Lithium Ion Cell Testing

Collecting data using a powerlab8 V2 charger. Capable of 40A discharge to a battery supply, 10A internal dissipation.

Cells tested -> Molicell INR-21700-P42A: https://www.imrbatteries.com/content/molicel_p42a.pdf

Can get the Revolectrix CCS PowerLab 8 software here: https://www.rcgroups.com/forums/showthread.php?3963135-Revolectrix-CCS-Install-Workaround#post47730189

Aims

  • check cell capacity variance
  • check cell internal resistance variance
  • understand optimal cell cutoff voltage for our current draw
  • measure cell response to a 60a 10 second current draw

Repo contents

  • data/set1 raw cell data - test setup introduced apparent cell to cell variance - systematic errors in internal resistances ?
  • data/set2 raw cell data - test setup improved (awaiting results)
  • script to process raw data into useful things
  • set 1 summary excel sheet
  • set 2 summary excel sheet
  • set1 plots
  • set2 plots

data

test data in native PowerLab 8 V2 software format (.CP8) as well as tab separated format (.txt)

  • N_cell_cycle.* : (charge to 100% SoC if needed) discharge at 1C to 2.5V, 1 min rest, then charge at 1C to 100% SoC
  • N_cell_storage.* : Discharge from 100% SoC to 3.7V storage charge at 10A, ~2.4C
  • N_cell_stress_XA.* : Discharge from 100% SoC to 4.0V (TBC) at X Amps, ~14C

hi