Notifications
You must be signed in to change notification settings - Fork 1
/
39_VALVES.pm
478 lines (429 loc) · 22.3 KB
/
39_VALVES.pm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
# $Id: 39_VALVES.pm 2022-08-05 Beta-User $
####################################################################################################
#
# 39_VALVES.pm
#
# originally developed by Florian Duesterwald
#
# heating valves average, with some adjust and ignore options
# http://forum.fhem.de/index.php/topic,24658.0.html
# refer to mail a.T. duesterwald do T info if necessary
#
# thanks to cwagner for testing and a great documentation of the module:
# http://www.fhemwiki.de/wiki/Raumbedarfsabh%C3%A4ngige_Heizungssteuerung
# http://www.fhemwiki.de/wiki/VALVES
# thanks to stromer-12 for fixing attr probs
#
# This file is free contribution and not part of fhem.
#
# Fhem is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 2 of the License, or
# (at your option) any later version.
#
# Fhem is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with fhem. If not, see <http://www.gnu.org/licenses/>.
#
####################################################################################################
package FHEM::Automation::VALVES; ## no critic 'Package declaration'
use strict;
use warnings;
use Time::HiRes qw( gettimeofday );
use List::Util qw( sum );
use Scalar::Util qw( looks_like_number );
use GPUtils qw(GP_Import);
BEGIN {
# Import from main context
GP_Import(
qw(
defs
init_done
readingFnAttributes
readingsSingleUpdate
readingsBeginUpdate readingsEndUpdate
readingsBulkUpdate readingsBulkUpdateIfChanged
setReadingsVal
AttrVal InternalVal
ReadingsVal ReadingsTimestamp
Log3
addToDevAttrList
parseParams
InternalTimer RemoveInternalTimer
CommandSet CommandDeleteReading CommandDeleteAttr
devspec2array
IsDisabled
)
);
}
sub ::VALVES_Initialize { goto &Initialize }
sub Initialize {
my $hash = shift // return;
$hash->{DefFn} = \&Define;
$hash->{UndefFn} = \&Undefine;
$hash->{SetFn} = \&Set;
$hash->{GetFn} = \&Get;
$hash->{AttrFn} = \&Attr;
my $attrList = "valvesPollInterval:1,2,3,4,5,6,7,8,9,10,11,15,20,25,30,45,60,90,120,240,480,900" . " valvesDeviceList valvesDeviceReading valvesIgnoreLowest valvesIgnoreHighest valvesIgnoreDeviceList" . " valvesPriorityDeviceList valvesInitialDelay";
#my $i = 0;
$hash->{AttrList} = "disable:0,1 disabledForIntervals $readingFnAttributes $attrList";
return;
}
sub Define {
my $hash = shift // return;
my $def = shift // return;
my ( $name, $TYPE, $tomuch ) = split m{\s+}xms, $def;
return 'Wrong syntax: use define <name> VALVES' if defined $tomuch || !defined $TYPE;
Log3( $name, 4, "VALVES $name has been defined" );
readingsBeginUpdate($hash);
readingsBulkUpdate( $hash, 'state', 'initialized' );
readingsBulkUpdate( $hash, 'busy', 0 + gettimeofday() ); #waiting for attr check
readingsEndUpdate( $hash, $init_done );
#first run after 61 seconds, wait for other devices
