Frankenso VR Input
For example, 1995 Honda Accord (and most OBD-I Honda vehicle), 2003 Dodge Neon.
Use Trigger #1 N & Trigger #2 N wires with 0R pull-down configuration for sensor(s) negative side
Use Trigger #1 P & Trigger #2 P wires for sensor(s) positive side
Test 2.1: Expected ground on Trigger #1 N wire
Test 2.2: Expected ground on Trigger #2 N wire
Test 2.3: take an AA or AAA battery, connect Battery+ to Trigger #1 N wire, touch battery- with Trigger #1 P wire a couple of times. Then flip the battery and hold Battery+ to Trigger #1 P and touch Battery- with Trigger #1 N wire. Should see event counter in ''triggerinfo'' go up
Test 2.4: take an AA or AAA battery, connect Battery+ to Trigger #2 N wire, touch battery- with Trigger #2 P wire a couple of times. Then flip the battery and hold Battery+ to Trigger #2 P and touch Battery- with Trigger #2 N wire. Should see event counter in ''triggerinfo'' go up