OpenWebNet (BTicino/Legrand) Binding

This new binding integrates BTicino / Legrand MyHOME(r) BUS & ZigBee Radio devices using the OpenWebNet protocol. It is the first known binding for openHAB 2 that supports both wired BUS/SCS as well as wireless ZigBee setups, all in the same biding. The two networks can be configured simultaneously. It's also the first OpenWebNet binding with initial support for discovery of BUS/SCS devices. Commands from openHAB and feedback (events) from BUS/SCS and ZigBee networks are supported.

Support for both numeric (12345) and alpha-numeric (abcde - HMAC authentication) passwords is included.

Prerequisites

In order for this biding to work, an OpenWebNet gateway is needed in your home system to talk to devices. Currently these gateways are supported by the binding:

Supported Things

The following Things and OpenWebNet WHOs are supported:

BUS/SCS

Category WHO Thing Type IDs Discovery? Feedback from BUS? Description Status
Gateway 13 bus_gateway work in progress n/a Any IP gateway supporting OpenWebNet protocol should work (e.g. F454/MyHOMEServer1/MH200N/MH202) Successfully tested: F454, MyHOMEServer1, MH202
Lightning 1 bus_on_off_switch, bus_dimmer Yes Yes BUS switches and dimmers Successfully tested: F411/2, F411/4, F411U2
Automation 2 bus_automation Yes Yes BUS shutters, with position feedback and auto-calibration via a UP >> DOWN >> Position% cycle Successfully tested: LN4672M2
Temperature Control 4 work in progress - - - -

ZigBee (Radio)

Category WHO Thing Type IDs Discovery? Feedback from Radio? Description Status
Gateway 13 dongle Yes n/a ZigBee USB Dongle (BTicino/Legrand models: BTI-3578/088328) Tested: BTI-3578
Lightning 1 dimmer, on_off_switch, on_off_switch2u Yes Yes ZigBee dimmers, switches and 2-unit switches Tested: BTI-4591, BTI-3584, BTI-4585
Automation 2 automation Yes Yes ZigBee shutters, with position feedback and auto-calibration via a UP >> DOWN >> Position% cycle To be tested
Temperature Control 4 work in progress - - - -

Discovery

Discovery is supported using PaperUI by activating the discovery ("+") button form Inbox.

BUS/SCS Discovery

  • Gateway discovery using UPnP is under development and will be available only for IP gateways supporting UPnP.
  • For the moment the OpenWebNet IP gateway should be added manually (see BUS/SCS Gateway configuration below), configuring the password if needed.
  • Once the gateway is added manually as a Thing, a second discovery request from Inbox will discover its devices.
  • BUS/SCS Dimmers must be ON and dimmed (20-100%) at time of discovery, otherwise they will be discovered as simple On/Off switches.

ZigBee Discovery

  • The USB dongle must be inserted in one of the USB ports of the openHAB computer before discovery is started
  • IMPORTANT NOTE: As for the OH serial binding, on Linux the openhab user must be member of the dialout group, to be able to use USB/serial port:
    $ sudo usermod -a -G dialout openhab
    
    • The user will need to logout and login to see the new group added. If you added your user to this group and still cannot get permission, reboot Linux to ensure the new group permission is attached to the openhab user.
  • Once the gateway is discovered and added, a second discovery request from Inbox will discover devices. Because of the ZigBee radio network, discovery will take ~40-60 sec. Be patient!
  • Radio devices must be part of the same ZigBee network of the USB dongle to discover them. Please refer to this guide by BTicino to setup a ZigBee network which includes the USB dongle
  • Only powered radio devices part of the same ZigBee network and within radio coverage of the USB dongle will be discovered. Unreachable or not powered devices will be discovered as GENERIC devices and cannot be controlled. Control units cannot be discovered by the USB dongle and therefore are not supported

