Skip to content

Commit

Permalink
Update README.md
Browse files Browse the repository at this point in the history
  • Loading branch information
slipx06 authored May 6, 2023
1 parent 15b2d4d commit 6f03163
Showing 1 changed file with 81 additions and 34 deletions.
115 changes: 81 additions & 34 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -5,7 +5,7 @@ An animated Home Assistant card to emulate the Sunsynk power flow that's shown o

## Features
* Option to switch between three card styles: `lite`, `simple` or `full`.
* Animated power flow based on positive/negative/zero sensor values.
* Animated power flow based on positive/negative/zero sensor values. (Supports inverted battery power).
* Dynamic battery image based on SOC (empty->low->medium->high).
* Grid connected status. A red dot is displayed when the grid is disconnected.
* Inverter status (standby, normal, self-test, alarm, fault) is displayed as a colour coded dot.
Expand All @@ -14,7 +14,7 @@ An animated Home Assistant card to emulate the Sunsynk power flow that's shown o
* Hide all solar data if not installed.
* "Use Timer" setting and "Energy Pattern" setting (Priority Load or Priority Battery) shown as dynamic icons with ability to hide if not required.
* Panel mode for bigger card
* We all like a little colour. Modify the inverter colour
* Customisable - Change colours and inverter image

## Screenshots
Note that the inverter image was changed after version 1.0.5 to create a more unified look and feel. I need to update the screenshots
Expand Down Expand Up @@ -53,11 +53,6 @@ Add the `Custom: Sunsynk Power Flow Card` to your Dashboard view.

![image](https://user-images.githubusercontent.com/7227275/235375690-65d17663-e117-4626-9151-1a41979a13b8.png)

It will show the following:

![sunsynk-power-flow-card_options](https://user-images.githubusercontent.com/7227275/235947428-a202ad40-348b-4c8a-a186-6f564481ff34.gif)


### Card Options

The card requires that all of these attributes be defined.
Expand All @@ -66,14 +61,55 @@ The card requires that all of these attributes be defined.
| --- | --- | --- |
|type: | `custom:sunsynk-power-flow-card` | The custom card |
|cardstyle: | `lite` | Selects the card layout that is used `lite, simple, full` |
|panel_mode:| `no` | Toggles panel mode removing any card height restrictions. For use with Panel(1 card) view types or grid layouts|
|show_daily: | `yes` | Toggles the Daily Totals `yes/no` |
|battery_energy: | `15960` | Total Battery Energy in Wh (e.g. 3 x 5.32kWh = 15960). If set to `hidden` the remaining battery runtime will be hidden|
|battery_shutdown_soc: | `20` |The battery shutdown percentage used to calculate remaining runtime |
|inverter: | | List of inverter attributes. See required [Inverter](#inverter) attributes below |
|battery: | | List of battery attributes. See required [Battery](#battery) attributes below |
|solar: | | List of solar attributes. See required [Solar](#solar) attributes below |
|load: | | List of load attributes. See required [Load](#load) attributes below |
|grid: | | List of grid attributes. See required [Grid](#grid) attributes below |
|entities:||List of sensor entities. See required [Entities](#entities) attributes below|

### Inverter
Requires the folowing:

| Attribute | Default | Description |
| --- | --- | --- |
|modern:| `no`| Changes the inverter image.|
|colour:| `grey`| Changes the colour of the inverter. Hex codes (`'#66ff00'` etc) or names (`red`, `green`, `blue` etc) |


### Battery
Requires the folowing:

| Attribute | Default | Description |
| --- | --- | --- |
|energy: | `15960` | Total Battery Energy in Wh (e.g. 3 x 5.32kWh = 15960). If set to `hidden` the remaining battery runtime will be hidden|
|shutdown_soc: | `20` |The battery shutdown percentage used to calculate remaining runtime |
|invert_power:| `no`|Set to `yes` if your sensor provides a positive number for battery charge and negative number for batter discharge|
|colour:| `pink`| Changes the colour of al the battery card objects. Hex codes (`'#66ff00'` etc) or names (`red`, `green`, `blue` etc) |

