Skip to content

Commit

Permalink
Merge pull request #1072 from LKuemmel/changes_snaptec_repo
Browse files Browse the repository at this point in the history
Changes snaptec repo
  • Loading branch information
LKuemmel authored Aug 3, 2023
2 parents 5eb44db + 27177ea commit 066b715
Show file tree
Hide file tree
Showing 9 changed files with 98 additions and 137 deletions.
19 changes: 5 additions & 14 deletions packages/modules/devices/rct/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -27,23 +27,14 @@ def update(self, rct_client: RCT) -> None:
# read all parameters
rct_client.read(my_tab)

# postprocess values
soc = socx.value
power = int(watt1.value) * -1.0
imported = int(watt2.value)
exported = int(watt3.value)
stat1 = int(stat1.value)
stat2 = int(stat2.value)
stat3 = int(stat3.value)

if (stat1 + stat2 + stat3) > 0:
if (stat1.value + stat2.value + stat3.value) > 0:
raise FaultState.error("Alarm Status Speicher ist ungleich 0.")

bat_state = BatState(
power=int(power) * -1,
soc=soc * 100,
imported=int(imported),
exported=int(exported)
power=watt1.value * -1,
soc=socx.value * 100,
imported=watt2.value,
exported=watt3.value
)
self.store.set(bat_state)

Expand Down
12 changes: 6 additions & 6 deletions packages/modules/devices/rct/counter.py
Original file line number Diff line number Diff line change
Expand Up @@ -35,16 +35,16 @@ def update(self, rct_client: RCT):
# read all parameters
rct_client.read(my_tab)

if (stat1 + stat2 + stat3 + stat4) > 0:
if (stat1.value + stat2.value + stat3.value + stat4.value) > 0:
raise FaultState.error("Alarm Status Zähler ist ungleich 0.")

counter_state = CounterState(
imported=int(imported.value),
imported=imported.value,
exported=exported.value*-1.0,
power=int(power.value),
frequency=int(freq.value),
powers=[int(power1.value), int(power2.value), int(power3.value)],
voltages=[int(volt1.value), int(volt2.value), int(volt3.value)]
power=power.value,
frequency=freq.value,
powers=[power1.value, power2.value, power3.value],
voltages=[volt1.value, volt2.value, volt3.value]
)
self.store.set(counter_state)

Expand Down
70 changes: 24 additions & 46 deletions packages/modules/devices/rct/rct_lib.py
Original file line number Diff line number Diff line change
Expand Up @@ -22,9 +22,8 @@

log = logging.getLogger(__name__)

# helper function to print and error


# helper function to print and error
def hexdump(src, length=16):
FILTER = ''.join([(len(repr(chr(x))) == 3) and chr(x) or '.' for x in range(256)])
lines = []
Expand Down Expand Up @@ -75,7 +74,7 @@ def __init__(self, msgid, idx, name, data_type=rct_data.t_unknown, desc=''):
self.name = name
self.desc = desc
self.value = None
self.pending = False # used to read pending
self.pending = False # used to read pending

# decode a value according to the id data type
def decode_value(self, data):
Expand Down Expand Up @@ -130,21 +129,21 @@ def decode_value(self, data):
cmd_long_response = 0x06
cmd_extension = 0x3C

HEADER_WITH_LENGTH = 1 + 1 + 2 # frame length for header, command and 2 byte length
FRAME_TYPE_STANDARD = 4 # standard frame with id
FRAME_TYPE_PLANT = 8 # plant frame with id and address
FRAME_CRC16_LENGTH = 2 # nr of bytes for CRC16 field
HEADER_WITH_LENGTH = 1 + 1 + 2 # frame length for header, command and 2 byte length
FRAME_TYPE_STANDARD = 4 # standard frame with id
FRAME_TYPE_PLANT = 8 # plant frame with id and address
FRAME_CRC16_LENGTH = 2 # nr of bytes for CRC16 field


class Frame:
def __init__(self, command=0, address=0, frame_type=FRAME_TYPE_STANDARD):
self.command = command
self.address = address # for plant communication only
self.address = address # for plant communication only
self.idList = []
self.frame_type = frame_type
self.bEscapeMode = False
self.rxStream = b""
self.pendingCount = False # nr of id's which are not yet handled
self.pendingCount = False # nr of id's which are not yet handled
self.statisticRxDropped = 0
self.statisticRxConsumed = 0
self.statisticRxDuplicate = 0
Expand All @@ -167,7 +166,7 @@ def add(self, item):
self.pendingCount += 1

