The XML file format occasionally goes through changes and old config
files will no longer work. Each config file specifies which version of
the file format is in use in the opening tag, e.g.,
<DYNAMOconfig version="1.X.X">
This file details the changes, and how to upgrade an old configuration.
v1.4.0 - Major overhaul of the XML file format. Binary sections
disabled. Particle properties added. Aspect ratio and units
removed, replaced with Simulation size tag. BoundedPQMinMax
Sorter types now have a number at the end to denominate the
MinMax heap size. The main node of the XML file is now DynamOconfig.
v1.3.0 - The binary/XML format has been changed to now store particle
states. If you want to convert a "text" v1.2.0 file, just
change the version to 1.3.0. If you have a binary file, you
must first convert it to text format using an old version of
dynamod (dynamod --text config.old.xml.bz2 -o
config.old.text.xml.bz2), and then change the version tag by
hand. It should work then. A suitably old version of dynamo is
tagged as XML-1.2.0-last in the git tree.
- The Newtonian gravity liouvillean now uses a vector form of
the gravity. The Gravity and GravityDim attributes are
ignored and a vector is now required E.g. <g x="0" y="-1" z="0"/>
v1.2.0 The appended binary tags are now split for extra data,
extendable and handled neatly in the code. As such
AppendedBinaryData is now AppendedBinaryPosVel, and there is an
extra AppendedBinaryOrientation
v1.1.3 The document is now valid XML moved the AppendedBinaryData into
the document tags and used a trick to fool the XML parser.
- The binary data now contains the orientational data.
- There is also an attribute in the particleData to indicate if
the binary stream contains orientational data,
v1.1.2 Renamed EOXML to AppendedBinaryData and made it valid XML. The
base64 now tolerates spaces and newlines but not '<' characters
as these indicate a new XML tag
v1.1.1 Required the <EOXML /> tag at the end of the XML to indicate
the start of the base64 encoded binary data section - Removed
Backwards compatibility for configs using Particle tags, should
be Pt now, and removed ISSSconfig now the switch to
DYNAMOconfig is complete
v1.1 Moved the orientational liouvilleans data to inside the
liouvillean tags instead of the particle data, this only effect
the orientational liouvillean
v1.0 Initial start of XML file format version control