InternalTimer( gettimeofday() + AttrVal( $name, 'valvesInitialDelay', 61 ), \&VALVES_GetUpdate, $hash, 0 ) if !$init_done;
VALVES_GetUpdate($hash) if $init_done && !AttrVal( $name, 'disable', 0 );
return;
}
sub Undefine {
my $hash = shift // return;
RemoveInternalTimer($hash);
return;
}
sub Get {
my ( $hash, @arr ) = @_;
my $name = $hash->{NAME};
my $get = $arr[1];
if ( $get eq 'attrHelp' ) { return _valvesAttribs( 'help', $arr[2] ); }
my @stmgets = keys %{ $hash->{READINGS} };
$get = '?' if $get ne '?' && !( grep {m{$get}x} ( @stmgets, 'attrHelp', 'state', 'html' ) );
if ( $get ne '?' ) {
return $get . ': ' . ReadingsVal( $name, $get, 'Unknown at line ' . __LINE__ );
}
my $usage = "Unknown argument $get, choose one of";
for (@stmgets) {
$usage .= " " . $_ . ":noArg";
}
$usage .= " attrHelp:";
for ( _valvesAttribs( 'keys', '' ) ) {
$usage .= ",$_";
}
return $usage;
}
sub Set {
my ( $hash, @arr ) = @_;
my $name = shift @arr;
return 'no set value specified' if !@arr;
if ( $arr[0] eq 'reset' ) {
Log3( $name, 4, "VALVES set $name " . join( q{ }, @arr ) );
for ( keys( %{ $hash->{READINGS} } ) ) {
CommandDeleteReading( undef, "$name $_" );
}
return;
}
my $setList = 'reset:noArg';
return "Unknown argument $arr[0], choose one of $setList";
}
sub Attr {
my ( $cmd, $name, $attrName, $attrVal ) = @_;
my $hash = $defs{$name};
#special attr valvesDeviceList #valvesDeviceList: addToAttrList
if ( $attrName eq 'valvesDeviceList' ) {
if ( length($attrVal) > 2 ) {
Log3( $name, 4, "VALVES $name attribute-value [$attrName] = $attrVal changed" );
for ( devspec2array($attrVal) ) { # split m{,}x,$attrVal ) {
#addToDevAttrList("$name","valves".$_."Gewichtung",'VALVES');
addToDevAttrList( "$name", "valves" . $_ . "Weighting", 'VALVES' );
}
VALVES_GetUpdate($hash) if $init_done && !IsDisabled($name);
}
else {
Log3( $name, 3, "VALVES $name attribute-value [$attrName] = $attrVal wrong, string min length 2" ) if $attrVal;
}
return;
}
#validate special attr valvesPollInterval
if ( $attrName eq 'valvesPollInterval' ) {
if ( $attrVal >= 1 && $attrVal <= 900 ) {
Log3( $name, 4, "VALVES $name attribute-value [$attrName] = $attrVal changed" );
VALVES_GetUpdate($hash) if $init_done && !AttrVal( $name, 'disable', 0 );
}
else {
Log3( $name, 3, "VALVES $name attribute-value [$attrName] = $attrVal wrong, use seconds >1 as float (max 900)" );
return "$attrVal is not a number or within allowed range!" if $init_done;
}
return;
}
if ( $attrName eq 'valvesDeviceReading' ) {
delete $hash->{helper}->{valvesDeviceReading};
if ( length($attrVal) > 2 ) {
my ( $unnamedParams, $namedParams ) = parseParams($attrVal);
$hash->{helper}->{valvesDeviceReading} = $namedParams;
$hash->{helper}->{valvesDeviceReading}->{valvesDeviceReading} = $unnamedParams->[0] if defined $unnamedParams->[0];
Log3( $name, 4, "VALVES $name attribute-value [$attrName] = $attrVal changed" );
VALVES_GetUpdate($hash) if $init_done;
}
else {
Log3( $name, 3, "VALVES $name attribute-value [$attrName] = $attrVal wrong, string min length 2" ) if $attrVal;