# consume all data, extract frames and decode them.
# Incomplete frames remain in self.rxStream for the nexht data chunk
# Incomplete frames remain in self.rxStream for the next data chunk
def consume(self, data):
for d in data:
c = bytes([d])
Expand All @@ -182,7 +181,7 @@ def consume(self, data):
self.bEscapeMode = False
else:
if c == escape_token:
self.bEscapeMode = True # escape mode -> set mode and don't add byte
self.bEscapeMode = True # escape mode -> set mode and don't add byte
continue

# add byte to receive stream
Expand All @@ -193,11 +192,11 @@ def consume(self, data):
if len(self.rxStream) == HEADER_WITH_LENGTH:
cmd = struct.unpack("B", bytes([self.rxStream[1]]))[0]
if cmd == cmd_long_response or cmd == cmd_long_write:
self.FrameLength = struct.unpack(">H", self.rxStream[2:4])[0] + 2 # 2 byte length MSBF
self.FrameLength = struct.unpack(">H", self.rxStream[2:4])[0] + 2 # 2 byte length MSBF
else:
self.FrameLength = struct.unpack(">B", bytes([self.rxStream[2]]))[0] + 1 # 1 byte length
self.FrameLength = struct.unpack(">B", bytes([self.rxStream[2]]))[0] + 1 # 1 byte length

self.FrameLength += 2 # 2 bytes header
self.FrameLength += 2 # 2 bytes header
else:
if len(self.rxStream) == self.FrameLength + FRAME_CRC16_LENGTH:
# print(binascii.hexlify(self.rxStream))
Expand All @@ -222,10 +221,10 @@ def decode(self):
data_length = struct.unpack(">H", self.rxStream[2:4])[0] # 2 byte length MSBF
idx = 4
else:
data_length = struct.unpack(">B", bytes([self.rxStream[2]]))[0] # 1 byte length
data_length = struct.unpack(">B", bytes([self.rxStream[2]]))[0] # 1 byte length
idx = 3

# substract frame type specific length
# subtract frame type specific length
data_length -= self.frame_type

# extract 32 bit ID
Expand Down Expand Up @@ -299,18 +298,18 @@ def encode(self):

# just for completeness but PLANT frames are not used in send direction
if self.frame_type == FRAME_TYPE_PLANT:
buf += struct.pack('>I', self.address) # 4 bytes
buf += struct.pack('>I', self.address) # 4 bytes

# append id
buf += struct.pack('>I', item.id) # 4 bytes
buf += struct.pack('>I', item.id) # 4 bytes

# append data if used
if item.value is not None:
buf += self.encode_by_type(item.data_type, item.value)

# calculate and append CRC16
crc16 = self.CRC16(buf)
buf += struct.pack('>H', crc16) # 2 bytes
buf += struct.pack('>H', crc16) # 2 bytes

# add start token and inject escape tokens in buf where necessary to buf_all
buf_all += struct.pack('c', start_token) + self.createStream(buf)
Expand Down Expand Up @@ -445,7 +444,7 @@ def connect_to_server(self):
self.socket.settimeout(2.0)
try:
self.socket.connect((self.host, self.port))
log.debug('connect to ', self.host, 'port', self.port)
log.debug('connect to {} port {}'.format(self.host, self.port))
return True
except Exception:
print("-"*100)
Expand Down Expand Up @@ -530,27 +529,6 @@ def close(self):
print("-"*100)
traceback.print_exc(file=sys.stdout)

# write value to a ramdisk variable
def write_ramdisk(self, fn, val, rctname):
try:
fnn = "/var/www/html/openWB/ramdisk/"+str(fn)
with open(fnn, 'w') as f:
f.write(str(val))
except Exception:
return

