Notifications
You must be signed in to change notification settings - Fork 43
Migration guide v4.7.0
During CGMES import, all target flows are now set by SSH profile and all calculated flows are set by SV profile.
In CGMES import, the parameter iidm.import.cgmes.profile-used-for-initial-state-values
has been deprecated and now has the same behaviour as the new parameter iidm.import.cgmes.profile-for-initial-values-shunt-sections-tap-positions
and only defines if shunt sections and tap positions are defined by SSH or SV profiles.
From this release, the CGMES update mechanism is not supported anymore. You are now able to generate CGMES files from any network by using the CGMES exporter. By default, all profiles are exported (EQ, TP, SSH and SV) but you can modify the configuration if you want to export specific profiles.
For example, if you wish to export only the SSH and SV profiles, add this to your configuration:
import-export-parameters-default-value:
iidm.export.cgmes.profiles:
- SSH
- SV
You can also pass a Properties
object containing this configuration:
Properties properties = new Properties();
properties.put("iidm.export.cgmes.profiles", List.of("SSH", "SV"));
new CgmesExport().export(network, properties, dataSource);
Methods in BranchObservability
and InjectionObservability
setting the redundant
attribute of ObservabilityQuality
sub-objects, such as setQualityP1(double standardDeviation, boolean redundant)
, do not pass a Boolean
anymore but a boolean
, preventing null object to be passed.
Transformers created directly in the network (not in a substation) must now have all of their legs directly in the network as well (not in a substation). In parallel, transformers created in a substation must now have all of their legs in this substation. Transformers with part of their legs directly in the network and part of their legs in a substation are now forbidden.
At this release, IIDM has been changed to version 1.7. Consequently, if you are using a XIIDM converter from powsybl-core v4.7.0 and above to write IIDM network files in version 1.7, you should use a XIIDM converter from powsybl-core v4.7.0 to read them as well without issues.
Please note that it is possible to read and write XIIDM files in previous IIDM-XML versions.
In order to write XIIDM files in previous versions (e.g. the version 1.0), you need to use the following configuration property:
import-export-parameters-default-value:
iidm.export.xml.version: "1.0"
or use the Java object ExportOptions
in your parameters with a suitable set version:
... // do something
ExportOptions options = new ExportOptions().setVersion("1.0");
NetworkXml.write(network, options, path);
... // do something
Reading XIIDM files in previous versions does not require any particular configuration.
For more information about the new features, please read the documentation page on IIDM/IIDM-XML 1.7 evolutions.
These new features and changes include:
A new artifact has been introduced in this release: powsybl-iidm-modification
. The API ModificationTask
in powsybl-contingency-api
artifact has been renamed to NetworkModification and moved to this package. Besides, the ModificationTask::modify
method has been renamed to NetworkModification::apply
. Note that new apply
methods have also been introduced, but with default implementations to ensure backward compatibility.
All inheriting classes of ModificationTask
have been moved, from powsybl-action-util
and from powsybl-contingency-api
to that artifact. Some renaming occured at the same time, as the "task" keyword was removed but also for some classes to clarify the corresponding modification:
-
Contingency::toTask
renamed intoContingency::toModification
-
ContingencyElement::toTask
renamed intoContingencyElement::toModification
(which returns aTripping
instead of anAbstractTrippingTask
) -
CompoundModificationTask
renamed intoNetworkModificationList
-
CloseSwitchTask
renamed intoCloseSwitch
-
OpenSwitchTask
renamed intoOpenSwitch
-
GeneratorModificationTask
renamed intoGeneratorModification
-
PhaseShifterOptimizerTask
renamed intoPhaseShifterOptimizeTap
-
PhaseShifterFixedTapTask
renamed intoPhaseShifterSetAsFixedTap
-
PhaseShifterTapTask
renamed intoPhaseShifterShiftTap
-
AbstractTrippingTask
renamed intoAbstractTripping
-
ContingencyTopologyTraverser
renamed intoTrippingTopologyTraverser
In groovy scripts used with powsybl-action
, you can use the new keyword modifications
instead of the previous tasks
keyword, but tasks
is still supported.
simulShunt
and all associated methods in LoadFlowParameters
have been replaced by shuntCompensatorVoltageControlOn
.
All previous methods have been deprecated and call new methods.
All SecurityAnalysis::runAsync
and SecurityAnalysis::run
methods with no ContingenciesProvider
have been removed (a security analysis with no contingencies is of limited interest).
For a similar reason, the arguments order has been changed for methods SecurityAnalysis::runAsync
and SecurityAnalysis::run
:
- from
(Network, String, LimitViolationDetector, LimitViolationFilter, ComputationManager, SecurityAnalysisParameters, ContingenciesProvider, List<SecurityAnalysisInterceptor>, List<StateMonitor>)
to(Network, String, ContingenciesProvider, SecurityAnalysisParameters, ComputationManager, LimitViolationFilter, LimitViolationDetector, List<SecurityAnalysisInterceptor>, List<StateMonitor>)
- from
(Network, String, LimitViolationDetector, LimitViolationFilter, ComputationManager, SecurityAnalysisParameters, ContingenciesProvider, List<SecurityAnalysisInterceptor>)
to(Network, String, ContingenciesProvider, SecurityAnalysisParameters, ComputationManager, LimitViolationFilter, LimitViolationDetector, List<SecurityAnalysisInterceptor>)
A sensitivity analysis is based on a Network
called network
here.
Use SensitivityFactor
class to describe a sensitivity factor you want to compute. For example, if you want to evaluate the impact of a generator targetP
increase on the active power of a branch, without any contingency, you can simply write:
SensitivityFactor factor = new SensitivityFactor(SensitivityFunctionType.BRANCH_ACTIVE_POWER, "NHV1_NHV2_1", SensitivityVariableType.INJECTION_ACTIVE_POWER, "GEN", false, ContingencyContext.none());
where NHV1_NHV2_1 is the id of the monitored branch and GEN the id of the generator. Note that boolean false
just says if this factor is a variable set or not. A SensitivityVariableSet
is used to describe what is usually called GLSK (Generation and Load Shift Keys). A SensitivityVariableSet
is a simple class with an id (that cannot be already in the network) and a list of WeightedSensitivityVariable
. A weighted variable only has an id that refers to the variable id (a load or a generator id for example) and a weight. As we can compute several variable sets, you should provide a list of SensitivityVariableSet
, called variableSets
here, that could be empty.
If you want to simulate contingencies, just provide a list of contingencies
as List<Contingency>
.
Then, to run a sensitivity analysis, just do:
SensitivityAnalysisResult result = SensitivityAnalysis.run(network, VariantManagerConstants.INITIAL_VARIANT_ID, List.of(factor), contingencies, variableSets, parameters, computationManager, Reporter.NO_OP);
The following extensions' attributes have been made multi-variant in iidm-impl
:
-
targetQ
andenabled
inRemoteReactivePowerControl
-
droop
andparticipate
inActivePowerControl
-
qPercent
inCoordinatedReactiveControl
-
p0
,droop
andenabled
inHvdcAngleDroopActivePowerControl
-
oprFromCS1toCS2
andoprFromCS2toCS1
inHvdcOperatorActivePowerRange
Please note that these attributes can now vary from one variant to another.