Expand Up @@ -3,27 +3,26 @@
import time

class Powerpi:
PORT = 1
ADDRESS = 0x6a #I2C address of the ups

#Refer to http://www.ti.com/lit/ds/symlink/bq25895.pdf for register maps

REG_WATCHDOG = 0x07
BYTE_WATCHDOG_STOP = 0b10001101 #Stop Watchdog timer
REG_SYSMIN = 0x03
BYTE_SYSMIN = 0b00010000
REG_ILIM = 0x00 #ILIM register
REG_VREG = 0x06 #Charge voltage register

####Edit this section to suit your needs######
####Edit this section to suit your battery and input specs##############################

"""
BYTE_ILIM is used to set the input current limit, i.e the maximum current the
UPS will draw from the power input. It does not affect the output current from
the UPS. If more current is required at the output than the input is cpabale of,
the UPS will augment that current from the battery.
"""
#BYTE_ILIM = 0b01101000 #2A input current limit
BYTE_ILIM = 0b01111111 #3.25A input current limit
#BYTE_ICHG = 0b00001000 #.5A charging current limit
BYTE_ICHG = 0b00010000 #1A charging current limit
BAT_CAPACITY = 2900 #Battery capacity in mAh
CURRENT_DRAW = 2000 #Current draw in mAh approximately
VBAT_LOW = 3.2
VBAT_MAX = 4.208
#Charge Voltage

VBAT_LOW = 3.2 # Determines the battery voltage at which the UPS will shutoff.

#Charge Voltage, uncomment the line suitable for your battery type.
#BYTE_VREG = 0b00000010 #3.84v
#BYTE_VREG = 0b00010010 #3.9V
#BYTE_VREG = 0b00101010 #4V
Expand All @@ -33,7 +32,34 @@ class Powerpi:
#BYTE_VREG = 0b10001110 #4.4V
#BYTE_VREG = 0b10101010 #4.512V
#BYTE_VREG = 0b11000010 #4.608V
###############################################

"""
BAT_CAPACITY, CURRENT_DRAW and VBAT_MAX are used to estimated the state of charge
of the battery since there is not current sensor on this UPS. These values along
with the battery voltage is used to derive the state of charge of the battery.
To make the charge percent of the battery shown more accurate, take a note of
the battery voltage when charging is complete (red LED turns off after plugging in)
and edit the VBAT_MAX to that value.
NB:Changing these values does not affect or change the behavior of the UPS.
"""
BAT_CAPACITY = 2900 #Battery capacity in mAh
CURRENT_DRAW = 2000 #Current draw in mAh approximately
VBAT_MAX = 4.208 #This should be the battery when charged to a 100%

##################################################################################


PORT = 1
ADDRESS = 0x6a #I2C address of the ups

REG_WATCHDOG = 0x07
BYTE_WATCHDOG_STOP = 0b10001101 #Stop Watchdog timer
REG_SYSMIN = 0x03
BYTE_SYSMIN = 0b00010000
REG_ILIM = 0x00 #ILIM register
REG_VREG = 0x06 #Charge voltage register

REG_ICHG = 0x04
REG_ICHGR = 0x12