+ "@value": "nrel00000374"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001210",
+ "@id": "urn:nrel_example/nrel00000269",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001210"
+ "@value": "nrel00000269"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001006",
+ "@id": "urn:nrel_example/nrel00000877",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -11434,218 +11094,232 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001006"
+ "@value": "nrel00000877"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000107",
+ "@id": "urn:nrel_example/nrel00001204",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000875"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000107"
+ "@value": "nrel00001204"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000421",
+ "@id": "urn:nrel_example/nrel00000010",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000814"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001196"
+ "@id": "urn:nrel_example/nrel00000818"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000879"
- },
+ "@id": "urn:nrel_example/nrel00000336"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001097"
+ "@id": "urn:nrel_example/nrel00000739"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000421"
+ "@value": "nrel00000010"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001329",
+ "@id": "urn:nrel_example/nrel00000607",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000207"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000709"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001329"
+ "@value": "nrel00000607"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000892",
+ "@id": "urn:nrel_example/nrel00001228",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000077"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000227"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000892"
+ "@value": "nrel00001228"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001116",
+ "@id": "urn:nrel_example/nrel00001137",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00001267"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001165"
+ "@value": "nrel00001137"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000818",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000184"
+ "@id": "urn:nrel_example/nrel00000221"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001086"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000739"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001130"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001116"
+ "@value": "nrel00000818"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001168",
+ "@id": "urn:nrel_example/nrel00000743",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001168"
+ "@value": "nrel00000743"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001299",
+ "@id": "urn:nrel_example/nrel00001076",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001299"
+ "@value": "nrel00001076"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000104",
+ "@id": "urn:nrel_example/nrel00000160",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000587"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000104"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001117",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000225"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001286"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001117"
+ "@value": "nrel00000160"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000849",
+ "@id": "urn:nrel_example/nrel00000824",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "urn:nrel_example/nrel00000386"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000532"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000048"
+ "@id": "urn:nrel_example/nrel00000410"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001248"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000849"
+ "@value": "nrel00000824"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001238",
+ "@id": "urn:nrel_example/nrel00001109",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -11661,258 +11335,312 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001238"
+ "@value": "nrel00001109"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000877",
+ "@id": "urn:nrel_example/nrel00000904",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000112"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000123"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000877"
+ "@id": "urn:nrel_example/nrel00000248"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000874"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000973"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000996"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000278",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000140"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000298"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000330"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001239"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001317"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000278"
+ "@value": "nrel00000904"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000812",
+ "@id": "urn:nrel_example/nrel00001272",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000812"
+ "@value": "nrel00001272"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001186",
+ "@id": "urn:nrel_example/nrel00000530",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000074"
- },
- {
- "@id": "urn:nrel_example/nrel00001208"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001186"
+ "@value": "nrel00000530"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000450",
+ "@id": "urn:nrel_example/nrel00000368",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000450"
+ "@value": "nrel00000368"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000016",
+ "@id": "urn:nrel_example/nrel00000810",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000810"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001171",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000016"
+ "@value": "nrel00001171"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000453",
+ "@id": "urn:nrel_example/nrel00001158",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000453"
+ "@value": "nrel00001158"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001319",
+ "@id": "urn:nrel_example/nrel00000556",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001319"
+ "@value": "nrel00000556"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000928",
+ "@id": "urn:nrel_example/nrel00000560",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000928"
+ "@value": "nrel00000560"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001029",
+ "@id": "urn:nrel_example/nrel00000366",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000388"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000673"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001029"
+ "@value": "nrel00000366"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001317",
+ "@id": "urn:nrel_example/nrel00000728",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001317"
+ "@value": "nrel00000728"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000466",
+ "@id": "urn:nrel_example/nrel00001089",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#HeatRecoveryCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000351"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000618"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000821"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001304"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000315"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000368"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000431"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000488"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000466"
+ "@value": "nrel00001089"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000641",
+ "@id": "urn:nrel_example/nrel00000710",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000641"
+ "@value": "nrel00000710"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000151",
+ "@id": "urn:nrel_example/nrel00000444",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -11923,150 +11651,144 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000151"
+ "@value": "nrel00000444"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000712",
+ "@id": "urn:nrel_example/nrel00000859",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000080"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000284"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000987"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000712"
+ "@value": "nrel00000859"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001219",
+ "@id": "urn:nrel_example/nrel00000159",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000462"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000924"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001219"
+ "@value": "nrel00000159"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000941",
+ "@id": "urn:nrel_example/nrel00000363",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000251"
- },
- {
- "@id": "urn:nrel_example/nrel00000846"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000404"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000681"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000941"
+ "@value": "nrel00000363"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001266",
+ "@id": "urn:nrel_example/nrel00000923",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000321"
+ "@id": "urn:nrel_example/nrel00000642"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000936"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000067"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001266"
+ "@value": "nrel00000923"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000418",
+ "@id": "urn:nrel_example/nrel00000396",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000485"
+ "@id": "urn:nrel_example/nrel00000278"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000603"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000457"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000418"
+ "@value": "nrel00000396"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000077",
+ "@id": "urn:nrel_example/nrel00000999",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000424"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000892"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000077"
+ "@value": "nrel00000999"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001158",
+ "@id": "urn:nrel_example/nrel00001236",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -12082,355 +11804,325 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001158"
+ "@value": "nrel00001236"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000745",
+ "@id": "urn:nrel_example/nrel00000917",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000948"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000124"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000745"
+ "@value": "nrel00000917"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000727",
+ "@id": "urn:nrel_example/nrel00000576",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000727"
+ "@value": "nrel00000576"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000246",
+ "@id": "urn:nrel_example/nrel00000666",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000649"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000553"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000182"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000246"
+ "@value": "nrel00000666"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000580",
+ "@id": "urn:nrel_example/nrel00000014",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000337"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000741"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001190"
+ "@value": "nrel00000014"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000872",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000229"
- },
- {
- "@id": "urn:nrel_example/nrel00000389"
- },
- {
- "@id": "urn:nrel_example/nrel00000463"
+ "@id": "urn:nrel_example/nrel00001234"
},
{
- "@id": "urn:nrel_example/nrel00000756"
+ "@id": "urn:nrel_example/nrel00001298"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000968"
+ "@id": "urn:nrel_example/nrel00001209"
},
{
- "@id": "urn:nrel_example/nrel00001307"
+ "@id": "urn:nrel_example/nrel00001251"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000580"
+ "@value": "nrel00000872"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000032",
+ "@id": "urn:nrel_example/nrel00000427",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000032"
+ "@value": "nrel00000427"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000500",
+ "@id": "urn:nrel_example/nrel00001020",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
- ],
- "http://data.ashrae.org/standard223#encloses": [
- {
- "@id": "urn:nrel_example/nrel00001125"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000216"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001168"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000500"
+ "@value": "nrel00001020"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000665",
+ "@id": "urn:nrel_example/nrel00001019",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000665"
+ "@value": "nrel00001019"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000647",
+ "@id": "urn:nrel_example/nrel00001037",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000150"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000836"
+ "@id": "urn:nrel_example/nrel00000722"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000052"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000360"
+ "@id": "urn:nrel_example/nrel00000820"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000647"
+ "@value": "nrel00001037"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001274",
+ "@id": "urn:nrel_example/nrel00000168",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001265"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000078"
+ "@id": "urn:nrel_example/nrel00000042"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001274"
+ "@value": "nrel00000168"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000159",
+ "@id": "urn:nrel_example/nrel00000857",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000159"
+ "@value": "nrel00000857"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000369",
+ "@id": "urn:nrel_example/nrel00000908",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000441"
+ "@id": "urn:nrel_example/nrel00000397"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000758"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000369"
+ "@value": "nrel00000908"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000598",
+ "@id": "urn:nrel_example/nrel00001079",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000966"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000282"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000109"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000598"
+ "@value": "nrel00001079"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001115",
+ "@id": "urn:nrel_example/nrel00000511",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000014"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000237"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000102"
- },
- {
- "@id": "urn:nrel_example/nrel00000108"
- },
- {
- "@id": "urn:nrel_example/nrel00000327"
- },
- {
- "@id": "urn:nrel_example/nrel00000338"
- },
- {
- "@id": "urn:nrel_example/nrel00000453"
- },
- {
- "@id": "urn:nrel_example/nrel00000633"
- },
- {
- "@id": "urn:nrel_example/nrel00000732"
- },
- {
- "@id": "urn:nrel_example/nrel00001118"
- },
- {
- "@id": "urn:nrel_example/nrel00001148"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001206"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001115"
+ "@value": "nrel00000511"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001135",
+ "@id": "urn:nrel_example/nrel00000092",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000017"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000275"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001135"
+ "@value": "nrel00000092"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000827",
+ "@id": "urn:nrel_example/nrel00001129",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -12439,49 +12131,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000827"
+ "@value": "nrel00001129"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000673",
+ "@id": "urn:nrel_example/nrel00000937",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000673"
+ "@value": "nrel00000937"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000861",
+ "@id": "urn:nrel_example/nrel00001285",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000207"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000861"
+ "@value": "nrel00001285"
}
]
},
@@ -12507,7 +12199,7 @@
]
},
{
- "@id": "urn:nrel_example/nrel00001104",
+ "@id": "urn:nrel_example/nrel00000069",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -12518,280 +12210,215 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001104"
+ "@value": "nrel00000069"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000538",
+ "@id": "urn:nrel_example/nrel00001218",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000439"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000114"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000477"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000538"
+ "@value": "nrel00001218"
}
]
},
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "@id": "urn:nrel_example/nrel00000747",
"@type": [
- "http://data.ashrae.org/standard223#Class",
- "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
- "http://www.w3.org/ns/shacl#NodeShape"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "EnumerationKind AlarmStatus"
+ "@id": "urn:nrel_example/nrel00001023"
}
],
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ "@id": "urn:nrel_example/nrel00000710"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000747"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001316",
+ "@id": "urn:nrel_example/nrel00000959",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001316"
+ "@value": "nrel00000959"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000262",
+ "@id": "urn:nrel_example/nrel00000486",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000035"
- },
- {
- "@id": "urn:nrel_example/nrel00000505"
- },
- {
- "@id": "urn:nrel_example/nrel00000729"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000597"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000724"
+ "@id": "urn:nrel_example/nrel00001125"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000070"
- },
- {
- "@id": "urn:nrel_example/nrel00000405"
- },
- {
- "@id": "urn:nrel_example/nrel00000551"
- },
- {
- "@id": "urn:nrel_example/nrel00000980"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001011"
+ "@id": "urn:nrel_example/nrel00000500"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00001280"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000262"
+ "@value": "nrel00000486"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000469",
+ "@id": "urn:nrel_example/nrel00001054",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000469"
+ "@value": "nrel00001054"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000064",
+ "@id": "urn:nrel_example/nrel00000936",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000064"
+ "@value": "nrel00000936"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000702",
+ "@id": "urn:nrel_example/nrel00001310",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000702"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000201",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000201"
+ "@value": "nrel00001310"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000133",
+ "@id": "urn:nrel_example/nrel00000465",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000432"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001235"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000133"
+ "@value": "nrel00000465"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000615",
+ "@id": "urn:nrel_example/nrel00000647",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000281"
+ "@id": "urn:nrel_example/nrel00000150"
},
{
- "@id": "urn:nrel_example/nrel00000354"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000836"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000615"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000467",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000052"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000360"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000467"
+ "@value": "nrel00000647"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001077",
+ "@id": "urn:nrel_example/nrel00000157",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000134"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001077"
+ "@value": "nrel00000157"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000000",
+ "@id": "urn:nrel_example/nrel00000393",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -12800,93 +12427,98 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000000"
+ "@value": "nrel00000393"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001276",
+ "@id": "urn:nrel_example/nrel00000568",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000757"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000777"
+ "@id": "urn:nrel_example/nrel00000898"
},
{
- "@id": "urn:nrel_example/nrel00001142"
+ "@id": "urn:nrel_example/nrel00001051"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000100"
+ "@id": "urn:nrel_example/nrel00000197"
},
{
- "@id": "urn:nrel_example/nrel00000873"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000292"
+ },
{
- "@id": "urn:nrel_example/nrel00000141"
+ "@id": "urn:nrel_example/nrel00000402"
},
{
- "@id": "urn:nrel_example/nrel00000382"
+ "@id": "urn:nrel_example/nrel00000636"
},
{
- "@id": "urn:nrel_example/nrel00000711"
+ "@id": "urn:nrel_example/nrel00000697"
},
{
- "@id": "urn:nrel_example/nrel00000765"
+ "@id": "urn:nrel_example/nrel00000832"
},
{
- "@id": "urn:nrel_example/nrel00000959"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
+ "@id": "urn:nrel_example/nrel00000945"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00000981"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00001058"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001106"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001201"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001276"
+ "@value": "nrel00000568"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000965",
+ "@id": "urn:nrel_example/nrel00001006",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000080"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000859"
+ "@value": "nrel00001006"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000452",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000005"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000965"
+ "@value": "nrel00000452"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001025",
+ "@id": "urn:nrel_example/nrel00001036",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -12895,112 +12527,106 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000462"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001025"
+ "@value": "nrel00001036"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001283",
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#Class",
+ "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus",
+ "http://www.w3.org/ns/shacl#NodeShape"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@value": "EnumerationKind FlowStatus"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
{
- "@value": "nrel00001283"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000347",
+ "@id": "urn:nrel_example/nrel00000211",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000347"
+ "@value": "nrel00000211"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000813",
+ "@id": "urn:nrel_example/nrel00001050",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001107"
- },
- {
- "@id": "urn:nrel_example/nrel00001302"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000813"
+ "@value": "nrel00001050"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000968",
+ "@id": "urn:nrel_example/nrel00000987",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000968"
+ "@value": "nrel00000987"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000030",
+ "@id": "urn:nrel_example/nrel00001030",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000030"
+ "@value": "nrel00001030"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000252",
+ "@id": "urn:nrel_example/nrel00000491",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -13009,560 +12635,428 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000252"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000966",
- "@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000059"
- },
- {
- "@id": "urn:nrel_example/nrel00000098"
- },
- {
- "@id": "urn:nrel_example/nrel00000658"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000109"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:nrel_example/nrel00000845"
+ "@id": "urn:nrel_example/nrel00000864"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000966"
+ "@value": "nrel00000491"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000193",
+ "@id": "urn:nrel_example/nrel00001212",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000939"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000708"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000308"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000193"
+ "@value": "nrel00001212"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001039",
+ "@id": "urn:nrel_example/nrel00000757",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000629"
+ },
{
- "@value": "nrel00001039"
+ "@id": "urn:nrel_example/nrel00000872"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001297",
- "@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000084"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000230"
+ "@id": "urn:nrel_example/nrel00000006"
},
{
- "@id": "urn:nrel_example/nrel00000693"
+ "@id": "urn:nrel_example/nrel00000015"
},
{
- "@id": "urn:nrel_example/nrel00000815"
+ "@id": "urn:nrel_example/nrel00000423"
},
{
- "@id": "urn:nrel_example/nrel00000881"
+ "@id": "urn:nrel_example/nrel00001112"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001123"
+ "@id": "urn:nrel_example/nrel00000008"
},
{
- "@id": "urn:nrel_example/nrel00001194"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000545"
+ },
{
- "@id": "urn:nrel_example/nrel00000373"
+ "@id": "urn:nrel_example/nrel00000999"
},
{
- "@id": "urn:nrel_example/nrel00000544"
+ "@id": "urn:nrel_example/nrel00001084"
},
{
- "@id": "urn:nrel_example/nrel00001022"
+ "@id": "urn:nrel_example/nrel00001288"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001297"
+ "@value": "nrel00000757"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000791",
+ "@id": "urn:nrel_example/nrel00001304",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000791"
+ "@value": "nrel00001304"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000919",
+ "@id": "urn:nrel_example/nrel00001167",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000026"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000094"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000919"
+ "@value": "nrel00001167"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000545",
+ "@id": "urn:nrel_example/nrel00000433",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000545"
+ "@value": "nrel00000433"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000991",
+ "@id": "urn:nrel_example/nrel00000459",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00001194"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000991"
+ "@value": "nrel00000459"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001244",
+ "@id": "urn:nrel_example/nrel00000189",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00001244"
+ "@id": "urn:nrel_example/nrel00000163"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001094"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001049",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000211"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001049"
+ "@value": "nrel00000189"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000907",
+ "@id": "urn:nrel_example/nrel00000324",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000043"
- },
- {
- "@id": "urn:nrel_example/nrel00000790"
- },
- {
- "@id": "urn:nrel_example/nrel00001182"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001242"
+ "@id": "urn:nrel_example/nrel00000961"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000064"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000907"
+ "@value": "nrel00000324"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001331",
+ "@id": "urn:nrel_example/nrel00000028",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00001331"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000097",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000097"
+ "@value": "nrel00000028"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000006",
+ "@id": "urn:nrel_example/nrel00001133",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000006"
+ "@value": "nrel00001133"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001285",
+ "@id": "urn:nrel_example/nrel00000730",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000207"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001285"
+ "@value": "nrel00000730"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000072",
+ "@id": "urn:nrel_example/nrel00000475",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000072"
+ "@value": "nrel00000475"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000057",
+ "@id": "urn:nrel_example/nrel00001130",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000057"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001322",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001322"
+ "@value": "nrel00001130"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000505",
+ "@id": "urn:nrel_example/nrel00000725",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000626"
- },
- {
- "@id": "urn:nrel_example/nrel00001071"
- },
- {
- "@id": "urn:nrel_example/nrel00001266"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000321"
- },
- {
- "@id": "urn:nrel_example/nrel00000748"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000983"
+ "@id": "urn:nrel_example/nrel00000441"
},
{
- "@id": "urn:nrel_example/nrel00001117"
+ "@id": "urn:nrel_example/nrel00000590"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000936"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001236"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000505"
+ "@value": "nrel00000725"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001312",
+ "@id": "urn:nrel_example/nrel00000049",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000818"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000336"
+ "@id": "urn:nrel_example/nrel00000165"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001130"
+ "@id": "urn:nrel_example/nrel00000175"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001312"
+ "@value": "nrel00000049"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000473",
+ "@id": "urn:nrel_example/nrel00000245",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000473"
+ "@value": "nrel00000245"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000433",
+ "@id": "urn:nrel_example/nrel00001286",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000433"
+ "@value": "nrel00001286"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001052",
+ "@id": "urn:nrel_example/nrel00000996",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000967"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001052"
+ "@value": "nrel00000996"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000717",
+ "@id": "urn:nrel_example/nrel00001313",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000122"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001027"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001167"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000717"
+ "@value": "nrel00001313"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000393",
+ "@id": "urn:nrel_example/nrel00000271",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -13573,12 +13067,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000393"
+ "@value": "nrel00000271"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000534",
+ "@id": "urn:nrel_example/nrel00000844",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -13594,545 +13088,648 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000534"
+ "@value": "nrel00000844"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000935",
+ "@id": "urn:nrel_example/nrel00000960",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00000192"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000494"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000531"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000747"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001008"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000635"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001023"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000935"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001131",
+ "@id": "urn:nrel_example/nrel00000081"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000710"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001138"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000960"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001141",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000941"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000121"
+ "@value": "nrel00001141"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000425",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000681"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001131"
+ "@value": "nrel00000425"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000263",
+ "@id": "urn:nrel_example/nrel00000706",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000263"
+ "@value": "nrel00000706"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000025",
+ "@id": "urn:nrel_example/nrel00000487",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000025"
+ "@value": "nrel00000487"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001218",
+ "@id": "urn:nrel_example/nrel00000584",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001218"
+ "@value": "nrel00000584"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000321",
+ "@id": "urn:nrel_example/nrel00000862",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000219"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000792"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000417"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001134"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000321"
+ "@value": "nrel00000862"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000178",
+ "@id": "urn:nrel_example/nrel00000905",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000444"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000597"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000178"
+ "@value": "nrel00000905"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000342",
+ "@id": "urn:nrel_example/nrel00000788",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000967"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001221"
+ "@value": "nrel00000788"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000746",
+ "@type": [
+ "http://data.ashrae.org/standard223#EAU",