Thing Configuration

BUS/SCS Gateway

To configure the gateway: go to Inbox > "+" > OpenWebNet > click ADD MANUALLY and then select OpenWebNet BUS Gateway device, with this configuration:

  • host : IP address / hostname of the BUS/SCS gateway (mandatory). Example: 192.168.1.35
  • port : port (optional, default: 20000)
  • passwd : gateway password (optional). Example: abcde
    • if the BUS/SCS gateway is configured to accept connections from the openHAB computer IP address, no password should be required

Example

Bridge openwebnet:bus_gateway:myBridge1 [ host="192.168.1.35", passwd="abcde" ]

HELP NEEDED!!! Start a gateway discovery, and then send your (DEBUG-level) log file to the openHAB Community OpenWebNet thread to see if UPnP discovery is supported by your BTicino IP gateway.

ZigBee USB Dongle

The ZigBee USB dongle is discovered automatically and added in Inbox. Manual configuration is not supported at the moment.

Devices

For all OpenWebNet devices it must be configured:

  • the associated gateway (Bridge Selection menu)
  • the where config parameter (OpenWebNet Device Address):
    • example for BUS/SCS: Point to Point A=2 PL=4 --> where="24"
    • example for BUS/SCS: Point to Point A=6 PL=4 on local bus --> where="64#4#01"
    • example for ZigBee/Radio: use decimal format address without the UNIT part and network: ZigBee WHERE=414122201#9 --> where="4141222"

Channels

Devices support some of the following channels:

Channel Type ID Item Type Description
switch Switch This channel supports switching the device ON and OFF
brightness Dimmer This channel supports adjusting the brightness value (Percent)
shutter Rollershutter This channel supports activation of roller shutters (UP, DOWN, STOP, Percent). For Percent and position feedback to work the shutterRun parameter must be configured equal to the time (in ms) to go from full UP to full DOWN. Use shutterRun=AUTO (default) to calibrate the shutter automatically the first time a Percent command is sent to the shutter: a UP >> DOWN >> Position% cycle will be performed automatically to calibrate the shutter.

Full Example

demo.things:

Bridge openwebnet:bus_gateway:mybridge1 [ host="192.168.1.35", passwd="abcde" ] {
      bus_on_off_switch   myswitch   [ where="64#4#01" ]
      bus_dimmer          mydimmer   [ where="24" ]
      bus_automation      myshutter  [ where="53", shutterRun="12000"]
}
<TODO----- ZigBee Dongle>
Bridge openwebnet:dongle:mydongle2  [serialPort="kkkkkkk"] {
      dimmer          myzigbeedimmer [ where="xxxxx"]
      on_off_switch   myzigbeeswitch [ where="yyyyy"]
}

demo.items:

Switch BUS_Light           { channel="openwebnet:bus_on_off_switch:mybridge1:myswitch:switch" }
Dimmer BUS_Dimmer          { channel="openwebnet:bus_dimmer:mybridge1:mydimmer:brightness" }
Rollershutter BUS_Shutter  { channel="openwebnet:bus_automation:mybridge1:myshutter:shutter" }

demo.sitemap

<example not available yet>

Disclaimer

  • This binding is not associated by any means with BTicino or Legrand companies

  • The OpenWebNet protocol is maintained and Copyright by BTicino/Legrand. The documentation of the protocol if freely accessible for developers on the MyOpen Community website - https://www.myopen-legrandgroup.com/developers

  • OpenWebNet and MyHOME are registered trademarks by BTicino/Legrand

  • This binding uses openwebnet-lib 0.9.x, an OpenWebNet Java lib partly based on openwebnet/rx-openwebnet client library by @niqdev, to support:

    • gateways and OWN frames for ZigBee
    • frame parsing
    • monitoring events from BUS

    The lib also uses few classes from the openHAB 1.x BTicino binding for socket handling and priority queues.

Packages

No packages published

Languages

  • Java 98.6%
  • HTML 1.4%