Skip to content

Use System.Text.Json as a backend for view model serialization #3204

Use System.Text.Json as a backend for view model serialization

Use System.Text.Json as a backend for view model serialization #3204

GitHub Actions / firefox-tests-Linux-Development-Default completed Nov 2, 2024 in 0s

UI Test Results from firefox on Linux

This run completed at 11/02/2024 17:20:38

Details

Test Results - UI Test Results from firefox on Linux

Expand the following summaries for more details:

Duration: 1017.7377908 seconds
Times
Started: 2024-11-02T17:03:34.6383062+00:00
Creation: 2024-11-02T17:03:48.1503093+00:00
Queuing: 2024-11-02T17:03:48.1503094+00:00
Finished: 2024-11-02T17:20:32.3760970+00:00
Duration: 1017.7377908 seconds
Outcome: Failed | Total Tests: 592 | Passed: 585 | Failed: 3
Counters
Total: 592
Executed: 588
Passed: 585
Failed: 3
Error: 0
Timeout: 0
Aborted: 0
Inconclusive: 0
PassedButRunAborted: 0
NotRunnable: 0
NotExecuted: 0
Disconnected: 0
Warning: 0
Completed: 0
InProgress: 0
Pending: 0

Tests:

πŸ”˜ DotVVM.Samples.Tests.Feature.PostbackConcurrencyTests.Feature_PostbackConcurrency_RedirectPostbackQueue
Name: DotVVM.Samples.Tests.Feature.PostbackConcurrencyTests.Feature_PostbackConcurrency_RedirectPostbackQueue
Class Name: DotVVM.Samples.Tests.Feature.PostbackConcurrencyTests
Outcome: NotExecuted πŸ”˜
Duration: 00:00:00.0010000

❌ DotVVM.Samples.Tests.ErrorsTests.Error_FieldInValueBinding
Name: DotVVM.Samples.Tests.ErrorsTests.Error_FieldInValueBinding
Class Name: DotVVM.Samples.Tests.ErrorsTests
Outcome: Failed ❌
Duration: 00:00:03.4031565

Error Message

Riganti.Selenium.Core.Abstractions.Exceptions.SeleniumTestFailedException : 

-----------  Aggregated Inner Exceptions  -----------

// Exception #1: 
OpenQA.Selenium.NoSuchElementException: Element not found. Selector: .exceptionMessage; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_FieldInValueBinding>b__16_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 222
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147


// Exception #2: 
OpenQA.Selenium.NoSuchElementException: Element not found. Selector: .exceptionMessage; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_FieldInValueBinding>b__16_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 222
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147

---- OpenQA.Selenium.NoSuchElementException : Element not found. Selector: .exceptionMessage; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
---- OpenQA.Selenium.NoSuchElementException : Element not found. Selector: .exceptionMessage; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception

Error Stack Trace:

   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_FieldInValueBinding>b__16_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 222
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147
----- Inner Stack Trace #1 (OpenQA.Selenium.NoSuchElementException) -----
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_FieldInValueBinding>b__16_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 222
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147
----- Inner Stack Trace #2 (OpenQA.Selenium.NoSuchElementException) -----
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_FieldInValueBinding>b__16_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 222
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147

πŸ”˜ DotVVM.Samples.Tests.Feature.PostbackSpaNavigationTests.PostbackSpaNavigationTest_SuccessfulNavigation_SurvivingStaticCommand
Name: DotVVM.Samples.Tests.Feature.PostbackSpaNavigationTests.PostbackSpaNavigationTest_SuccessfulNavigation_SurvivingStaticCommand
Class Name: DotVVM.Samples.Tests.Feature.PostbackSpaNavigationTests
Outcome: NotExecuted πŸ”˜
Duration: 00:00:00.0010000

❌ DotVVM.Samples.Tests.ErrorsTests.Error_ExceptionWindow_LabelClickableTest
Name: DotVVM.Samples.Tests.ErrorsTests.Error_ExceptionWindow_LabelClickableTest
Class Name: DotVVM.Samples.Tests.ErrorsTests
Outcome: Failed ❌
Duration: 00:00:03.4433810