+ "http://data.ashrae.org/standard223#Equipment"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000343"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000429"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000675"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000771"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001003"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001089"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001100"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001119"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000050"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000134"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000669"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000853"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000342"
+ "@value": "nrel00000746"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000181",
+ "@id": "urn:nrel_example/nrel00000142",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000641"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000181"
+ "@value": "nrel00000142"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000795",
+ "@id": "urn:nrel_example/nrel00000284",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000795"
+ "@value": "nrel00000284"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000499",
+ "@id": "urn:nrel_example/nrel00001307",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000499"
+ "@value": "nrel00001307"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001217",
+ "@id": "urn:nrel_example/nrel00000784",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001217"
+ "@value": "nrel00000784"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000160",
+ "@id": "urn:nrel_example/nrel00000616",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000587"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000225"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001286"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000160"
+ "@value": "nrel00000616"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000045",
+ "@id": "urn:nrel_example/nrel00001222",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000045"
+ "@value": "nrel00001222"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001320",
+ "@id": "urn:nrel_example/nrel00000300",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000792"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000464"
+ "@id": "urn:nrel_example/nrel00001050"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000825"
+ "@id": "urn:nrel_example/nrel00000518"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001320"
+ "@value": "nrel00000300"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001241",
+ "@id": "urn:nrel_example/nrel00001294",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001241"
+ "@value": "nrel00001294"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000630",
+ "@id": "urn:nrel_example/nrel00000152",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000707"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001195"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000353"
- },
- {
- "@id": "urn:nrel_example/nrel00000390"
- },
- {
- "@id": "urn:nrel_example/nrel00001122"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001328"
+ "@id": "urn:nrel_example/nrel00000823"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000303"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000333"
- },
+ "@value": "nrel00000152"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000490",
+ "@type": [
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000534"
+ "@id": "urn:nrel_example/nrel00001020"
},
{
- "@id": "urn:nrel_example/nrel00000993"
- },
+ "@id": "urn:nrel_example/nrel00001200"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001145"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000630"
+ "@value": "nrel00000490"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000352",
+ "@id": "urn:nrel_example/nrel00000255",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000397"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000352"
+ "@value": "nrel00000255"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000430",
+ "@id": "urn:nrel_example/nrel00000755",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000380"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000491"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000473"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000883"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000430"
+ "@value": "nrel00000755"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000213",
+ "@id": "urn:nrel_example/nrel00001193",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000213"
+ "@value": "nrel00001193"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000918",
+ "@id": "urn:nrel_example/nrel00000385",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000918"
+ "@value": "nrel00000385"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000858",
+ "@id": "urn:nrel_example/nrel00001147",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000858"
+ "@value": "nrel00001147"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000299",
+ "@id": "urn:nrel_example/nrel00000682",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000299"
+ "@value": "nrel00000682"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000493",
+ "@id": "urn:nrel_example/nrel00000577",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000587"
+ "@id": "urn:nrel_example/nrel00000891"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000160"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000844"
+ "@id": "urn:nrel_example/nrel00000687"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000493"
+ "@value": "nrel00000577"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001282",
+ "@id": "urn:nrel_example/nrel00000979",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001282"
+ "@value": "nrel00000979"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000764",
+ "@id": "urn:nrel_example/nrel00001166",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00001198"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000764"
+ "@value": "nrel00001166"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000562",
+ "@id": "urn:nrel_example/nrel00000128",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
@@ -14148,73 +13745,62 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000562"
+ "@value": "nrel00000128"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001079",
+ "@id": "urn:nrel_example/nrel00000095",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000966"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000168"
+ },
{
- "@id": "urn:nrel_example/nrel00000282"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000312"
+ },
{
- "@id": "urn:nrel_example/nrel00000109"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000497"
+ },
{
- "@value": "nrel00001079"
+ "@id": "urn:nrel_example/nrel00000608"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000799"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001156",
- "@type": [
- "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000198"
+ "@id": "urn:nrel_example/nrel00000227"
},
{
- "@id": "urn:nrel_example/nrel00000578"
+ "@id": "urn:nrel_example/nrel00001265"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000788"
+ "@id": "urn:nrel_example/nrel00000042"
},
{
- "@id": "urn:nrel_example/nrel00001006"
+ "@id": "urn:nrel_example/nrel00000726"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000809"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001156"
+ "@value": "nrel00000095"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000351",
+ "@id": "urn:nrel_example/nrel00001260",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000172"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -14222,43 +13808,35 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000351"
+ "@value": "nrel00001260"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001211",
+ "@id": "urn:nrel_example/nrel00001095",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000406"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000574"
+ "@id": "urn:nrel_example/nrel00000668"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000046"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001211"
+ "@value": "nrel00001095"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000406",
+ "@id": "urn:nrel_example/nrel00000882",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001211"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14267,49 +13845,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000406"
+ "@value": "nrel00000882"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000603",
+ "@id": "urn:nrel_example/nrel00000494",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001023"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000081"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000603"
+ "@value": "nrel00000494"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001094",
+ "@id": "urn:nrel_example/nrel00000658",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001094"
+ "@value": "nrel00000658"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000775",
+ "@id": "urn:nrel_example/nrel00000808",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -14320,12 +13898,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000775"
+ "@value": "nrel00000808"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000364",
+ "@id": "urn:nrel_example/nrel00000441",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -14336,65 +13914,60 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000364"
+ "@value": "nrel00000441"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000185",
+ "@id": "urn:nrel_example/nrel00000440",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000185"
+ "@value": "nrel00000440"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000143",
+ "@id": "urn:nrel_example/nrel00000742",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000143"
+ "@value": "nrel00000742"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000696",
+ "@id": "urn:nrel_example/nrel00001104",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000696"
+ "@value": "nrel00001104"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000431",
+ "@id": "urn:nrel_example/nrel00000809",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -14410,14 +13983,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000431"
+ "@value": "nrel00000809"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000019",
+ "@id": "urn:nrel_example/nrel00001099",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -14426,210 +13999,264 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000019"
+ "@value": "nrel00001099"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000601",
+ "@id": "urn:nrel_example/nrel00001056",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00001265"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000601"
+ "@value": "nrel00001056"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001332",
+ "@id": "urn:nrel_example/nrel00001258",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000120"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000415"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00000349"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000644"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001332"
+ "@value": "nrel00001258"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000381",
+ "@id": "urn:nrel_example/nrel00000554",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000554"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001297",
+ "@type": [
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000049"
+ "@id": "urn:nrel_example/nrel00000084"
},
{
- "@id": "urn:nrel_example/nrel00000582"
+ "@id": "urn:nrel_example/nrel00000230"
},
{
- "@id": "urn:nrel_example/nrel00000657"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000165"
+ "@id": "urn:nrel_example/nrel00000693"
},
{
- "@id": "urn:nrel_example/nrel00001040"
+ "@id": "urn:nrel_example/nrel00000815"
},
{
- "@id": "urn:nrel_example/nrel00001074"
+ "@id": "urn:nrel_example/nrel00000881"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00001123"
},
{
- "@id": "urn:nrel_example/nrel00001279"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000175"
+ "@id": "urn:nrel_example/nrel00000373"
},
{
- "@id": "urn:nrel_example/nrel00000571"
+ "@id": "urn:nrel_example/nrel00000544"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001022"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000381"
+ "@value": "nrel00001297"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000108",
+ "@id": "urn:nrel_example/nrel00001094",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000108"
+ "@value": "nrel00001094"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000438",
+ "@id": "urn:nrel_example/nrel00000455",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000438"
+ "@value": "nrel00000455"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001106",
+ "@id": "urn:nrel_example/nrel00000149",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "urn:nrel_example/nrel00000211"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000942"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001106"
+ "@value": "nrel00000149"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000645",
+ "@id": "urn:nrel_example/nrel00000555",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000645"
+ "@value": "nrel00000555"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000083",
+ "@id": "urn:nrel_example/nrel00000205",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000437"
+ "@id": "urn:nrel_example/nrel00000025"
},
{
- "@id": "urn:nrel_example/nrel00001104"
+ "@id": "urn:nrel_example/nrel00000076"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001026"
+ "@id": "urn:nrel_example/nrel00000194"
},
{
- "@id": "urn:nrel_example/nrel00001252"
+ "@id": "urn:nrel_example/nrel00000299"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000083"
+ "@value": "nrel00000205"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000392",
+ "@id": "urn:nrel_example/nrel00000703",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000215"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00001108"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000698"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001188"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000392"
+ "@value": "nrel00000703"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001323",
+ "@id": "urn:nrel_example/nrel00000462",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -14640,272 +14267,228 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001323"
+ "@value": "nrel00000462"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000495",
+ "@id": "urn:nrel_example/nrel00000828",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000331"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001111"
+ "@id": "urn:nrel_example/nrel00000251"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000270"
- },
- {
- "@id": "urn:nrel_example/nrel00000476"
- },
- {
- "@id": "urn:nrel_example/nrel00000523"
- },
- {
- "@id": "urn:nrel_example/nrel00000543"
- },
- {
- "@id": "urn:nrel_example/nrel00000706"
- },
- {
- "@id": "urn:nrel_example/nrel00000713"
- },
- {
- "@id": "urn:nrel_example/nrel00000730"
- },
- {
- "@id": "urn:nrel_example/nrel00000819"
- },
- {
- "@id": "urn:nrel_example/nrel00000831"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001000"
- },
+ "@id": "urn:nrel_example/nrel00000121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001039"
+ "@id": "urn:nrel_example/nrel00000071"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000495"
+ "@value": "nrel00000828"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001001",
+ "@id": "urn:nrel_example/nrel00001059",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001001"
+ "@value": "nrel00001059"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001326",
+ "@id": "urn:nrel_example/nrel00001155",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00000985"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001326"
+ "@value": "nrel00001155"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001258",
+ "@id": "urn:nrel_example/nrel00000150",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000120"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000415"
+ "@value": "nrel00000150"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000974",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000349"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000644"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001258"
+ "@value": "nrel00000974"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000223",
+ "@id": "urn:nrel_example/nrel00000399",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000223"
+ "@value": "nrel00000399"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000883",
+ "@id": "urn:nrel_example/nrel00001262",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000883"
+ "@value": "nrel00001262"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001142",
+ "@id": "urn:nrel_example/nrel00000065",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000266"
- },
- {
- "@id": "urn:nrel_example/nrel00000472"
- },
- {
- "@id": "urn:nrel_example/nrel00000934"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000104"
- },
- {
- "@id": "urn:nrel_example/nrel00000620"
- },
- {
- "@id": "urn:nrel_example/nrel00001141"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001241"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000256"
- },
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:nrel_example/nrel00000260"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001142"
+ "@value": "nrel00000065"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000446",
+ "@id": "urn:nrel_example/nrel00000206",
"@type": [
- "http://data.ashrae.org/standard223#Filter"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000255"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000892"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000564"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000446"
+ "@value": "nrel00000206"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000338",
+ "@id": "urn:nrel_example/nrel00000506",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000338"
+ "@value": "nrel00000506"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000801",
+ "@id": "urn:nrel_example/nrel00000316",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000801"
+ "@value": "nrel00000316"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001085",
+ "@id": "urn:nrel_example/nrel00000392",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -14921,90 +14504,86 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001085"
+ "@value": "nrel00000392"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000689",
+ "@id": "urn:nrel_example/nrel00000886",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000689"
+ "@value": "nrel00000886"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000235",
+ "@id": "urn:nrel_example/nrel00000024",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000413"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000887"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00001161"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001311"
+ "@value": "nrel00000024"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000040",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000231"
- },
- {
- "@id": "urn:nrel_example/nrel00000294"
- },
- {
- "@id": "urn:nrel_example/nrel00000575"
- },
- {
- "@id": "urn:nrel_example/nrel00000766"
- },
- {
- "@id": "urn:nrel_example/nrel00000835"
- },
- {
- "@id": "urn:nrel_example/nrel00000951"
- },
- {
- "@id": "urn:nrel_example/nrel00001177"
- },
- {
- "@id": "urn:nrel_example/nrel00001202"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001216"
- },
+ "@value": "nrel00000040"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000418",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001281"
- },
+ "@id": "urn:nrel_example/nrel00000485"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001332"
+ "@id": "urn:nrel_example/nrel00000457"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000235"
+ "@value": "nrel00000418"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000957",
+ "@id": "urn:nrel_example/nrel00000964",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -15015,267 +14594,297 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000957"
+ "@value": "nrel00000964"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000373",
+ "@id": "urn:nrel_example/nrel00000133",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000432"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00001235"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000373"
+ "@value": "nrel00000133"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000274",
+ "@id": "urn:nrel_example/nrel00001255",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000274"
+ "@value": "nrel00001255"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001133",
+ "@id": "urn:nrel_example/nrel00000129",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001133"
+ "@value": "nrel00000129"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000776",
+ "@id": "urn:nrel_example/nrel00001040",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000776"
+ "@value": "nrel00001040"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000688",
+ "@id": "urn:nrel_example/nrel00000167",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000688"
+ "@value": "nrel00000167"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000517",
+ "@id": "urn:nrel_example/nrel00000538",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000307"
- },
+ "@id": "urn:nrel_example/nrel00000439"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000618"
+ "@id": "urn:nrel_example/nrel00000114"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000477"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000517"
+ "@value": "nrel00000538"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001208",
+ "@id": "urn:nrel_example/nrel00000679",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001208"
+ "@value": "nrel00000679"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001078",
+ "@id": "urn:nrel_example/nrel00000863",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001077"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000272"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001078"
+ "@value": "nrel00000863"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000501",
+ "@id": "urn:nrel_example/nrel00000187",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#TerminalUnit"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000236"
+ "@id": "urn:nrel_example/nrel00000205"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000273"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000369"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000925"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001315"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001165"
+ "@id": "urn:nrel_example/nrel00000441"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001047"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000567"
+ "@id": "urn:nrel_example/nrel00000118"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000132"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000758"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000501"
+ "@value": "nrel00000187"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000227",
+ "@id": "urn:nrel_example/nrel00001328",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000227"
+ "@value": "nrel00001328"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000236",
+ "@id": "urn:nrel_example/nrel00000709",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000236"
+ "@value": "nrel00000709"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000425",
+ "@id": "urn:nrel_example/nrel00000855",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000425"
+ "@value": "nrel00000855"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000148",
+ "@id": "urn:nrel_example/nrel00000503",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001046"
+ "@id": "urn:nrel_example/nrel00000649"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000553"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001067"
+ "@id": "urn:nrel_example/nrel00001178"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000148"
+ "@value": "nrel00000503"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000642",
+ "@id": "urn:nrel_example/nrel00000574",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000586"
- },
- {
- "@id": "urn:nrel_example/nrel00000923"
+ "@id": "urn:nrel_example/nrel00001211"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -15285,88 +14894,62 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000642"
+ "@value": "nrel00000574"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001030",
+ "@id": "urn:nrel_example/nrel00000061",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000062"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001199"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00001030"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000437",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000437"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000003",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
+ "@id": "urn:nrel_example/nrel00000240"
+ },
{
- "@id": "urn:nrel_example/nrel00000804"
+ "@id": "urn:nrel_example/nrel00000586"
},
{
- "@id": "urn:nrel_example/nrel00001038"
+ "@id": "urn:nrel_example/nrel00000964"
},
{
- "@id": "urn:nrel_example/nrel00001156"
+ "@id": "urn:nrel_example/nrel00001268"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000612"
+ "@id": "urn:nrel_example/nrel00000498"
},
{
- "@id": "urn:nrel_example/nrel00000676"
+ "@id": "urn:nrel_example/nrel00000529"
},
{
- "@id": "urn:nrel_example/nrel00000897"
+ "@id": "urn:nrel_example/nrel00000718"
},
{
- "@id": "urn:nrel_example/nrel00000953"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000203"
+ "@id": "urn:nrel_example/nrel00001158"
},
{
- "@id": "urn:nrel_example/nrel00000895"
+ "@id": "urn:nrel_example/nrel00001261"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000003"
+ "@value": "nrel00000061"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000852",
+ "@id": "urn:nrel_example/nrel00000353",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -15377,151 +14960,150 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000852"
+ "@value": "nrel00000353"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000785",
+ "@id": "urn:nrel_example/nrel00000763",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000785"
+ "@value": "nrel00000763"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000216",
+ "@id": "urn:nrel_example/nrel00000981",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000216"
+ "@value": "nrel00000981"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000667",
+ "@id": "urn:nrel_example/nrel00000445",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000207"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000443"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000667"
+ "@value": "nrel00000445"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000394",
+ "@id": "urn:nrel_example/nrel00000031",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000840"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000858"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000268"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000598"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000394"
+ "@value": "nrel00000031"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000194",
+ "@id": "urn:nrel_example/nrel00000620",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000194"
+ "@value": "nrel00000620"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000126",
+ "@id": "urn:nrel_example/nrel00000841",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000126"
+ "@value": "nrel00000841"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000772",
+ "@id": "urn:nrel_example/nrel00001043",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000167"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000978"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000772"
+ "@value": "nrel00001043"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001020",
+ "@id": "urn:nrel_example/nrel00001101",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000806"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000864"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -15530,280 +15112,398 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001020"
+ "@value": "nrel00001101"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000943",
+ "@id": "urn:nrel_example/nrel00000664",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000943"
+ "@value": "nrel00000664"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001007",
+ "@id": "urn:nrel_example/nrel00000070",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000070"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000178",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001007"
+ "@value": "nrel00000178"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000080",
+ "@id": "urn:nrel_example/nrel00000035",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000220"
+ "@id": "urn:nrel_example/nrel00000522"
},
{
- "@id": "urn:nrel_example/nrel00001105"
+ "@id": "urn:nrel_example/nrel00000824"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000317"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000685"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000808"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000976"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000005"
+ "@id": "urn:nrel_example/nrel00000028"
},
{
- "@id": "urn:nrel_example/nrel00000319"
+ "@id": "urn:nrel_example/nrel00000085"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000243"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000253"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000994"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000080"
+ "@value": "nrel00000035"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001111",
+ "@id": "urn:nrel_example/nrel00000173",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001111"
+ "@value": "nrel00000173"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000408",
+ "@id": "urn:nrel_example/nrel00000751",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000138"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000241"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001283"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000408"
+ "@value": "nrel00000751"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001250",
+ "@id": "urn:nrel_example/nrel00000771",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Filter"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000307"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000699"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000154"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001250"
+ "@value": "nrel00000771"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001277",
+ "@id": "urn:nrel_example/nrel00000137",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001080"
- },
+ "@id": "urn:nrel_example/nrel00000810"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001123"
+ "@id": "urn:nrel_example/nrel00000623"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000137"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000621",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001277"
+ "@value": "nrel00000621"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001124",
+ "@id": "urn:nrel_example/nrel00000821",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001124"
+ "@value": "nrel00000821"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001324",
+ "@id": "urn:nrel_example/nrel00000921",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000921"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000453",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001324"
+ "@value": "nrel00000453"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000390",
+ "@id": "urn:nrel_example/nrel00001160",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000390"
+ "@value": "nrel00001160"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000974",
+ "@id": "urn:nrel_example/nrel00000600",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000439"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001049"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000847"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001059"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000600"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000156",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000974"
+ "@value": "nrel00000156"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000724",
+ "@id": "urn:nrel_example/nrel00001300",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000724"
+ "@value": "nrel00001300"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001126",
+ "@id": "urn:nrel_example/nrel00000537",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001126"
+ "@value": "nrel00000537"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000222",
+ "@id": "urn:nrel_example/nrel00000017",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000222"
+ "@value": "nrel00000017"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000256",
+ "@id": "urn:nrel_example/nrel00000260",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -15819,313 +15519,239 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000256"
+ "@value": "nrel00000260"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000038",
+ "@id": "urn:nrel_example/nrel00000533",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000495"
+ "@id": "urn:nrel_example/nrel00000188"
},
{
- "@id": "urn:nrel_example/nrel00000780"
+ "@id": "urn:nrel_example/nrel00000418"
},
{
- "@id": "urn:nrel_example/nrel00001187"
+ "@id": "urn:nrel_example/nrel00001012"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000420"
- },
- {
- "@id": "urn:nrel_example/nrel00001270"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000173"
- },
- {
- "@id": "urn:nrel_example/nrel00000212"
+ "@id": "urn:nrel_example/nrel00000485"
},
{
- "@id": "urn:nrel_example/nrel00000228"
+ "@id": "urn:nrel_example/nrel00000579"
},
{
- "@id": "urn:nrel_example/nrel00000329"
+ "@id": "urn:nrel_example/nrel00001285"
},
{
- "@id": "urn:nrel_example/nrel00000884"
+ "@id": "urn:nrel_example/nrel00001299"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ "@id": "urn:nrel_example/nrel00000166"
},
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00000457"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000038"
+ "@value": "nrel00000533"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000241",
+ "@id": "urn:nrel_example/nrel00001168",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000631"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000274"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001283"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000241"
+ "@value": "nrel00001168"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000455",
+ "@id": "urn:nrel_example/nrel00000292",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000455"
+ "@value": "nrel00000292"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000054",
+ "@id": "urn:nrel_example/nrel00000109",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000054"
+ "@value": "nrel00000109"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000365",
+ "@id": "urn:nrel_example/nrel00000186",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000580"
- },
- {
- "@id": "urn:nrel_example/nrel00000630"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001174"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000001"
- },
- {
- "@id": "urn:nrel_example/nrel00000459"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000157"
- },
- {
- "@id": "urn:nrel_example/nrel00000425"
- },
- {
- "@id": "urn:nrel_example/nrel00000672"
- },
- {
- "@id": "urn:nrel_example/nrel00001109"
- },
- {
