-
Notifications
You must be signed in to change notification settings - Fork 6
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #35 from bhawnasehgal/main
Update hardware content, add guides menu
- Loading branch information
Showing
39 changed files
with
594 additions
and
152 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,11 @@ | ||
.. _upsidedownlabs-guides: | ||
|
||
Guides | ||
###################### | ||
|
||
.. toctree:: | ||
:hidden: | ||
:maxdepth: 1 | ||
|
||
usage-guides/skin-preparation/index | ||
usage-guides/using-bioamp-bands/index |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,87 @@ | ||
.. _skin-preparation: | ||
|
||
Skin Preparation Guide | ||
########################## | ||
|
||
Why skin preparation is important? | ||
*********************************** | ||
|
||
Proper skin preparation is crucial before recording any biopotential signal be it Electrocardiography (ECG), Electromyography (EMG), Electroencephalography (EEG), or Electrooculography (EOG). | ||
|
||
- ``Clear recording surface`` Removes dead skin cells, oils, & other substances that increases skin impedance. | ||
- ``Improve impedance`` Improves the conduction of electrical signals from the body to the recording equipment and minimizes impedance. | ||
- ``Electrode-skin contact`` Ensures optimal contact between the electrodes and the skin surface. | ||
- ``Signal quality`` Enhances the overall quality of recorded signals, providing clear & reliable data for analysis & improves the ability to capture subtle variations in biopotential signals. | ||
- ``Consistency in recordings`` Reduces variability in signal quality, making it easier to make any Human-Computer Interface (HCI), Brain-Computer Interface (BCI) project or a real-world application. | ||
- ``Long term adhesion`` Facilitates long-term adhesion & stable placement of electrodes to the skin during extended signal monitoring. | ||
|
||
Requirements | ||
************** | ||
|
||
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | ||
| **NuPrep Gel** | Mildly abrasive, highly conductive gel that should be applied before placing the electrodes on the skin to improve signal quality & enhances the performance of monitoring electrodes. | | ||
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | ||
| **Electrode Gel** | Highly conductive gel that acts as a coupling agent between electrodes and the skin to aid the transmission of biopotential signals like ECG, EMG, EOG, or EEG. | | ||
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | ||
| **Ten20 Paste** | Contains the right balance of adhesiveness and conductivity, enabling the dry electrodes to remain in place while allowing the transmittance of biopotential signals. | | ||
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | ||
| **Alcohol Swabs/Wet wipes** | Soft & non-woven pads that helps in cleaning the skin surface and does not leave any residue. | | ||
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | ||
|
||
Steps to follow | ||
***************** | ||
|
||
You can follow the steps given below to do the skin preparation properly: | ||
|
||
Step 1: Identify the targeted area | ||
===================================== | ||
|
||
Identify the target area where the gel electrodes will be placed for recording ECG, EMG, EEG, or EOG. | ||
|
||
.. image:: media/skin-prep-eog.* | ||
|
||
.. image:: media/skin-prep-emg.* | ||
|
||
.. image:: media/skin-prep-ecg.* | ||
|
||
.. image:: media/skin-prep-eeg.* | ||
|
||
Step 2: Apply the gel | ||
====================== | ||
|
||
Apply a drop of NuPrep gel to your targeted area where the electrodes will be placed. | ||
|
||
.. image:: media/step-2.* | ||
|
||
Step 3 | ||
======= | ||
|
||
Use gentle, circular motions to rub the gel on the skin surface. This removes all the dead skin cells & improves conductivity. | ||
|
||
.. warning:: Do not rub the gel for too long as it has abrasive properties and may cause skin redness and irritation. | ||
|
||
Step 4 | ||
======== | ||
|
||
Wipe away excess gel with the alcohol swabs or wet wipes. | ||
|
||
.. warning:: Close your eyes while using the alcohol swabs for EOG recording else it may cause eye redness & irritation. | ||
|
||
Step 5 | ||
======== | ||
|
||
Now you can either use gel electrodes or the BioAmp bands for the signal recording. | ||
|
||
Using gel electrodes | ||
---------------------- | ||
|
||
Connect the BioAmp cable to gel electrodes, peel the plastic backing from electrodes and place the IN+, IN-, REF cables according to your specific biopotential recording. | ||
|
||
Using BioAmp bands | ||
---------------------- | ||
|
||
Connect the BioAmp cable to your BioAmp band. Now apply a small amount of electrode gel or Ten20 conductive paste on the dry electrodes between the skin and metallic part of BioAmp cable. This improves the signal conductivity, enhancing overall signal quality. | ||
|
||
Now you are all set! Make all the connections correctly and start recording your biopotential signals. | ||
|
||
.. note:: NuPrep gel, Ten20 paste and the alcohol swabs shouldn't be used if you have a history of skin allergies to lotions and cosmetics. |
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,4 @@ | ||
.. _using-bioamp-bands: | ||
|
||
Using BioAmp Bands | ||
################## |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file not shown.
Binary file not shown.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Oops, something went wrong.