Expand Up @@ -98,6 +98,10 @@ cd ~/Calibration_ws
source devel/setup.bash
roslaunch multi_calibration auto_calibration.launch directory:="[file position]" camera_intrinsic:=1
```
The motion of the robot arm will be like:
<p align="center">
<img src="gifs/intr_motion.gif" alt="Image Viewer Panel" width="500"/>
</p>

#### 1.2.2 Calibration Process
Go to the folder where images collected from last step are saved
Expand Down Expand Up @@ -142,41 +146,28 @@ rosrun camera_model Calibration -w 7 -h 10 -s 5 -i ./ -v --camera-model PINHOLE
Update the pinhole calibration result (fx fy cx cy) to `rectCameraMatrix` in `~/Calibration_ws/src/multi_calibration/cfg/calib_params.yaml`

#### 1.2.3 Result Checking
To check the calibration result, run all the same four terminals with auto_calibration in camera_rect_intrinsic mode
To check the calibration result, run **auto_calibration.launch** again with **camera_intrinsic:=2** shown below.

```shell
cd ~/Calibration_ws
source devel/setup.bash
roslaunch multi_calibration auto_calibration.launch directory:="[file position]" camera_rect_intrinsic:=1
roslaunch multi_calibration auto_calibration.launch directory:="[file position]" camera_intrinsic:=2
```

In another terminal window open rqt.

```shell
rqt
```

Go to Plugins -> Visualization -> Image Viewer
Then you can see the preset ```rqt``` window which shows both raw image and rect_image.

<p align="center">
<img src="images/rqt1.png" alt="Image Viewer" width="800"/>
<img src="images/test1.png" alt="Image Viewer Panel" width="600"/>
</p>


In the Image Viewer panel switch to the `blaser_cam/image_rect_node` topic, this would display the undistorted image. All the straight lines in real world should appear as perfectly straight on the image.

<p align="center">
<img src="images/rqt0.png" alt="Image Viewer Panel" width="800"/>
</p>

## 2. Hand-eye Calibration
![Flowchart](images/Hand_eye_calibration.png)

### 2.1 Hardware needed
* UR robot arm
* Camera holder([Example](https://drive.google.com/file/d/1i7l1ikb1o2ocoi0iMsCJhSHDmBsIzraE/view?usp=sharing))
* April tag holder([Example](https://drive.google.com/file/d/12sZWZGFeq9ehgpnKUAZS80BMfkZedMsY/view?usp=sharing))
* [Hand eye calibration ipynb](Hand_eye.ipynb)
* [Hand eye calibration ipynb](Hand_eye.ipynb) (no need after update)

### 2.2 Calibration process
#### 2.2.1 Tag Size Measurement
Expand All @@ -188,7 +179,11 @@ Note: The tag size should not be measured from the outside of the tag. The tag s
<img src="images/tag_size_example.png" alt="Tag size example" width="200"/>
</p>

#### 2.2.2 Tag Measurement



#### 2.2.2 Calibration Process

- Getting the *camera to Tag* transform:

- Start the ximea camera node
Expand All @@ -205,22 +200,33 @@ Note: The tag size should not be measured from the outside of the tag. The tag s
cd ~/Calibration_ws
source devel/setup.bash
roslaunch multi_calibration auto_calibration.launch hand_eye:=1
```
Now the **camera to Tag** transform can be viewed by echoing the **tf** rostopic.

- Getting the *end-effector to Tag* transform: Use the CAD of your April tag holder and Camera holder to obtain the transform.
#### 2.2.3 Calibration Process
After properly setting up the Apriltag pose estimation pipeline(that includes image undistortion and publishing updated rectified camera matrix), the **camera to Tag** transform should be available to you.

With the measurement of **camera to Tag** and **end-effector to Tag**, input them into
[Jupyter Notebook for Hand-eye calibration](https://drive.google.com/file/d/1x8It3NmqM_Qm07OM-dieFRudrayFTtfS/view?usp=sharing) and get the **EE to Camera** transform matrix.
[Calibration yaml file](https://github.com/Flowerst-0416/UR_arm_camera_calibration/blob/main/multi_calibration/cfg/handeye_params.yaml) and get the **EE to Camera** transform matrix which will output to [Handeye result colletion file](https://github.com/Flowerst-0416/UR_arm_camera_calibration/blob/main/multi_calibration/cfg/handeye_result.yaml)

#### 2.2.3 Result Checking

After launch the ```auto_calibration.launch``` in handeye mode, an rviz will show out to help you evaluate the tag detection and measurement.

<p align="center">
<img src="images/handeye_evl.png" alt="rviz window" width="600"/>
</p>

The calculattion result will also shown in the matplot which you can use it to compare with the predict value and do futher evaluation.

<p align="center">
<img src="images/handeye_result_shown.png" alt="rviz window" width="600"/>
</p>

#### 2.2.4 Result Checking
As a sanity check for the calculation, the tag position derived from your **end-effector to Tag** transform and from **end-effector-camera-tag** transform chains should be exactly the same.

## 3. Camera-laser extrinsics
![Flowchart](images/Laser_Cali.png)
<p align="center">
<img src="images/Laser_Cali.png" alt="Flowchart" width="600"/>
</p>
### 3.1 Hardware needed
* UR5e robot arm
* Camera holder([Example](https://drive.google.com/file/d/12sZWZGFeq9ehgpnKUAZS80BMfkZedMsY/view?usp=sharing))
Expand Down Expand Up @@ -256,7 +262,7 @@ give example config and dir), which will be used in the calibration later.
To test these parameters, run `laser_stripe_detector` node with sample images
and the config file. (**todo turn on lsd visualization**).
In order to collect more image for laser calibration, please go to **cali_ws** and run the following code:
In order to collect more image for laser calibration, please go to **Calibration_ws** and run the following code:
Open four terminal:
For the First one, connect the arm:
Expand All @@ -283,10 +289,18 @@ Next enable the auto_calibration in the laser_cam mode:
```shell
cd ~/Calibration_ws
source devel/setup.bash
roslaunch multi_calibration auto_calibration.launch directory:="[file position]" laser_cam:=1
roslaunch multi_calibration auto_calibration.launch laser_cam:=1
```
The motion of the robot arm will be like:
<p align="center">
<img src="gifs/laser_motion.gif" alt="Image Viewer Panel" width="500"/>
</p>
After collecting the image relaunch the ```auto_calibration.launch``` with laser_cam:=2. The filter program will automatically start detecting if there is any noise image. Then it will run the laser calibration program and output the result.
**Important:** please paste the result of the intrinsics calibration into [laser_calib.yaml](https://github.com/Flowerst-0416/UR_arm_camera_calibration/blob/main/multi_calibration/cfg/laser_calib.yaml)
```shell
cd ~/Calibration_ws/laser_calib
rosrun multi_calibration laser_calib -i ./ -c ./laser_calib.yaml
```
cd ~/Calibration_ws
source devel/setup.bash
roslaunch multi_calibration auto_calibration.launch laser_cam:=2
```
Binary file modified images/Laser_Cali.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added images/handeye_evl.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added images/handeye_result_shown.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added images/test1.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.

0 comments on commit f6d9e17

Please sign in to comment.