- "@id": "urn:nrel_example/nrel00001314"
- }
- ],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
- {
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000365"
+ "@value": "nrel00000186"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000591",
+ "@id": "urn:nrel_example/nrel00001291",
"@type": [
"http://data.ashrae.org/standard223#HeatingCoil"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000039"
+ "@id": "urn:nrel_example/nrel00000421"
},
{
- "@id": "urn:nrel_example/nrel00000416"
+ "@id": "urn:nrel_example/nrel00000919"
},
{
- "@id": "urn:nrel_example/nrel00000604"
+ "@id": "urn:nrel_example/nrel00001029"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000200"
+ "@id": "urn:nrel_example/nrel00000026"
},
{
- "@id": "urn:nrel_example/nrel00000306"
+ "@id": "urn:nrel_example/nrel00000082"
},
{
- "@id": "urn:nrel_example/nrel00001136"
+ "@id": "urn:nrel_example/nrel00000388"
},
{
- "@id": "urn:nrel_example/nrel00001226"
+ "@id": "urn:nrel_example/nrel00000785"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000933"
+ "@id": "urn:nrel_example/nrel00000094"
},
{
- "@id": "urn:nrel_example/nrel00001255"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000591"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000428",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000673"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000428"
+ "@value": "nrel00001291"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000383",
+ "@id": "urn:nrel_example/nrel00000968",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000430"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000795"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000383"
+ "@value": "nrel00000968"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000234",
+ "@id": "urn:nrel_example/nrel00000144",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000234"
+ "@value": "nrel00000144"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000951",
+ "@id": "urn:nrel_example/nrel00000761",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000951"
+ "@value": "nrel00000761"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000158",
+ "@id": "urn:nrel_example/nrel00001182",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000891"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -16134,881 +15760,842 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000158"
+ "@value": "nrel00001182"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000023",
+ "@id": "urn:nrel_example/nrel00000318",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000023"
+ "@value": "nrel00000318"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000090",
+ "@id": "urn:nrel_example/nrel00000074",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000466"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001121"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000068"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000090"
+ "@value": "nrel00000074"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000862",
+ "@id": "urn:nrel_example/nrel00000547",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000219"
- },
- {
- "@id": "urn:nrel_example/nrel00000792"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000417"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001134"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000862"
+ "@value": "nrel00000547"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000817",
+ "@id": "urn:nrel_example/nrel00001248",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001072"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000684"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000817"
+ "@value": "nrel00001248"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000316",
+ "@id": "urn:nrel_example/nrel00000387",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000316"
+ "@value": "nrel00000387"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000219",
+ "@id": "urn:nrel_example/nrel00000860",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000219"
+ "@value": "nrel00000860"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000276",
+ "@id": "urn:nrel_example/nrel00000591",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000039"
+ },
{
- "@id": "http://qudt.org/vocab/unit/HZ"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000416"
+ },
{
- "@value": "nrel00000276"
+ "@id": "urn:nrel_example/nrel00000604"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000396",
- "@type": [
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000278"
+ "@id": "urn:nrel_example/nrel00000200"
},
{
- "@id": "urn:nrel_example/nrel00000603"
+ "@id": "urn:nrel_example/nrel00000306"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001136"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001226"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000933"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001255"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000396"
+ "@value": "nrel00000591"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001236",
+ "@id": "urn:nrel_example/nrel00000233",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000226"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000568"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001291"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000512"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001208"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000115"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000348"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000451"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001002"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001212"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001236"
+ "@value": "nrel00000233"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000444",
+ "@id": "urn:nrel_example/nrel00001010",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000444"
+ "@value": "nrel00001010"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000751",
+ "@id": "urn:nrel_example/nrel00001259",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000138"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@value": "nrel00001259"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001105",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001283"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000751"
+ "@value": "nrel00001105"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000322",
+ "@id": "urn:nrel_example/nrel00000080",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001259"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000220"
+ },
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@id": "urn:nrel_example/nrel00001105"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00001168"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000322"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000679",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:nrel_example/nrel00000005"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000319"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000679"
+ "@value": "nrel00000080"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000476",
+ "@id": "urn:nrel_example/nrel00000139",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000476"
+ "@value": "nrel00000139"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001304",
+ "@id": "urn:nrel_example/nrel00000263",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00001304"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000921",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000921"
+ "@value": "nrel00000263"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001160",
+ "@id": "urn:nrel_example/nrel00000378",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:nrel_example/nrel00000220"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00001160"
+ "@id": "urn:nrel_example/nrel00000859"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000198",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000284"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000198"
+ "@value": "nrel00000378"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000757",
+ "@id": "urn:nrel_example/nrel00000235",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000629"
+ "@id": "urn:nrel_example/nrel00000413"
},
{
- "@id": "urn:nrel_example/nrel00000872"
+ "@id": "urn:nrel_example/nrel00000887"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000006"
+ "@id": "urn:nrel_example/nrel00001161"
},
{
- "@id": "urn:nrel_example/nrel00000015"
+ "@id": "urn:nrel_example/nrel00001311"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000231"
},
{
- "@id": "urn:nrel_example/nrel00000423"
+ "@id": "urn:nrel_example/nrel00000294"
},
{
- "@id": "urn:nrel_example/nrel00001112"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000575"
+ },
{
- "@id": "urn:nrel_example/nrel00000008"
+ "@id": "urn:nrel_example/nrel00000766"
},
{
- "@id": "urn:nrel_example/nrel00000545"
+ "@id": "urn:nrel_example/nrel00000835"
},
{
- "@id": "urn:nrel_example/nrel00000999"
+ "@id": "urn:nrel_example/nrel00000951"
},
{
- "@id": "urn:nrel_example/nrel00001084"
+ "@id": "urn:nrel_example/nrel00001177"
},
{
- "@id": "urn:nrel_example/nrel00001288"
+ "@id": "urn:nrel_example/nrel00001202"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001216"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001281"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001332"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000757"
+ "@value": "nrel00000235"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000652",
+ "@id": "urn:nrel_example/nrel00000893",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001197"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001121"
+ "@value": "nrel00000893"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000931",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000499"
+ "@id": "urn:nrel_example/nrel00000678"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@value": "nrel00000652"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
- ]
- },
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Default",
- "@type": [
- "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
- "http://data.ashrae.org/standard223#EnumerationKind-Override"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@language": "en",
- "@value": "AlarmStatus-Alarm"
- },
- {
- "@language": "en",
- "@value": "Override-Default"
+ "@value": "nrel00000931"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000478",
+ "@id": "urn:nrel_example/nrel00000286",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000474"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000708"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000345"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000478"
+ "@value": "nrel00000286"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000924",
+ "@id": "urn:nrel_example/nrel00001113",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000043"
+ },
{
- "@value": "nrel00000924"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000388",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000790"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000802"
+ },
{
- "@value": "nrel00000388"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000675",
- "@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000841"
+ },
{
- "@id": "urn:nrel_example/nrel00000574"
+ "@id": "urn:nrel_example/nrel00001182"
},
{
- "@id": "urn:nrel_example/nrel00000691"
+ "@id": "urn:nrel_example/nrel00001203"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001242"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000347"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001153"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000675"
+ "@value": "nrel00001113"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001150",
+ "@id": "urn:nrel_example/nrel00001173",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001150"
+ "@value": "nrel00001173"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000155",
+ "@id": "urn:nrel_example/nrel00000088",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000862"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000464"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000417"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000986"
+ },
{
- "@value": "nrel00000155"
+ "@id": "urn:nrel_example/nrel00001194"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000840",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000840"
+ "@value": "nrel00000088"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001222",
+ "@id": "urn:nrel_example/nrel00000097",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001222"
+ "@value": "nrel00000097"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001098",
+ "@id": "urn:nrel_example/nrel00000091",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001098"
+ "@value": "nrel00000091"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000654",
+ "@id": "urn:nrel_example/nrel00000209",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000099"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000135"
+ },
{
- "@value": "nrel00000654"
+ "@id": "urn:nrel_example/nrel00000904"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000613",
- "@type": [
- "http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000093"
+ "@id": "urn:nrel_example/nrel00000131"
},
{
- "@id": "urn:nrel_example/nrel00000894"
+ "@id": "urn:nrel_example/nrel00000355"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000952"
+ "@id": "urn:nrel_example/nrel00000392"
},
{
- "@id": "urn:nrel_example/nrel00001088"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000752"
+ },
{
- "@value": "nrel00000613"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000002",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00000805"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00001160"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001233"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000002"
+ "@value": "nrel00000209"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001179",
+ "@id": "urn:nrel_example/nrel00000162",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001179"
+ "@value": "nrel00000162"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000203",
+ "@id": "urn:nrel_example/nrel00000690",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000203"
+ "@value": "nrel00000690"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000687",
+ "@id": "urn:nrel_example/nrel00000479",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000687"
+ "@value": "nrel00000479"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000889",
+ "@id": "urn:nrel_example/nrel00001156",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000198"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000578"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000788"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001006"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000889"
+ "@value": "nrel00001156"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000012",
+ "@id": "urn:nrel_example/nrel00000861",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000012"
+ "@value": "nrel00000861"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000521",
+ "@id": "urn:nrel_example/nrel00000957",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000354"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000139"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000521"
+ "@value": "nrel00000957"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001110",
+ "@id": "urn:nrel_example/nrel00000522",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00000801"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000957"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00000057"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000144"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000267"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000341"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000352"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000507"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000520"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000900"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001005"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001245"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001110"
+ "@value": "nrel00000522"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000632",
+ "@id": "urn:nrel_example/nrel00001314",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000632"
+ "@value": "nrel00001314"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000355",
+ "@id": "urn:nrel_example/nrel00001049",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -17017,209 +16604,171 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000355"
+ "@value": "nrel00001049"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000912",
+ "@id": "urn:nrel_example/nrel00000101",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000736"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000912"
+ "@id": "urn:nrel_example/nrel00000969"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000279",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00001014"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000279"
+ "@value": "nrel00000101"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001245",
+ "@id": "urn:nrel_example/nrel00000147",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001245"
+ "@value": "nrel00000147"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000701",
+ "@id": "urn:nrel_example/nrel00000337",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001025"
+ "@id": "urn:nrel_example/nrel00000469"
},
{
- "@id": "urn:nrel_example/nrel00001203"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000509"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000701"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001123",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000119"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000671"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001123"
+ "@value": "nrel00000337"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000822",
+ "@id": "urn:nrel_example/nrel00001093",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000355"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000438"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000822"
+ "@value": "nrel00001093"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001032",
+ "@id": "urn:nrel_example/nrel00001197",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000466"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000590"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "nrel00001032"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001050",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000499"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001306"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001050"
+ "@value": "nrel00001197"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000205",
+ "@id": "urn:nrel_example/nrel00000011",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000025"
- },
- {
- "@id": "urn:nrel_example/nrel00000076"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000194"
- },
- {
- "@id": "urn:nrel_example/nrel00000299"
- }
+ "http://www.w3.org/2002/07/owl#Ontology"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000205"
+ "@value": "nrel00000011"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000637",
+ "@id": "urn:nrel_example/nrel00001035",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000637"
+ "@value": "nrel00001035"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001307",
+ "@id": "urn:nrel_example/nrel00001061",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -17235,33 +16784,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001307"
+ "@value": "nrel00001061"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000124",
+ "@id": "urn:nrel_example/nrel00000919",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00000026"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000094"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000124"
+ "@value": "nrel00000919"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000315",
+ "@id": "urn:nrel_example/nrel00000046",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -17277,264 +16826,300 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000315"
+ "@value": "nrel00000046"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000976",
+ "@id": "urn:nrel_example/nrel00000741",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000463"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001307"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000976"
+ "@value": "nrel00000741"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000643",
+ "@id": "urn:nrel_example/nrel00000421",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000814"
+ },
{
- "@value": "nrel00000643"
+ "@id": "urn:nrel_example/nrel00001196"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000305",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000879"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001097"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000305"
+ "@value": "nrel00000421"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001058",
+ "@id": "urn:nrel_example/nrel00000224",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001058"
+ "@value": "nrel00000224"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001080",
+ "@id": "urn:nrel_example/nrel00000853",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001080"
+ "@value": "nrel00000853"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000192",
+ "@id": "urn:nrel_example/nrel00001174",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000971"
+ "@id": "urn:nrel_example/nrel00000588"
},
{
- "@id": "urn:nrel_example/nrel00001169"
+ "@id": "urn:nrel_example/nrel00001294"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001060"
+ "@id": "urn:nrel_example/nrel00000020"
},
{
- "@id": "urn:nrel_example/nrel00001327"
+ "@id": "urn:nrel_example/nrel00000029"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000257"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000295"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000569"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000650"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000796"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000857"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000890"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001076"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001154"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000192"
+ "@value": "nrel00001174"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000069",
+ "@id": "urn:nrel_example/nrel00000606",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000069"
+ "@value": "nrel00000606"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000093",
+ "@id": "urn:nrel_example/nrel00001311",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000093"
+ "@value": "nrel00001311"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000360",
+ "@id": "urn:nrel_example/nrel00001114",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001086"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000336"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000471"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000360"
+ "@value": "nrel00001114"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000600",
+ "@id": "urn:nrel_example/nrel00000158",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000439"
- },
- {
- "@id": "urn:nrel_example/nrel00001049"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000891"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000847"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001059"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000600"
+ "@value": "nrel00000158"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000015",
+ "@id": "urn:nrel_example/nrel00001082",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000015"
+ "@value": "nrel00001082"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000334",
+ "@id": "urn:nrel_example/nrel00001175",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000587"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000160"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000433"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000334"
+ "@value": "nrel00001175"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000563",
+ "@id": "urn:nrel_example/nrel00000677",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000208"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000563"
+ "@value": "nrel00000677"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000760",
+ "@id": "urn:nrel_example/nrel00000846",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -17543,12 +17128,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000760"
+ "@value": "nrel00000846"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001062",
+ "@id": "urn:nrel_example/nrel00000165",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -17559,169 +17144,130 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001062"
+ "@value": "nrel00000165"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001270",
+ "@id": "urn:nrel_example/nrel00001298",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001270"
+ "@value": "nrel00001298"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000736",
+ "@id": "urn:nrel_example/nrel00000365",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000045"
+ "@id": "urn:nrel_example/nrel00000580"
},
{
- "@id": "urn:nrel_example/nrel00000162"
+ "@id": "urn:nrel_example/nrel00000630"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001174"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000001"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000459"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00001014"
+ "@id": "urn:nrel_example/nrel00000157"
},
{
- "@id": "urn:nrel_example/nrel00001295"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000425"
+ },
{
- "@value": "nrel00000736"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000749",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "urn:nrel_example/nrel00000672"
+ },
{
- "@id": "urn:nrel_example/nrel00000715"
+ "@id": "urn:nrel_example/nrel00001109"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001314"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00000946"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000749"
+ "@value": "nrel00000365"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000344",
+ "@id": "urn:nrel_example/nrel00000155",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000944"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001210"
+ "@id": "urn:nrel_example/nrel00000862"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000145"
- },
- {
- "@id": "urn:nrel_example/nrel00000170"
- },
- {
- "@id": "urn:nrel_example/nrel00000174"
- },
- {
- "@id": "urn:nrel_example/nrel00000384"
- },
- {
- "@id": "urn:nrel_example/nrel00000456"
- },
- {
- "@id": "urn:nrel_example/nrel00000468"
- },
- {
- "@id": "urn:nrel_example/nrel00000937"
- },
- {
- "@id": "urn:nrel_example/nrel00001081"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001120"
- },
+ "@id": "urn:nrel_example/nrel00000464"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001246"
+ "@id": "urn:nrel_example/nrel00000417"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000344"
+ "@value": "nrel00000155"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000752",
+ "@id": "urn:nrel_example/nrel00000141",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000752"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001327",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001327"
+ "@value": "nrel00000141"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001090",
+ "@id": "urn:nrel_example/nrel00001067",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -17737,143 +17283,126 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001090"
+ "@value": "nrel00001067"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000573",
+ "@id": "urn:nrel_example/nrel00000966",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000941"
+ "@id": "urn:nrel_example/nrel00000059"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000098"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000658"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00000121"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000404"
+ "@id": "urn:nrel_example/nrel00000109"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000845"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000573"
+ "@value": "nrel00000966"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000709",
+ "@id": "urn:nrel_example/nrel00001253",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000709"
+ "@value": "nrel00001253"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000378",
+ "@id": "urn:nrel_example/nrel00001163",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000220"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000859"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000284"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000378"
+ "@value": "nrel00001163"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001170",
+ "@id": "urn:nrel_example/nrel00001122",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001170"
+ "@value": "nrel00001122"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000253",
+ "@id": "urn:nrel_example/nrel00000283",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000253"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000497",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001265"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000726"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000497"
+ "@value": "nrel00000283"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000221",
+ "@id": "urn:nrel_example/nrel00000588",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -17884,63 +17413,84 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000221"
+ "@value": "nrel00000588"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000328",
+ "@id": "urn:nrel_example/nrel00000791",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000306"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001262"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000328"
+ "@value": "nrel00000791"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001162",
+ "@id": "urn:nrel_example/nrel00000629",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000069"
+ "@id": "urn:nrel_example/nrel00000318"
},
{
- "@id": "urn:nrel_example/nrel00000482"
+ "@id": "urn:nrel_example/nrel00000393"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000111"
+ "@id": "urn:nrel_example/nrel00000105"
},
{
- "@id": "urn:nrel_example/nrel00001319"
+ "@id": "urn:nrel_example/nrel00000128"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000218"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000398"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000519"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000528"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000540"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000548"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000702"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001140"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001162"
+ "@value": "nrel00000629"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000147",
+ "@id": "urn:nrel_example/nrel00001085",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -17956,14 +17506,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000147"
+ "@value": "nrel00001085"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000716",
+ "@id": "urn:nrel_example/nrel00000047",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -17972,38 +17522,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000716"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000759",
- "@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000025"
- },
- {
- "@id": "urn:nrel_example/nrel00000040"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000759"
+ "@value": "nrel00000047"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001182",
+ "@id": "urn:nrel_example/nrel00000760",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18012,114 +17538,110 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001182"
+ "@value": "nrel00000760"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000550",
+ "@id": "urn:nrel_example/nrel00000765",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000550"
+ "@value": "nrel00000765"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001164",
+ "@id": "urn:nrel_example/nrel00000502",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000846"
+ },
{
- "@value": "nrel00001164"
+ "@id": "urn:nrel_example/nrel00000948"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000037",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000037"
+ "@value": "nrel00000502"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000275",
+ "@id": "urn:nrel_example/nrel00000708",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000939"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000345"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000866"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000275"
+ "@value": "nrel00000708"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000242",
+ "@id": "urn:nrel_example/nrel00000628",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000677"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001262"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00000632"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000716"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000242"
+ "@value": "nrel00000628"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000903",
+ "@id": "urn:nrel_example/nrel00000104",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000589"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18128,93 +17650,144 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000903"
+ "@value": "nrel00000104"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000931",
+ "@id": "urn:nrel_example/nrel00000226",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000678"
+ "@id": "urn:nrel_example/nrel00000031"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000371"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000063"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000269"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000663"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001316"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000204"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000213"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000557"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000803"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001293"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000931"
+ "@value": "nrel00000226"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000556",
+ "@id": "urn:nrel_example/nrel00000262",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000035"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000505"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000729"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000597"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000724"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000556"
+ "@id": "urn:nrel_example/nrel00000070"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000405"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000551"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000980"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001011"
}
- ]
- },
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override",
- "@type": [
- "http://data.ashrae.org/standard223#Class",
- "http://data.ashrae.org/standard223#EnumerationKind-Override",
