Skip to content

Commit

Permalink
add support for v3.53~2 and v3.60~13
Browse files Browse the repository at this point in the history
  • Loading branch information
kwindrem committed Dec 28, 2024
1 parent 0055b19 commit 9d94def
Show file tree
Hide file tree
Showing 247 changed files with 24,401 additions and 12,558 deletions.
126 changes: 41 additions & 85 deletions FileSets/PatchSource/dbus_systemcalc.py-v3.40
Original file line number Diff line number Diff line change
Expand Up @@ -278,38 +278,23 @@ class SystemCalc:
self._dbusmonitor = self._create_dbus_monitor(dbus_tree, valueChangedCallback=self._dbus_value_changed,
deviceAddedCallback=self._device_added, deviceRemovedCallback=self._device_removed)

# Used to store AC output maximum values for the scenarios:
# No AC input connected
# Ac input 1 connected
# Ac input 2 connected
self._acMaxima = {
'NoAcIn': 0,
'AcIn1': 0,
'AcIn2': 0
}

self._minMaxPaths = {
'/Ac/In/0/Current/Min': [float(0), -float("inf"), 0],
'/Ac/In/1/Current/Min': [float(0), -float("inf"), 0],
'/Ac/In/0/Current/Max': [float(0), 0, float("inf")],
'/Ac/In/1/Current/Max': [float(0), 0, float("inf")],
'/Dc/Input/Power/Max': [float(0), 0, float("inf")],
'/Dc/System/Power/Max': [float(0), 0, float("inf")],
'/Pv/Power/Max': [float(0), 0, float("inf")]
}

for p in self._acMaxima.keys():
self._minMaxPaths['/Ac/%s/Consumption/Current/Max' % p] = [float(0), 0, float("inf")]

# Connect to localsettings
supported_settings = {
'batteryservice': ['/Settings/SystemSetup/BatteryService', self.BATSERVICE_DEFAULT, 0, 0],
'hasdcsystem': ['/Settings/SystemSetup/HasDcSystem', 0, 0, 1],
'useacout': ['/Settings/SystemSetup/HasAcOutSystem', 1, 0, 1],
'gaugeautomax': ['/Settings/Gui/Gauges/AutoMax', 1, 0, 1]}

for p, s in self._minMaxPaths.items():
supported_settings[p] = ['/Settings/Gui/Gauges' + p, s[0], s[1], s[2]]
'gaugeautomax': ['/Settings/Gui/Gauges/AutoMax', 1, 0, 1],
'acin0min': ['/Settings/Gui/Gauges/Ac/In/0/Current/Min', float(0), -float("inf"), 0],
'acin1min': ['/Settings/Gui/Gauges/Ac/In/1/Current/Min', float(0), -float("inf"), 0],
'acin0max': ['/Settings/Gui/Gauges/Ac/In/0/Current/Max', float(0), 0, float("inf")],
'acin1max': ['/Settings/Gui/Gauges/Ac/In/1/Current/Max', float(0), 0, float("inf")],
'dcinmax': ['/Settings/Gui/Gauges/Dc/Input/Power/Max', float(0), 0, float("inf")],
'dcsysmax': ['/Settings/Gui/Gauges/Dc/System/Power/Max', float(0), 0, float("inf")],
'pvmax': ['/Settings/Gui/Gauges/Pv/Power/Max', float(0), 0, float("inf")],
'noacinmax': ['/Settings/Gui/Gauges/Ac/NoAcIn/Consumption/Current/Max', float(0), 0, float("inf")],
'acin1max': ['/Settings/Gui/Gauges/Ac/AcIn1/Consumption/Current/Max', float(0), 0, float("inf")],
'acin2max': ['/Settings/Gui/Gauges/Ac/AcIn2/Consumption/Current/Max', float(0), 0, float("inf")],
}