}
return;
}
if ( $attrName eq 'disable' ) {
RemoveInternalTimer($hash) if $cmd ne 'del';
InternalTimer( gettimeofday(), \&VALVES_GetUpdate, $hash, 0 ) if $cmd eq 'del' || !$attrVal && $init_done;
return;
}
if ( $attrName eq 'valvesInitialDelay' ) {
RemoveInternalTimer($hash) if !$init_done;
return if AttrVal( $name, 'disable', 0 );
if ( !looks_like_number($attrVal) ) {
return "$attrVal is not a number!" if $init_done;
$attrVal = 61;
}
InternalTimer( gettimeofday() + $attrVal, \&VALVES_GetUpdate, $hash, 0 ) if !$init_done;
}
#other attribs
if ( $attrName =~ m{\Avalves\d+}x ) {
if ( !defined $attrVal ) {
CommandDeleteAttr( undef, "$name attrName" );
Log3( $name, 4, "VALVES $name: attribute [$attrName] deleted" );
}
}
else {
Log3( $name, 4, "VALVES $name: attribute-value [$attrName] = $attrVal changed" ) if $attrVal;
}
return;
}
sub VALVES_GetUpdate {
my $hash = shift // return;
my $name = $hash->{NAME};
my $valvesPollInterval = AttrVal( $name, 'valvesPollInterval', 10 );
if ( $valvesPollInterval ne 'off' ) {
RemoveInternalTimer($hash);
$valvesPollInterval = 10 if !looks_like_number($valvesPollInterval);
InternalTimer( gettimeofday() + $valvesPollInterval, \&VALVES_GetUpdate, $hash, 0 ) if !AttrVal( $name, 'disable', 0 );
}
return if IsDisabled($name);
if ( AttrVal( $name, 'valvesDeviceList', 'none' ) eq 'none' ) {
readingsSingleUpdate( $hash, 'state', 'missing attr valvesDeviceList', 1 );
RemoveInternalTimer($hash);
return;
}
#check all attr at first loop
if ( ReadingsVal( $name, 'busy', 'done' ) ne 'done' ) { #"waiting for attr check"
if ( ( gettimeofday() - AttrVal( $name, 'valvesInitialDelay', 61 ) ) > ReadingsVal( $name, 'busy', 0 ) ) {
for ( devspec2array( AttrVal( $name, 'valvesDeviceList', '' ) ) ) { # split m{,}x, AttrVal($name,'valvesDeviceList','') ) {
#addToDevAttrList("$name",'valves'.$_.'Gewichtung','VALVES');
addToDevAttrList( "$name", 'valves' . $_ . 'Weighting', 'VALVES' );
}
CommandDeleteReading( undef, "$name busy" );
}
}
my ( %valveDetail, %valveShort, @raw_average, $pos, $prio, @prios );
my $valvesIgnoreDeviceList = AttrVal( $name, 'valvesIgnoreDeviceList', '0' );
for my $dev ( devspec2array( AttrVal( $name, 'valvesDeviceList', '' ) ) ) {
#check ignorelist
next if $valvesIgnoreDeviceList =~ m/$dev/x;
#get val
my $posRead = $hash->{helper}->{valvesDeviceReading}->{ InternalVal( $dev, 'TYPE', 'none' ) } // $hash->{helper}->{valvesDeviceReading}->{valvesDeviceReading} // 'valveposition';
$pos = ReadingsVal( $dev, $posRead, 'err' );
if ( !defined $pos || $pos eq 'err' || $pos eq 'lime-protection' ) {
Log3( $name, 4, "VALVES $name " . $_ . " [$pos] DeviceReading not present" );
next;
}
#$pos =~ s/%//x;
$pos = $pos =~ m{(-?\d+(\.\d+)?)}x ? $1 : -1;
push @raw_average, $pos;
#calc prio
$prio = AttrVal( $name, 'valves' . $dev . 'Weighting', AttrVal( $name, 'valves' . $dev . 'Gewichtung', 1 ) );
#fill hash
$valveDetail{$dev} = [ ( $pos, ReadingsTimestamp( $dev, $posRead, 0 ) ) ];
