deploy: fba2602
Browse files Browse the repository at this point in the history
  • Loading branch information
gtfierro committed Mar 19, 2024
1 parent 3d9f659 commit 2cc3d37
Show file tree
Hide file tree
Showing 16 changed files with 161,159 additions and 161,159 deletions.
6,298 changes: 3,149 additions & 3,149 deletions bdg1-1.jsonld

Large diffs are not rendered by default.

4,316 changes: 2,158 additions & 2,158 deletions bdg1-2.jsonld

Large diffs are not rendered by default.

488 changes: 244 additions & 244 deletions compiled/guideline36-2021-A-4.ttl

Large diffs are not rendered by default.

312 changes: 156 additions & 156 deletions compiled/guideline36-2021-A-8.ttl

Large diffs are not rendered by default.

7,772 changes: 3,886 additions & 3,886 deletions compiled/nist-example.ttl

Large diffs are not rendered by default.

198 changes: 99 additions & 99 deletions guideline36-2021-A-1.jsonld
Original file line number Diff line number Diff line change
@@ -1,30 +1,31 @@
[
{
"@id": "urn:ex/discharge-air-flow",
"@id": "urn:ex/damper",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
],
"http://data.ashrae.org/standard223#hasAspect": [
"http://data.ashrae.org/standard223#cnx": [
{
"@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
"@id": "urn:ex/damper-in"
},
{
"@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
"@id": "urn:ex/damper-out"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
"http://data.ashrae.org/standard223#hasProperty": [
{
"@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
"@id": "urn:ex/damper-command"
},
{
"@id": "urn:ex/damper-position"
}
]
},
{
"@id": "urn:ex/duct-after-damper",
"@id": "urn:ex/out-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
Expand All @@ -33,10 +34,9 @@
]
},
{
"@id": "urn:ex/duct-before-damper",
"@id": "urn:ex/in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
Expand All @@ -45,50 +45,24 @@
]
},
{
"@id": "urn:ex/in",
"@id": "urn:ex/",
"@type": [
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
"@id": "urn:ex/in-connection"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
"http://www.w3.org/2002/07/owl#Ontology"
]
},
{
"@id": "urn:ex/damper-command",
"@id": "urn:ex/discharge-air-flow-sensor",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://data.ashrae.org/standard223#hasAspect": [
{
"@id": "http://data.ashrae.org/standard223#EnumerationKind-Position"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
"http://data.ashrae.org/standard223#Sensor"
],
"http://qudt.org/schema/qudt/hasUnit": [
"http://data.ashrae.org/standard223#hasObservationLocation": [
{
"@id": "http://qudt.org/vocab/unit/PERCENT"
"@id": "urn:ex/out"
}
]
},
{
"@id": "urn:ex/in-connection",
"@type": [
"http://data.ashrae.org/standard223#Connection"
],
"http://data.ashrae.org/standard223#hasMedium": [
"http://data.ashrae.org/standard223#observes": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
"@id": "urn:ex/discharge-air-flow"
}
]
},
Expand All @@ -114,53 +88,74 @@
]
},
{
"@id": "urn:ex/damper",
"@id": "urn:ex/damper-actuator",
"@type": [
"http://data.ashrae.org/standard223#Damper",
"http://data.ashrae.org/standard223/1.0/extensions/g36#Damper"
"http://data.ashrae.org/standard223#Actuator"
],
"http://data.ashrae.org/standard223#cnx": [
{
"@id": "urn:ex/damper-in"
},
"http://data.ashrae.org/standard223#actuates": [
{
"@id": "urn:ex/damper-out"
"@id": "urn:ex/damper"
}
],
"http://data.ashrae.org/standard223#hasProperty": [
"http://data.ashrae.org/standard223#commandedByProperty": [
{
"@id": "urn:ex/damper-command"
},
}
]
},
{
"@id": "urn:ex/duct-after-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "urn:ex/damper-position"
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