for m in self._modules:
for setting in m.get_settings():
Expand Down Expand Up @@ -394,8 +379,6 @@ class SystemCalc:
'/Dc/Charger/Power': {'gettext': '%.0F %%'},
'/Dc/FuelCell/Power': {'gettext': '%.0F %%'},
'/Dc/Alternator/Power': {'gettext': '%.0F W'},
'/Dc/Vebus/Current': {'gettext': '%.1F A'},
'/Dc/Vebus/Power': {'gettext': '%.0F W'},
'/Dc/System/Power': {'gettext': '%.0F W'},
'/Dc/System/Current': {'gettext': '%.1F A'},
'/Dc/System/MeasurementType': {'gettext': '%d'},
Expand All @@ -407,14 +390,6 @@ class SystemCalc:
'/Ac/ActiveIn/L2/Current': {'gettext': '%.1F A'},
'/Ac/ActiveIn/L3/Current': {'gettext': '%.1F A'},
'/Ac/ActiveIn/NumberOfPhases': {'gettext': '%d'},
'/Ac/In/0/Current/Min': {'gettext': '%.1F'},
'/Ac/In/0/Current/Max': {'gettext': '%.1F'},
'/Ac/In/1/Current/Min': {'gettext': '%.1F'},
'/Ac/In/1/Current/Max': {'gettext': '%.1F'},
'/Ac/Consumption/Current/Max': {'gettext': '%.1F'},
'/Pv/Power/Max': {'gettext': '%d'},
'/Dc/Input/Power/Max': {'gettext': '%d'},
'/Dc/System/Power/Max': {'gettext': '%d'},
#### added for GuiMods
'/Dc/WindGenerator/Power': {'gettext': '%.0F W'},
'/Dc/MotorDrive/Power': {'gettext': '%.0F W'},
Expand Down Expand Up @@ -1221,66 +1196,64 @@ class SystemCalc:
m.update_values(newvalues)

# ==== UPDATE MINIMUM AND MAXIMUM LEVELS ====
# min/max values are stored in localsettings and synched once in a while.
# values are stored under /Settings/Gui/Briefview
# /Settings/Gui/Gauges/AutoMax:
# 1-> Automatic: Maxima are updated automatically and synched to localsettings
# 0-> Manual: Maxima are pulled from localsettings.
# min/max computations are done here because the _updatevalues method abstracts them
# away from the delegates.

# AC output
# This maximum is maintained for 3 situations:
# 1: AC input 1 is connected
# 2: AC input 2 is connected
# 3: No AC input is connected
# All 3 scenarios may lead to different maximum values since the capabilities of the system changes.
# So 3 different maxima are stored and relayed to /Ac/Consumption/Current/Max based on the active scenario.
activeIn = 'AcIn1' if (self._dbusservice['/Ac/In/0/Connected'] == 1) else \
'AcIn2' if (self._dbusservice['/Ac/In/1/Connected'] == 1) else \
'NoAcIn'

# Quattro has 2 AC inputs which cannot be active simultaneously.
# activeIn needs to 1 when 'Ac/In/1/Connected' is 1 and can be 0 otherwise.
if (self._settings['gaugeautomax']):
activeInNr = int(activeIn[-1]) -1 if activeIn != 'NoAcIn' else None
# min/max values are stored and updated in localsettings
# values are stored under /Settings/Gui/Briefview
# /Settings/Gui/Gauges/AutoMax:
# 1-> Automatic: Gauge limits are updated automatically and stored in localsettings
# 0-> Manual: Gauge limits are entered manually by the user
# The gui pulls the gauge limits from localsettings and provides
# a means for the user to set them if Automax is off.

# AC output
# This maximum is maintained for 3 situations:
# 1: AC input 1 is connected
# 2: AC input 2 is connected
# 3: No AC input is connected
# All 3 scenarios may lead to different maximum values since the capabilities of the system changes.
# So 3 different maxima are stored and relayed to /Ac/Consumption/Current/Max based on the active scenario.
activeIn = 'acin1' if (self._dbusservice['/Ac/In/0/Connected'] == 1) else \
'acin2' if (self._dbusservice['/Ac/In/1/Connected'] == 1) else \
'noacin'

# Quattro has 2 AC inputs which cannot be active simultaneously.
# activeIn needs to 1 when 'Ac/In/1/Connected' is 1 and can be 0 otherwise.
activeInNr = int(activeIn[-1]) -1 if activeIn != 'noacin' else None