$valveShort{$dev} = $pos * $prio;
}
#ignore highest/lowest N values
my @sorted = sort { $valveShort{$a} <=> $valveShort{$b} } keys %valveShort;
if ( !@sorted ) {
readingsSingleUpdate( $hash, 'state', 'attr valvesDeviceList is empty', 1 );
return;
}
my $valvesIgnoreLowest = AttrVal( $name, 'valvesIgnoreLowest', 0 );
while ( $valvesIgnoreLowest > 0 ) {
shift @sorted;
$valvesIgnoreLowest--;
}
my $valvesIgnoreHighest = AttrVal( $name, 'valvesIgnoreHighest', 0 );
while ( $valvesIgnoreHighest > 0 ) {
pop @sorted;
$valvesIgnoreHighest--;
}
return if !@sorted;
#fill readings, bypass usual way to conserve valveposition timestamps
for (@sorted) {
setReadingsVal( $hash, 'valve_' . $_, $valveShort{$_}, $valveDetail{$_}[1] );
push @prios, AttrVal( $name, 'valves' . $_ . 'Weighting', AttrVal( $name, 'valves' . $_ . 'Gewichtung', 1 ) );
}
#set min and max from sorted
readingsBeginUpdate($hash);
readingsBulkUpdateIfChanged( $hash, 'valve_min', $valveShort{ $sorted[0] }, 1 );
readingsBulkUpdateIfChanged( $hash, 'valve_max', $valveShort{ $sorted[-1] }, 1 );
my $valvesPriorityDeviceList = AttrVal( $name, 'valvesPriorityDeviceList', '0' );
for my $dev ( keys %valveDetail ) {
if ( !exists $valveShort{$dev} ) {
$valveShort{$dev} = 'ignored';
}
#create double hash entry for prio dev
if ( $valvesPriorityDeviceList =~ m/$dev/x ) {
$valveShort{ $dev . 'P' } = $valveShort{$dev};
push @sorted, $dev . 'P';
push @prios, AttrVal( $name, 'valves' . $dev . 'Weighting', AttrVal( $name, 'valves' . $dev . 'Gewichtung', 1 ) );
}
readingsBulkUpdate( $hash, 'valveDetail_' . $dev, 'pos:' . $valveDetail{$dev}[0] . ' calc:' . $valveShort{$dev} . ( $valvesPriorityDeviceList =~ m/$dev/x ? '-priority' : '' ) . ' time:' . $valveDetail{$dev}[1], 0 );
}
my $state;
for (@sorted) {
$state += $valveShort{$_};
}
my $corr = sum(@prios) / @prios;
$state = sprintf "%.0f", $state / @sorted / $corr;
if ( ReadingsVal( $name, 'state', 'err' ) ne $state ) {
readingsBulkUpdate( $hash, 'valve_average', $state, 1 );
readingsBulkUpdate( $hash, 'state', $state, 1 );
}
$state = 0;
for (@raw_average) {
$state += $_;
}
$state = sprintf "%.0f", $state / @raw_average;
readingsBulkUpdateIfChanged( $hash, 'raw_average', $state, 1 );
readingsEndUpdate( $hash, 1 );
return;
}
sub _valvesAttribs {
#usage: _valvesAttribs("type","stmVarName")
# "keys" || "default" || "type" || "help" ,<keyname>
my ( $type, $reqKey ) = @_;
my %attribs = (
"valvesInitialDelay" => [ ( "61", "int", "Waiting time after FHEM start (or Define) before first calculation will be started", "Zeitintervall nach FHEM-Start oder Dev.-Define bevor die Berechnung gestartet wird" ) ],
"valvesPollInterval" => [ ( "10", "int", "Zeitintervall nach dem FHEM die Daten versucht zu aktualisieren", "Zeitintervall nach dem FHEM die Daten versucht zu aktualisieren" ) ],
"valvesDeviceList" => [ ( "none", "string", "Liste aller Heizungsthermostate mit Komma getrennt ohne Leerzeichen", "Liste aller Heizungsthermostate mit Komma getrennt ohne Leerzeichen" ) ],