# helper function to print debug messages
def errlog(self, *args):
self.logger.error(' '.join(map(str, args)))

# helper function to print debug messages
def dbglog(self, *args):
self.logger.debug(' '.join(map(str, args)))

# helper function to print info messages
def infolog(self, *args):
self.logger.info(' '.join(map(str, args)))

def id_tab_setup(self):
# add all known id's with name, data type, description and unit to the id table
self.id_tab.append(rct_id(0x0104EB6A, 0, "rb485.f_grid[2]",
Expand All @@ -562,7 +540,7 @@ def id_tab_setup(self):
self.id_tab.append(rct_id(0x01676FA6, 3, "battery.cells_stat[3]",
rct_data.t_string, "battery.cells_stat[3]"))
self.id_tab.append(rct_id(0x019C0B60, 4, "cs_neg[2]",
rct_data.t_float, "Miltiply value of the current sensor 2 by"))
rct_data.t_float, "Multiply value of the current sensor 2 by"))
self.id_tab.append(rct_id(0x02247588, 5, "battery_placeholder[0].cells_stat[2].u_min.value",
rct_data.t_float, "battery_placeholder[0].cells_stat[2].u_min.value"))
self.id_tab.append(rct_id(0x031A6110, 6, "energy.e_ext_month",
Expand Down Expand Up @@ -1068,7 +1046,7 @@ def id_tab_setup(self):
self.id_tab.append(rct_id(0x4BE02BB7, 256, "energy.e_load_day_sum",
rct_data.t_float, "energy.e_load_day_sum"))
self.id_tab.append(rct_id(0x4C12C4C7, 257, "cs_neg[1]",
rct_data.t_float, "Miltiply value of the current sensor 1 by"))
rct_data.t_float, "Multiply value of the current sensor 1 by"))
self.id_tab.append(rct_id(0x4C14CC7C, 258, "logger.year_ea_log_ts",
rct_data.t_log_ts, "logger.year_ea_log_ts"))
self.id_tab.append(rct_id(0x4C2A7CDC, 259, "nsm.cos_phi_p[2][1]",
Expand Down Expand Up @@ -1488,7 +1466,7 @@ def id_tab_setup(self):
self.id_tab.append(rct_id(0x81AF854E, 466, "nsm.pu_use",
rct_data.t_bool, "P(U) active"))
self.id_tab.append(rct_id(0x82258C01, 467, "cs_neg[0]",
rct_data.t_float, "Miltiply value of the current sensor 0 by"))
rct_data.t_float, "Multiply value of the current sensor 0 by"))
self.id_tab.append(rct_id(0x82CD1525, 468, "grid_mon[1].u_under.threshold",
rct_data.t_float, "Min. voltage level 2 [V]"))
self.id_tab.append(rct_id(0x82E3C121, 469, "g_sync.q_ac[1]",
Expand Down Expand Up @@ -1815,8 +1793,8 @@ def id_tab_setup(self):
rct_data.t_float, "Grid power phase 3 [W]"))
self.id_tab.append(rct_id(0xB228EC94, 630, "battery_placeholder[0].cells_stat[3].t_max.time",
rct_data.t_uint32, "battery_placeholder[0].cells_stat[3].t_max.time"))
self.id_tab.append(rct_id(0xB238942F, 631, "last_successfull_flash_op",
rct_data.t_int16, "last_successfull_flash_op"))
self.id_tab.append(rct_id(0xB238942F, 631, "last_successful_flash_op",
rct_data.t_int16, "last_successful_flash_op"))
self.id_tab.append(rct_id(0xB298395D, 632, "dc_conv.dc_conv_struct[0].u_sg_lp",
rct_data.t_float, "Solar generator A voltage [V]"))
self.id_tab.append(rct_id(0xB2FB9A90, 633, "bat_mng_struct.k_trust",
Expand Down
24 changes: 6 additions & 18 deletions packages/modules/smarthome/idm/off.py
Original file line number Diff line number Diff line change
@@ -1,36 +1,21 @@
#!/usr/bin/python3
import sys
import os
import struct
from pymodbus.client.sync import ModbusTcpClient
import logging
from smarthome.smartlog import initlog
devicenumber = int(sys.argv[1])
ipadr = str(sys.argv[2])
uberschuss = int(sys.argv[3])
try:
navvers = str(sys.argv[4])
except Exception:
navvers = "2"
navvers = str(sys.argv[4])
bp = '/var/www/html/openWB/ramdisk/smarthome_device_'
# standard
file_stringpv = bp + str(devicenumber) + '_pv'
