The NodOn SIN-2-2-01 is a 2-channel ON/OFF lighting relay switch.
As the EEP profile D2-01-12 was not available in the enocean lib (former days), the device is switched via standard rocker switch commands (EEP F6-02-02). State changes are read automatically via EEP D2-01-01. Maybe these notifications have to be switched on.
Unfortunatly the device got broken, so changes cannot be tested and there is not support possible any more.
- Switch and get notifications about state changes.
- Output JSON
- on, off, 0, 100, toggle, update
- learn: Teach the device. Bring the device in teach mode and then send "learn".
- All commands are case in-sensitive.
Configure a separate device for each channel!
devices:
channel1:
enocean_target: 0x01111111 # Enocean ID of the relay switch
enocean_sender: 0x22222228 # your Enocean sender ID (specific to you USB device!)
device_type: "NodonSin22"
actor_channel: 0
mqtt_channel_state: "test/channel1/state"
mqtt_retain: True
mqtt_channel_cmd: "test/channel1/cmd"
channel2:
enocean_target: 0x01111111 # Enocean ID of the relay switch
enocean_sender: 0x22222229 # your Enocean sender ID (specific to you USB device!)
device_type: "NodonSin22"
actor_channel: 1
mqtt_channel_state: "test/channel2/state"
mqtt_retain: True
mqtt_channel_cmd: "test/channel2/cmd"