diff --git a/validation/24-11-2023-boundary-clock/report.md b/validation/24-11-2023-boundary-clock/report.md index 2f9f8f1fd..341b5c27c 100644 --- a/validation/24-11-2023-boundary-clock/report.md +++ b/validation/24-11-2023-boundary-clock/report.md @@ -16,7 +16,7 @@ All machines except for the grandmaster used statime commit hash c8561310 as the ## Test procedure -For each test, all machines were turned on in their respective configuration, and the entire setup was then given at least 2 hours to fully stabilize. Then the time difference between the grandmaster and +For each test, all machines were turned on in their respective configuration, and the entire setup was then given at least 2 hours to fully stabilize. Then the time difference between the grandmaster and the i210 were measured every second over a time period of 2 hours. For this data we then calculated both the mean and the sample standard deviation. The mean represents a measure of assymetry in the setup, and will be ignored in the rest of this text as it can be easily corrected for. The sample standard deviation provides us with a measure of the quality of the synchronization.