"valvesDeviceReading" => [ ( "valveposition", "string", "Reading das die Ventilposition zeigt, default: valveposition", "Reading das die Ventilposition zeigt, default: valveposition" ) ],
"valvesIgnoreLowest" => [ ( "0", "int", "ignoriere die niedrigsten N Thermostate", "ignoriere die niedrigsten N Thermostate" ) ],
"valvesIgnoreHighest" => [ ( "0", "int", "ignoriere die höchsten N Thermostate", "ignoriere die höchsten N Thermostate" ) ],
"valvesIgnoreDeviceList" => [ ( "0", "string", "Ignoriere diese Devicenamen", "Ignoriere diese Devicenamen" ) ],
"valvesPriorityDeviceList" => [ ( "0", "string", "Thermostate in dieser Liste werden doppelt gezählt", "Thermostate in dieser Liste werden doppelt gezählt" ) ],
"valves<Devicename>Gewichtung" => [ ( "1", "float", 'Individual weighting factor for each thermostate. May e.g. be used to compensate hydraulic problems in the heating system.', "Für jedes Thermostat kann ein individueller Gewichtungsfaktor multipliziert werden. So kann zB ein schlechter hydraulischer Abgleich berücksichtigt werden" ) ],
"valves<Devicename>Weighting" => [ ( '1', 'float', 'Individual weighting factor for each thermostate. May e.g. be used to compensate hydraulic problems in the heating system.', "Für jedes Thermostat kann ein individueller Gewichtungsfaktor multipliziert werden. So kann zB ein schlechter hydraulischer Abgleich berücksichtigt werden" ) ],
disable => [ ( "0", "int", 'Stop calculations and freeze values', "Berechnung anhalten und einfrieren" ) ],
);
return keys %attribs if $type eq 'keys';
return $attribs{$reqKey}[0] if $type eq 'default';
return $attribs{$reqKey}[1] if $type eq 'type';
if ( $type eq 'description' ) {
return $attribs{$reqKey}[2] if AttrVal( 'global', 'language', 'EN' ) ne 'DE';
return $attribs{$reqKey}[3];
}
if ( $type eq 'help' ) {
return "attrHelp for " . $reqKey . ":\n default:" . $attribs{$reqKey}[0] . " type:" . $attribs{$reqKey}[1] . " \ndescription:" . $attribs{$reqKey}[2];
}
return '_ attribs?';
}
1;
__END__
=pod
=encoding utf8
=item helper
=item summary generate a virtual valve position based on multiple thermostat devices
=item summary_DE Generiert eine virtuelle Ventilöffnung aus eine Mehrzahl von Heizungsventilen
=begin html
<a id="VALVES"></a>
<h3>VALVES</h3>
<ul>
German docu is available in <a href="http://www.fhemwiki.de/wiki/VALVES">FHEM Wiki</a>.<br>
<a id="VALVES-define"></a>
<h4>Define</h4>
<ul>
<code>define <name> VALVES</code><br>
<br>
Defines a virtual device for VALVES calculations based on multiple thermostat devices<br>
</ul>
<ul>
How to use VALVES after define:
<li>First tell VALVES, which real valve devices shall be used for calculation as described in <a href="#VALVES-attr-valvesDeviceList">valvesDeviceList</a> (mandatory!).</li>
If that works you should be able to (optionally) set additional <a href="#VALVES-attr-valvesDevicenameWeighting">valves<Devicename>Weighting</a> values.