- "http://www.w3.org/ns/shacl#NodeShape"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@value": "EnumerationKind Override"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind"
+ "@value": "nrel00000262"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001149",
+ "@id": "urn:nrel_example/nrel00000593",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000087"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000434"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000742"
+ "@id": "urn:nrel_example/nrel00000301"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001215"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001149"
+ "@value": "nrel00000593"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001215",
+ "@id": "urn:nrel_example/nrel00001081",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -18225,252 +17798,249 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001215"
+ "@value": "nrel00001081"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001166",
+ "@id": "urn:nrel_example/nrel00000867",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "urn:nrel_example/nrel00001198"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000080"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000122"
+ },
{
- "@value": "nrel00001166"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000535",
- "@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
+ "@id": "urn:nrel_example/nrel00000587"
+ },
{
- "@id": "urn:nrel_example/nrel00000691"
+ "@id": "urn:nrel_example/nrel00000600"
},
{
- "@id": "urn:nrel_example/nrel00000699"
- }
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000631"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000736"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000862"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001125"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001197"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001267"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000535"
+ "@value": "nrel00000867"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001248",
+ "@id": "urn:nrel_example/nrel00000002",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00001248"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001026",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001026"
+ "@value": "nrel00000002"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000559",
+ "@id": "urn:nrel_example/nrel00000684",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000559"
+ "@value": "nrel00000684"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000096",
+ "@id": "urn:nrel_example/nrel00000281",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000096"
+ "@value": "nrel00000281"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000743",
+ "@id": "urn:nrel_example/nrel00001321",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000265"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000876"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000743"
+ "@value": "nrel00001321"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001225",
+ "@id": "urn:nrel_example/nrel00000039",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00001225"
+ "@id": "urn:nrel_example/nrel00001226"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000074",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000933"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000074"
+ "@value": "nrel00000039"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000780",
+ "@id": "urn:nrel_example/nrel00001100",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#HeatExchanger"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000179"
+ "@id": "urn:nrel_example/nrel00000449"
},
{
- "@id": "urn:nrel_example/nrel00001015"
+ "@id": "urn:nrel_example/nrel00001258"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001263"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000525"
+ "@id": "urn:nrel_example/nrel00000261"
},
{
- "@id": "urn:nrel_example/nrel00000826"
+ "@id": "urn:nrel_example/nrel00000554"
},
{
- "@id": "urn:nrel_example/nrel00001043"
+ "@id": "urn:nrel_example/nrel00000577"
},
{
- "@id": "urn:nrel_example/nrel00001063"
+ "@id": "urn:nrel_example/nrel00001180"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000191"
+ "@id": "urn:nrel_example/nrel00000687"
},
{
- "@id": "urn:nrel_example/nrel00000394"
+ "@id": "urn:nrel_example/nrel00000885"
},
{
- "@id": "urn:nrel_example/nrel00000556"
- },
+ "@id": "urn:nrel_example/nrel00001179"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00000592"
- },
+ "@id": "http://data.ashrae.org/standard223#Role-Evaporator"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001001"
+ "@value": "nrel00001100"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001302",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000780"
+ "@value": "nrel00001302"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000009",
+ "@id": "urn:nrel_example/nrel00000212",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000009"
+ "@value": "nrel00000212"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000850",
+ "@id": "urn:nrel_example/nrel00000952",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -18479,408 +18049,394 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000850"
+ "@value": "nrel00000952"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001199",
+ "@id": "urn:nrel_example/nrel00000992",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000096"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001032"
+ "@id": "urn:nrel_example/nrel00000211"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000056"
- },
- {
- "@id": "urn:nrel_example/nrel00000242"
- },
- {
- "@id": "urn:nrel_example/nrel00000277"
- },
- {
- "@id": "urn:nrel_example/nrel00000289"
- },
- {
- "@id": "urn:nrel_example/nrel00000452"
- },
- {
- "@id": "urn:nrel_example/nrel00000559"
- },
- {
- "@id": "urn:nrel_example/nrel00000929"
- },
- {
- "@id": "urn:nrel_example/nrel00001028"
- },
- {
- "@id": "urn:nrel_example/nrel00001066"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001224"
+ "@id": "urn:nrel_example/nrel00000034"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001199"
+ "@value": "nrel00000992"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001311",
+ "@id": "urn:nrel_example/nrel00000264",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001311"
+ "@value": "nrel00000264"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000884",
+ "@id": "urn:nrel_example/nrel00000317",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000884"
+ "@value": "nrel00000317"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001259",
+ "@id": "urn:nrel_example/nrel00000499",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@value": "nrel00001259"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000499"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000735",
+ "@id": "urn:nrel_example/nrel00000390",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000735"
+ "@value": "nrel00000390"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000288",
+ "@id": "urn:nrel_example/nrel00000865",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000288"
+ "@value": "nrel00000865"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001151",
+ "@id": "urn:nrel_example/nrel00000792",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001151"
+ "@value": "nrel00000792"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000666",
+ "@id": "urn:nrel_example/nrel00000476",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000666"
+ "@value": "nrel00000476"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001212",
+ "@id": "urn:nrel_example/nrel00001151",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001212"
+ "@value": "nrel00001151"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000323",
+ "@id": "urn:nrel_example/nrel00000122",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000631"
+ "@id": "urn:nrel_example/nrel00000074"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000781"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000665"
+ "@id": "urn:nrel_example/nrel00000335"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001167"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000323"
+ "@value": "nrel00000122"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000051",
+ "@id": "urn:nrel_example/nrel00000984",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000051"
+ "@value": "nrel00000984"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000899",
+ "@id": "urn:nrel_example/nrel00000345",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000875"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000899"
+ "@value": "nrel00000345"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000677",
+ "@id": "urn:nrel_example/nrel00000989",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "@id": "urn:nrel_example/nrel00000649"
+ },
{
- "@id": "urn:nrel_example/nrel00000208"
+ "@id": "urn:nrel_example/nrel00000818"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000939"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000941"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000677"
+ "@value": "nrel00000989"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001005",
+ "@id": "urn:nrel_example/nrel00000613",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000093"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000894"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000952"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001088"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001005"
+ "@value": "nrel00000613"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001284",
+ "@id": "urn:nrel_example/nrel00000422",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001284"
+ "@value": "nrel00000422"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000895",
+ "@id": "urn:nrel_example/nrel00000624",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000895"
+ "@value": "nrel00000624"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001129",
+ "@id": "urn:nrel_example/nrel00000695",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001129"
+ "@value": "nrel00000695"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000165",
+ "@id": "urn:nrel_example/nrel00000401",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000165"
+ "@value": "nrel00000401"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000975",
+ "@id": "urn:nrel_example/nrel00001208",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000975"
+ "@value": "nrel00001208"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000742",
+ "@id": "urn:nrel_example/nrel00000903",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000589"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18889,79 +18445,72 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000742"
+ "@value": "nrel00000903"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000295",
+ "@id": "urn:nrel_example/nrel00001209",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@value": "nrel00001209"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001270",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000295"
+ "@value": "nrel00001270"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000533",
+ "@id": "urn:nrel_example/nrel00000367",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000188"
- },
- {
- "@id": "urn:nrel_example/nrel00000418"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001012"
+ "@id": "urn:nrel_example/nrel00000219"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000485"
- },
- {
- "@id": "urn:nrel_example/nrel00000579"
- },
- {
- "@id": "urn:nrel_example/nrel00001285"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001299"
+ "@id": "urn:nrel_example/nrel00000464"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000166"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000457"
+ "@id": "urn:nrel_example/nrel00000956"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000533"
+ "@value": "nrel00000367"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000640",
+ "@id": "urn:nrel_example/nrel00001144",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -18970,141 +18519,126 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000640"
+ "@value": "nrel00001144"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000926",
+ "@id": "urn:nrel_example/nrel00000900",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000926"
+ "@value": "nrel00000900"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000502",
+ "@id": "urn:nrel_example/nrel00001064",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000846"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@value": "nrel00001064"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001264",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000502"
+ "@value": "nrel00001264"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001042",
+ "@id": "urn:nrel_example/nrel00000214",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000530"
+ "@id": "urn:nrel_example/nrel00000408"
},
{
- "@id": "urn:nrel_example/nrel00000834"
+ "@id": "urn:nrel_example/nrel00000526"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000606"
+ "@id": "urn:nrel_example/nrel00000395"
},
{
- "@id": "urn:nrel_example/nrel00001124"
+ "@id": "urn:nrel_example/nrel00001170"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001042"
+ "@value": "nrel00000214"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001202",
+ "@id": "urn:nrel_example/nrel00000668",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001202"
+ "@value": "nrel00000668"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000460",
+ "@id": "urn:nrel_example/nrel00001139",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000300"
- },
- {
- "@id": "urn:nrel_example/nrel00000817"
- },
- {
- "@id": "urn:nrel_example/nrel00001162"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000065"
- },
- {
- "@id": "urn:nrel_example/nrel00001050"
- },
- {
- "@id": "urn:nrel_example/nrel00001072"
- },
- {
- "@id": "urn:nrel_example/nrel00001107"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000518"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000684"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000460"
+ "@value": "nrel00001139"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000339",
+ "@id": "urn:nrel_example/nrel00000603",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -19113,195 +18647,193 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000339"
+ "@value": "nrel00000603"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001033",
+ "@id": "urn:nrel_example/nrel00000573",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000941"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001123"
+ "@id": "urn:nrel_example/nrel00000121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000404"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001033"
+ "@value": "nrel00000573"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001101",
+ "@id": "urn:nrel_example/nrel00000836",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000806"
- },
- {
- "@id": "urn:nrel_example/nrel00000864"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001101"
+ "@value": "nrel00000836"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001009",
+ "@id": "urn:nrel_example/nrel00000032",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001009"
+ "@value": "nrel00000032"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000750",
+ "@id": "urn:nrel_example/nrel00000834",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000750"
+ "@value": "nrel00000834"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000028",
+ "@id": "urn:nrel_example/nrel00000273",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000214"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000293"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000920"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000040"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000638"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000720"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001069"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000412"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000419"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000028"
+ "@value": "nrel00000273"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000952",
+ "@id": "urn:nrel_example/nrel00000408",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000952"
+ "@value": "nrel00000408"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000805",
+ "@id": "urn:nrel_example/nrel00000787",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000080"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000859"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000319"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000805"
+ "@value": "nrel00000787"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001196",
+ "@id": "urn:nrel_example/nrel00001078",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001077"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@value": "nrel00001196"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000872",
- "@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00001234"
- },
- {
- "@id": "urn:nrel_example/nrel00001298"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00001209"
- },
- {
- "@id": "urn:nrel_example/nrel00001251"
+ "@id": "urn:nrel_example/nrel00000272"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000872"
+ "@value": "nrel00001078"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000987",
+ "@id": "urn:nrel_example/nrel00000068",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -19317,187 +18849,145 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000987"
+ "@value": "nrel00000068"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000240",
+ "@id": "urn:nrel_example/nrel00000311",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000589"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000240"
+ "@value": "nrel00000311"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000386",
+ "@id": "urn:nrel_example/nrel00000257",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000386"
+ "@value": "nrel00000257"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000870",
+ "@id": "urn:nrel_example/nrel00000519",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000901"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000975"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000177"
- },
- {
- "@id": "urn:nrel_example/nrel00000279"
- },
- {
- "@id": "urn:nrel_example/nrel00000547"
- },
- {
- "@id": "urn:nrel_example/nrel00000863"
- },
- {
- "@id": "urn:nrel_example/nrel00000972"
- },
- {
- "@id": "urn:nrel_example/nrel00001045"
- },
- {
- "@id": "urn:nrel_example/nrel00001053"
- },
- {
- "@id": "urn:nrel_example/nrel00001175"
- },
- {
- "@id": "urn:nrel_example/nrel00001253"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001310"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000870"
- }
- ]
- },
- {
- "@id": "http://data.ashrae.org/standard223#HeatRecoveryCoil",
- "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
- {
- "@id": "http://data.ashrae.org/standard223#Coil"
+ "@value": "nrel00000519"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001087",
+ "@id": "urn:nrel_example/nrel00001116",
"@type": [
- "http://data.ashrae.org/standard223#Filter"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000107"
- },
+ "@id": "urn:nrel_example/nrel00001267"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000908"
+ "@id": "urn:nrel_example/nrel00001165"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001213"
+ "@id": "urn:nrel_example/nrel00000184"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001087"
+ "@value": "nrel00001116"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001256",
+ "@id": "urn:nrel_example/nrel00000199",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000678"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001256"
+ "@value": "nrel00000199"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001144",
+ "@id": "urn:nrel_example/nrel00000656",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000736"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00001144"
+ "@id": "urn:nrel_example/nrel00000969"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000898",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001295"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000898"
+ "@value": "nrel00000656"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000004",
+ "@id": "urn:nrel_example/nrel00000539",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -19506,105 +18996,85 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000004"
+ "@value": "nrel00000539"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000266",
+ "@id": "urn:nrel_example/nrel00000587",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000620"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000745"
+ },
{
- "@id": "urn:nrel_example/nrel00000260"
+ "@id": "urn:nrel_example/nrel00000986"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "nrel00000266"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000106",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000433"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000844"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000106"
+ "@value": "nrel00000587"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000655",
+ "@id": "urn:nrel_example/nrel00000597",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
- {
- "@id": "urn:nrel_example/nrel00000688"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000655"
+ "@value": "nrel00000597"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000247",
+ "@id": "urn:nrel_example/nrel00000437",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001105"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000859"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000987"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000247"
+ "@value": "nrel00000437"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001321",
+ "@id": "urn:nrel_example/nrel00000171",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000265"
+ "@id": "urn:nrel_example/nrel00000098"
},
{
- "@id": "urn:nrel_example/nrel00000876"
+ "@id": "urn:nrel_example/nrel00001207"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -19614,176 +19084,207 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001321"
+ "@value": "nrel00000171"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000933",
+ "@id": "urn:nrel_example/nrel00000970",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000933"
+ "@value": "nrel00000970"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000793",
+ "@id": "urn:nrel_example/nrel00001025",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000793"
+ "@value": "nrel00001025"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001125",
+ "@id": "urn:nrel_example/nrel00000099",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001064"
+ "@id": "urn:nrel_example/nrel00000297"
},
{
- "@id": "urn:nrel_example/nrel00001259"
- }
- ],
- "http://data.ashrae.org/standard223#hasDomain": [
- {
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "urn:nrel_example/nrel00000541"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000002"
+ "@id": "urn:nrel_example/nrel00000036"
},
{
- "@id": "urn:nrel_example/nrel00001280"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000181"
+ },
{
- "@value": "nrel00001125"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000925",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "urn:nrel_example/nrel00000210"
+ },
{
- "@id": "urn:nrel_example/nrel00000441"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000259"
+ },
{
- "@id": "urn:nrel_example/nrel00000118"
+ "@id": "urn:nrel_example/nrel00000304"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000375"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000609"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000690"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000744"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000954"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001147"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000925"
+ "@value": "nrel00000099"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001010",
+ "@id": "urn:nrel_example/nrel00000310",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001010"
+ "@value": "nrel00000310"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001280",
+ "@id": "urn:nrel_example/nrel00000272",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001280"
+ "@value": "nrel00000272"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001207",
+ "@id": "urn:nrel_example/nrel00000410",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001207"
+ "@value": "nrel00000410"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000239",
+ "@id": "urn:nrel_example/nrel00000344",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000944"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001210"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00000145"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000170"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000174"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000384"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000456"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000468"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000937"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001081"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001120"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001246"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000239"
+ "@value": "nrel00000344"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001147",
+ "@id": "urn:nrel_example/nrel00000558",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
@@ -19794,656 +19295,613 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001147"
+ "@value": "nrel00000558"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000577",
+ "@id": "urn:nrel_example/nrel00000331",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000891"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000687"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000577"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000353",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000353"
+ "@value": "nrel00000331"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000835",
+ "@id": "urn:nrel_example/nrel00000895",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000835"
+ "@value": "nrel00000895"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000586",
+ "@id": "urn:nrel_example/nrel00000797",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000642"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001023"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000586"
+ "@value": "nrel00000797"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001189",
+ "@id": "urn:nrel_example/nrel00000955",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001189"
+ "@value": "nrel00000955"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000510",
+ "@id": "urn:nrel_example/nrel00000527",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000475"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000510"
+ "@value": "nrel00000527"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001165",
+ "@id": "urn:nrel_example/nrel00000419",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001267"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000567"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000637"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001165"
+ "@value": "nrel00000419"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001148",
+ "@id": "urn:nrel_example/nrel00000712",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001148"
+ "@value": "nrel00000712"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001269",
+ "@id": "urn:nrel_example/nrel00000096",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001269"
+ "@value": "nrel00000096"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001291",
+ "@id": "urn:nrel_example/nrel00000059",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000421"
- },
- {
- "@id": "urn:nrel_example/nrel00000919"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001029"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000026"
- },
+ "@value": "nrel00000059"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001189",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000082"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000388"
- },
+ "@value": "nrel00001189"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000723",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000785"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000094"
- },
+ "@value": "nrel00000723"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000954",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000673"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001291"
+ "@value": "nrel00000954"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000250",
+ "@id": "urn:nrel_example/nrel00000887",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "urn:nrel_example/nrel00001311"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "urn:nrel_example/nrel00000575"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000250"
+ "@value": "nrel00000887"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001152",
+ "@id": "urn:nrel_example/nrel00000126",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001152"
+ "@value": "nrel00000126"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000131",
+ "@id": "urn:nrel_example/nrel00000468",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000131"
+ "@value": "nrel00000468"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000508",
+ "@id": "urn:nrel_example/nrel00000686",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000967"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000176"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000508"
+ "@value": "nrel00000686"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000733",
+ "@id": "urn:nrel_example/nrel00001003",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000949"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001057"
+ "@id": "urn:nrel_example/nrel00000050"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000357"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001017"
+ "@id": "urn:nrel_example/nrel00000853"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000733"
+ "@value": "nrel00001003"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001254",
+ "@id": "urn:nrel_example/nrel00000726",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000342"
- },
- {
- "@id": "urn:nrel_example/nrel00000524"
- },
- {
- "@id": "urn:nrel_example/nrel00000686"
- },
- {
- "@id": "urn:nrel_example/nrel00000782"
- },
- {
- "@id": "urn:nrel_example/nrel00001231"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000688"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000967"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000176"
- },
- {
- "@id": "urn:nrel_example/nrel00000865"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001221"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001254"
+ "@value": "nrel00000726"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000196",
+ "@id": "urn:nrel_example/nrel00001021",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000186"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001301"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000196"
+ "@value": "nrel00001021"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000590",
+ "@id": "urn:nrel_example/nrel00000279",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000590"
+ "@value": "nrel00000279"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000308",
+ "@id": "urn:nrel_example/nrel00000618",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000517"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000308"
+ "@value": "nrel00000618"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001127",
+ "@id": "urn:nrel_example/nrel00001250",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001127"
+ "@value": "nrel00001250"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000248",
+ "@id": "urn:nrel_example/nrel00000201",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000248"
+ "@value": "nrel00000201"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000963",
+ "@id": "urn:nrel_example/nrel00001134",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000963"
+ "@value": "nrel00001134"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000175",
+ "@id": "urn:nrel_example/nrel00000012",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000175"
+ "@value": "nrel00000012"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000377",
+ "@id": "urn:nrel_example/nrel00000193",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000939"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000708"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000308"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000377"
+ "@value": "nrel00000193"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000906",
+ "@id": "urn:nrel_example/nrel00001112",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000827"
- },
- {
- "@id": "urn:nrel_example/nrel00000852"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000422"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000855"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000906"
+ "@value": "nrel00001112"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000726",
+ "@id": "urn:nrel_example/nrel00000319",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000726"
+ "@value": "nrel00000319"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000811",
+ "@id": "urn:nrel_example/nrel00000021",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "urn:nrel_example/nrel00000339"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "urn:nrel_example/nrel00001165"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000637"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000811"
+ "@value": "nrel00000021"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001118",
+ "@id": "urn:nrel_example/nrel00001125",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00001064"
+ },
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00001259"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "nrel00001118"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000728",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000002"
+ },
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00001280"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000728"
+ "@value": "nrel00001125"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000908",
+ "@id": "urn:nrel_example/nrel00001096",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000397"
+ "@id": "urn:nrel_example/nrel00000265"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000876"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001135"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20453,49 +19911,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000908"
+ "@value": "nrel00001096"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000606",
+ "@id": "urn:nrel_example/nrel00000420",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000606"
+ "@value": "nrel00000420"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001167",
+ "@id": "urn:nrel_example/nrel00001000",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001167"
+ "@value": "nrel00001000"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001287",
+ "@id": "urn:nrel_example/nrel00001220",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -20511,7 +19969,7 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001287"
+ "@value": "nrel00001220"
}
]
},
@@ -20532,102 +19990,66 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000784",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000784"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000402",
