Bug fix making both focusers visible #1941

Merged
merged 1 commit into from
Sep 27, 2023

Conversation

sterne-jaeger
Copy link
Contributor

Due to the underlying device name setting in combination with the fact that FocusLynx has two independent drivers, its name setting does not work. As a result, at least when FocusLynx is initialized through KStars locally, only the first focuser is visible. This could only be avoided if the INDI server is started manually.

With this fix the device names of the two focusers are fix to FocusLynx F1/F2, FocusLynx works with both focusers also in KStars local mode.

Due to the underlying device name setting, the fact that FocusLynx
has two independent drivers, its name setting does not work. With
this fix the device names of the two focusers are fix to FocusLynx F1/F2.
@knro knro merged commit d1db0a6 into indilib:master Sep 27, 2023