<li>Set appropriate <a href="#VALVES-attr-valvesDeviceReading">valvesDeviceReading</a> (most likely will be necessary)</li>
<li>(Optionally) exclude not needed devices using <a href="#VALVES-attr-valvesIgnoreDeviceList">valvesIgnoreDeviceList</a></li>
<li>(Optionally) set values in <a href="#VALVES-attr-valvesIgnoreLowest">valvesIgnoreLowest</a> and/or <a href="#VALVES-attr-valvesIgnoreHighest">valvesIgnoreHighest</a></li>
<li>(Optionally) set emphasis on single devices by setting individual <a href="#VALVES-attr-valvesDevicenameWeighting">valves<Devicename>Weighting</a> and/or including them in <a href="#VALVES-attr-valvesIgnoreLowest">valvesPriorityDeviceList</a> values</li>
</ul>
<a id="VALVES-readings"></a>
<ul>
How VALVE calculates and handles readings:
<li>After FHEM startup, VALVES will wait <a href="#VALVES-attr-valvesInitialDelay">valvesInitialDelay</a> and then will do a calculation every <a href="#VALVES-attr-valvesPollInterval">valvesPollInterval</a> seconds using the follwoing scheme:
<ul>
<li>Get a list of valve value and timestamp for each device (not ignored by name)</li>
<li>Delete lowest and highest valves/devices from this list</li>
<li>recalculate valve positions according to weighting settings</li>
<li>Double priority devices in the list</li>
<li>Derive readings (main and debug)</li>
</ul>
</li>
<li>Main readings (triggering when changed) are <i>valve_min</i>, <i>valve_max</i>, <i>valve_average</i>, <i>raw_average</i> and <i>state</i>.</li>
<li>Debug readings <i>valve<Devicename></i> shows the calculated virtual valve position, <i>valveDetail_<Devicename></i> the real and calculated position and the timestamp of the original reading.</li>
</ul>
<a id="VALVES-set"></a>
<h4>Set </h4>
<ul>
<a id="VALVES-set-reset"></a>
<li><b>reset</b></li>
deletes already calculated readings and starts from the scratch
</ul>
<a id="VALVES-get"></a>
<h4>Get</h4>
<ul>
<a id="VALVES-get-reading"></a>
<li><b><reading></b></li>
<code>get <name> <reading></code><br>
Any of the actual reading values.<br><br>
<a id="VALVES-get-attrHelp"></a>
<li><b>attrHelp <attribute></b></li>
<code>get <name> attrHelp <attribute></code><br>
Get help text to named attribute.<br>
</ul>
<a id="VALVES-attr"></a>
<h4>Attributes</h4>
<ul>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
<a id="VALVES-attr-valvesInitialDelay"></a>
<li><b>valvesInitialDelay <delay></b><br>
Waiting time after FHEM start (or define) before first calculation will be started. Defaults to 61.</li>
<a id="VALVES-attr-valvesPollInterval"></a>
<li><b>valvesPollInterval <interval></b><br>
Polling interval (in seconds, between 1 to 900) between each attempt to update values. Defaults for compability reasons to 10.</li>
<a id="VALVES-attr-valvesDeviceList"></a>
<li><b>valvesDeviceList <devspec></b><br>
<a href="#devspec">devspec</a> is as usual, e.g. use a comma-separated list (no spaces allowed!) of all thermostate devices to make part of calculations</li>
<a id="VALVES-attr-valvesDeviceReading"></a>
<li><b>valvesDeviceReading [<positionreading>] ;</b><br>
Reading to base calculations upon, default: valveposition. You may set a key value list as follows as well with device-TYPE and reading name pairs like e.g.:<br>
<code>attr <device> valvesDeviceReading CUL_HM=ValvePosition ZWave=reportedState</code></li>
<a id="VALVES-attr-valvesIgnoreLowest"></a>
<li><b>valvesIgnoreLowest <number></b><br>
ignore the <number> of the thermostate devices with (actual) lowest valve values.</li>
<a id="VALVES-attr-valvesIgnoreHighest"></a>
<li><b>valvesIgnoreHighest <number></b><br>
ignore the <number> of the thermostate devices with (actual) highest valve values.</li>
<a id="VALVES-attr-valvesIgnoreDeviceList"></a>
<li><b>valvesIgnoreDeviceList <deviceA,deviceB,[....]></b><br>
ignore the listed thermostate devices (comma separated).</li>
<a id="VALVES-attr-valvesPriorityDeviceList"></a>
<li><b>valvesPriorityDeviceList <regex></b><br>
Thermostates matching the regex will be doubled in the calculation process</li>
<a id="VALVES-attr-valvesDevicenameWeighting" data-pattern="valves.*Weighting"></a>
<li><b>valves<Devicename>Weighting <float value></b><br>
Individual weighting factor (lfoat value) for each thermostate. May e.g. be used to compensate hydraulic problems in the heating system</li>
</ul>
</ul>
=end html