+ "@id": "urn:nrel_example/nrel00000315",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000402"
+ "@value": "nrel00000315"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001252",
+ "@id": "urn:nrel_example/nrel00000649",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000364"
+ },
{
- "@value": "nrel00001252"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000174",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00000516"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000893"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00001139"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@value": "nrel00000174"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000543",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000182"
+ },
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00001178"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000543"
+ "@value": "nrel00000649"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001294",
+ "@id": "urn:nrel_example/nrel00001149",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -20636,139 +20058,97 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000742"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001294"
+ "@value": "nrel00001149"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000693",
+ "@id": "urn:nrel_example/nrel00000112",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001194"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000407"
+ },
{
- "@id": "urn:nrel_example/nrel00000373"
+ "@id": "urn:nrel_example/nrel00000621"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000693"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001128",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00000316"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000455"
+ },
{
- "@id": "http://qudt.org/vocab/unit/V"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000506"
+ },
{
- "@value": "nrel00001128"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000694",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:nrel_example/nrel00000536"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000583"
+ },
{
- "@value": "nrel00000694"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001022",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00000666"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000721"
+ },
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000764"
+ },
{
- "@value": "nrel00001022"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000267",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "@id": "urn:nrel_example/nrel00000851"
+ },
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001103"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000267"
+ "@value": "nrel00000112"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000292",
+ "@id": "urn:nrel_example/nrel00000804",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000612"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000895"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000292"
+ "@value": "nrel00000804"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001278",
+ "@id": "urn:nrel_example/nrel00000586",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001260"
- },
- {
- "@id": "urn:nrel_example/nrel00001311"
+ "@id": "urn:nrel_example/nrel00000642"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -20778,191 +20158,162 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001278"
+ "@value": "nrel00000586"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000902",
+ "@id": "urn:nrel_example/nrel00000561",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000100"
+ "@id": "urn:nrel_example/nrel00000448"
},
{
- "@id": "urn:nrel_example/nrel00000775"
+ "@id": "urn:nrel_example/nrel00000921"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000106"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001054"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000902"
+ "@value": "nrel00000561"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000937",
+ "@id": "urn:nrel_example/nrel00000241",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000631"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000937"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001018",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "@id": "urn:nrel_example/nrel00000274"
+ },
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00001283"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001018"
+ "@value": "nrel00000241"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000463",
+ "@id": "urn:nrel_example/nrel00000634",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000463"
+ "@value": "nrel00000634"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000368",
+ "@id": "urn:nrel_example/nrel00000194",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000368"
+ "@value": "nrel00000194"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000597",
+ "@id": "urn:nrel_example/nrel00000449",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000784"
+ },
{
- "@value": "nrel00000597"
+ "@id": "urn:nrel_example/nrel00001129"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001187",
- "@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000733"
+ "@id": "urn:nrel_example/nrel00000224"
},
{
- "@id": "urn:nrel_example/nrel00001181"
+ "@id": "urn:nrel_example/nrel00000387"
},
{
- "@id": "urn:nrel_example/nrel00001205"
- }
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "@id": "urn:nrel_example/nrel00000458"
+ },
{
- "@id": "urn:nrel_example/nrel00000504"
+ "@id": "urn:nrel_example/nrel00000664"
},
{
- "@id": "urn:nrel_example/nrel00000595"
+ "@id": "urn:nrel_example/nrel00000692"
},
{
- "@id": "urn:nrel_example/nrel00000705"
+ "@id": "urn:nrel_example/nrel00000750"
},
{
- "@id": "urn:nrel_example/nrel00000737"
- }
- ],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "@id": "urn:nrel_example/nrel00000871"
+ },
{
- "@id": "urn:nrel_example/nrel00000263"
+ "@id": "urn:nrel_example/nrel00001222"
},
{
- "@id": "urn:nrel_example/nrel00000915"
+ "@id": "urn:nrel_example/nrel00001289"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001326"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001187"
+ "@value": "nrel00000449"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000710",
+ "@id": "urn:nrel_example/nrel00000598",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000710"
+ "@value": "nrel00000598"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000738",
+ "@id": "urn:nrel_example/nrel00000673",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -20978,33 +20329,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000738"
+ "@value": "nrel00000673"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000929",
+ "@id": "urn:nrel_example/nrel00000559",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000929"
+ "@value": "nrel00000559"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000302",
+ "@id": "urn:nrel_example/nrel00000430",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -21015,110 +20366,123 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000302"
+ "@value": "nrel00000430"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000708",
+ "@id": "urn:nrel_example/nrel00000029",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000939"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000345"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000866"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000708"
+ "@value": "nrel00000029"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000297",
+ "@id": "urn:nrel_example/nrel00001038",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000676"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000203"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000297"
+ "@value": "nrel00001038"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000385",
+ "@id": "urn:nrel_example/nrel00000734",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000075"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000740"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000385"
+ "@value": "nrel00000734"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001221",
+ "@id": "urn:nrel_example/nrel00000207",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001221"
+ "@value": "nrel00000207"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001012",
+ "@id": "urn:nrel_example/nrel00000986",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001299"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000166"
+ "@value": "nrel00000986"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000826",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001012"
+ "@value": "nrel00000826"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000303",
+ "@id": "urn:nrel_example/nrel00000175",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -21134,185 +20498,189 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000303"
+ "@value": "nrel00000175"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000525",
+ "@id": "urn:nrel_example/nrel00000177",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000525"
+ "@value": "nrel00000177"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001193",
+ "@id": "urn:nrel_example/nrel00001315",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@value": "nrel00001193"
+ "@id": "urn:nrel_example/nrel00000441"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000186",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000132"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000186"
+ "@value": "nrel00001315"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000707",
+ "@id": "urn:nrel_example/nrel00000362",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000735"
+ "@id": "urn:nrel_example/nrel00000830"
},
{
- "@id": "urn:nrel_example/nrel00001172"
+ "@id": "urn:nrel_example/nrel00000839"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001176"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000086"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000089"
+ "@id": "urn:nrel_example/nrel00000714"
},
{
- "@id": "urn:nrel_example/nrel00000129"
- },
+ "@id": "urn:nrel_example/nrel00001020"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000326"
+ "@id": "urn:nrel_example/nrel00000527"
},
{
- "@id": "urn:nrel_example/nrel00000513"
+ "@id": "urn:nrel_example/nrel00000643"
},
{
- "@id": "urn:nrel_example/nrel00000659"
+ "@id": "urn:nrel_example/nrel00000812"
},
{
- "@id": "urn:nrel_example/nrel00000728"
+ "@id": "urn:nrel_example/nrel00001065"
},
{
- "@id": "urn:nrel_example/nrel00001098"
- },
+ "@id": "urn:nrel_example/nrel00001082"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00001110"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
},
{
- "@id": "urn:nrel_example/nrel00001237"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000707"
+ "@value": "nrel00000362"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000644",
+ "@id": "urn:nrel_example/nrel00001028",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000644"
+ "@value": "nrel00001028"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000208",
+ "@id": "urn:nrel_example/nrel00000249",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000208"
+ "@value": "nrel00000249"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000477",
+ "@id": "urn:nrel_example/nrel00000405",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000477"
+ "@value": "nrel00000405"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000029",
+ "@id": "urn:nrel_example/nrel00000115",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@value": "nrel00000115"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001244",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000029"
+ "@value": "nrel00001244"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000537",
+ "@id": "urn:nrel_example/nrel00000216",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -21328,138 +20696,238 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000537"
+ "@value": "nrel00000216"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000923",
+ "@id": "urn:nrel_example/nrel00000939",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000642"
+ "@id": "urn:nrel_example/nrel00000281"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000474"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomain": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000067"
+ "@id": "urn:nrel_example/nrel00000308"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001090"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000923"
+ "@value": "nrel00000939"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000486",
+ "@id": "urn:nrel_example/nrel00001191",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001125"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000500"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001280"
+ "@value": "nrel00001191"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000839",
+ "@type": [
+ "http://data.ashrae.org/standard223#CoolingCoil"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00001092"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001115"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000356"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000508"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001062"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001189"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000125"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000552"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000654"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001126"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001247"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000486"
+ "@value": "nrel00000839"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000218",
+ "@id": "urn:nrel_example/nrel00000496",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "urn:nrel_example/nrel00000970"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00001272"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000218"
+ "@value": "nrel00000496"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000686",
+ "@id": "urn:nrel_example/nrel00000400",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000967"
+ "@id": "urn:nrel_example/nrel00000305"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000176"
+ "@id": "urn:nrel_example/nrel00000738"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000686"
+ "@value": "nrel00000400"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000481",
+ "@id": "urn:nrel_example/nrel00000505",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "urn:nrel_example/nrel00000626"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001071"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001266"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000321"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000748"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000983"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001117"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000936"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001236"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000481"
+ "@value": "nrel00000505"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000237",
+ "@id": "urn:nrel_example/nrel00001117",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000237"
+ "@value": "nrel00001117"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000443",
+ "@id": "urn:nrel_example/nrel00000472",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00001241"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000256"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000472"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000545",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -21475,54 +20943,76 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000443"
+ "@value": "nrel00000545"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000255",
+ "@id": "urn:nrel_example/nrel00001042",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000397"
+ "@id": "urn:nrel_example/nrel00000530"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000834"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000606"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001124"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000255"
+ "@value": "nrel00001042"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000125",
+ "@id": "urn:nrel_example/nrel00000562",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000125"
+ "@value": "nrel00000562"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000999",
+ "@id": "urn:nrel_example/nrel00001032",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001032"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000552",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -21538,14 +21028,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000999"
+ "@value": "nrel00000552"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001268",
+ "@id": "urn:nrel_example/nrel00000852",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -21554,58 +21044,55 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001268"
+ "@value": "nrel00000852"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000018",
+ "@id": "urn:nrel_example/nrel00000223",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000018"
+ "@value": "nrel00000223"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000217",
+ "@id": "urn:nrel_example/nrel00000991",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000161"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:nrel_example/nrel00000565"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000217"
+ "@value": "nrel00000991"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000397",
+ "@id": "urn:nrel_example/nrel00000461",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000255"
- },
- {
- "@id": "urn:nrel_example/nrel00000908"
+ "@id": "urn:nrel_example/nrel00001198"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -21615,412 +21102,442 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000397"
+ "@value": "nrel00000461"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000129",
+ "@id": "urn:nrel_example/nrel00000858",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000129"
+ "@value": "nrel00000858"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001083",
+ "@id": "urn:nrel_example/nrel00000622",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001083"
+ "@value": "nrel00000622"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000552",
+ "@id": "urn:nrel_example/nrel00000995",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000131"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001259"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000552"
+ "@value": "nrel00000995"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000483",
+ "@id": "urn:nrel_example/nrel00001194",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000862"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000464"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001134"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000483"
+ "@value": "nrel00001194"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000341",
+ "@id": "urn:nrel_example/nrel00000076",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "urn:nrel_example/nrel00001047"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000341"
+ "@value": "nrel00000076"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000946",
+ "@id": "urn:nrel_example/nrel00000889",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000946"
+ "@value": "nrel00000889"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000587",
+ "@id": "urn:nrel_example/nrel00001198",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000745"
+ "@id": "urn:nrel_example/nrel00000461"
},
{
- "@id": "urn:nrel_example/nrel00000986"
+ "@id": "urn:nrel_example/nrel00001166"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000433"
- },
+ "@value": "nrel00001198"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000386",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000844"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000587"
+ "@value": "nrel00000386"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000479",
+ "@id": "urn:nrel_example/nrel00000276",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000479"
+ "@value": "nrel00000276"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000122",
+ "@id": "urn:nrel_example/nrel00000196",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000074"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000781"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@value": "nrel00000196"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000309",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000335"
- },
+ "@id": "urn:nrel_example/nrel00000000"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001167"
+ "@id": "urn:nrel_example/nrel00001220"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000122"
+ "@value": "nrel00000309"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000983",
+ "@id": "urn:nrel_example/nrel00001018",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000983"
+ "@value": "nrel00001018"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000960",
+ "@id": "urn:nrel_example/nrel00001249",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000192"
- },
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000494"
- },
+ "@value": "nrel00001249"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000381",
+ "@type": [
+ "http://data.ashrae.org/standard223#HeatingCoil"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000531"
+ "@id": "urn:nrel_example/nrel00000049"
},
{
- "@id": "urn:nrel_example/nrel00000747"
+ "@id": "urn:nrel_example/nrel00000582"
},
{
- "@id": "urn:nrel_example/nrel00001008"
+ "@id": "urn:nrel_example/nrel00000657"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000635"
+ "@id": "urn:nrel_example/nrel00000165"
},
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@id": "urn:nrel_example/nrel00001040"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001074"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001279"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000081"
- },
- {
- "@id": "urn:nrel_example/nrel00000710"
+ "@id": "urn:nrel_example/nrel00000175"
},
{
- "@id": "urn:nrel_example/nrel00001138"
+ "@id": "urn:nrel_example/nrel00000571"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000960"
+ "@value": "nrel00000381"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001293",
+ "@id": "urn:nrel_example/nrel00000388",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001293"
+ "@value": "nrel00000388"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000842",
+ "@id": "urn:nrel_example/nrel00000696",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000939"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000708"
+ "@value": "nrel00000696"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000504",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001090"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000842"
+ "@value": "nrel00000504"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001113",
+ "@id": "urn:nrel_example/nrel00000321",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000043"
- },
- {
- "@id": "urn:nrel_example/nrel00000790"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000802"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000841"
- },
+ "@value": "nrel00000321"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000054",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001182"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001203"
- },
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001242"
+ "@value": "nrel00000054"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001241",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001113"
+ "@value": "nrel00001241"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000896",
+ "@id": "urn:nrel_example/nrel00000001",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001049"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000114"
+ "@value": "nrel00000001"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000352",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000594"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000896"
+ "@value": "nrel00000352"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000549",
+ "@id": "urn:nrel_example/nrel00000328",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000050"
+ "@id": "urn:nrel_example/nrel00000306"
},
{
- "@id": "urn:nrel_example/nrel00000760"
+ "@id": "urn:nrel_example/nrel00001262"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -22030,352 +21547,337 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000549"
+ "@value": "nrel00000328"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000183",
+ "@id": "urn:nrel_example/nrel00000528",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000183"
+ "@value": "nrel00000528"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001265",
+ "@id": "urn:nrel_example/nrel00000360",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001265"
+ "@value": "nrel00000360"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000890",
+ "@id": "urn:nrel_example/nrel00000972",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000890"
+ "@value": "nrel00000972"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001103",
+ "@id": "urn:nrel_example/nrel00000665",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001103"
+ "@value": "nrel00000665"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000789",
+ "@id": "urn:nrel_example/nrel00000878",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000361"
- },
- {
- "@id": "urn:nrel_example/nrel00000381"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000770"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00001025"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001301"
+ "@value": "nrel00000878"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001256",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000442"
- },
- {
- "@id": "urn:nrel_example/nrel00000481"
- },
- {
- "@id": "urn:nrel_example/nrel00000918"
- },
- {
- "@id": "urn:nrel_example/nrel00001238"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001324"
+ "@id": "urn:nrel_example/nrel00000678"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000789"
+ "@value": "nrel00001256"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000269",
+ "@id": "urn:nrel_example/nrel00001012",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001299"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000166"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000269"
+ "@value": "nrel00001012"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000516",
+ "@id": "urn:nrel_example/nrel00001221",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000516"
+ "@value": "nrel00001221"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000452",
+ "@id": "urn:nrel_example/nrel00001128",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000452"
+ "@value": "nrel00001128"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001172",
+ "@id": "urn:nrel_example/nrel00001269",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001172"
+ "@value": "nrel00001269"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000900",
+ "@id": "urn:nrel_example/nrel00000766",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000900"
+ "@value": "nrel00000766"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000909",
+ "@id": "urn:nrel_example/nrel00000754",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Pump"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000658"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000376"
+ },
{
- "@id": "urn:nrel_example/nrel00000282"
+ "@id": "urn:nrel_example/nrel00000712"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000091"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000044"
+ },
{
- "@value": "nrel00000909"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000350",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "urn:nrel_example/nrel00000180"
+ },
{
- "@id": "urn:nrel_example/nrel00000986"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000310"
+ },
{
- "@id": "urn:nrel_example/nrel00000160"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000370"
+ },
{
- "@id": "urn:nrel_example/nrel00000225"
+ "@id": "urn:nrel_example/nrel00000377"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000639"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000868"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000997"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001010"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001257"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000350"
+ "@value": "nrel00000754"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001072",
+ "@id": "urn:nrel_example/nrel00001083",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00001072"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000468",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000468"
+ "@value": "nrel00001083"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000604",
+ "@id": "urn:nrel_example/nrel00001179",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001136"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001255"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000604"
+ "@value": "nrel00001179"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000243",
+ "@id": "urn:nrel_example/nrel00000962",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000243"
+ "@value": "nrel00000962"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001099",
+ "@id": "urn:nrel_example/nrel00000198",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -22386,33 +21888,33 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001099"
+ "@value": "nrel00000198"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001163",
+ "@id": "urn:nrel_example/nrel00000225",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001163"
+ "@value": "nrel00000225"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000876",
+ "@id": "urn:nrel_example/nrel00000098",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -22423,14 +21925,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000876"
+ "@value": "nrel00000098"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001203",
+ "@id": "urn:nrel_example/nrel00000541",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -22439,512 +21941,490 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001203"
+ "@value": "nrel00000541"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000578",
+ "@id": "urn:nrel_example/nrel00000119",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000578"
+ "@value": "nrel00000119"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000880",
+ "@id": "urn:nrel_example/nrel00000500",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001125"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000216"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001168"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000880"
+ "@value": "nrel00000500"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001045",
+ "@id": "urn:nrel_example/nrel00001273",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001045"
+ "@value": "nrel00001273"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001229",
+ "@id": "urn:nrel_example/nrel00001196",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001229"
+ "@value": "nrel00001196"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000214",
+ "@id": "urn:nrel_example/nrel00000435",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#TerminalUnit"
+ ],
+ "http://data.ashrae.org/standard223#contains": [
+ {
+ "@id": "urn:nrel_example/nrel00000110"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000142"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000460"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000849"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000917"
+ }
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000408"
+ "@id": "urn:nrel_example/nrel00000462"
},
{
- "@id": "urn:nrel_example/nrel00000526"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000395"
+ "@id": "urn:nrel_example/nrel00000048"
},
{
- "@id": "urn:nrel_example/nrel00001170"
+ "@id": "urn:nrel_example/nrel00000124"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000641"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000214"
+ "@value": "nrel00000435"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000614",
+ "@id": "urn:nrel_example/nrel00000688",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000614"
+ "@value": "nrel00000688"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000137",
+ "@id": "urn:nrel_example/nrel00000752",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000810"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000623"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000137"
+ "@value": "nrel00000752"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000819",
+ "@id": "urn:nrel_example/nrel00000004",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000819"
+ "@value": "nrel00000004"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001273",
+ "@id": "urn:nrel_example/nrel00001245",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001273"
+ "@value": "nrel00001245"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001003",
+ "@id": "urn:nrel_example/nrel00000652",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000050"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000853"
+ "@id": "urn:nrel_example/nrel00001197"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00001003"
+ "@id": "urn:nrel_example/nrel00001121"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000244",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "urn:nrel_example/nrel00000499"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000244"
+ "@value": "nrel00000652"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000847",
+ "@id": "urn:nrel_example/nrel00000118",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000847"
+ "@value": "nrel00000118"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000836",
+ "@id": "urn:nrel_example/nrel00001161",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000836"
+ "@value": "nrel00001161"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001292",
+ "@id": "urn:nrel_example/nrel00000790",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001300"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000147"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001292"
+ "@value": "nrel00000790"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000307",
+ "@id": "urn:nrel_example/nrel00000370",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000517"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000307"
+ "@value": "nrel00000370"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001019",
+ "@id": "urn:nrel_example/nrel00000063",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001019"
+ "@value": "nrel00000063"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000209",
+ "@id": "urn:nrel_example/nrel00000854",
"@type": [
- "http://data.ashrae.org/standard223#FanCoilUnit"
- ],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000099"
- },
- {
- "@id": "urn:nrel_example/nrel00000135"
- },
- {
- "@id": "urn:nrel_example/nrel00000904"
- }
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000131"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000355"
+ "@id": "urn:nrel_example/nrel00000781"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000392"
- },
- {
- "@id": "urn:nrel_example/nrel00000752"
- },
- {
- "@id": "urn:nrel_example/nrel00000805"
- },
- {
- "@id": "urn:nrel_example/nrel00001160"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00001233"
+ "@id": "urn:nrel_example/nrel00001027"
}
],
- "http://data.ashrae.org/standard223#hasRole": [
- {
- "@id": "http://data.ashrae.org/standard223#Role-Cooling"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Role-Heating"
+ "@id": "urn:nrel_example/nrel00000537"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000209"