"@id": "urn:ex/damper-out",
"@id": "urn:ex/damper-position",
"@type": [
"http://data.ashrae.org/standard223#OutletConnectionPoint"
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#cnx": [
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "urn:ex/duct-after-damper"
"@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
"http://qudt.org/schema/qudt/hasUnit": [
{
"@id": "http://data.ashrae.org/standard223#Medium-Air"
"@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
},
{
"@id": "urn:ex/vav-cooling-only",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAV"
],
"http://data.ashrae.org/standard223#mapsTo": [
"http://data.ashrae.org/standard223#cnx": [
{
"@id": "urn:ex/in"
},
{
"@id": "urn:ex/out"
}
],
"http://data.ashrae.org/standard223#contains": [
{
"@id": "urn:ex/damper"
}
]
},
{
"@id": "urn:ex/out-connection",
"@id": "urn:ex/duct-before-damper",
"@type": [
"http://data.ashrae.org/standard223#Connection"
"http://data.ashrae.org/standard223#Connection",
"http://data.ashrae.org/standard223#Duct"
],
"http://data.ashrae.org/standard223#hasMedium": [
{
Expand All @@ -169,27 +164,26 @@
]
},
{
"@id": "urn:ex/damper-position",
"@id": "urn:ex/discharge-air-flow",
"@type": [
"http://data.ashrae.org/standard223#QuantifiableObservableProperty"
],
"http://data.ashrae.org/standard223#hasAspect": [
{
"@id": "http://data.ashrae.org/standard223#Role-Discharge"
}
],
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
"@id": "http://qudt.org/vocab/quantitykind/VolumeFlowRate"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
"@id": "http://qudt.org/vocab/unit/PERCENT"
"@id": "http://qudt.org/vocab/unit/FT3-PER-MIN"
}
]
},
{
"@id": "urn:ex/",
"@type": [
"http://www.w3.org/2002/07/owl#Ontology"
]
},
{
"@id": "urn:ex/damper-in",
"@type": [
Expand All @@ -212,54 +206,60 @@
]
},
{
"@id": "urn:ex/vav-cooling-only",
"@id": "urn:ex/damper-out",
"@type": [
"http://data.ashrae.org/standard223#SingleDuctTerminal",
"http://data.ashrae.org/standard223/1.0/extensions/g36#VAV"
"http://data.ashrae.org/standard223#OutletConnectionPoint"
],
"http://data.ashrae.org/standard223#cnx": [
{
"@id": "urn:ex/in"
},
"@id": "urn:ex/duct-after-damper"
}
],
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "urn:ex/out"
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
],
"http://data.ashrae.org/standard223#contains": [
"http://data.ashrae.org/standard223#mapsTo": [
{
"@id": "urn:ex/damper"
"@id": "urn:ex/out"
}
]
},
{
"@id": "urn:ex/discharge-air-flow-sensor",
"@id": "urn:ex/in",
"@type": [
"http://data.ashrae.org/standard223#Sensor"
"http://data.ashrae.org/standard223#InletConnectionPoint"
],
"http://data.ashrae.org/standard223#hasObservationLocation": [
"http://data.ashrae.org/standard223#cnx": [
{
"@id": "urn:ex/out"
"@id": "urn:ex/in-connection"
}
],
"http://data.ashrae.org/standard223#observes": [
"http://data.ashrae.org/standard223#hasMedium": [
{
"@id": "urn:ex/discharge-air-flow"
"@id": "http://data.ashrae.org/standard223#Medium-Air"
}
]
},
{
"@id": "urn:ex/damper-actuator",
"@id": "urn:ex/damper-command",
"@type": [
"http://data.ashrae.org/standard223#Actuator"
"http://data.ashrae.org/standard223#QuantifiableActuatableProperty"
],
"http://data.ashrae.org/standard223#actuates": [
"http://data.ashrae.org/standard223#hasAspect": [
{
"@id": "urn:ex/damper"
"@id": "http://data.ashrae.org/standard223#EnumerationKind-Position"
}
],
"http://data.ashrae.org/standard223#commandedByProperty": [
"http://qudt.org/schema/qudt/hasQuantityKind": [
{
"@id": "urn:ex/damper-command"
"@id": "http://qudt.org/vocab/quantitykind/DimensionlessRatio"
}
],
"http://qudt.org/schema/qudt/hasUnit": [
{
"@id": "http://qudt.org/vocab/unit/PERCENT"
}
]
}
Expand Down