Error Message

Riganti.Selenium.Core.Abstractions.Exceptions.SeleniumTestFailedException : 

-----------  Aggregated Inner Exceptions  -----------

// Exception #1: 
OpenQA.Selenium.NoSuchElementException: Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_LabelClickableTest>b__19_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 259
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147


// Exception #2: 
OpenQA.Selenium.NoSuchElementException: Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_LabelClickableTest>b__19_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 259
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147

---- OpenQA.Selenium.NoSuchElementException : Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
---- OpenQA.Selenium.NoSuchElementException : Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception

Error Stack Trace:

   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_LabelClickableTest>b__19_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 259
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147
----- Inner Stack Trace #1 (OpenQA.Selenium.NoSuchElementException) -----
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_LabelClickableTest>b__19_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 259
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147
----- Inner Stack Trace #2 (OpenQA.Selenium.NoSuchElementException) -----
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_LabelClickableTest>b__19_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 259
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147

πŸ”˜ DotVVM.Samples.Tests.Control.CheckBoxTests.Control_CheckBox_CheckedItemsEmpty
Name: DotVVM.Samples.Tests.Control.CheckBoxTests.Control_CheckBox_CheckedItemsEmpty
Class Name: DotVVM.Samples.Tests.Control.CheckBoxTests
Outcome: NotExecuted πŸ”˜
Duration: 00:00:00.0010000

❌ DotVVM.Samples.Tests.ErrorsTests.Error_ExceptionWindow_DotNetReferenceSourceRedirect
Name: DotVVM.Samples.Tests.ErrorsTests.Error_ExceptionWindow_DotNetReferenceSourceRedirect
Class Name: DotVVM.Samples.Tests.ErrorsTests
Outcome: Failed ❌
Duration: 00:00:03.3255664

Error Message

Riganti.Selenium.Core.Abstractions.Exceptions.SeleniumTestFailedException : 

-----------  Aggregated Inner Exceptions  -----------

// Exception #1: 
OpenQA.Selenium.NoSuchElementException: Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_DotNetReferenceSourceRedirect>b__21_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 307
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147


// Exception #2: 
OpenQA.Selenium.NoSuchElementException: Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_DotNetReferenceSourceRedirect>b__21_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 307
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147

---- OpenQA.Selenium.NoSuchElementException : Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception
---- OpenQA.Selenium.NoSuchElementException : Element not found. Selector: label[for=menu_radio_stack_trace]; For documentation on this error, please visit: https://www.selenium.dev/documentation/webdriver/troubleshooting/errors#no-such-element-exception

Error Stack Trace:

   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_DotNetReferenceSourceRedirect>b__21_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 307
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147
----- Inner Stack Trace #1 (OpenQA.Selenium.NoSuchElementException) -----
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_DotNetReferenceSourceRedirect>b__21_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 307
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147
----- Inner Stack Trace #2 (OpenQA.Selenium.NoSuchElementException) -----
   at Riganti.Selenium.Core.BrowserWrapper.First(String selector, Func`2 tmpSelectMethod) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\BrowserWrapper.cs:line 413
   at DotVVM.Samples.Tests.ErrorsTests.<>c.<Error_ExceptionWindow_DotNetReferenceSourceRedirect>b__21_0(IBrowserWrapper browser) in /_/src/Samples/Tests/Tests/ErrorsTests.cs:line 307
   at Riganti.Selenium.Core.TestInstance.RunTest(IWebBrowser browser) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 138
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RunAsyncCore() in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 59
   at Riganti.Selenium.Core.TestInstance.RetryAsync(Func`1 action, Int32 testAttemptsCount) in D:\ba\_work\129\s\src\Core\Riganti.Selenium.Core\TestInstance.cs:line 147

πŸ”˜ DotVVM.Samples.Tests.ErrorsTests.Error_ExceptionWindow_GitHubRedirect
Name: DotVVM.Samples.Tests.ErrorsTests.Error_ExceptionWindow_GitHubRedirect
Class Name: DotVVM.Samples.Tests.ErrorsTests
Outcome: NotExecuted πŸ”˜
Duration: 00:00:00.0010000