+ "@value": "nrel00000854"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000101",
+ "@id": "urn:nrel_example/nrel00001148",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000736"
- }
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000969"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001014"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000101"
+ "@value": "nrel00001148"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000973",
+ "@id": "urn:nrel_example/nrel00000332",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000973"
+ "@value": "nrel00000332"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000079",
+ "@id": "urn:nrel_example/nrel00000293",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001069"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000419"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000079"
+ "@value": "nrel00000293"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000422",
+ "@id": "urn:nrel_example/nrel00000685",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000422"
+ "@value": "nrel00000685"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000031",
+ "@id": "urn:nrel_example/nrel00000123",
"@type": [
"http://data.ashrae.org/standard223#Valve"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000840"
+ "@id": "urn:nrel_example/nrel00000290"
},
{
- "@id": "urn:nrel_example/nrel00000858"
+ "@id": "urn:nrel_example/nrel00001091"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000268"
+ "@id": "urn:nrel_example/nrel00000440"
},
{
- "@id": "urn:nrel_example/nrel00000598"
+ "@id": "urn:nrel_example/nrel00000689"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000031"
+ "@value": "nrel00000123"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000806",
+ "@id": "urn:nrel_example/nrel00000850",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000806"
+ "@value": "nrel00000850"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000320",
+ "@id": "urn:nrel_example/nrel00000644",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000320"
+ "@value": "nrel00000644"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001220",
+ "@id": "urn:nrel_example/nrel00000325",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -22960,56 +22440,51 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001220"
+ "@value": "nrel00000325"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001206",
+ "@id": "urn:nrel_example/nrel00000066",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001206"
+ "@value": "nrel00000066"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000049",
+ "@id": "urn:nrel_example/nrel00000749",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000165"
+ "@id": "urn:nrel_example/nrel00000715"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000175"
+ "@id": "urn:nrel_example/nrel00000946"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000049"
+ "@value": "nrel00000749"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001290",
+ "@id": "urn:nrel_example/nrel00000753",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
@@ -23018,161 +22493,204 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001290"
+ "@value": "nrel00000753"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000617",
+ "@id": "urn:nrel_example/nrel00000879",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@value": "nrel00000879"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000951",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000617"
+ "@value": "nrel00000951"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000731",
+ "@id": "urn:nrel_example/nrel00000067",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000640"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001270"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000731"
+ "@value": "nrel00000067"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000939",
+ "@id": "urn:nrel_example/nrel00000259",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000281"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000474"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000308"
- },
+ "@value": "nrel00000259"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000676",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001090"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000939"
+ "@value": "nrel00000676"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000121",
+ "@id": "urn:nrel_example/nrel00000770",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000941"
+ "@id": "urn:nrel_example/nrel00000882"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001192"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000071"
+ "@id": "urn:nrel_example/nrel00000143"
},
{
- "@id": "urn:nrel_example/nrel00000576"
+ "@id": "urn:nrel_example/nrel00000244"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000276"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000311"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000624"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000753"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000943"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001035"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001055"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001309"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001322"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000121"
+ "@value": "nrel00000770"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000851",
+ "@id": "urn:nrel_example/nrel00001053",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000851"
+ "@value": "nrel00001053"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000270",
+ "@id": "urn:nrel_example/nrel00000402",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000270"
+ "@value": "nrel00000402"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000036",
+ "@id": "urn:nrel_example/nrel00000288",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
@@ -23182,494 +22700,1179 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000036"
+ "@value": "nrel00000288"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000224",
+ "@id": "urn:nrel_example/nrel00001283",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000224"
+ "@value": "nrel00001283"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000271",
+ "@id": "urn:nrel_example/nrel00000948",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000271"
+ "@value": "nrel00000948"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000825",
+ "@id": "urn:nrel_example/nrel00000474",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@value": "nrel00000474"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000057",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000825"
+ "@value": "nrel00000057"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000626",
+ "@id": "urn:nrel_example/nrel00000807",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000004"
+ "@id": "urn:nrel_example/nrel00000045"
},
{
- "@id": "urn:nrel_example/nrel00000955"
+ "@id": "urn:nrel_example/nrel00001157"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00001030"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001218"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000626"
+ "@value": "nrel00000807"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000670",
+ "@id": "urn:nrel_example/nrel00000148",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00001046"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00001067"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000670"
+ "@value": "nrel00000148"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000996",
+ "@id": "urn:nrel_example/nrel00000983",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000996"
+ "@value": "nrel00000983"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001067",
+ "@id": "urn:nrel_example/nrel00001132",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001067"
+ "@value": "nrel00001132"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000936",
+ "@id": "urn:nrel_example/nrel00000701",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00001025"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001203"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000936"
+ "@value": "nrel00000701"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001171",
+ "@id": "urn:nrel_example/nrel00001123",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001171"
+ "@value": "nrel00001123"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000411",
+ "@id": "urn:nrel_example/nrel00000376",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000411"
+ "@value": "nrel00000376"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000526",
+ "@id": "urn:nrel_example/nrel00000464",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "urn:nrel_example/nrel00000862"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000825"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000956"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000526"
+ "@value": "nrel00000464"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000330",
+ "@id": "urn:nrel_example/nrel00000543",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000330"
+ "@value": "nrel00000543"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000774",
+ "@id": "urn:nrel_example/nrel00001004",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000221"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000336"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000680"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000774"
+ "@value": "nrel00001004"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000572",
+ "@id": "urn:nrel_example/nrel00000075",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000572"
+ "@value": "nrel00000075"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001066",
+ "@id": "urn:nrel_example/nrel00000748",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001066"
+ "@value": "nrel00000748"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000134",
+ "@id": "urn:nrel_example/nrel00001097",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000134"
+ "@value": "nrel00001097"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000628",
+ "@id": "urn:nrel_example/nrel00000890",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000677"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001262"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000632"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000716"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000628"
+ "@value": "nrel00000890"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000830",
+ "@id": "urn:nrel_example/nrel00000414",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000252"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001159"
+ "@id": "urn:nrel_example/nrel00000207"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000238"
- },
- {
- "@id": "urn:nrel_example/nrel00000359"
- },
- {
- "@id": "urn:nrel_example/nrel00000427"
- },
- {
- "@id": "urn:nrel_example/nrel00000645"
- },
- {
- "@id": "urn:nrel_example/nrel00000791"
- },
- {
- "@id": "urn:nrel_example/nrel00000861"
- },
- {
- "@id": "urn:nrel_example/nrel00000880"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000977"
- },
+ "@id": "urn:nrel_example/nrel00001163"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00001019"
- },
+ "@value": "nrel00000414"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000166",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001048"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001217"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000830"
+ "@value": "nrel00000166"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000099",
+ "@id": "http://data.ashrae.org/standard223#HeatRecoveryCoil",
+ "http://www.w3.org/2000/01/rdf-schema#subClassOf": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Coil"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000179",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#Pump"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000297"
+ "@id": "urn:nrel_example/nrel00000178"
},
{
- "@id": "urn:nrel_example/nrel00000541"
+ "@id": "urn:nrel_example/nrel00000264"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000036"
- },
- {
- "@id": "urn:nrel_example/nrel00000181"
+ "@id": "urn:nrel_example/nrel00000041"
},
{
- "@id": "urn:nrel_example/nrel00000210"
+ "@id": "urn:nrel_example/nrel00000097"
},
{
- "@id": "urn:nrel_example/nrel00000259"
+ "@id": "urn:nrel_example/nrel00000445"
},
{
- "@id": "urn:nrel_example/nrel00000304"
+ "@id": "urn:nrel_example/nrel00000646"
},
{
- "@id": "urn:nrel_example/nrel00000375"
+ "@id": "urn:nrel_example/nrel00000696"
},
{
- "@id": "urn:nrel_example/nrel00000609"
+ "@id": "urn:nrel_example/nrel00000860"
},
{
- "@id": "urn:nrel_example/nrel00000690"
+ "@id": "urn:nrel_example/nrel00000990"
},
{
- "@id": "urn:nrel_example/nrel00000744"
+ "@id": "urn:nrel_example/nrel00001031"
},
{
- "@id": "urn:nrel_example/nrel00000954"
+ "@id": "urn:nrel_example/nrel00001191"
},
{
- "@id": "urn:nrel_example/nrel00001147"
+ "@id": "urn:nrel_example/nrel00001230"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000099"
+ "@value": "nrel00000179"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001198",
+ "@id": "urn:nrel_example/nrel00001073",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000461"
- },
- {
- "@id": "urn:nrel_example/nrel00001166"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001198"
+ "@value": "nrel00001073"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000950",
+ "@id": "urn:nrel_example/nrel00001320",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000792"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@value": "nrel00000950"
+ "@id": "urn:nrel_example/nrel00000464"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000825"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001320"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000008",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000008"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000570",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000570"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001180",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000172"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000885"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001179"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001180"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000546",
+ "@type": [
+ "http://data.ashrae.org/standard223#Equipment"
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000546"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000182",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000182"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000006",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000006"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000497",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00001265"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000726"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000497"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000655",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000688"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000655"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000774",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000774"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000415",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000415"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000183",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000183"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001309",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001309"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000398",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000398"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000661",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000661"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001135",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001135"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000304",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000304"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000689",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000689"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000933",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000933"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000892",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000077"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000892"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000718",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000718"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000256",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000256"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000551",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000551"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000287",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000287"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000357",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000357"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000333",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000333"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001087",
+ "@type": [
+ "http://data.ashrae.org/standard223#Filter"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000107"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000908"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00001213"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001087"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000232",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000232"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000815",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00001033"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001229"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000762"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001041"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000815"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001146",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001146"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001023",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001023"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001227",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001227"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001318",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000122"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00001027"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000335"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001318"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000781",
+ "@id": "urn:nrel_example/nrel00001295",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001295"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000657",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000779"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000912"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000767"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001133"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000657"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000640",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -23680,44 +23883,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000781"
+ "@value": "nrel00000640"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000639",
+ "@id": "urn:nrel_example/nrel00000125",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000639"
+ "@value": "nrel00000125"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000762",
+ "@id": "urn:nrel_example/nrel00000466",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000762"
+ "@value": "nrel00000466"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000407",
+ "@id": "urn:nrel_example/nrel00000912",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -23728,126 +23936,214 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000407"
+ "@value": "nrel00000912"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001119",
+ "@id": "urn:nrel_example/nrel00001066",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000703"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001078"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000406"
- },
+ "@value": "nrel00001066"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000127",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001077"
+ "@id": "urn:nrel_example/nrel00000631"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000072"
- },
+ "@id": "urn:nrel_example/nrel00000241"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000116"
- },
+ "@id": "urn:nrel_example/nrel00001085"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000126"
- },
+ "@value": "nrel00000127"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001257",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000164"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000272"
- },
+ "@id": "http://qudt.org/vocab/unit/A"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000401"
- },
+ "@value": "nrel00001257"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000030",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000558"
- },
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000616"
- },
+ "@value": "nrel00000030"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001312",
+ "@type": [
+ "http://data.ashrae.org/standard223#Sensor"
+ ],
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000670"
+ "@id": "urn:nrel_example/nrel00000818"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000336"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001130"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001312"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000941",
+ "@type": [
+ "http://data.ashrae.org/standard223#DomainSpace"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000251"
},
{
- "@id": "urn:nrel_example/nrel00000935"
+ "@id": "urn:nrel_example/nrel00000846"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000404"
},
{
- "@id": "urn:nrel_example/nrel00001127"
+ "@id": "urn:nrel_example/nrel00000681"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001119"
+ "@value": "nrel00000941"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000260",
+ "@id": "urn:nrel_example/nrel00000720",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
+ ],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000441"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000720"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000671",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000260"
+ "@value": "nrel00000671"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000404",
+ "@id": "urn:nrel_example/nrel00000849",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000948"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000048"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000404"
+ "@value": "nrel00000849"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001325",
+ "@id": "urn:nrel_example/nrel00000278",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000724"
- },
- {
- "@id": "urn:nrel_example/nrel00000802"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -23856,80 +24152,78 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001325"
+ "@value": "nrel00000278"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000359",
+ "@id": "urn:nrel_example/nrel00000106",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000359"
+ "@value": "nrel00000106"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000574",
+ "@id": "urn:nrel_example/nrel00001057",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00001211"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000574"
+ "@value": "nrel00001057"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000429",
+ "@id": "urn:nrel_example/nrel00000631",
"@type": [
- "http://data.ashrae.org/standard223#Filter"
+ "http://data.ashrae.org/standard223#DomainSpace"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000158"
+ "@id": "urn:nrel_example/nrel00000138"
},
{
- "@id": "urn:nrel_example/nrel00000940"
+ "@id": "urn:nrel_example/nrel00001200"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasDomain": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000250"
+ "@id": "urn:nrel_example/nrel00000665"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001085"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000429"
+ "@value": "nrel00000631"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000296",
+ "@id": "urn:nrel_example/nrel00001234",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -23938,12 +24232,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000296"
+ "@value": "nrel00001234"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000319",
+ "@id": "urn:nrel_example/nrel00000993",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -23959,99 +24253,76 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000319"
+ "@value": "nrel00000993"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000410",
+ "@id": "urn:nrel_example/nrel00000379",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000410"
+ "@value": "nrel00000379"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000567",
+ "@id": "urn:nrel_example/nrel00001165",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@value": "nrel00000567"
+ "@id": "urn:nrel_example/nrel00001267"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001315",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000441"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
+ "@id": "urn:nrel_example/nrel00000567"
+ },
{
- "@id": "urn:nrel_example/nrel00000132"
+ "@id": "urn:nrel_example/nrel00000637"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001315"
+ "@value": "nrel00001165"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000132",
+ "@id": "urn:nrel_example/nrel00001317",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000132"
+ "@value": "nrel00001317"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000699",
+ "@id": "urn:nrel_example/nrel00000525",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000535"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
@@ -24059,220 +24330,243 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000699"
+ "@value": "nrel00000525"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000412",
+ "@id": "urn:nrel_example/nrel00000460",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000300"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000817"
+ },
{
- "@value": "nrel00000412"
+ "@id": "urn:nrel_example/nrel00001162"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000553",
- "@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000649"
+ "@id": "urn:nrel_example/nrel00000065"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001050"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001072"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001107"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000555"
+ "@id": "urn:nrel_example/nrel00000518"
},
{
- "@id": "urn:nrel_example/nrel00000930"
+ "@id": "urn:nrel_example/nrel00000684"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000553"
+ "@value": "nrel00000460"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001155",
+ "@id": "urn:nrel_example/nrel00000953",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000354"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000985"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001155"
+ "@value": "nrel00000953"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000376",
+ "@id": "urn:nrel_example/nrel00000590",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000376"
+ "@value": "nrel00000590"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000989",
+ "@id": "urn:nrel_example/nrel00001261",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000649"
- },
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000818"
- },
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000939"
- },
+ "@value": "nrel00001261"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000377",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000941"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000989"
+ "@value": "nrel00000377"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000815",
+ "@id": "urn:nrel_example/nrel00000038",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00001033"
+ "@id": "urn:nrel_example/nrel00000495"
},
{
- "@id": "urn:nrel_example/nrel00001229"
+ "@id": "urn:nrel_example/nrel00000780"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001187"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000762"
+ "@id": "urn:nrel_example/nrel00000420"
},
{
- "@id": "urn:nrel_example/nrel00001041"
+ "@id": "urn:nrel_example/nrel00001270"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@value": "nrel00000815"
+ "@id": "urn:nrel_example/nrel00000173"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000212"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000228"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000329"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000884"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000981",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000981"
+ "@value": "nrel00000038"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000168",
+ "@id": "urn:nrel_example/nrel00001281",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001265"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000042"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000168"
+ "@value": "nrel00001281"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001013",
+ "@id": "urn:nrel_example/nrel00000298",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001013"
+ "@value": "nrel00000298"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000089",
+ "@id": "urn:nrel_example/nrel00000716",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000089"
+ "@value": "nrel00000716"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000530",
+ "@id": "urn:nrel_example/nrel00000975",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -24283,49 +24577,49 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000530"
+ "@value": "nrel00000975"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000387",
+ "@id": "urn:nrel_example/nrel00000639",
"@type": [
"http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000387"
+ "@value": "nrel00000639"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000206",
+ "@id": "urn:nrel_example/nrel00000831",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000206"
+ "@value": "nrel00000831"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001107",
+ "@id": "urn:nrel_example/nrel00000229",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -24336,226 +24630,172 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001107"
+ "@value": "nrel00000229"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000472",
+ "@id": "urn:nrel_example/nrel00000769",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001241"
+ "@id": "urn:nrel_example/nrel00000162"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ {
+ "@id": "urn:nrel_example/nrel00000969"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000256"
+ "@id": "urn:nrel_example/nrel00000054"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000472"
+ "@value": "nrel00000769"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000540",
+ "@id": "urn:nrel_example/nrel00000544",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000540"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000607",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000607"
+ "@value": "nrel00000544"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000739",
+ "@id": "urn:nrel_example/nrel00001233",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000739"
+ "@value": "nrel00001233"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000706",
+ "@id": "urn:nrel_example/nrel00000823",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000706"
+ "@value": "nrel00000823"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000519",
+ "@id": "urn:nrel_example/nrel00000238",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000519"
+ "@value": "nrel00000238"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000754",
+ "@id": "urn:nrel_example/nrel00000786",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000376"
- },
- {
- "@id": "urn:nrel_example/nrel00000712"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000044"
- },
- {
- "@id": "urn:nrel_example/nrel00000180"
- },
- {
- "@id": "urn:nrel_example/nrel00000310"
- },
- {
- "@id": "urn:nrel_example/nrel00000370"
- },
- {
- "@id": "urn:nrel_example/nrel00000377"
- },
- {
- "@id": "urn:nrel_example/nrel00000639"
- },
- {
- "@id": "urn:nrel_example/nrel00000868"
- },
- {
- "@id": "urn:nrel_example/nrel00000997"
- },
- {
- "@id": "urn:nrel_example/nrel00001010"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001257"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000754"
+ "@value": "nrel00000786"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000560",
+ "@id": "urn:nrel_example/nrel00000654",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000560"
+ "@value": "nrel00000654"
}
]
},
- {
- "@id": "urn:nrel_example/nrel00000678",
- "@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000931"
- },
- {
- "@id": "urn:nrel_example/nrel00001256"
- }
+ {
+ "@id": "urn:nrel_example/nrel00000409",
+ "@type": [
+ "http://data.ashrae.org/standard223#Zone"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasDomainSpace": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000966"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000678"
+ "@value": "nrel00000409"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000220",
+ "@id": "urn:nrel_example/nrel00000802",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -24564,211 +24804,191 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000220"
+ "@value": "nrel00000802"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000555",
+ "@id": "urn:nrel_example/nrel00000234",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000555"
+ "@value": "nrel00000234"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000489",
+ "@id": "urn:nrel_example/nrel00001157",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000489"
+ "@value": "nrel00001157"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000449",
+ "@id": "urn:nrel_example/nrel00000280",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000784"
+ "@id": "urn:nrel_example/nrel00000003"
},
{
- "@id": "urn:nrel_example/nrel00001129"
+ "@id": "urn:nrel_example/nrel00000055"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000848"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000224"
- },
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000387"
+ "@id": "urn:nrel_example/nrel00000278"
},
{
- "@id": "urn:nrel_example/nrel00000458"
- },
+ "@id": "urn:nrel_example/nrel00001157"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000664"
+ "@id": "urn:nrel_example/nrel00000988"
},
{
- "@id": "urn:nrel_example/nrel00000692"
+ "@id": "urn:nrel_example/nrel00001152"
},
{
- "@id": "urn:nrel_example/nrel00000750"
+ "@id": "urn:nrel_example/nrel00001204"
},
{
- "@id": "urn:nrel_example/nrel00000871"
+ "@id": "urn:nrel_example/nrel00001244"
},
{
- "@id": "urn:nrel_example/nrel00001222"
- },
+ "@id": "urn:nrel_example/nrel00001282"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00001289"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
},
{
- "@id": "urn:nrel_example/nrel00001326"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000449"
+ "@value": "nrel00000280"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000311",
+ "@id": "urn:nrel_example/nrel00001278",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "urn:nrel_example/nrel00001260"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001311"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000311"