# AC input
# Minimum values occur when feeding back to the grid.
# For the minimum value, make sure it is 0 at its maximum.
# Update correct '/Ac/In/..' based on the current active input.
# When no inputs are active, paths '/Ac/In/[0/1]/Current/[Min/Max] will all be invalidated.
if(activeInNr != None):
newvalues['/Ac/In/%s/Current/Min' % activeInNr] = min(0,
self._dbusservice['/Ac/In/%s/Current/Min' % activeInNr] or float("inf"),
self._settings['acin%smin' % activeInNr] = min(0,
self._settings['acin%smin' % activeInNr] or float("inf"),
newvalues.get('/Ac/ActiveIn/L1/Current') or float("inf"),
newvalues.get('/Ac/ActiveIn/L2/Current') or float("inf"),
newvalues.get('/Ac/ActiveIn/L3/Current') or float("inf"))

newvalues['/Ac/In/%s/Current/Max' % activeInNr] = max(self._dbusservice['/Ac/In/%s/Current/Min' % activeInNr] or 0,
self._settings['acin%smax' % activeInNr] = max(self._settings['acin%smax' % activeInNr] or 0,
newvalues.get('/Ac/ActiveIn/L1/Current') or 0,
newvalues.get('/Ac/ActiveIn/L2/Current') or 0,
newvalues.get('/Ac/ActiveIn/L3/Current') or 0)

self._acMaxima[activeIn] = max(self._acMaxima[activeIn],
self._settings['%smax' % activeIn] = max(self._settings['%smax' % activeIn],
newvalues.get('/Ac/Consumption/L1/Current') or 0,
newvalues.get('/Ac/Consumption/L2/Current') or 0,
newvalues.get('/Ac/Consumption/L3/Current') or 0)

newvalues['/Ac/Consumption/Current/Max'] = self._acMaxima[activeIn]

# DC input
newvalues['/Dc/Input/Power/Max'] = max(self._dbusservice['/Dc/Input/Power/Max'] or 0,
self._settings['dcinmax'] = max(self._settings['dcinmax'] or 0,
sum([newvalues.get('/Dc/Charger/Power') or 0,
newvalues.get('/Dc/FuelCell/Power') or 0,
newvalues.get('/Dc/Alternator/Power') or 0]))

# DC output
newvalues['/Dc/System/Power/Max'] = _safemax(self._dbusservice['/Dc/System/Power/Max'] or 0,
self._settings['dcsysmax'] = _safemax(self._settings['dcsysmax'] or 0,
newvalues.get('/Dc/System/Power') or 0)

# PV power
newvalues['/Pv/Power/Max'] = _safemax(self._dbusservice['/Pv/Power/Max'] or 0,
self._settings['pvmax'] = _safemax(self._settings['pvmax'] or 0,
_safeadd(newvalues.get('/Dc/Pv/Power') or 0,
self._dbusservice['/Ac/PvOnGrid/L1/Power'],
self._dbusservice['/Ac/PvOnGrid/L2/Power'],
Expand All @@ -1292,23 +1265,6 @@ class SystemCalc:
self._dbusservice['/Ac/PvOnOutput/L2/Power'],
self._dbusservice['/Ac/PvOnOutput/L3/Power']))

# Sync max values to localsettings (once each second)
for p in self._minMaxPaths.keys():
if (p in newvalues and newvalues[p] != self._settings[p]):
self._settings[p] = newvalues[p]

# Store the ac maxima values for the 3 different scenarios. These aren't in newvalues.
if(self._acMaxima[activeIn] != self._settings['/Ac/%s/Consumption/Current/Max' % activeIn]):
self._settings['/Ac/%s/Consumption/Current/Max' % activeIn] = self._acMaxima[activeIn]

# Manual mode: relay min/max settings from localsettings to newvalues
# We have to fill newvalues on every iteration here because if we don't the value in dbusservice is invalidated
else:
for p in self._minMaxPaths.keys():
newvalues[p] = self._settings[p]

newvalues['/Ac/Consumption/Current/Max'] = self._settings['/Ac/%s/Consumption/Current/Max' % activeIn]

# ==== UPDATE DBUS ITEMS ====
with self._dbusservice as sss:
for path in self._summeditems.keys():
Expand Down