From b210243e052aaea9a3055c2c65dd1985834f3eb6 Mon Sep 17 00:00:00 2001 From: Matt Steen Date: Thu, 11 Jan 2024 12:28:33 -0700 Subject: [PATCH] Delete models/guideline36-2021-4.3-parallel-variable.jsonld --- ...deline36-2021-4.3-parallel-variable.jsonld | 820 ------------------ 1 file changed, 820 deletions(-) delete mode 100644 models/guideline36-2021-4.3-parallel-variable.jsonld diff --git a/models/guideline36-2021-4.3-parallel-variable.jsonld b/models/guideline36-2021-4.3-parallel-variable.jsonld deleted file mode 100644 index ddea49a3..00000000 --- a/models/guideline36-2021-4.3-parallel-variable.jsonld +++ /dev/null @@ -1,820 +0,0 @@ -[ - { - "@id": "urn:ex/damper-actuator", - "@type": [ - "http://data.ashrae.org/standard223#Actuator" - ], - "http://data.ashrae.org/standard223#actuates": [ - { - "@id": "urn:ex/damper" - } - ], - "http://data.ashrae.org/standard223#commandedByProperty": [ - { - "@id": "urn:ex/damper-command" - } - ] - }, - { - "@id": "urn:ex/damper", - "@type": [ - "http://data.ashrae.org/standard223#Damper", - "http://data.ashrae.org/standard223/1.0/extensions/g36#Damper" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/damper-in" - }, - { - "@id": "urn:ex/damper-out" - } - ], - "http://data.ashrae.org/standard223#hasProperty": [ - { - "@id": "urn:ex/damper-command" - }, - { - "@id": "urn:ex/damper-position" - } - ] - }, - { - "@id": "urn:ex/", - "@type": [ - "http://www.w3.org/2002/07/owl#Ontology" - ] - }, - { - "@id": "urn:ex/out", - "@type": [ - "http://data.ashrae.org/standard223#OutletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/out-connection" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ], - "http://data.ashrae.org/standard223#hasProperty": [ - { - "@id": "urn:ex/discharge-air-temp" - } - ] - }, - { - "@id": "urn:ex/fan-out", - "@type": [ - "http://data.ashrae.org/standard223#OutletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-after-fan" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/supply-air-in-connection", - "@type": [ - "http://data.ashrae.org/standard223#Connection" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-valve-actuator", - "@type": [ - "http://data.ashrae.org/standard223#Actuator" - ], - "http://data.ashrae.org/standard223#actuates": [ - { - "@id": "urn:ex/reheat-coil-valve" - } - ], - "http://data.ashrae.org/standard223#commandedByProperty": [ - { - "@id": "urn:ex/reheat-coil-valve-command" - } - ] - }, - { - "@id": "urn:ex/out-connection", - "@type": [ - "http://data.ashrae.org/standard223#Connection" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/discharge-air-temp", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableObservableProperty" - ], - "http://data.ashrae.org/standard223#hasRole": [ - { - "@id": "http://data.ashrae.org/standard223#Role-Discharge" - } - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/Temperature" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/DEG_C" - } - ] - }, - { - "@id": "urn:ex/junction", - "@type": [ - "http://data.ashrae.org/standard223#Junction" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/junction-in-1" - }, - { - "@id": "urn:ex/junction-in-2" - }, - { - "@id": "urn:ex/junction-out" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/duct-after-fan", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Duct" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/junction-in-2", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-after-fan" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/return-air-from-plenum-in-connection", - "@type": [ - "http://data.ashrae.org/standard223#Connection" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/supply-air-in", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/supply-air-in-connection" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ], - "http://data.ashrae.org/standard223#hasProperty": [ - { - "@id": "urn:ex/supply-air-flow" - } - ] - }, - { - "@id": "urn:ex/parallel-fan-powered-terminal-unit-variable-volume-fan", - "@type": [ - "http://data.ashrae.org/standard223#FanPoweredTerminal", - "http://data.ashrae.org/standard223/1.0/extensions/g36#FanPoweredTerminal" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/out" - }, - { - "@id": "urn:ex/return-air-from-plenum-in" - }, - { - "@id": "urn:ex/supply-air-in" - } - ], - "http://data.ashrae.org/standard223#contains": [ - { - "@id": "urn:ex/damper" - }, - { - "@id": "urn:ex/fan" - }, - { - "@id": "urn:ex/junction" - }, - { - "@id": "urn:ex/reheat-coil" - }, - { - "@id": "urn:ex/reheat-coil-valve" - } - ] - }, - { - "@id": "urn:ex/pipe-hot-water-return-after-valve", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Pipe" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Water" - } - ] - }, - { - "@id": "urn:ex/return-air-from-plenum-in", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/return-air-from-plenum-in-connection" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-valve", - "@type": [ - "http://data.ashrae.org/standard223#Valve", - "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterValve" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/reheat-coil-valve-in" - }, - { - "@id": "urn:ex/reheat-coil-valve-out" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Water-HotWater" - } - ], - "http://data.ashrae.org/standard223#hasProperty": [ - { - "@id": "urn:ex/reheat-coil-valve-command" - }, - { - "@id": "urn:ex/reheat-coil-valve-position" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-water-out", - "@type": [ - "http://data.ashrae.org/standard223#OutletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/pipe-hot-water-supply" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Water" - } - ] - }, - { - "@id": "urn:ex/discharge-air-temp-sensor", - "@type": [ - "http://data.ashrae.org/standard223#Sensor" - ], - "http://data.ashrae.org/standard223#hasObservationLocation": [ - { - "@id": "urn:ex/out" - } - ], - "http://data.ashrae.org/standard223#observes": [ - { - "@id": "urn:ex/discharge-air-temp" - } - ] - }, - { - "@id": "urn:ex/duct-after-damper", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Duct" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/fan-start-cmd", - "@type": [ - "http://data.ashrae.org/standard223#EnumeratedActuatableProperty" - ], - "http://data.ashrae.org/standard223#hasEnumerationKind": [ - { - "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff" - } - ] - }, - { - "@id": "urn:ex/damper-in", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-before-damper" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ], - "http://data.ashrae.org/standard223#mapsTo": [ - { - "@id": "urn:ex/supply-air-in" - } - ] - }, - { - "@id": "urn:ex/fan-speed-cmd", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableActuatableProperty" - ], - "http://data.ashrae.org/standard223#hasAspect": [ - { - "@id": "http://data.ashrae.org/standard223#EnumerationKind-Speed" - } - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/PERCENT" - } - ] - }, - { - "@id": "urn:ex/damper-command", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableActuatableProperty" - ], - "http://data.ashrae.org/standard223#hasAspect": [ - { - "@id": "http://data.ashrae.org/standard223#EnumerationKind-Position" - } - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/PERCENT" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-in", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-before-reheat-coil" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ], - "http://data.ashrae.org/standard223#mapsTo": [ - { - "@id": "urn:ex/return-air-from-plenum-in" - } - ] - }, - { - "@id": "urn:ex/fan-in", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-after-reheat-coil" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-valve-out", - "@type": [ - "http://data.ashrae.org/standard223#OutletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/pipe-hot-water-return-after-valve" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Water" - } - ] - }, - { - "@id": "urn:ex/duct-before-reheat-coil", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Duct" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/damper-out", - "@type": [ - "http://data.ashrae.org/standard223#OutletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-after-damper" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-water-in", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/pipe-hot-water-return-after-valve" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Water" - } - ] - }, - { - "@id": "urn:ex/fan-speed-status", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableObservableProperty" - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/PERCENT" - } - ] - }, - { - "@id": "urn:ex/supply-air-flow-sensor", - "@type": [ - "http://data.ashrae.org/standard223#Sensor" - ], - "http://data.ashrae.org/standard223#hasObservationLocation": [ - { - "@id": "urn:ex/supply-air-in" - } - ], - "http://data.ashrae.org/standard223#observes": [ - { - "@id": "urn:ex/supply-air-flow" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-valve-position", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableObservableProperty" - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/PERCENT" - } - ] - }, - { - "@id": "urn:ex/supply-air-flow", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableObservableProperty" - ], - "http://data.ashrae.org/standard223#hasRole": [ - { - "@id": "http://data.ashrae.org/standard223#Role-Supply" - } - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/FT3-PER-MIN" - } - ] - }, - { - "@id": "urn:ex/reheat-coil", - "@type": [ - "http://data.ashrae.org/standard223#HeatingCoil", - "http://data.ashrae.org/standard223/1.0/extensions/g36#HotWaterCoil" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/reheat-coil-air-out" - }, - { - "@id": "urn:ex/reheat-coil-in" - }, - { - "@id": "urn:ex/reheat-coil-water-in" - }, - { - "@id": "urn:ex/reheat-coil-water-out" - } - ], - "http://data.ashrae.org/standard223#hasRole": [ - { - "@id": "http://data.ashrae.org/standard223#Role-Heating" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-air-out", - "@type": [ - "http://data.ashrae.org/standard223#OutletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-after-reheat-coil" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/pipe-hot-water-supply", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Pipe" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Water" - } - ] - }, - { - "@id": "urn:ex/duct-before-damper", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Duct" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/damper-position", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableObservableProperty" - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/PERCENT" - } - ] - }, - { - "@id": "urn:ex/pipe-hot-water-return-before-valve", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Pipe" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Water" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-valve-command", - "@type": [ - "http://data.ashrae.org/standard223#QuantifiableActuatableProperty" - ], - "http://data.ashrae.org/standard223#hasAspect": [ - { - "@id": "http://data.ashrae.org/standard223#EnumerationKind-Position" - } - ], - "http://qudt.org/schema/qudt/hasQuantityKind": [ - { - "@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio" - } - ], - "http://qudt.org/schema/qudt/hasUnit": [ - { - "@id": "http://qudt.org/vocab/unit/PERCENT" - } - ] - }, - { - "@id": "urn:ex/fan-start-status", - "@type": [ - "http://data.ashrae.org/standard223#EnumeratedObservableProperty" - ], - "http://data.ashrae.org/standard223#hasEnumerationKind": [ - { - "@id": "http://data.ashrae.org/standard223#EnumerationKind-OnOff" - } - ] - }, - { - "@id": "urn:ex/fan", - "@type": [ - "http://data.ashrae.org/standard223#Fan", - "http://data.ashrae.org/standard223/1.0/extensions/g36#FanWithVFD" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/fan-in" - }, - { - "@id": "urn:ex/fan-out" - } - ], - "http://data.ashrae.org/standard223#hasProperty": [ - { - "@id": "urn:ex/fan-speed-cmd" - }, - { - "@id": "urn:ex/fan-speed-status" - }, - { - "@id": "urn:ex/fan-start-cmd" - }, - { - "@id": "urn:ex/fan-start-status" - } - ] - }, - { - "@id": "urn:ex/reheat-coil-valve-in", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/pipe-hot-water-return-before-valve" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Water" - } - ] - }, - { - "@id": "urn:ex/junction-out", - "@type": [ - "http://data.ashrae.org/standard223#OutletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/out-connection" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ], - "http://data.ashrae.org/standard223#mapsTo": [ - { - "@id": "urn:ex/out" - } - ] - }, - { - "@id": "urn:ex/junction-in-1", - "@type": [ - "http://data.ashrae.org/standard223#InletConnectionPoint" - ], - "http://data.ashrae.org/standard223#cnx": [ - { - "@id": "urn:ex/duct-after-damper" - } - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - }, - { - "@id": "urn:ex/duct-after-reheat-coil", - "@type": [ - "http://data.ashrae.org/standard223#Connection", - "http://data.ashrae.org/standard223#Duct" - ], - "http://data.ashrae.org/standard223#hasMedium": [ - { - "@id": "http://data.ashrae.org/standard223#Medium-Air" - } - ] - } -] \ No newline at end of file