+ "@value": "nrel00001278"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000119",
+ "@id": "urn:nrel_example/nrel00000963",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000119"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001233",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001233"
+ "@value": "nrel00000963"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000914",
+ "@id": "urn:nrel_example/nrel00001120",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000914"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000953",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000953"
+ "@value": "nrel00001120"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000470",
+ "@id": "urn:nrel_example/nrel00001052",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00001267"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001165"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:nrel_example/nrel00000743"
+ "@id": "urn:nrel_example/nrel00000967"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000470"
+ "@value": "nrel00001052"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001288",
+ "@id": "urn:nrel_example/nrel00001126",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -24784,133 +25004,126 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001288"
+ "@value": "nrel00001126"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000301",
+ "@id": "urn:nrel_example/nrel00001211",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00000406"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000574"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000301"
+ "@value": "nrel00001211"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001038",
+ "@id": "urn:nrel_example/nrel00000801",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000676"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000203"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001038"
+ "@value": "nrel00000801"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001002",
+ "@id": "urn:nrel_example/nrel00000873",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001002"
+ "@value": "nrel00000873"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000103",
+ "@id": "urn:nrel_example/nrel00000776",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000103"
+ "@value": "nrel00000776"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000309",
+ "@id": "urn:nrel_example/nrel00000270",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000000"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001220"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000309"
+ "@value": "nrel00000270"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000845",
+ "@id": "urn:nrel_example/nrel00000935",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000845"
+ "@value": "nrel00000935"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000705",
+ "@id": "urn:nrel_example/nrel00001207",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -24921,21 +25134,21 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000705"
+ "@value": "nrel00001207"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000589",
+ "@id": "urn:nrel_example/nrel00000285",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000240"
+ "@id": "urn:nrel_example/nrel00000059"
},
{
- "@id": "urn:nrel_example/nrel00000903"
+ "@id": "urn:nrel_example/nrel00001161"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -24945,354 +25158,236 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000589"
+ "@value": "nrel00000285"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001154",
+ "@id": "urn:nrel_example/nrel00001224",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
"http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-FlowStatus"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001154"
+ "@value": "nrel00001224"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000154",
+ "@id": "urn:nrel_example/nrel00000529",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000154"
+ "@value": "nrel00000529"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000070",
+ "@id": "urn:nrel_example/nrel00000457",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000070"
+ "@value": "nrel00000457"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001303",
+ "@id": "urn:nrel_example/nrel00000161",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000622"
- },
- {
- "@id": "urn:nrel_example/nrel00000682"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000286"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000679"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001303"
+ "@value": "nrel00000161"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000832",
+ "@id": "urn:nrel_example/nrel00001145",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000832"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000251",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000251"
+ "@value": "nrel00001145"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000867",
+ "@id": "urn:nrel_example/nrel00000838",
"@type": [
- "http://data.ashrae.org/standard223#Zone"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasDomainSpace": [
- {
- "@id": "urn:nrel_example/nrel00000080"
- },
- {
- "@id": "urn:nrel_example/nrel00000122"
- },
- {
- "@id": "urn:nrel_example/nrel00000587"
- },
- {
- "@id": "urn:nrel_example/nrel00000600"
- },
- {
- "@id": "urn:nrel_example/nrel00000631"
- },
- {
- "@id": "urn:nrel_example/nrel00000736"
- },
- {
- "@id": "urn:nrel_example/nrel00000862"
- },
- {
- "@id": "urn:nrel_example/nrel00001125"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001197"
+ "@id": "urn:nrel_example/nrel00000399"
},
{
- "@id": "urn:nrel_example/nrel00001267"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000867"
+ "@id": "urn:nrel_example/nrel00000714"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000423",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000423"
+ "@value": "nrel00000838"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000531",
+ "@id": "urn:nrel_example/nrel00001266",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@id": "urn:nrel_example/nrel00000321"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001138"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000531"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000588",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000936"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000588"
+ "@value": "nrel00001266"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000068",
+ "@id": "urn:nrel_example/nrel00000582",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00001040"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00000571"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000068"
+ "@value": "nrel00000582"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000593",
+ "@id": "urn:nrel_example/nrel00000980",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000087"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000434"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000301"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001215"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000593"
+ "@value": "nrel00000980"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000053",
+ "@id": "urn:nrel_example/nrel00000041",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000461"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000931"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000012"
- },
- {
- "@id": "urn:nrel_example/nrel00000492"
- },
- {
- "@id": "urn:nrel_example/nrel00000550"
- },
- {
- "@id": "urn:nrel_example/nrel00000562"
- },
- {
- "@id": "urn:nrel_example/nrel00000566"
- },
- {
- "@id": "urn:nrel_example/nrel00000572"
- },
- {
- "@id": "urn:nrel_example/nrel00000607"
- },
- {
- "@id": "urn:nrel_example/nrel00000648"
- },
- {
- "@id": "urn:nrel_example/nrel00000877"
- },
- {
- "@id": "urn:nrel_example/nrel00001075"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001093"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000053"
+ "@value": "nrel00000041"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000824",
+ "@id": "urn:nrel_example/nrel00000295",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000386"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000532"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000410"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001248"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000824"
+ "@value": "nrel00000295"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000915",
+ "@id": "urn:nrel_example/nrel00000203",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -25308,12 +25403,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000915"
+ "@value": "nrel00000203"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000290",
+ "@id": "urn:nrel_example/nrel00000302",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -25324,51 +25419,72 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000290"
+ "@value": "nrel00000302"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000715",
+ "@id": "urn:nrel_example/nrel00000592",
+ "@type": [
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ ],
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
+ {
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000592"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001074",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000715"
+ "@value": "nrel00001074"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000664",
+ "@id": "urn:nrel_example/nrel00000550",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000664"
+ "@value": "nrel00000550"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000161",
+ "@id": "urn:nrel_example/nrel00000290",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -25377,86 +25493,105 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000161"
+ "@value": "nrel00000290"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000942",
+ "@id": "urn:nrel_example/nrel00000729",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000018"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000619"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000023"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000060"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000201"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000232"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000614"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000843"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000878"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000886"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000926"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001083"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001146"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000942"
+ "@value": "nrel00000729"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001021",
+ "@id": "urn:nrel_example/nrel00001282",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000186"
- },
- {
- "@id": "urn:nrel_example/nrel00001301"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001021"
+ "@value": "nrel00001282"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000336",
+ "@id": "urn:nrel_example/nrel00001138",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000818"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000471"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000680"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000336"
+ "@value": "nrel00001138"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000374",
+ "@id": "urn:nrel_example/nrel00000236",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000001"
- },
- {
- "@id": "urn:nrel_example/nrel00000219"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -25465,187 +25600,189 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000374"
+ "@value": "nrel00000236"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000127",
+ "@id": "urn:nrel_example/nrel00000077",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000631"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
+ "@id": "urn:nrel_example/nrel00000424"
+ },
{
- "@id": "urn:nrel_example/nrel00000241"
+ "@id": "urn:nrel_example/nrel00000892"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001085"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000127"
+ "@value": "nrel00000077"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000854",
+ "@id": "urn:nrel_example/nrel00001265",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000781"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001027"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000537"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000854"
+ "@value": "nrel00001265"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001243",
+ "@id": "urn:nrel_example/nrel00000521",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000281"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000708"
+ "@id": "urn:nrel_example/nrel00000354"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000866"
+ "@id": "urn:nrel_example/nrel00000139"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001243"
+ "@value": "nrel00000521"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000980",
+ "@id": "urn:nrel_example/nrel00000906",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000827"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000852"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000422"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000855"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000980"
+ "@value": "nrel00000906"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000808",
+ "@id": "urn:nrel_example/nrel00000361",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#CoolingCoil"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000313"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000870"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000808"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000001",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "@id": "urn:nrel_example/nrel00000030"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000704"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001034"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001264"
+ }
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000325"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000599"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000719"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000773"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001313"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000001"
+ "@value": "nrel00000361"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000230",
+ "@id": "urn:nrel_example/nrel00000330",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001194"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001022"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000230"
+ "@value": "nrel00000330"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000648",
+ "@id": "urn:nrel_example/nrel00001251",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000648"
+ "@value": "nrel00001251"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000986",
+ "@id": "urn:nrel_example/nrel00000222",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -25654,136 +25791,150 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000986"
+ "@value": "nrel00000222"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000990",
+ "@id": "urn:nrel_example/nrel00000830",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "urn:nrel_example/nrel00000252"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001159"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "urn:nrel_example/nrel00000238"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000359"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000427"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000645"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000791"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000861"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000880"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000977"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001019"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001048"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001217"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000990"
+ "@value": "nrel00000830"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000398",
+ "@id": "urn:nrel_example/nrel00000170",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000398"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000834",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000834"
+ "@value": "nrel00000170"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000651",
+ "@id": "urn:nrel_example/nrel00000930",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000651"
+ "@value": "nrel00000930"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000930",
+ "@id": "urn:nrel_example/nrel00000275",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000930"
+ "@value": "nrel00000275"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000905",
+ "@id": "urn:nrel_example/nrel00001190",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000444"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000597"
+ "@id": "urn:nrel_example/nrel00000389"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000968"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000905"
+ "@value": "nrel00001190"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000509",
+ "@id": "urn:nrel_example/nrel00000735",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -25794,205 +25945,246 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000509"
+ "@value": "nrel00000735"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000442",
+ "@id": "urn:nrel_example/nrel00000580",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "urn:nrel_example/nrel00000337"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000741"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001190"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "urn:nrel_example/nrel00000229"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000389"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000463"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000756"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000968"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001307"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000442"
+ "@value": "nrel00000580"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000345",
+ "@id": "urn:nrel_example/nrel00001231",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "urn:nrel_example/nrel00000366"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000655"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "urn:nrel_example/nrel00000695"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001271"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000345"
+ "@value": "nrel00001231"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000171",
+ "@id": "urn:nrel_example/nrel00000003",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000098"
+ "@id": "urn:nrel_example/nrel00000804"
},
{
- "@id": "urn:nrel_example/nrel00001207"
+ "@id": "urn:nrel_example/nrel00001038"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001156"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000612"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000676"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000897"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000953"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000203"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000895"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000171"
+ "@value": "nrel00000003"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000638",
+ "@id": "urn:nrel_example/nrel00000813",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Duct"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00001107"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001302"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000638"
+ "@value": "nrel00000813"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000325",
+ "@id": "urn:nrel_example/nrel00001326",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000325"
+ "@value": "nrel00001326"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001121",
+ "@id": "urn:nrel_example/nrel00001205",
"@type": [
- "http://data.ashrae.org/standard223#PhysicalSpace"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#encloses": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001197"
+ "@id": "urn:nrel_example/nrel00000504"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000009"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000068"
+ "@id": "urn:nrel_example/nrel00000263"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001121"
+ "@value": "nrel00001205"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000035",
+ "@id": "urn:nrel_example/nrel00000329",
"@type": [
- "http://data.ashrae.org/standard223#CoolingCoil"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000522"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000824"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000317"
- },
- {
- "@id": "urn:nrel_example/nrel00000685"
- },
- {
- "@id": "urn:nrel_example/nrel00000808"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000976"
+ "@value": "nrel00000329"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000019",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000028"
- },
- {
- "@id": "urn:nrel_example/nrel00000085"
- },
- {
- "@id": "urn:nrel_example/nrel00000243"
- },
- {
- "@id": "urn:nrel_example/nrel00000253"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000994"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000035"
+ "@value": "nrel00000019"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001034",
+ "@id": "urn:nrel_example/nrel00000851",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001034"
+ "@value": "nrel00000851"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000844",
+ "@id": "urn:nrel_example/nrel00001238",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -26008,219 +26200,187 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000844"
+ "@value": "nrel00001238"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001240",
+ "@id": "urn:nrel_example/nrel00000498",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001240"
+ "@value": "nrel00000498"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000618",
+ "@id": "urn:nrel_example/nrel00000296",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000517"
- }
- ],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000618"
+ "@value": "nrel00000296"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001139",
+ "@id": "urn:nrel_example/nrel00000925",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000441"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000118"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001139"
+ "@value": "nrel00000925"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000445",
+ "@id": "urn:nrel_example/nrel00001289",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000445"
+ "@value": "nrel00001289"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000779",
+ "@id": "urn:nrel_example/nrel00000081",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000779"
+ "@value": "nrel00000081"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000636",
+ "@id": "urn:nrel_example/nrel00000693",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00001194"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000373"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000636"
+ "@value": "nrel00000693"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000777",
+ "@id": "urn:nrel_example/nrel00000055",
"@type": [
"http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000776"
+ "@id": "urn:nrel_example/nrel00000079"
},
{
- "@id": "urn:nrel_example/nrel00001164"
+ "@id": "urn:nrel_example/nrel00000222"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000159"
+ "@id": "urn:nrel_example/nrel00000016"
},
{
- "@id": "urn:nrel_example/nrel00000185"
+ "@id": "urn:nrel_example/nrel00000037"
},
{
- "@id": "urn:nrel_example/nrel00000379"
+ "@id": "urn:nrel_example/nrel00000156"
},
{
- "@id": "urn:nrel_example/nrel00000450"
+ "@id": "urn:nrel_example/nrel00000195"
},
{
- "@id": "urn:nrel_example/nrel00000563"
+ "@id": "urn:nrel_example/nrel00000234"
},
{
- "@id": "urn:nrel_example/nrel00000662"
+ "@id": "urn:nrel_example/nrel00000479"
},
{
- "@id": "urn:nrel_example/nrel00000761"
+ "@id": "urn:nrel_example/nrel00000922"
},
{
- "@id": "urn:nrel_example/nrel00000778"
+ "@id": "urn:nrel_example/nrel00001073"
},
{
- "@id": "urn:nrel_example/nrel00000889"
+ "@id": "urn:nrel_example/nrel00001128"
},
{
- "@id": "urn:nrel_example/nrel00000974"
+ "@id": "urn:nrel_example/nrel00001173"
},
{
- "@id": "urn:nrel_example/nrel00001290"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000777"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000066",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000066"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000828",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000251"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000121"
- }
- ],
- "http://data.ashrae.org/standard223#observes": [
- {
- "@id": "urn:nrel_example/nrel00000071"
+ "@id": "urn:nrel_example/nrel00001214"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000828"
+ "@value": "nrel00000055"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000140",
+ "@id": "urn:nrel_example/nrel00001287",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -26236,157 +26396,91 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000140"
+ "@value": "nrel00001287"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001214",
+ "@id": "urn:nrel_example/nrel00000517",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
- {
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "nrel00001214"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000343",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "urn:nrel_example/nrel00000307"
+ },
{
- "@id": "urn:nrel_example/nrel00000134"
+ "@id": "urn:nrel_example/nrel00000618"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000669"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000343"
+ "@value": "nrel00000517"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000829",
+ "@id": "urn:nrel_example/nrel00000100",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000600"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000114"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000847"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000829"
+ "@value": "nrel00000100"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001314",
+ "@id": "urn:nrel_example/nrel00000151",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001314"
+ "@value": "nrel00000151"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000522",
+ "@id": "urn:nrel_example/nrel00000599",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000801"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000957"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000057"
- },
- {
- "@id": "urn:nrel_example/nrel00000144"
- },
- {
- "@id": "urn:nrel_example/nrel00000267"
- },
- {
- "@id": "urn:nrel_example/nrel00000341"
- },
- {
- "@id": "urn:nrel_example/nrel00000352"
- },
- {
- "@id": "urn:nrel_example/nrel00000507"
- },
- {
- "@id": "urn:nrel_example/nrel00000520"
- },
- {
- "@id": "urn:nrel_example/nrel00000900"
- },
- {
- "@id": "urn:nrel_example/nrel00001005"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001245"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000522"
+ "@value": "nrel00000599"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000149",
+ "@id": "urn:nrel_example/nrel00000897",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000211"
- },
- {
- "@id": "urn:nrel_example/nrel00000942"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -26395,28 +26489,28 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000149"
+ "@value": "nrel00000897"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000855",
+ "@id": "urn:nrel_example/nrel00000973",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000855"
+ "@value": "nrel00000973"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000046",
+ "@id": "urn:nrel_example/nrel00001235",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -26432,265 +26526,260 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000046"
+ "@value": "nrel00001235"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000771",
+ "@id": "urn:nrel_example/nrel00001284",
"@type": [
- "http://data.ashrae.org/standard223#Filter"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000307"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000699"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "urn:nrel_example/nrel00000154"
+ "@id": "urn:nrel_example/nrel00000961"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000771"
+ "@value": "nrel00001284"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000938",
+ "@id": "urn:nrel_example/nrel00001296",
"@type": [
- "http://data.ashrae.org/standard223#TerminalUnit"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000073"
- },
- {
- "@id": "urn:nrel_example/nrel00000324"
- },
- {
- "@id": "urn:nrel_example/nrel00000510"
- },
- {
- "@id": "urn:nrel_example/nrel00001223"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00001232"
+ "@id": "urn:nrel_example/nrel00001200"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000742"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000961"
+ "@id": "urn:nrel_example/nrel00000241"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000064"
- },
- {
- "@id": "urn:nrel_example/nrel00000332"
- },
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000475"
+ "@id": "urn:nrel_example/nrel00000274"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000938"
+ "@value": "nrel00001296"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000566",
+ "@id": "urn:nrel_example/nrel00000994",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000566"
+ "@value": "nrel00000994"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000520",
+ "@id": "urn:nrel_example/nrel00000050",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000520"
+ "@value": "nrel00000050"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001177",
+ "@id": "urn:nrel_example/nrel00000918",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001177"
+ "@value": "nrel00000918"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000195",
+ "@id": "urn:nrel_example/nrel00000007",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#HeatingCoil"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000383"
+ },
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000749"
+ },
{
- "@value": "nrel00000195"
+ "@id": "urn:nrel_example/nrel00001042"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000494",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00001023"
+ "@id": "urn:nrel_example/nrel00000430"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000715"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000903"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001256"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000081"
+ "@id": "urn:nrel_example/nrel00000795"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000946"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000494"
+ "@value": "nrel00000007"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000873",
+ "@id": "urn:nrel_example/nrel00001308",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Fan"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "@id": "urn:nrel_example/nrel00000291"
+ },
{
- "@value": "nrel00000873"
+ "@id": "urn:nrel_example/nrel00000496"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000875",
- "@type": [
- "http://data.ashrae.org/standard223#Duct"
],
- "http://data.ashrae.org/standard223#cnx": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000107"
+ "@id": "urn:nrel_example/nrel00000970"
},
{
- "@id": "urn:nrel_example/nrel00000899"
+ "@id": "urn:nrel_example/nrel00001207"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000283"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000651"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000661"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000674"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000811"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000963"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001016"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001132"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001272"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001273"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001331"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000875"
+ "@value": "nrel00001308"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001289",
+ "@id": "urn:nrel_example/nrel00000829",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "urn:nrel_example/nrel00000600"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "urn:nrel_example/nrel00000114"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000847"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001289"
+ "@value": "nrel00000829"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001036",
+ "@id": "urn:nrel_example/nrel00000253",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000462"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001036"
+ "@value": "nrel00000253"
}
]
},
@@ -26711,225 +26800,192 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000200",
+ "@id": "urn:nrel_example/nrel00000044",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
- "http://data.ashrae.org/standard223#mapsTo": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000354"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000200"
+ "@value": "nrel00000044"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001191",
+ "@id": "urn:nrel_example/nrel00000391",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001191"
+ "@value": "nrel00000391"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000156",
+ "@id": "urn:nrel_example/nrel00000518",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000156"
+ "@value": "nrel00000518"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000676",
+ "@id": "urn:nrel_example/nrel00000557",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00000676"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000026",
- "@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000026"
+ "@value": "nrel00000557"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000291",
+ "@id": "urn:nrel_example/nrel00000868",
"@type": [
- "http://data.ashrae.org/standard223#Damper"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000169"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001009"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000027"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000837"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000291"
+ "@value": "nrel00000868"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001081",
+ "@id": "urn:nrel_example/nrel00000874",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001081"
+ "@value": "nrel00000874"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000700",
+ "@id": "urn:nrel_example/nrel00000914",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000700"
+ "@value": "nrel00000914"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000017",
+ "@id": "urn:nrel_example/nrel00001323",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000017"
+ "@value": "nrel00001323"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001096",
+ "@id": "urn:nrel_example/nrel00001268",
"@type": [
- "http://data.ashrae.org/standard223#Junction"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000265"
- },
- {
- "@id": "urn:nrel_example/nrel00000876"
- },
- {
- "@id": "urn:nrel_example/nrel00001135"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001096"