### Solar
Requires the folowing:

| Attribute | Default | Description |
| --- | --- | --- |
|show_solar:| `yes` | Toggle display of solar information `yes/no`|
|panel_mode:| `no` | Toggles panel mode removing any card height restrictions. For use with Panel(1 card) view types or grid layouts|
|inverter_colour:| `'#959595'`| Changes the colour of the inverter. Hex codes (`'#66ff00'` etc) or names (`red`, `green`, `blue` etc) |
|invert_battery_power:| `no`|Set to `yes` if your sensor provides a positive number for battery charge and negative number for batter discharge|
|entities:||List of sensor entities. See required [Entities](#entities) below|
|colour:| `orange`| Changes the colour of al the solar card objects. Hex codes (`'#66ff00'` etc) or names (`red`, `green`, `blue` etc) |

### Load
Requires the folowing:

| Attribute | Default | Description |
| --- | --- | --- |
|colour:| `'#5fb6ad'`| Changes the colour of al the load card objects. Hex codes (`'#66ff00'` etc) or names (`red`, `green`, `blue` etc) |

### Grid
Requires the folowing:

| Attribute | Default | Description |
| --- | --- | --- |
|colour:| `'#5490c2'`| Changes the colour of all the grid card objects. Hex codes (`'#66ff00'` etc) or names (`red`, `green`, `blue` etc) |

### Entities
Entity attributes below have been appended with the modbus register # e.g. `pv2_power_187` to indicate which Sunsynk register should be read when configuring your sensors. Replace the default sensors with your own specific sensor names. It is important that your sensors read the expected modbus register value. If you have missing sensors for any attribute set it to none i.e. `solarday_108: none` and it will use a default value of 0.
Expand Down Expand Up @@ -123,38 +159,49 @@ The modbus registers can be visualised on the `full` card below:

```
type: custom:sunsynk-power-flow-card
cardstyle: simple
show_daily: 'yes'
battery_energy: 5320
battery_shutdown_soc: 20
show_solar: 'yes'
cardstyle: lite
panel_mode: 'yes'
inverter_colour: '#959595'
show_daily: 'yes'
inverter:
modern: 'yes'
colour: '#959595'
battery:
energy: 15960
shutdown_soc: 20
invert_power: 'no'
colour: pink
solar:
show_solar: 'yes'
colour: orange
load:
colour: '#5fb6ad'
grid:
colour: '#5490c2'
entities:
use_timer_248: switch.toggle_system_timer
priority_load_243: swithc.toggle_priority_load
batdischargeday_71: sensor.day_battery_discharge
batchargeday_70: sensor.day_battery_charge
loadday_84: sensor.day_load_energy
gridday_76: sensor.day_grid_import
solarday_108: sensor.day_solar_pv_kwh
inverter_grid_voltage_154: sensor.inverter_voltage
inverter_load_freq_192: sensor.inverter_frequency
inverter_out_164: sensor.inverter_current
inverter_out_175: sensor.inverter_power
inverter_load_grid_169: sensor.grid_power
priority_load_243: switch.toggle_priority_load
batchargeday_70: sensor.battery_charge_day
batdischargeday_71: sensor.battery_discharge_day
loadday_84: sensor.daily_load_power_kwh
gridday_76: sensor.grid_import_day_buy
solarday_108: sensor.daily_pv_power_kwh
inverter_grid_voltage_154: sensor.grid_inverter_voltage
inverter_load_freq_192: sensor.load_frequency
inverter_out_164: sensor.inverter_output_current
inverter_out_175: sensor.inverter_output_power
inverter_load_grid_169: sensor.grid_inverter_load
pv2_power_187: sensor.pv2_power
pv1_power_186: sensor.pv1_power
battery_voltage_183: sensor.battery_voltage
battery_soc_184: sensor.battery_soc
battery_out_190: sensor.battery_power
epower: sensor.essential_power
grid_external_power_172: sensor.grid_ct_power
battery_out_190: sensor.battery_output_power
ess_power: sensor.sunsynk_essential_load
grid_external_power_172: sensor.grid_external_power
pv1_v_109: sensor.dc1_voltage
pv1_i_110: sensor.dc1_current
pv2_v_111: sensor.dc2_voltage
pv2_i_112: sensor.dc2_current
grid_status_194: sensor.grid_connected_status
grid_status_194: binary_sensor.grid_connected_status
inverter_status_59: sensor.overall_state
aux_power_166: sensor.aux_output_power
Expand Down

0 comments on commit 6f03163