file_stringcount = bp + str(devicenumber) + '_count'
file_stringcount5 = bp + str(devicenumber) + '_count5'
initlog("idm", devicenumber)
log = logging.getLogger("idm")
log.info(" devicenr %d ipadr %s ueberschuss %6d try to connect (modbus)"
log.info(" off.py devicenr %d ipadr %s ueberschuss %6d "
% (devicenumber, ipadr, uberschuss))
client = ModbusTcpClient(ipadr, port=502)
start = 4122
if navvers == "2":
rr = client.read_input_registers(start, 2, unit=1)
else:
rr = client.read_holding_registers(start, 2, unit=1)
raw = struct.pack('>HH', rr.getRegister(1), rr.getRegister(0))
lkw = float(struct.unpack('>f', raw)[0])
aktpower = int(lkw*1000)
log.info(" devicenr %d ipadr %s Akt Leistung %6d"
% (devicenumber, ipadr, aktpower))
pvmodus = 0
if os.path.isfile(file_stringpv):
with open(file_stringpv, 'r') as f:
Expand All @@ -44,3 +29,6 @@
count1 = 999
with open(file_stringcount, 'w') as f:
f.write(str(count1))
count5 = 999
with open(file_stringcount5, 'w') as f:
f.write(str(count5))
24 changes: 6 additions & 18 deletions packages/modules/smarthome/idm/on.py
Original file line number Diff line number Diff line change
@@ -1,39 +1,27 @@
#!/usr/bin/python3
import sys
import struct
from pymodbus.client.sync import ModbusTcpClient
import logging
from smarthome.smartlog import initlog
devicenumber = int(sys.argv[1])
ipadr = str(sys.argv[2])
uberschuss = int(sys.argv[3])
bp = '/var/www/html/openWB/ramdisk/smarthome_device_'
try:
navvers = str(sys.argv[4])
except Exception:
navvers = "2"
navvers = str(sys.argv[4])
initlog("idm", devicenumber)
log = logging.getLogger("idm")
# standard
# lesen
# own log
file_stringpv = bp + str(devicenumber) + '_pv'
file_stringcount = bp + str(devicenumber) + '_count'
log.info("devicenr %d ipadr %s ueberschuss %6d try to connect (modbus)"
file_stringcount5 = bp + str(devicenumber) + '_count5'
log.info("on.py devicenr %d ipadr %s ueberschuss %6d"
% (devicenumber, ipadr, uberschuss))
client = ModbusTcpClient(ipadr, port=502)
start = 4122
if navvers == "2":
rr = client.read_input_registers(start, 2, unit=1)
else:
rr = client.read_holding_registers(start, 2, unit=1)
raw = struct.pack('>HH', rr.getRegister(1), rr.getRegister(0))
lkw = float(struct.unpack('>f', raw)[0])
aktpower = int(lkw*1000)
log.info("devicenr %d ipadr %s Akt Leistung %6d " %
(devicenumber, ipadr, aktpower))
with open(file_stringpv, 'w') as f:
f.write(str(1))
count1 = 999
with open(file_stringcount, 'w') as f:
f.write(str(count1))
count5 = 999
with open(file_stringcount5, 'w') as f:
f.write(str(count5))
5 changes: 4 additions & 1 deletion packages/modules/smarthome/idm/smartidm.py
Original file line number Diff line number Diff line change
Expand Up @@ -31,15 +31,18 @@ def updatepar(self, input_param: Dict[str, str]) -> None:

def getwatt(self, uberschuss: int, uberschussoffset: int) -> None:
self.prewatt(uberschuss, uberschussoffset)
forcesend = self.checkbefsend()
argumentList = ['python3', self._prefixpy + 'idm/watt.py',
str(self.device_nummer), str(self._device_ip),
str(self.devuberschuss), str(self._device_idmnav)]
str(self.devuberschuss), str(self._device_idmnav),
str(self.pvwatt), str(forcesend)]
try:
self.callpro(argumentList)
self.answer = self.readret()
self.newwatt = int(self.answer['power'])
self.newwattk = int(self.answer['powerc'])
self.relais = int(self.answer['on'])
self.checksend(self.answer)
except Exception as e1:
log.warning("(" + str(self.device_nummer) +
") Leistungsmessung %s %d %s Fehlermeldung: %s "
Expand Down
Loading

0 comments on commit 066b715