+ "@value": "nrel00001268"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000945",
+ "@id": "urn:nrel_example/nrel00000805",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000945"
+ "@value": "nrel00000805"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001011",
+ "@id": "urn:nrel_example/nrel00000758",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -26945,22 +27001,14 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001011"
+ "@value": "nrel00000758"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001024",
+ "@id": "urn:nrel_example/nrel00001200",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000208"
- },
- {
- "@id": "urn:nrel_example/nrel00000947"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -26969,190 +27017,209 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001024"
+ "@value": "nrel00001200"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000371",
+ "@id": "urn:nrel_example/nrel00000777",
"@type": [
- "http://data.ashrae.org/standard223#Pump"
+ "http://data.ashrae.org/standard223#Fan"
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000723"
+ "@id": "urn:nrel_example/nrel00000776"
},
{
- "@id": "urn:nrel_example/nrel00001275"
+ "@id": "urn:nrel_example/nrel00001164"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000033"
+ "@id": "urn:nrel_example/nrel00000159"
},
{
- "@id": "urn:nrel_example/nrel00000136"
+ "@id": "urn:nrel_example/nrel00000185"
},
{
- "@id": "urn:nrel_example/nrel00000239"
+ "@id": "urn:nrel_example/nrel00000379"
},
{
- "@id": "urn:nrel_example/nrel00000385"
+ "@id": "urn:nrel_example/nrel00000450"
},
{
- "@id": "urn:nrel_example/nrel00000560"
+ "@id": "urn:nrel_example/nrel00000563"
},
{
- "@id": "urn:nrel_example/nrel00000584"
+ "@id": "urn:nrel_example/nrel00000662"
},
{
- "@id": "urn:nrel_example/nrel00000928"
+ "@id": "urn:nrel_example/nrel00000761"
},
{
- "@id": "urn:nrel_example/nrel00001150"
+ "@id": "urn:nrel_example/nrel00000778"
},
{
- "@id": "urn:nrel_example/nrel00001151"
+ "@id": "urn:nrel_example/nrel00000889"
},
{
- "@id": "urn:nrel_example/nrel00001171"
+ "@id": "urn:nrel_example/nrel00000974"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001290"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000371"
+ "@value": "nrel00000777"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000098",
+ "@id": "urn:nrel_example/nrel00000773",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000098"
+ "@value": "nrel00000773"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001051",
+ "@id": "urn:nrel_example/nrel00000633",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001051"
+ "@value": "nrel00000633"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000865",
+ "@id": "urn:nrel_example/nrel00000636",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Pressure"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/IN_H2O"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000865"
+ "@value": "nrel00000636"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000860",
+ "@id": "urn:nrel_example/nrel00000078",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000860"
+ "@value": "nrel00000078"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000917",
+ "@id": "urn:nrel_example/nrel00000675",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000948"
+ "@id": "urn:nrel_example/nrel00000574"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000691"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000124"
+ "@id": "urn:nrel_example/nrel00000347"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001153"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000917"
+ "@value": "nrel00000675"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000971",
+ "@id": "urn:nrel_example/nrel00000341",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000971"
+ "@value": "nrel00000341"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000886",
+ "@id": "urn:nrel_example/nrel00000713",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/A"
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000886"
+ "@value": "nrel00000713"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000612",
+ "@id": "urn:nrel_example/nrel00000638",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -27163,229 +27230,213 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000612"
+ "@value": "nrel00000638"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001260",
+ "@id": "urn:nrel_example/nrel00000026",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001260"
+ "@value": "nrel00000026"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000375",
+ "@id": "urn:nrel_example/nrel00000343",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00000134"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000669"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000375"
+ "@value": "nrel00000343"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000180",
+ "@id": "urn:nrel_example/nrel00000458",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/PERCENT"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000180"
+ "@value": "nrel00000458"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001015",
+ "@id": "urn:nrel_example/nrel00001022",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000487"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001099"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000024"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000979"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001015"
+ "@value": "nrel00001022"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000659",
+ "@id": "urn:nrel_example/nrel00001069",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000659"
+ "@value": "nrel00001069"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001318",
+ "@id": "urn:nrel_example/nrel00000871",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000122"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00001027"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000335"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001318"
+ "@value": "nrel00000871"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001122",
+ "@id": "urn:nrel_example/nrel00001011",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001122"
+ "@value": "nrel00001011"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000259",
+ "@id": "urn:nrel_example/nrel00000358",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/HZ"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000259"
+ "@value": "nrel00000358"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001295",
+ "@id": "urn:nrel_example/nrel00000864",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
- }
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001295"
+ "@value": "nrel00000864"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000488",
+ "@id": "urn:nrel_example/nrel00000221",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000488"
+ "@value": "nrel00000221"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000363",
+ "@id": "urn:nrel_example/nrel00000947",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000363"
+ "@value": "nrel00000947"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000993",
+ "@id": "urn:nrel_example/nrel00000571",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -27401,14 +27452,25 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000993"
+ "@value": "nrel00000571"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000841",
+ "@id": "urn:nrel_example/nrel00000058",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Junction"
+ ],
+ "http://data.ashrae.org/standard223#cnx": [
+ {
+ "@id": "urn:nrel_example/nrel00000760"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000984"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001260"
+ }
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -27417,7 +27479,7 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000841"
+ "@value": "nrel00000058"
}
]
},
@@ -27438,93 +27500,63 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000011",
- "@type": [
- "http://www.w3.org/2002/07/owl#Ontology"
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000011"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000055",
+ "@id": "urn:nrel_example/nrel00000982",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000079"
- },
- {
- "@id": "urn:nrel_example/nrel00000222"
- }
+ "http://data.ashrae.org/standard223#AirHandlingUnit"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000016"
- },
- {
- "@id": "urn:nrel_example/nrel00000037"
- },
+ "http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000156"
+ "@id": "urn:nrel_example/nrel00000007"
},
{
- "@id": "urn:nrel_example/nrel00000195"
+ "@id": "urn:nrel_example/nrel00000053"
},
{
- "@id": "urn:nrel_example/nrel00000234"
+ "@id": "urn:nrel_example/nrel00000061"
},
{
- "@id": "urn:nrel_example/nrel00000479"
+ "@id": "urn:nrel_example/nrel00000254"
},
{
- "@id": "urn:nrel_example/nrel00000922"
+ "@id": "urn:nrel_example/nrel00000446"
},
{
- "@id": "urn:nrel_example/nrel00001073"
+ "@id": "urn:nrel_example/nrel00000447"
},
{
- "@id": "urn:nrel_example/nrel00001128"
+ "@id": "urn:nrel_example/nrel00000683"
},
{
- "@id": "urn:nrel_example/nrel00001173"
+ "@id": "urn:nrel_example/nrel00000992"
},
{
- "@id": "urn:nrel_example/nrel00001214"
+ "@id": "urn:nrel_example/nrel00001087"
}
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@value": "nrel00000055"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000300",
- "@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "@id": "urn:nrel_example/nrel00000078"
+ },
{
- "@id": "urn:nrel_example/nrel00001050"
+ "@id": "urn:nrel_example/nrel00000211"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "urn:nrel_example/nrel00000518"
+ "@id": "urn:nrel_example/nrel00000034"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001070"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000300"
+ "@value": "nrel00000982"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001178",
+ "@id": "urn:nrel_example/nrel00000348",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -27540,290 +27572,272 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001178"
+ "@value": "nrel00000348"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000879",
+ "@id": "urn:nrel_example/nrel00000087",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000879"
+ "@value": "nrel00000087"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000769",
+ "@id": "urn:nrel_example/nrel00000153",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
- ],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
- {
- "@id": "urn:nrel_example/nrel00000162"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000969"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000054"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000769"
+ "@value": "nrel00000153"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000755",
+ "@id": "urn:nrel_example/nrel00000532",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000380"
- },
- {
- "@id": "urn:nrel_example/nrel00000491"
- }
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000473"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000883"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000755"
+ "@value": "nrel00000532"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000891",
+ "@id": "urn:nrel_example/nrel00001033",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000158"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000577"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#mapsTo": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00001123"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000891"
+ "@value": "nrel00001033"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000584",
+ "@id": "urn:nrel_example/nrel00000136",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPower"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "http://qudt.org/vocab/unit/KiloW"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000584"
+ "@value": "nrel00000136"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000616",
+ "@id": "urn:nrel_example/nrel00001330",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000846"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000121"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000576"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000616"
+ "@value": "nrel00001330"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000546",
+ "@id": "urn:nrel_example/nrel00000248",
"@type": [
- "http://data.ashrae.org/standard223#Equipment"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
+ {
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ }
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000546"
+ "@value": "nrel00000248"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000039",
+ "@id": "urn:nrel_example/nrel00000520",
"@type": [
- "http://data.ashrae.org/standard223#Sensor"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasObservationLocation": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00001226"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#observes": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00000933"
+ "@id": "http://qudt.org/vocab/unit/A"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00000520"
}
+ ]
+ },
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Overridden",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus",
+ "http://data.ashrae.org/standard223#EnumerationKind-Override"
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000039"
+ "@language": "en",
+ "@value": "AlarmStatus-Ok"
+ },
+ {
+ "@language": "en",
+ "@value": "Override-Overridden"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000264",
+ "@id": "urn:nrel_example/nrel00000627",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000264"
+ "@value": "nrel00000627"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000116",
+ "@id": "urn:nrel_example/nrel00000451",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000116"
+ "@value": "nrel00000451"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000044",
+ "@id": "urn:nrel_example/nrel00000073",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ "@id": "urn:nrel_example/nrel00000961"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "http://qudt.org/vocab/unit/KiloW-HR"
+ "@id": "urn:nrel_example/nrel00000332"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000044"
+ "@value": "nrel00000073"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000331",
+ "@id": "urn:nrel_example/nrel00000578",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000331"
+ "@value": "nrel00000578"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000184",
+ "@id": "urn:nrel_example/nrel00000338",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
- }
- ],
- "http://www.w3.org/2000/01/rdf-schema#label": [
- {
- "@value": "nrel00000184"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000633",
- "@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000633"
+ "@value": "nrel00000338"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001194",
+ "@id": "urn:nrel_example/nrel00000018",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
@@ -27834,12 +27848,12 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001194"
+ "@value": "nrel00000018"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001173",
+ "@id": "urn:nrel_example/nrel00000744",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -27855,37 +27869,48 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001173"
+ "@value": "nrel00000744"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001157",
+ "@id": "urn:nrel_example/nrel00001015",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000487"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001099"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000024"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000979"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001157"
+ "@value": "nrel00001015"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000490",
+ "@id": "urn:nrel_example/nrel00000022",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00001020"
+ "@id": "urn:nrel_example/nrel00000190"
},
{
- "@id": "urn:nrel_example/nrel00001200"
+ "@id": "urn:nrel_example/nrel00000366"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -27895,145 +27920,131 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000490"
+ "@value": "nrel00000022"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000173",
+ "@id": "urn:nrel_example/nrel00001332",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000173"
+ "@value": "nrel00001332"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000084",
+ "@id": "urn:nrel_example/nrel00000883",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000133"
- },
- {
- "@id": "urn:nrel_example/nrel00000593"
- },
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "urn:nrel_example/nrel00000772"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000151"
- },
- {
- "@id": "urn:nrel_example/nrel00000167"
- },
- {
- "@id": "urn:nrel_example/nrel00000432"
- },
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000991"
+ "@value": "nrel00000883"
}
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001279",
+ "@type": [
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000978"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001235"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000084"
+ "@value": "nrel00001279"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000480",
+ "@id": "urn:nrel_example/nrel00000121",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000220"
- },
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@id": "urn:nrel_example/nrel00000420"
+ "@id": "urn:nrel_example/nrel00000941"
}
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000071"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000576"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000480"
+ "@value": "nrel00000121"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000273",
+ "@id": "urn:nrel_example/nrel00000372",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#contains": [
- {
- "@id": "urn:nrel_example/nrel00000214"
- },
- {
- "@id": "urn:nrel_example/nrel00000293"
- },
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000920"
+ "@id": "urn:nrel_example/nrel00000893"
}
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000040"
- },
- {
- "@id": "urn:nrel_example/nrel00000638"
- },
+ "http://data.ashrae.org/standard223#hasPhysicalLocation": [
{
- "@id": "urn:nrel_example/nrel00000720"
- },
+ "@id": "urn:nrel_example/nrel00000553"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00001069"
+ "@id": "urn:nrel_example/nrel00000930"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "urn:nrel_example/nrel00000412"
- },
+ "@value": "nrel00000372"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000924",
+ "@type": [
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ ],
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00000419"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000273"
+ "@value": "nrel00000924"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001247",
+ "@id": "urn:nrel_example/nrel00000915",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -28049,14 +28060,30 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001247"
+ "@value": "nrel00000915"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000901",
+ "@id": "urn:nrel_example/nrel00001290",
+ "@type": [
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ ],
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ {
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ }
+ ],
+ "http://www.w3.org/2000/01/rdf-schema#label": [
+ {
+ "@value": "nrel00001290"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000798",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28065,7 +28092,7 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000901"
+ "@value": "nrel00000798"
}
]
},
@@ -28091,151 +28118,119 @@
]
},
{
- "@id": "urn:nrel_example/nrel00000818",
+ "@id": "urn:nrel_example/nrel00000228",
"@type": [
- "http://data.ashrae.org/standard223#DomainSpace"
- ],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000221"
- },
- {
- "@id": "urn:nrel_example/nrel00001086"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasDomain": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Domain-HVAC"
+ "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000739"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001130"
+ "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000818"
+ "@value": "nrel00000228"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000285",
+ "@id": "urn:nrel_example/nrel00000481",
"@type": [
- "http://data.ashrae.org/standard223#Duct"
- ],
- "http://data.ashrae.org/standard223#cnx": [
- {
- "@id": "urn:nrel_example/nrel00000059"
- },
- {
- "@id": "urn:nrel_example/nrel00001161"
- }
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-Override"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000285"
+ "@value": "nrel00000481"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001138",
+ "@id": "urn:nrel_example/nrel00000042",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001138"
+ "@value": "nrel00000042"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000894",
+ "@id": "urn:nrel_example/nrel00000172",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
- }
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@value": "nrel00000894"
- }
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00000823",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "@id": "urn:nrel_example/nrel00000351"
+ },
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00001180"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000823"
+ "@value": "nrel00000172"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000718",
+ "@id": "urn:nrel_example/nrel00000575",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/Pressure"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/IN_H2O"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000718"
+ "@value": "nrel00000575"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000838",
+ "@id": "urn:nrel_example/nrel00000535",
"@type": [
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000399"
+ "@id": "urn:nrel_example/nrel00000691"
},
{
- "@id": "urn:nrel_example/nrel00000714"
+ "@id": "urn:nrel_example/nrel00000699"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
@@ -28245,44 +28240,54 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000838"
+ "@value": "nrel00000535"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000145",
+ "@id": "urn:nrel_example/nrel00000920",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "urn:nrel_example/nrel00000638"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00000412"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000145"
+ "@value": "nrel00000920"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000231",
+ "@id": "urn:nrel_example/nrel00000218",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
+ "@id": "http://qudt.org/vocab/quantitykind/Energy"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/KiloW-HR"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000231"
+ "@value": "nrel00000218"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000619",
+ "@id": "urn:nrel_example/nrel00001274",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -28291,53 +28296,58 @@
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
+ "http://data.ashrae.org/standard223#mapsTo": [
+ {
+ "@id": "urn:nrel_example/nrel00000078"
+ }
+ ],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000619"
+ "@value": "nrel00001274"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001271",
+ "@id": "urn:nrel_example/nrel00000093",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "http://data.ashrae.org/standard223#Medium-Water"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001271"
+ "@value": "nrel00000093"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000228",
+ "@id": "urn:nrel_example/nrel00000113",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/RelativeHumidity"
+ "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT_RH"
+ "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000228"
+ "@value": "nrel00000113"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000356",
+ "@id": "urn:nrel_example/nrel00000894",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
@@ -28346,33 +28356,36 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000356"
+ "@value": "nrel00000894"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000199",
+ "@id": "urn:nrel_example/nrel00000605",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Duct"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "urn:nrel_example/nrel00000151"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001229"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000199"
+ "@value": "nrel00000605"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001069",
+ "@id": "urn:nrel_example/nrel00000320",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
@@ -28383,182 +28396,208 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001069"
+ "@value": "nrel00000320"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000047",
+ "@id": "urn:nrel_example/nrel00000230",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
+ "http://data.ashrae.org/standard223#Sensor"
],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
+ "http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
+ "@id": "urn:nrel_example/nrel00001194"
+ }
+ ],
+ "http://data.ashrae.org/standard223#observes": [
+ {
+ "@id": "urn:nrel_example/nrel00001022"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000047"
+ "@value": "nrel00000230"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000283",
+ "@id": "urn:nrel_example/nrel00000876",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@value": "nrel00000876"
+ }
+ ]
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000313",
+ "@type": [
+ "http://data.ashrae.org/standard223#Valve"
+ ],
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
+ {
+ "@id": "urn:nrel_example/nrel00000296"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000428"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000066"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00001269"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000283"
+ "@value": "nrel00000313"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000627",
+ "@id": "urn:nrel_example/nrel00001303",
"@type": [
- "http://data.ashrae.org/standard223#InletConnectionPoint"
+ "http://data.ashrae.org/standard223#Valve"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "urn:nrel_example/nrel00000622"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000682"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000286"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000679"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000627"
+ "@value": "nrel00001303"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000927",
+ "@id": "urn:nrel_example/nrel00001127",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
+ "@id": "http://qudt.org/vocab/quantitykind/Frequency"
+ }
+ ],
+ "http://qudt.org/schema/qudt/hasUnit": [
+ {
+ "@id": "http://qudt.org/vocab/unit/HZ"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000927"
+ "@value": "nrel00001127"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001061",
+ "@id": "urn:nrel_example/nrel00000650",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001061"
+ "@value": "nrel00000650"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001301",
+ "@id": "urn:nrel_example/nrel00001110",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
- ],
- "http://data.ashrae.org/standard223#hasMedium": [
- {
- "@id": "http://data.ashrae.org/standard223#Medium-Air"
- }
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@value": "nrel00001301"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001264",
- "@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://qudt.org/vocab/unit/V"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001264"
+ "@value": "nrel00001110"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000657",
+ "@id": "urn:nrel_example/nrel00000240",
"@type": [
- "http://data.ashrae.org/standard223#Valve"
+ "http://data.ashrae.org/standard223#InletConnectionPoint"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000779"
- },
+ "http://data.ashrae.org/standard223#cnx": [
{
- "@id": "urn:nrel_example/nrel00000912"
+ "@id": "urn:nrel_example/nrel00000589"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000767"
- },
+ "http://data.ashrae.org/standard223#hasMedium": [
{
- "@id": "urn:nrel_example/nrel00001133"
+ "@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000657"
+ "@value": "nrel00000240"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001120",
+ "@id": "urn:nrel_example/nrel00000738",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "http://qudt.org/vocab/quantitykind/ElectricPotential"
+ "@id": "http://qudt.org/vocab/quantitykind/Temperature"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "http://qudt.org/vocab/unit/V"
+ "@id": "http://qudt.org/vocab/unit/DEG_C"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001120"
+ "@value": "nrel00000738"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000139",
+ "@id": "urn:nrel_example/nrel00000866",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
@@ -28574,226 +28613,187 @@
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000139"
+ "@value": "nrel00000866"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000729",
+ "@id": "urn:nrel_example/nrel00001075",
"@type": [
- "http://data.ashrae.org/standard223#Fan"
+ "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://data.ashrae.org/standard223#hasConnectionPoint": [
- {
- "@id": "urn:nrel_example/nrel00000018"
- },
+ "http://qudt.org/schema/qudt/hasQuantityKind": [
{
- "@id": "urn:nrel_example/nrel00000619"
+ "@id": "http://qudt.org/vocab/quantitykind/ElectricCurrent"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
- {
- "@id": "urn:nrel_example/nrel00000023"
- },
- {
- "@id": "urn:nrel_example/nrel00000060"
- },
- {
- "@id": "urn:nrel_example/nrel00000201"
- },
- {
- "@id": "urn:nrel_example/nrel00000232"
- },
- {
- "@id": "urn:nrel_example/nrel00000614"
- },
- {
- "@id": "urn:nrel_example/nrel00000843"
- },
- {
- "@id": "urn:nrel_example/nrel00000878"
- },
- {
- "@id": "urn:nrel_example/nrel00000886"
- },
- {
- "@id": "urn:nrel_example/nrel00000926"
- },
- {
- "@id": "urn:nrel_example/nrel00001083"
- },
+ "http://qudt.org/schema/qudt/hasUnit": [
{
- "@id": "urn:nrel_example/nrel00001146"
+ "@id": "http://qudt.org/vocab/unit/A"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000729"
+ "@value": "nrel00001075"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001028",
+ "@id": "urn:nrel_example/nrel00000413",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
+ "http://data.ashrae.org/standard223#Damper"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "http://qudt.org/vocab/quantitykind/PositiveDimensionlessRatio"
+ "@id": "urn:nrel_example/nrel00000927"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000950"
}
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/unit/PERCENT"
+ "@id": "urn:nrel_example/nrel00000013"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000103"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001028"
+ "@value": "nrel00000413"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000135",
+ "@id": "urn:nrel_example/nrel00001276",
"@type": [
- "http://data.ashrae.org/standard223#HeatingCoil"
+ "http://data.ashrae.org/standard223#FanCoilUnit"
],
"http://data.ashrae.org/standard223#contains": [
{
- "@id": "urn:nrel_example/nrel00000340"
+ "@id": "urn:nrel_example/nrel00000757"
},
{
- "@id": "urn:nrel_example/nrel00000734"
+ "@id": "urn:nrel_example/nrel00000777"
},
{
- "@id": "urn:nrel_example/nrel00000906"
+ "@id": "urn:nrel_example/nrel00001142"
}
],
"http://data.ashrae.org/standard223#hasConnectionPoint": [
{
- "@id": "urn:nrel_example/nrel00000051"
+ "@id": "urn:nrel_example/nrel00000100"
},
{
- "@id": "urn:nrel_example/nrel00000075"
+ "@id": "urn:nrel_example/nrel00000873"
+ }
+ ],
+ "http://data.ashrae.org/standard223#hasProperty": [
+ {
+ "@id": "urn:nrel_example/nrel00000141"
},
{
- "@id": "urn:nrel_example/nrel00000914"
+ "@id": "urn:nrel_example/nrel00000382"
},
{
- "@id": "urn:nrel_example/nrel00001250"
+ "@id": "urn:nrel_example/nrel00000711"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000765"
+ },
+ {
+ "@id": "urn:nrel_example/nrel00000959"
}
],
- "http://data.ashrae.org/standard223#hasProperty": [
+ "http://data.ashrae.org/standard223#hasRole": [
{
- "@id": "urn:nrel_example/nrel00000202"
+ "@id": "http://data.ashrae.org/standard223#Role-Cooling"
},
{
- "@id": "urn:nrel_example/nrel00000740"
+ "@id": "http://data.ashrae.org/standard223#Role-Heating"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000135"
+ "@value": "nrel00001276"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000820",
+ "@id": "urn:nrel_example/nrel00001153",
"@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
- ],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
- {
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
+ "http://data.ashrae.org/standard223#EnumeratedActuatableProperty"
],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00000820"
+ "@value": "nrel00001153"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001044",
+ "@id": "urn:nrel_example/nrel00000510",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
- "@id": "urn:nrel_example/nrel00000364"
- }
- ],
- "http://data.ashrae.org/standard223#hasPhysicalLocation": [
- {
- "@id": "urn:nrel_example/nrel00000553"
+ "@id": "urn:nrel_example/nrel00000961"
}
],
"http://data.ashrae.org/standard223#observes": [
{
- "@id": "urn:nrel_example/nrel00000555"
+ "@id": "urn:nrel_example/nrel00000475"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001044"
+ "@value": "nrel00000510"
}
]
},
{
- "@id": "urn:nrel_example/nrel00000379",
+ "@id": "urn:nrel_example/nrel00000336",
"@type": [
- "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
- ],
- "http://data.ashrae.org/standard223#hasEnumerationKind": [
- {
- "@id": "http://data.ashrae.org/standard223#EnumerationKind-AlarmStatus"
- }
+ "http://data.ashrae.org/standard223#PhysicalSpace"
],
- "http://www.w3.org/2000/01/rdf-schema#label": [
+ "http://data.ashrae.org/standard223#encloses": [
{
- "@value": "nrel00000379"
+ "@id": "urn:nrel_example/nrel00000818"
}
- ]
- },
- {
- "@id": "urn:nrel_example/nrel00001255",
- "@type": [
- "http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
- "http://qudt.org/schema/qudt/hasQuantityKind": [
+ "http://data.ashrae.org/standard223#hasProperty": [
{
- "@id": "http://qudt.org/vocab/quantitykind/Temperature"
- }
- ],
- "http://qudt.org/schema/qudt/hasUnit": [
+ "@id": "urn:nrel_example/nrel00000471"
+ },
{
- "@id": "http://qudt.org/vocab/unit/DEG_C"
+ "@id": "urn:nrel_example/nrel00000680"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001255"
+ "@value": "nrel00000336"
}
]
},
{
- "@id": "urn:nrel_example/nrel00001091",
+ "@id": "urn:nrel_example/nrel00001202",
"@type": [
- "http://data.ashrae.org/standard223#OutletConnectionPoint"
+ "http://data.ashrae.org/standard223#EnumeratedObservableProperty"
],
- "http://data.ashrae.org/standard223#hasMedium": [
+ "http://data.ashrae.org/standard223#hasEnumerationKind": [
{
- "@id": "http://data.ashrae.org/standard223#Medium-Water"
+ "@id": "http://data.ashrae.org/standard223#EnumerationKind-RunStatus"
}
],
"http://www.w3.org/2000/01/rdf-schema#label": [
{
- "@value": "nrel00001091"
+ "@value": "nrel00001202"
}
]
}
diff --git a/queries.toml b/queries.toml
index f8a37fc8..37cfdbfc 100644
--- a/queries.toml
+++ b/queries.toml
@@ -19,3 +19,14 @@ SELECT ?location ?sensor WHERE {
?sensor s223:hasObservationLocation ?location
}
"""
+
+[[ibal]]
+description="Zone/room temperature sensors"
+query="""
+SELECT ?location ?sensor WHERE {
+ ?sensor rdf:type/rdfs:subClassOf* s223:Sensor .
+ ?sensor s223:observes ?property .
+ ?property qudt:hasQuantityKind quantitykind:Temperature .
+ ?sensor s223:hasObservationLocation ?location
+}
+"""